Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Chem Lab Med ; 61(11): 1942-1954, 2023 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-37466369

RESUMO

OBJECTIVES: Topiramate is an antiepileptic drug (AED) used for the monotherapy or adjunctive treatment of epilepsy and for the prophylaxis of migraine. It has several pharmacodynamic properties that contribute to both its clinically useful properties and observed adverse effects. Accurate measurement of its concentration is therefore essential for dose adjustment/optimisation of AED therapy. Our aim was to develop and validate a novel reference measurement procedure (RMP) for the quantification of topiramate in human serum and plasma. METHODS: An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) method in combination with a protein-precipitation-based sample preparation allows for quantification of topiramate in human serum and plasma. To assure traceability to SI units, quantitative nuclear magnetic resonance (qNMR) was applied to characterize the reference material used as primary calibrator for this RMP. Matrix effects were determined by performing a post-column infusion experiment and comparing standard line slopes. Accuracy and precision was evaluated performing an extensive five day precision experiment and measurement uncertainty was evaluated according Guide to the Expression of Uncertainty in Measurement (GUM). RESULTS: The method enabled topiramate quantification within the range of 1.20-36.0 µg/mL without interference from structurally related compounds and no evidence of a matrix effect. Intermediate precision was ≤3.2 % and repeatability was 1.4-2.5 % across all concentration levels. The relative mean bias was -0.3 to 3.5 %. Expanded measurement uncertainties for target value assignment (n=6) were found to be ≤2.9 % (k=2) independent of the concentration level and the nature of the sample. CONCLUSIONS: In human serum and plasma, the RMP demonstrated high analytical performance for topiramate quantification and fulfilled the requirements on measurement uncertainty. Traceability to SI units was established by qNMR content determination of the topiramate, which was used for direct calibration of the RMP. This RMP is, therefore, fit for purpose for routine assay standardization and clinical sample evaluation.


Assuntos
Plasma , Espectrometria de Massas em Tandem , Humanos , Cromatografia Líquida/métodos , Topiramato , Espectrometria de Massas em Tandem/métodos , Técnicas de Diluição do Indicador , Anticonvulsivantes , Isótopos , Padrões de Referência
2.
Clin Chem Lab Med ; 61(11): 1930-1941, 2023 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-36785916

RESUMO

OBJECTIVES: We developed an isotope dilution (ID)-liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based candidate reference measurement procedure (RMP) for lamotrigine in human serum and plasma, using quantitative nuclear magnetic resonance-characterized reference standards to ensure traceability to the International System of Units. METHODS: A sample preparation protocol based on protein precipitation combined with LC-MS/MS analysis using a C18 column for chromatographic separation was established for the quantification of lamotrigine in human serum and plasma. Assay validation was performed according to current guidelines. Spiked serum and plasma samples were used to assess selectivity and specificity; a post-column infusion experiment and comparison of standard line slopes were performed to ascertain possible matrix effects. Precision and accuracy were determined in a 5 days validation experiment. Measurement uncertainty was determined per the Guide to the Expression of Uncertainty in Measurement. RESULTS: The method allowed the quantification of lamotrigine in serum and plasma in a range of 0.600-24.0 µg/mL without any observable matrix effects. The relative mean bias (n=6) ranged from 1.7 to 3.7%; intermediate precision, including variances in between-day, -calibration, and -injection, was ≤2.4%, independent of the level and matrix. Total measurement uncertainty for a single measurement was ≤2.6%; expanded uncertainty was ≤5.2% (coverage factor k=2). CONCLUSIONS: This candidate RMP based on ID-LC-MS/MS provides a traceable and reliable platform for the standardization of routine assays and the evaluation of clinical samples.


Assuntos
Anticonvulsivantes , Espectrometria de Massas em Tandem , Humanos , Cromatografia Líquida/métodos , Lamotrigina , Espectrometria de Massas em Tandem/métodos , Isótopos , Padrões de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...