Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Biometeorol ; 62(10): 1861-1872, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30062610

RESUMO

Contact skin temperature (Tsk) sensors are calibrated under uniform thermal conditions but used in the presence of a skin-to-environment temperature gradient. We aimed to characterise the validity of contact Tsk sensors when measuring surface temperature under a range of environmental and fabric coverage conditions, to estimate practical temperature limits for a given measurement bias and to explore correcting for bias. Using two types of contact Tsk sensors (thermistors, n = 5; iButtons, n = 5), we performed experiments in three phases: (1) conventional calibration (uniform thermal environment) over 15-40 °C in 5 °C steps (at t = 0, and 24 h, 12 weeks later), (2) surface temperature measurements of a purpose-made aluminium plate (also 15-40 °C) at different environmental temperatures (15, 25, 35 °C) with different sensor attachments and fabric coverings to assess measurement bias and calculate correction factors that account for the next-to-surface microclimate temperature and (3) surface measurements (33.1 °C in 20 °C environment) for assessing generated corrections. The main results were as follows: (1) after initial calibration, Tsk sensors were valid under uniform thermal conditions [mean bias < 0.05 °C, typical error of the estimate < 0.1 °C]. (2) For the surface measurements, bias increased with increasing surface-to-microclimate temperature difference for both sensor types. The range of surface temperatures possible to remain within given bias limits could be estimated for the various conditions. (3) For a given measurement, using corrections encompassing the microclimate temperature (mean difference - 0.1 to 0.5 °C) performed better than conventional calibration alone (mean difference - 2.1 to - 0.3 °C). In conclusion, the bias of Tsk sensors is influenced by the microclimate temperature and, therefore, body coverings. Where excessive bias is expected, the validity can be improved through sensor and attachment selection and by applying corrections that account for the local temperature gradient.


Assuntos
Microclima , Temperatura Cutânea , Dispositivos Eletrônicos Vestíveis/normas , Temperatura Corporal , Calibragem , Humanos , Temperatura
2.
PLoS One ; 12(6): e0180069, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28662084

RESUMO

Due to the increasing load in backpacks and other load carriage systems over the last decades, load carriage system designs have to be adapted accordingly to minimize discomfort and to reduce the risk of injury. As subject studies are labor-intensive and include further challenges such as intra-subject and inter-subject variability, we aimed to validate an instrumented dummy as an objective laboratory tool to assess the mechanical aspects of discomfort. The validation of the instrumented dummy was conducted by comparison with a recent subject study. The mechanical parameters that characterize the static and dynamic interaction between backpack and body during different backpack settings were compared. The second aim was to investigate whether high predictive power (coefficient of determination R2>0.5) in assessing the discomfort of load carriage systems could be reached using the instrumented dummy. Measurements were conducted under static conditions, simulating upright standing, and dynamic conditions, simulating level walking. Twelve different configurations of a typical load carriage system, a commercially available backpack with a hip belt, were assessed. The mechanical parameters were measured in the shoulder and the hip region of the dummy and consisted of average pressure, peak pressure, strap force and relative motion between the system and the body. The twelve configurations consisted of three different weights (15kg, 20kg, and 25kg), combined with four different hip belt tensions (30N, 60N, 90N, and 120N). Through the significant (p<0.05) correlation of the mechanical parameters measured on the dummy with the corresponding values of the subject study, the dummy was validated for all static measurements and for dynamic measurements in the hip region to accurately simulate the interaction between the human body and the load carriage system. Multiple linear regressions with the mechanical parameters measured on the dummy as independent variables and the corresponding subjective discomfort scores from the subject study as the dependent variable revealed a high predictive power of the instrumented dummy. The dummy can explain 75% or more of the variance in discomfort using average pressures as predictors and even 79% or more of the variance in discomfort using strap forces as predictors. Use of the dummy enables objective, fast, and iterative assessments of load carriage systems and therefore reduces the need for labor-intensive subject studies in order to decrease the mechanical aspects of discomfort during load carriage.


Assuntos
Manequins , Suporte de Carga , Fenômenos Biomecânicos , Técnicas Biossensoriais , Humanos , Masculino , Movimento , Postura , Pressão , Caminhada
3.
Comput Methods Biomech Biomed Engin ; 20(5): 558-565, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27873535

RESUMO

Backpack carriage is significantly associated with a higher prevalence of low back pain. Elevated compression and shear forces in the lumbar intervertebral discs are known risk factors. A novel method of calculating the loads in the lumbar spine during backpack carriage is presented by combining physical and numerical modelling. The results revealed that to predict realistic lumbar compression forces, subject-specific lumbar curvature data were not necessary for loads up to 40 kg. In contrast, regarding shear forces, using subject-specific lumbar curvature data from upright MRI measurements as input for the rigid body model significantly altered lumbar joint force estimates.


