Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Micromachines (Basel) ; 15(6)2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38930733

RESUMO

This paper demonstrates the potential of anisotropic 3D printing for alignable carbon nanomaterials. The ferrite-decorated nanocarbon material was synthesized via a sodium solvation process using epichlorohydrin as the coupling agent. Employing a one-pot synthesis approach, the novel material was incorporated into a 3D photopolymer, manipulated, and printed using a low-cost microscale 3D printer, equipped with digital micromirror lithography, monitoring optics, and magnetic actuators. This technique highlights the ability to control the microstructure of 3D-printed objects with sub-micron precision for applications such as microelectrode sensors and microrobot fabrication.

2.
Sensors (Basel) ; 24(11)2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38894123

RESUMO

The self-sensing technology of microactuators utilizes a smart material to concurrently actuate and sense in a closed-loop control system. This work aimed to develop a position feedback-control system of nickel electrothermal microactuators using a resistivity self-sensing technique. The system utilizes the change in heating/sensing elements' resistance, due to the Joule heat, as the control parameter. Using this technique, the heating/sensing elements would concurrently sense and actuate in a closed loop control making the structures of microactuators simple. From a series of experiments, the proposed self-sensing feedback control system was successfully demonstrated. The tip's displacement error was smaller than 3 µm out of the displacement span of 60 µm. In addition, the system was less sensitive to the abrupt temperature change in surroundings as it was able to displace the microactuator's tip back to the desired position within 5 s, which was much faster than a feed-forward control system.

3.
Ann Allergy Asthma Immunol ; 130(3): 312-316, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36436784

RESUMO

BACKGROUND: Skin prick tests (SPTs) are difficult to standardize, and SPT performance mainly relies on the clinician's expertise. So far, the effect of various factors such as device types, shape, variety of material type, and applied force on the performance of SPT has not been extensively investigated. OBJECTIVE: To investigate the effect of various factors, including type or shape of devices, material type, and applied force, on the performance of SPT. METHODS: Four SPT devices with different shapes and materials were applied on 12 subjects under 3 different applied forces (30, 45, and 60 g). The results were compared with standard method using an ALK lancet pricked by an experienced clinician. RESULTS: A total of 480 pricks were conducted on 12 subjects. The wheal sizes and sensitivities of all devices increased with higher applied forces. The thinner lancets with a long sharp tip had relatively higher analytical sensitivities and provided 100% sensitivity at applied forces of 45 g and above. The pain scores of all devices at applied forces of 30 to 60 g ranged from 1.00 to 1.81 with minimal incidences of bleeding (0%-4.17%), whereas the pain score of the standard method by the ALK lancet was 2.08 with much higher incidences of bleeding at 27.08%. CONCLUSION: The type/shape of the SPT device and applied force are the essential factors affecting the performance of SPT. The study result could pave the way toward higher performance and standardized SPT. TRIAL REGISTRATION: The Thai Clinical Trials Registry identification number: TCTR20220627004 (https://www.thaiclinicaltrials.org/show/TCTR20220627004).


Assuntos
Dor , Receptores Proteína Tirosina Quinases , Humanos , Testes Cutâneos/métodos , Desenho de Equipamento , Alérgenos
4.
Micromachines (Basel) ; 10(11)2019 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-31726665

RESUMO

Inertial separation techniques in a microfluidic system have been widely employed in the field of medical diagnosis for a long time. Despite no requirement of external forces, it requires strong hydrodynamic forces that could potentially cause cell damage or loss during the separation process. This might lead to the wrong interpretation of laboratory results since the change of structures and functional characteristics of cells due to the hydrodynamic forces that occur are not taken into account. Therefore, it is important to investigate the cell viability and damage along with the separation efficacy of the device in the design process. In this study, two inertial separation techniques-spiral microchannel and contraction-expansion array (CEA)-were examined to evaluate cell viability, morphology and intracellular structures using a trypan blue assay (TB), Scanning Electron Microscopy (SEM) and Wright-Giemsa stain. We discovered that cell loss was not significantly found in a feeding system, i.e., syringe, needle and tube, but mostly occurred in the inertial separation devices while the change of cell morphology and intracellular structures were found in the feeding system and inertial separation devices. Furthermore, percentage of cell loss was not significant in both devices (7-10%). However, the change of cell morphology was considerably increased (30%) in spiral microchannel (shear stress dominated) rather than in CEA (12%). In contrast, the disruption of intracellular structures was increased (14%) in CEA (extensional and shear stress dominated equally) rather than spiral microchannel (2%). In these experiments, leukocytes of canine were used as samples because their sizes are varied in a range between 7-12 µm, and they are commonly used as a biomarker in many clinical and medical applications.

