Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Artif Organs ; 45(12): 1562-1575, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34519059

RESUMO

BACKGROUND: Arterial compliance assists the cardiovascular system with three key roles: (i) storing up to 50% of the stroke volume; (ii) ensuring blood flow during diastole; (iii) dampening pressure oscillations through arterial distension. In mock circulation loops (MCLs), arterial compliance was simulated either with membrane, spring, or Windkessel chambers. Although they have been shown to be suitable for cardiac device testing, their passive behavior can limit stress-based testing of arteries. Here we present an active compliance chamber with a feedback control of variable compliance as part of an MCL designed for biomechanical evaluation of arteries under physiological waveforms. MATERIALS AND METHODS: The chamber encloses a piston that changes the volume via a cascaded controller when there is a difference between the real-time pressure and the physiological reference pressure with the aim to equilibrate both pressures. RESULTS: The experimental results showed repeatable physiological waveforms of aortic pressure in health (80-120 mm Hg), systemic hypertension (90-153 mm Hg), and heart failure reduced ejection fraction (78-108 mm Hg). Statistical validation (n = 20) of the function of the chamber is presented against compared raw data. CONCLUSION: We demonstrate that the active compliance chamber can track the actual pressure of the MCL and balance it in real time (every millisecond) with the reference values in order to shape the given pressure waveform. The active compliance chamber is an advanced tool for MCL applications for biomechanical examination of stented arteries and for preclinical evaluation of vascular implants.


Assuntos
Artérias/fisiologia , Pressão Sanguínea/fisiologia , Modelos Cardiovasculares , Fenômenos Fisiológicos Cardiovasculares , Complacência (Medida de Distensibilidade) , Hemodinâmica , Humanos
2.
J Electrocardiol ; 59: 100-105, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32036110

RESUMO

BACKGROUND: Coronary artery disease (CAD) is a leading cause of death and disability. Conventional non-invasive diagnostic modalities for the detection of stable CAD at rest are subject to significant limitations: low sensitivity, and personal expertise. We aimed to develop a reliable and time-cost efficient screening tool for the detection of coronary ischemia using machine learning. METHODS: We developed a supervised artificial intelligence algorithm combined with a five lead vectorcardiography (VCG) approach (i.e. Cardisiography, CSG) for the diagnosis of CAD. Using vectorcardiography, the excitation process of the heart can be described as a three-dimensional signal. A diagnosis can be received, by first, calculating specific physical parameters from the signal, and subsequently, analyzing them with a machine learning algorithm containing neuronal networks. In this multi-center analysis, the primary evaluated outcome was the accuracy of the CSG Diagnosis System, validated by a five-fold nested cross-validation in comparison to angiographic findings as the gold standard. Individuals with 1, 2, or 3- vessel disease were defined as being affected. RESULTS: Of the 595 patients, 62·0% (n = 369) had 1, 2 or 3- vessel disease identified by coronary angiography. CSG identified a CAD at rest with a sensitivity of 90·2 ± 4·2% for female patients (male: 97·2 ± 3·1%), specificity of 74·4 ± 9·8% (male: 76·1 ± 8·5%), and overall accuracy of 82·5 ± 6·4% (male: 90·7 ± 3·3%). CONCLUSION: These findings demonstrate that supervised artificial intelligence-enabled vectorcardiography can overcome limitations of conventional non-invasive diagnostic modalities for the detection of coronary ischemia at rest and is capable as a highly valid screening tool.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Isquemia Miocárdica , Inteligência Artificial , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Estenose Coronária/diagnóstico , Feminino , Humanos , Masculino , Isquemia Miocárdica/diagnóstico , Sensibilidade e Especificidade , Vetorcardiografia
3.
Biomed Tech (Berl) ; 64(3): 247-250, 2019 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-29902152

RESUMO

Due to the declining instances of organ donation, total artificial heart (TAH) therapy is of increasing importance for the management of end-stage biventricular heart failure. We introduce the currently most important established and novel TAH systems (SynCardia, CARMAT, ReinHeart, BiVACOR), report clinical outcomes and discuss technical requirements for the successful implementation of TAH therapy as an alternative to cardiac transplantation.


Assuntos
Insuficiência Cardíaca/fisiopatologia , Transplante de Coração/métodos , Coração Artificial , Humanos
6.
SAGE Open Med Case Rep ; 6: 2050313X18789217, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30083321

RESUMO

Management of end-stage heart failure patients requiring major general surgery is not well defined. Due to poor cardiorespiratory reserve, perioperative morbidity and mortality are excessively high. We report a case of temporary implementation of veno-arterial extracorporeal membrane oxygenation for haemodynamic support during excision of rectal carcinoma in an end-stage heart failure patient and describe perioperative management.

8.
Artif Organs ; 41(2): 122-129, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27582339

RESUMO

At our institute a total artificial heart is being developed. It is directly actuated by a linear drive in between two ventricles, which comprise membranes to separate the drive and blood flow. A compliance chamber (CC) is needed to reduce pressure peaks in the ventricles and to increase the pump capacity. Therefore, the movement of the membrane is supported by applying a negative pressure to the air volume inside the drive unit. This study presents the development of the implantable CC which is connected to the drive unit of the total artificial hearts (TAH). The anatomical fit of the CC is optimized by analyzing CT data and adapting the outer shape to ensure a proper fit. The pressure peaks are reduced by the additional volume and the flexible membrane of the CC. The validation measurements of change in pressure peaks and flow are performed using the complete TAH system connected to a custom mock circulation loop. Using the CC, the pressure peaks could be damped below 5 mm Hg in the operational range. The flow output was increased by up to 14.8% on the systemic side and 18.2% on the pulmonary side. The described implantable device can be used for upcoming chronic animal trials.