Assuntos
Vértebras Lombares/fisiologia , Adulto , Fenômenos Biomecânicos , Força Compressiva , Humanos , Disco Intervertebral/fisiologia , Articulações/fisiologia , Imageamento por Ressonância Magnética , Masculino , Pressão , Suporte de Carga
4.
PLoS One ; 10(11): e0142004, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26529414

RESUMO

Discomfort during load carriage is a major issue for activities using backpacks (e.g. infantry maneuvers, children carrying school supplies, or outdoor sports). It is currently unclear which mechanical parameters are responsible for subjectively perceived discomfort. The aim of this study was to identify objectively measured mechanical predictors of discomfort during load carriage. We compared twelve different configurations of a typical load carriage system, a commercially available backpack with a hip belt. The pressure distribution under the hip belt and the shoulder strap, as well as the tensile force in the strap and the relative motion of the backpack were measured. Multiple linear regression analyses were conducted to investigate possible predictors of discomfort. The results demonstrate that static peak pressure, or alternatively, static strap force is a significant (p<0.001) predictor of discomfort during load carriage in the shoulder and hip region, accounting for 85% or more of the variation in discomfort. As an additional finding, we discovered that the regression coefficients of these predictors are significantly smaller for the hip than for the shoulder region. As static peak pressure is measured directly on the body, it is less dependent on the type of load carriage system than static strap force. Therefore, static peak pressure is well suited as a generally applicable, objective mechanical parameter for the optimization of load carriage system design. Alternatively, when limited to load carriage systems of the type backpack with hip belt, static strap force is the most valuable predictor of discomfort. The regionally differing regression coefficients of both predictors imply that the hip region is significantly more tolerant than the shoulder region. In order to minimize discomfort, users should be encouraged to shift load from the shoulders to the hip region wherever possible, at the same time likely decreasing the risk of low back pain or injury.


Assuntos
Dor nas Costas/fisiopatologia , Cartilagem/fisiopatologia , Modelos Biológicos , Pressão , Coluna Vertebral/fisiopatologia , Adulto , Humanos , Masculino , Suporte de Carga
5.
Biomaterials ; 32(17): 4096-108, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21411138

RESUMO

The angiogenic properties of micron-sized (m-BG) and nano-sized (n-BG) bioactive glass (BG) filled poly(D,L lactide) (PDLLA) composites were investigated. On the basis of cell culture work investigating the secretion of vascular endothelial growth factor (VEGF) by human fibroblasts in contact with composite films (0, 5, 10, 20 wt %), porous 3D composite scaffolds, optimised with respect to the BG filler content capable of inducing angiogenic response, were produced. The in vivo vascularisation of the scaffolds was studied in a rat animal model and quantified using stereological analyses. The prepared scaffolds had high porosities (81-93%), permeability (k = 5.4-8.6 x 10⁻9 m²) and compressive strength values (0.4-1.6 MPa) all in the range of trabecular bone. On composite films containing 20 wt % m-BG or n-BG, human fibroblasts produced 5 times higher VEGF than on pure PDLLA films. After 8 weeks of implantation, m-BG and n-BG containing scaffolds were well-infiltrated with newly formed tissue and demonstrated higher vascularisation and percentage blood vessel to tissue (11.6-15.1%) than PDLLA scaffolds (8.5%). This work thus shows potential for the regeneration of hard-soft tissue defects and increased bone formation arising from enhanced vascularisation of the construct.


Assuntos
Indutores da Angiogênese/química , Vidro/química , Poliésteres/química , Alicerces Teciduais , Fator A de Crescimento do Endotélio Vascular/metabolismo , Animais , Regeneração Óssea , Osso e Ossos/metabolismo , Osso e Ossos/patologia , Diferenciação Celular , Proliferação de Células , Sobrevivência Celular , Células Cultivadas , Cerâmica , Força Compressiva , Ensaio de Imunoadsorção Enzimática , Fibroblastos/citologia , Fibroblastos/metabolismo , Humanos , Implantes Experimentais , Microscopia Eletrônica de Varredura , Neovascularização Fisiológica , Porosidade , Ratos , Ratos Sprague-Dawley
6.
Br J Sports Med ; 44(11): 822-6, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20647300

RESUMO

OBJECTIVE: Back protectors for snowboarders were analysed with respect to their potential to prevent spinal injury. DESIGN: In 20 Swiss skiing resorts, athletes were interviewed on the slope. In addition, an online survey was conducted. The performance of 12 commercially available back protectors was investigated by means of mechanical testing. A currently used drop test according to standard EN1621 (motorcycle protectors), testing energy damping was supplemented by penetration tests according to standard EN1077, which reflects snowsport safety concerns. RESULTS: 6 out of 12 back protectors fulfilled the higher safety level defined in EN1621. Protectors making use of energy-absorbing layers performed particularly well. In contrast, hard shell protectors exhibited a higher potential to withstand the penetration test. The surveys confirmed that approximately 40-50% of snowboarders use a back protector. A large majority of users expect protection from severe spinal injury such as vertebral fractures or spinal cord injury. CONCLUSIONS: The currently used test standards are fulfilled by many back protectors. Users, however, expect protectors to be efficient in impact scenarios that result in spinal injury, which are more severe than impacts as addressed in the current standards. This study highlights that there is a mismatch between the capabilities of current back protectors to prevent spinal injury in snowboarding and the expectations users have of these protectors.


Assuntos
Equipamentos de Proteção , Recreação , Esqui/lesões , Traumatismos da Coluna Vertebral/prevenção & controle , Adolescente , Adulto , Idoso , Criança , Desenho de Equipamento , Feminino , Humanos , Masculino , Teste de Materiais/métodos , Pessoa de Meia-Idade , Adulto Jovem
7.
Int J Occup Saf Ergon ; 14(1): 55-60, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18394326

RESUMO

Heat and mechanical protection properties of 6 fabric combinations commonly used in firefighters' protective clothing were assessed before and after different heat treatment. It was shown that after heat exposure, the values obtained were generally lower than in the original state. The mechanical properties of the materials were more affected by heat than by heat protective properties. In 2 cases, degradation started before a visible change in the material could be observed, which might be potentially dangerous for the end user who will not realize the alteration of the material.


Assuntos
Incêndios , Temperatura Alta/efeitos adversos , Roupa de Proteção , Trabalho de Resgate , Falha de Equipamento , Humanos , Teste de Materiais/métodos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...