5.
J Biomater Appl ; 33(7): 997-1010, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30757966

RESUMO

Long-term clinical success of a titanium implant not only depends upon osseointegration between implant and bone surface but also on the response of host immune cells. Following implantation of biomaterials, an inflammatory response, including T lymphocyte response, is ostensibly initiated by implant-cell interaction. However, little is known about the responses of T lymphocytes to titanium dioxide nanotubes. The present study aimed to explore the effect of titanium dioxide nanotubes on T lymphocytes in vitro and its biological consequences. The results of the present study showed that titanium dioxide nanotubes with diameter of 30-105 nm were non-cytotoxic to T lymphocytes, and the 105 nm titanium dioxide nanotube surface specifically possessed an ability to activate T lymphocytes, thus increasing DNA synthesis and cell proliferation. In addition, the 105 nm titanium dioxide nanotubes significantly activated the expression of FGF-2 gene and protein in T lymphocytes although smaller nanotubes (i.e. those with diameters of approximately 30 and 70 nm) had little effect on this. The present study investigated the mechanism by which 105 nm nanotubes stimulated FGF-2 expression in T lymphocytes by blocking key MAPK pathways. The inhibitors of JNK1/2/3 and ERK1/2 significantly inhibited 105 nm titanium dioxide nanotubes-induced FGF-2 expression. Corresponding to the increased expression of FGF-2, only the supernatant from T lymphocytes cultured on 105 nm nanotubes stimulated human mesenchymal stem cell proliferation. FGF-2 blocking antibody partially reversed the increased proliferation of human mesenchymal stem cells, supporting the role of T lymphocyte-derived FGF-2 in enhanced human mesenchymal stem cell proliferation. This suggests a significant role of T lymphocyte-titanium dioxide nanotube interaction in the proliferation of human mesenchymal stem cells, which is pivotal to the formation of new bone following implant placement.


Assuntos
Materiais Biocompatíveis/farmacologia , Fator 2 de Crescimento de Fibroblastos/genética , Células-Tronco Mesenquimais/efeitos dos fármacos , Linfócitos T/efeitos dos fármacos , Titânio/farmacologia , Materiais Biocompatíveis/química , Linhagem Celular , Proliferação de Células/efeitos dos fármacos , Células Cultivadas , Humanos , Sistema de Sinalização das MAP Quinases/efeitos dos fármacos , Células-Tronco Mesenquimais/citologia , Células-Tronco Mesenquimais/metabolismo , Nanotubos/química , Nanotubos/ultraestrutura , Linfócitos T/citologia , Linfócitos T/metabolismo , Titânio/química , Regulação para Cima/efeitos dos fármacos
6.
Micromachines (Basel) ; 9(1)2017 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-30393286

RESUMO

Our laboratory has the fundamental responsibility to study cancer stem cells (CSC) in various models of human and animal neoplasms. However, the major impediments that spike our accomplishment are the lack of universal biomarkers and cellular heterogeneity. To cope with these restrictions, we have tried to apply the concept of single cell analysis, which has hitherto been recommended throughout the world as an imperative solution pack for resolving such dilemmas. Accordingly, our first step was to utilize a predesigned spiral microchannel fabricated by our laboratory to perform size-based single cell separation using mast cell tumor (MCT) cells as a model. However, the impact of hydrodynamic shear stresses (HSS) on mechanical cell injury and viability in a spiral microchannel has not been fully investigated so far. Intuitively, our computational fluid dynamics (CFD) simulation has strongly revealed the formations of fluid shear stress (FSS) and extensional fluid stress (EFS) in the sorting system. The panel of biomedical assays has also disclosed cell degeneration and necrosis in the model. Therefore, we have herein reported the combinatorically detrimental effect of FSS and EFS on the viability of MCT cells after sorting in our spiral microchannel, with discussion on the possibly pathogenic mechanisms of HSS-induced cell injury in the study model.

7.
Malar J ; 15(1): 358, 2016 07 12.
Artigo em Inglês | MEDLINE | ID: mdl-27405995

RESUMO

The large number of deaths caused by malaria each year has increased interest in the development of effective malaria diagnoses. At the early-stage of infection, patients show non-specific symptoms or are asymptomatic, which makes it difficult for clinical diagnosis, especially in non-endemic areas. Alternative diagnostic methods that are timely and effective are required to identify infections, particularly in field settings. This article reviews conventional malaria diagnostic methods together with recently developed techniques for both malaria detection and infected erythrocyte separation. Although many alternative techniques have recently been proposed and studied, dielectrophoretic and magnetophoretic approaches are among the promising new techniques due to their high specificity for malaria parasite-infected red blood cells. The two approaches are discussed in detail, including their principles, types, applications and limitations. In addition, other recently developed techniques, such as cell deformability and morphology, are also overviewed in this article.


Assuntos
Testes Diagnósticos de Rotina/métodos , Eritrócitos/parasitologia , Malária/diagnóstico , Plasmodium/isolamento & purificação , Humanos
8.
J Mech Behav Biomed Mater ; 50: 77-81, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26116955

RESUMO

Nowadays, microneedles are attracting a lot of attention because microneedles can deliver drugs, vaccines and hormones into the body without pain unlike conventional hypodermic needles. Furthermore, microneedles are safe for self-injection and disposal. This work aims to develop novel microneedles made of a solution of polystyrene (PS) in toluene. The mechanical properties of the fabricated PS microneedles were characterized in failure strength test and skin penetration test. According to the experimental results, a PS microneedle could withstand a large force up to 1.0 N without fracturing. Owing to the superior mechanical strength, the PS microneedles could penetrate the skin without any deterioration making them a promising alternative for commercial applications.


