1.
J Surg Res ; 168(2): 243-52, 2011 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-20097366

RESUMO

BACKGROUND: Lipid peroxidation processes (LPO) are evident in many organ failures. Due to their toxic properties, they are causative for cellular dysfunction at the site of their origin and far beyond. This study was conducted to investigate differences in LPO pattern of patients with established acute respiratory distress syndrome (ARDS) and patients with end-stage liver failure undergoing liver transplantation (LTX) as two mayor prototypes of organ failure. METHODS: In this prospective, nonrandomized, controlled trial, we examined LPO by measuring malondialdehyde (MDA), and the volatile aldehydes hexanal and propanal as LPO-markers. Eighteen patients with ARDS, 16 subjects undergoing liver transplantation due to liver failure, and 8 healthy controls were included to the study. RESULTS: ARDS patients showed significantly higher levels in MDA concentrations than LTX and controls, respectively. However, MDA levels of patients with end-stage liver failure were equal to those of controls. Blood concentrations of hexanal and propanal, specific by-products of lipid peroxidation, were elevated in both patient groups, but significantly higher only in LTX. Unexpectedly, hexanal and propanal concentrations were significantly higher in LTX than in ARDS patients. In both patient groups, MDA showed no differences between arterial and mixed venous blood, whereas volatile aldehydes were higher in arterial than in mixed venous compartment. CONCLUSIONS: Both ARDS and LTX-patients showed significant evidence of enhanced LPO. However, proportions of MDA and volatile aldehydes differed substantially between the groups. Thus, for the interpretation of LPO markers, disease-specific factors have to be taken into account. Distinctions might be attributable to differences in the effected lipid components or variations in metabolism.


Assuntos
Peroxidação de Lipídeos , Falência Hepática/metabolismo , Síndrome do Desconforto Respiratório/metabolismo , Adolescente , Adulto , Idoso , Aldeídos/sangue , Estudos de Casos e Controles , Ácidos Graxos Insaturados/metabolismo , Feminino , Hemodinâmica , Humanos , Masculino , Malondialdeído/sangue , Pessoa de Meia-Idade , Estudos Prospectivos , Síndrome do Desconforto Respiratório/etiologia , Adulto Jovem
2.
Artigo em Inglês | MEDLINE | ID: mdl-12076693

RESUMO

4-Hydroxynon-2-enal (4-HNE) is one of the major aldehydic products of lipid peroxidation (LPO) and is involved in a number of pathophysiological processes. Since LPO products are useful indicators for oxidative stress in vivo, a number of detection methods for LPO products in biological tissues were developed. However, none of these methods is presently used in clinical settings. In order to introduce LPO products as biomarkers in clinical studies a suitable GC-MS method for 4-HNE detection was adapted to meet clinical requirements. As one result, the minimal sample volume could be decreased to 50 microl of plasma so that the method might even be suitable for pediatric purposes. The best internal standard (I.S.) for 4-HNE detection by GC-MS 9,9,9-D(3)-4-hydroxynon-2-enal was introduced by van Kuijk et al. [Anal. Biochem., 224 (1995) 420]. However, because of its limited availability, benzaldehyde-ring-d(5), 4-hydroxybenzaldehyde, and 2,5-dihydroxybenzaldehyde were tested to find an alternative. Out of these three, 4-hydroxybenzaldehyde was shown to serve best as I.S. To examine the applicability of the adapted method, tests on the stability of 4-HNE in samples during storage were carried out. It was shown that plasma samples need to be stored at -80 degrees C or less to avoid greater loss of 4-HNE. Samples with 4-HNE concentrations close to the physiological level were shown to be stable over 22 months at -80 degrees C. The introduction of a new and easily available I.S., reduction of the sample volume, and information about sample stability provided by this study facilitate 4-HNE determination in most clinical settings.


Assuntos
Aldeídos/sangue , Cromatografia Gasosa-Espectrometria de Massas/métodos , Humanos , Peroxidação de Lipídeos , Reprodutibilidade dos Testes