Ultrason Imaging ; 38(4): 285-97, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26416839

RESUMO

Backscatter-difference measurements may be used to detect changes in bone caused by osteoporosis. The backscatter-difference technique measures the power difference between two portions of an ultrasonic backscatter signal. The goal of this study is to evaluate the feasibility of using an ultrasonic imaging system to perform backscatter-difference measurements of bone. Ultrasonic images and backscatter signals were acquired from 24 specimens of human cancellous bone. The signals were analyzed in the frequency domain to determine the normalized mean backscatter-difference (nMBD) and in the time domain to determine the normalized backscatter amplitude ratio (nBAR). The images were analyzed to determine the normalized pixel value difference (nPVD), which measures the difference in average pixel brightness between regions of interest placed at two different depths in the image. All three parameters were found to increase with bone mineral density. The signal-based parameters, nMBD and nBAR, correlated well with bone mineral density, yielding linear correlation coefficients that ranged from 0.74 to 0.87. The image based parameter, nPVD, performed somewhat less well, yielding correlation coefficients that ranged from 0.42 to 0.81. These results suggest that ultrasonic imaging systems may be used to perform backscatter-difference measurements for the purpose of ultrasonic bone assessment.


Assuntos
Osso Esponjoso/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Osteoporose/diagnóstico por imagem , Processamento de Sinais Assistido por Computador , Ultrassonografia/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Espalhamento de Radiação
2.
Artigo em Inglês | MEDLINE | ID: mdl-26683412

RESUMO

Ultrasonic backscatter techniques are being developed to detect changes in cancellous bone caused by osteoporosis. Many techniques are based on measurements of the apparent backscatter transfer function (ABTF), which represents the backscattered power from bone corrected for the frequency response of the measurement system. The ABTF is determined from a portion of the backscatter signal selected by an analysis gate of width τw delayed by an amount τd from the start of the signal. The goal of this study was to characterize the ABTF for a wide range of gate delays (1 µs ≤ τd ≤ 6 µs) and gate widths (1 µs ≤ τw ≤ 6 µs). Measurements were performed on 29 specimens of human cancellous bone in the frequency range 1.5 to 6.0 MHz using a broadband 5-MHz transducer. The ABTF was found to be an approximately linear function of frequency for most choices of τd and τw. Changes in τd and τw caused the frequency-averaged ABTF [quantified by apparent integrated backscatter (AIB)] and the frequency dependence of the ABTF [quantified by frequency slope of apparent backscatter (FSAB)] to change by as much as 24.6 dB and 6.7 dB/MHz, respectively. τd strongly influenced the measured values of AIB and FSAB and the correlation of AIB with bone density (-0.95 ≤ R ≤ +0.68). The correlation of FSAB with bone density was influenced less strongly by τd (-0.97 ≤ R ≤ -0.87). τw had a weaker influence than τd on the measured values of AIB and FSAB and the correlation of these parameters with bone density.


Assuntos
Densidade Óssea/fisiologia , Fêmur/diagnóstico por imagem , Fêmur/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Ondas Ultrassônicas , Ultrassonografia/métodos , Adulto , Simulação por Computador , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade
3.
J Acoust Soc Am ; 138(4): 2449-57, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26520327

RESUMO

Ultrasonic backscatter techniques are being developed to diagnose osteoporosis. Tissues that lie between the transducer and the ultrasonically interrogated region of bone may produce errors in backscatter measurements. The goal of this study is to investigate the effects of intervening tissues on ultrasonic backscatter measurements of bone. Measurements were performed on 24 cube shaped specimens of human cancellous bone using a 5 MHz transducer. Measurements were repeated after adding a 1 mm thick plate of cortical bone to simulate the bone cortex and a 3 cm thick phantom to simulate soft tissue at the hip. Signals were analyzed to determine three apparent backscatter parameters (apparent integrated backscatter, frequency slope of apparent backscatter, and frequency intercept of apparent backscatter) and three backscatter difference parameters [normalized mean backscatter difference (nMBD), normalized slope of the backscatter difference, and normalized intercept of the backscatter difference]. The apparent backscatter parameters were impacted significantly by the presence of intervening tissues. In contrast, the backscatter difference parameters were not affected by intervening tissues. However, only one backscatter difference parameter, nMBD, demonstrated a strong correlation with bone mineral density. Thus, among the six parameters tested, nMBD may be the best choice for in vivo backscatter measurements of bone when intervening tissues are present.


Assuntos
Fêmur/diagnóstico por imagem , Absorciometria de Fóton , Animais , Densidade Óssea , Quadril , Humanos , Técnicas In Vitro , Osteoporose/diagnóstico por imagem , Imagens de Fantasmas , Tíbia , Transdutores , Ultrassonografia