Assuntos
Microtecnologia/instrumentação , Agulhas , Poliestirenos/química , Falha de Equipamento , Soluções , Tolueno/química
9.
Nano Lett ; 9(1): 462-6, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19099461

RESUMO

A plasmonic interference pattern can be formed when multiple surface plasmon waves overlap coherently. Utilizing a sharp edge coupling mechanism, we experimentally demonstrate plasmonic interference patterns that can be designed at will by shaping the edges in a metallic film. The patterns can also be dynamically tailored by adjusting the wavelength, the polarization, and the incident angle of the excitation light beam. Possessing the subdiffraction limited feature resolution, this dynamical manipulation method of surface plasmon patterns will have profound potentials in nanolithography, particle manipulation, and other related fields.


Assuntos
Alumínio/química , Cristalização/métodos , Modelos Químicos , Nanoestruturas/química , Nanoestruturas/ultraestrutura , Nanotecnologia/métodos , Ressonância de Plasmônio de Superfície/métodos , Simulação por Computador , Substâncias Macromoleculares/química , Teste de Materiais , Conformação Molecular , Tamanho da Partícula , Propriedades de Superfície
10.
Nat Nanotechnol ; 3(12): 733-7, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19057593

RESUMO

The commercialization of nanoscale devices requires the development of high-throughput nanofabrication technologies that allow frequent design changes. Maskless nanolithography, including electron-beam and scanning-probe lithography, offers the desired flexibility but is limited by low throughput. Here, we report a new low-cost, high-throughput approach to maskless nanolithography that uses an array of plasmonic lenses that 'flies' above the surface to be patterned, concentrating short-wavelength surface plasmons into sub-100 nm spots. However, these nanoscale spots are only formed in the near field, which makes it very difficult to scan the array above the surface at high speed. To overcome this problem we have designed a self-spacing air bearing that can fly the array just 20 nm above a disk that is spinning at speeds of between 4 and 12 m s(-1), and have experimentally demonstrated patterning with a linewidth of 80 nm. This low-cost nanofabrication scheme has the potential to achieve throughputs that are two to five orders of magnitude higher than other maskless techniques.


Assuntos
Nanotecnologia/instrumentação , Ressonância de Plasmônio de Superfície/métodos , Nanoestruturas , Nanotecnologia/métodos , Óptica e Fotônica
11.
Nano Lett ; 8(9): 3041-5, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18720976

RESUMO

Nearfield scanning optical microscopy (NSOM) offers a practical means of optical imaging, optical sensing, and nanolithography at a resolution below the diffraction limit of the light. However, its applications are limited due to the strong attenuation of the light transmitted through the subwavelength aperture. To solve this problem, we report the development of plasmonic nearfield scanning optical microscope with an efficient nearfield focusing. By exciting surface plasmons, plasmonic NSOM probes are capable of confining light into a 100 nm spot. We show by nearfield lithography experiments that the intensity at the near field is at least one order stronger than the intensity obtained from the conventional NSOM probes under the same illumination condition. Such a high efficiency can enable plasmonic NSOM as a practical tool for nearfield lithography, data storage, cellular visualization, and many other applications requiring efficient transmission with high resolution.

12.
Nat Mater ; 5(6): 452-6, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16648856

RESUMO

The emergence of artificially designed subwavelength electromagnetic materials, denoted metamaterials, has significantly broadened the range of material responses found in nature. However, the acoustic analogue to electromagnetic metamaterials has, so far, not been investigated. We report a new class of ultrasonic metamaterials consisting of an array of subwavelength Helmholtz resonators with designed acoustic inductance and capacitance. These materials have an effective dynamic modulus with negative values near the resonance frequency. As a result, these ultrasonic metamaterials can convey acoustic waves with a group velocity antiparallel to phase velocity, as observed experimentally. On the basis of homogenized-media theory, we calculated the dispersion and transmission, which agrees well with experiments near 30 kHz. As the negative dynamic modulus leads to a richness of surface states with very large wavevectors, this new class of acoustic metamaterials may offer interesting applications, such as acoustic negative refraction and superlensing below the diffraction limit.

13.
Nano Lett ; 5(9): 1726-9, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16159213

RESUMO

We report the focusing of surface plasmon polaritons by circular and elliptical structures milled into optically thick metallic films or plasmonic lenses. Both theoretical and experimental data for the electromagnetic nearfield is presented. The nearfield is mapped experimentally using nearfield scanning optical microscopy and plasmonic lithography. We find that the intensity at the focal points of the plasmonic lenses increases with size.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...