Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Circ Cardiovasc Imaging ; 15(7): e013869, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35861977

RESUMO

BACKGROUND: Peripheral artery disease (PAD) results in exercise-induced ischemia in leg muscles. 31Phosphorus (P) magnetic resonance spectroscopy demonstrates prolonged phosphocreatine recovery time constant after exercise in PAD but has low signal to noise, low spatial resolution, and requires multinuclear hardware. Chemical exchange saturation transfer (CEST) is a quantitative magnetic resonance imaging method for imaging substrate (CEST asymmetry [CESTasym]) concentration by muscle group. We hypothesized that kinetics measured by CEST could distinguish between patients with PAD and controls. METHODS: Patients with PAD and age-matched normal subjects were imaged at 3T with a transmit-receive coil around the calf. Four CEST mages were acquired over 24-second intervals. The subjects then performed plantar flexion exercise on a magnetic resonance imaging-compatible ergometer until calf exhaustion. Twenty-five CEST images were obtained at end exercise. Regions of interest were drawn around individual muscle groups, and (CESTasym) decay times were fitted by exponential curve to CEST values. In 10 patients and 11 controls, 31P spectra were obtained 20 minutes later after repeat exercise. Five patients and 5 controls returned at a mean of 1±1 days later for repeat CEST studies. RESULTS: Thirty-five patients with PAD (31 male, age 66±8 years) and 29 controls (11 male, age 63±8 years) were imaged with CEST. The CESTasym decay times for the whole calf (341±332 versus 153±72 seconds; P<0.03) as well as for the gastrocnemius and posterior tibialis were longer in patients with PAD. Agreement between CESTasym decay and phosphocreatine recovery time constant was good. CONCLUSIONS: CEST is a magnetic resonance imaging method that can distinguish energetics in patients with PAD from age-matched normal subjects on a per muscle group basis. CEST agrees reasonably well with the gold standard 31P magnetic resonance spectroscopy. Moreover, CEST has higher spatial resolution, creates an image, and does not require multinuclear hardware and thus may be more suitable for clinical studies in PAD.


Assuntos
Perna (Membro) , Doença Arterial Periférica , Idoso , Humanos , Perna (Membro)/irrigação sanguínea , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Músculo Esquelético , Doença Arterial Periférica/diagnóstico por imagem , Fosfocreatina
2.
Magn Reson Med ; 85(4): 2145-2159, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33174639

RESUMO

PURPOSE: Intraoperative T2 -weighted (T2-w) imaging unreliably captures image contrast specific to thermal ablation after transcranial MR-guided focused ultrasound surgery, impeding dynamic imaging feedback. Using a porcine thalamotomy model, we test the unproven hypothesis that intraoperative DWI can improve dynamic feedback by detecting lesioning within 30 minutes of transcranial MR-guided focused ultrasound surgery. METHODS: Twenty-five thermal lesions were formed in six porcine models using a clinical transcranial MR-guided focused ultrasound surgery system. A novel diffusion-weighted pulse sequence monitored the formation of T2-w and diffusion-weighted lesion contrast after ablation. Using postoperative T2-w contrast to indicate lesioning, apparent intraoperative image contrasts and diffusion coefficients at each lesion site were computed as a function of time after ablation, observed peak temperature, and observed thermal dose. Lesion sizes segmented from imaging and thermometry were compared. Image reviewers estimated the time to emergence of lesion contrast. Intraoperative image contrasts were analyzed using receiver operator curves. RESULTS: On average, the apparent diffusion coefficient at lesioned sites decreased within 5 minutes after ablation relative to control sites. In-plane lesion areas on intraoperative DWI varied from postoperative T2-w MRI and MR thermometry by 9.6±9.7 mm2 and -4.0±7.1 mm2 , respectively. The 0.25, 0.5, and 0.75 quantiles of the earliest times of observed T2-w and diffusion-weighted lesion contrast were 10.7, 21.0, and 27.8 minutes and 3.7, 8.6, and 11.8 minutes, respectively. The T2-w and diffusion-weighted contrasts and apparent diffusion coefficient values produced areas under the receiver operator curve of 0.66, 0.80, and 0.74, respectively. CONCLUSION: Intraoperative DWI can detect MR-guided focused ultrasound surgery lesion formation in the brain within several minutes after treatment.


Assuntos
Hipertermia Induzida , Cirurgia Assistida por Computador , Animais , Imagem de Difusão por Ressonância Magnética , Imageamento por Ressonância Magnética , Suínos , Tálamo
3.
Proc SPIE Int Soc Opt Eng ; 97882016 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-28855746

RESUMO

This work describes a methodology for efficient removal of scatter radiation during digital breast tomosynthesis (DBT). The goal of this approach is to enable grid image obscuration without a large increase in radiation dose by minimizing misalignment of the grid focal point (GFP) and x-ray focal spot (XFS) during grid reciprocation. Hardware for the motion scheme was built and tested on the dual modality breast tomosynthesis (DMT) scanner, which combines DBT and molecular breast tomosynthesis (MBT) on a single gantry. The DMT scanner uses fully isocentric rotation of tube and x-ray detector for maintaining a fixed tube-detector alignment during DBT imaging. A cellular focused copper prototype grid with 80 cm focal length, 3.85 mm height, 0.1 mm thick lamellae, and 1.1 mm hole pitch was tested. Primary transmission of the grid at 28 kV tube voltage was on average 74% with the grid stationary and aligned for maximum transmission. It fell to 72% during grid reciprocation by the proposed method. Residual grid line artifacts (GLAs) in projection views and reconstructed DBT images are characterized and methods for reducing the visibility of GLAs in the reconstructed volume through projection image flat-field correction and spatial frequency-based filtering of the DBT slices are described and evaluated. The software correction methods reduce the visibility of these artifacts in the reconstructed volume, making them imperceptible both in the reconstructed DBT images and their Fourier transforms.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...