Assuntos
Coração Artificial , Coração/anatomia & histologia , Hemodinâmica , Humanos , Desenho de Prótese , Implantação de Prótese , Tórax/anatomia & histologia
9.
J Thorac Dis ; 8(7): 1546-9, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27499942

RESUMO

BACKGROUND: Congestive hepatopathy (CH) and acute liver failure (ALF) are common among biventricular heart failure patients. We sought to evaluate the impact of total artificial heart (TAH) therapy on hepatic function and associated clinical outcomes. METHODS: A total of 31 patients received a Syncardia Total Artificial Heart. Preoperatively 17 patients exhibited normal liver function or mild hepatic derangements that were clinically insignificant and did not qualify as acute or chronic liver failure, 5 patients exhibited ALF and 9 various hepatic derangements owing to CH. Liver associated mortality and postoperative course of liver values were prospectively documented and retrospectively analyzed. RESULTS: Liver associated mortality in normal liver function, ALF and CH cases was 0%, 20% (P=0.03) and 44.4% (P=0.0008) respectively. 1/17 (5.8%) patients with a normal liver function developed an ALF, 4/5 (80%) patients with an ALF experienced a markedly improvement of hepatic function and 6/9 (66.6%) patients with CH a significant deterioration. CONCLUSIONS: TAH therapy results in recovery of hepatic function in ALF cases. Patients with CH prior to surgery form a high risk group with increased liver associated mortality.

10.
Interact Cardiovasc Thorac Surg ; 23(6): 976-978, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27481685

RESUMO

Currently available diagnostic modalities for the detection of graft vasculopathy following orthotopic heart transplantation are subject to various restrictions. We hypothesized that cardiogoniometry, a novel non-invasive diagnostic tool for the detection of atherosclerotic coronary vessel disease, is applicable in the graft vasculopathy setting. Cardiogoniometric results were obtained during routine follow-up in 49 consecutive, unselected heart transplant recipients and then retrospectively correlated blindly by an independent reader to recent angiographic findings. Sensitivity of cardiogoniometry was 100%, specificity 62.3%, positive predictive value 68.75%, negative predictive value 100%, negative likelihood ratio 0 and positive likelihood ratio 2.888. Cardiogoniometry is potentially applicable as an easy-to-perform, non-invasive screening tool predominantly for the exclusion but also for the detection of graft vasculopathy in heart transplant recipients.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Transplante de Coração/efeitos adversos , Transplantados , Adulto , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
14.
Dtsch Arztebl Int ; 113(3): 39, 2016 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-26857512
17.
Artigo em Inglês | MEDLINE | ID: mdl-26438624

RESUMO

Despite downsizing, implantation technique of the 50-cm(3) SynCardia Total Artificial Heart and settings of the Companion driver remain unchanged. Owing to the absence of de-airing nipples, de-airing procedure is even more crucial and has to be performed carefully.


Assuntos
Insuficiência Cardíaca/cirurgia , Coração Artificial , Implantação de Prótese/métodos , Adolescente , Adulto , Feminino , Humanos , Masculino , Implantação de Prótese/instrumentação
18.
Ann Thorac Surg ; 100(3): e55-7, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26354668

RESUMO

The 50-cc SynCardia total artificial heart is designed to facilitate orthotopic replacement of the native ventricles in patients with a body surface area below 1.7 m(2) in need of long-term circulatory support as a result of end-stage biventricular heart failure. We describe the implementation of this technology in a female patient with irreversible cardiogenic shock on the grounds of acute myocardial infarction and chronic ischemic cardiomyopathy.


Assuntos
Coração Artificial , Choque Cardiogênico/cirurgia , Idoso , Procedimentos Cirúrgicos Cardíacos , Feminino , Humanos , Desenho de Prótese
20.
Interact Cardiovasc Thorac Surg ; 21(1): 117-8, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25812564

RESUMO

Coagulation disorders and an immune-altered state are common among total artificial heart patients. In this context, we sought to evaluate the safety of percutaneous dilatational tracheostomy in cases of prolonged need for mechanical ventilatory support. We retrospectively analysed the charts of 11 total artificial heart patients who received percutaneous dilatational tracheostomy. We focused on early and late complications. We observed no major complications and no procedure-related deaths. Early minor complications included venous oozing (45.4%) and one case of local infection. Late complications, including subglottic stenosis, stomal infection or infections of the lower respiratory tract, were not observed. In conclusion, percutaneous dilatational tracheostomy in total artificial heart patients is safe. Considering the well-known benefits of early tracheotomy over prolonged translaryngeal intubation, we advocate early timing of therapy in cases of prolonged mechanical ventilation.


Assuntos
Cardiomiopatias/complicações , Insuficiência Cardíaca/cirurgia , Coração Artificial , Implantação de Prótese/instrumentação , Traqueostomia/métodos , Adulto , Idoso , Cardiomiopatias/diagnóstico , Cardiomiopatias/fisiopatologia , Dilatação , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Intubação Intratraqueal , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Implantação de Prótese/efeitos adversos , Respiração Artificial , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Traqueostomia/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...