Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Undersea Hyperb Med ; 49(4): 459-465, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36446291

RESUMO

Purpose: In a disabled submarine scenario, a pressurized rescue module (PRM) may be deployed to rescue survivors. If the PRM were to become disabled, conditions could become hot and humid exposing the occupants to heat stress. We tested the hypothesis that the rise in core temperature and fluid loss from sweating would increase with rising dry bulb temperature. Methods: Twelve males (age 22 ± 3 years; height 179 ± 7 cm; mass 77.4 ± 8.3 kg) completed this study. On three occasions, subjects were exposed to high humidity and either 28-, 32-, or 35˚C for six hours in a dry hyperbaric chamber pressurized to 6.1 msw. Changes in core temperature (Tc) and body mass were recorded and linear regression lines fit to estimate the predicted rise in Tc and loss of fluid from sweating. Results: Heart rate was higher in the 35°C condition compared to the 28°C and 32°C conditions. Tc was higher in the 32°C condition compared to 28°C and higher in 35°C compared to the 28˚°C and 32°C conditions. Projected fluid loss in all of the tested conditions could exceed 6% of body mass after 24 hours of exposure endangering the health of sailors in a DISSUB or disabled PRM. A fluid intake of 1.0 to 3.5 L would be required to limit dehydration to 2% or 4% of initial mass depending upon condition. Conclusions: Prolonged exposure to 35°C conditions under pressure results in uncompensable heat stress. 32°C and 35°C exposures were compensable under these conditions but further research is required to elucidate the effect of increased ambient pressure on thermoregulation.


Assuntos
Estatura , Regulação da Temperatura Corporal , Masculino , Humanos , Adulto Jovem , Adulto , Umidade , Frequência Cardíaca , Modelos Lineares
2.
J Emerg Med ; 62(1): 64-71, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34544622

RESUMO

BACKGROUND: Ultrasound inferior vena cava (IVC) diameter has been shown to decrease in response to hemorrhage. IVC diameter cut points to identify moderate and severe blood loss have not been established. OBJECTIVES: This study sought to find ultrasound IVC diameter cut points to identify moderate and severe hemorrhage and assess the performance of these cut points vs. vital sign abnormalities. METHODS: This is a secondary analysis of data from a study that described changes in vital signs and sonographic measurements of the IVC during a lower body negative pressure model of hemorrhage. Using receiver operator curve analyses, optimal cut points for identifying moderate and severe hemorrhage were identified. The ability of these cut points to identify hemorrhage in patients with no vital sign abnormalities was then assessed. RESULTS: In both long- and short-axis views, maximum and minimum IVC diameters (IVCmax and IVCmin) were significantly lower than baseline in severe blood loss. The optimal cut point for IVCmax in both axes was found to be ≤ 0.8 cm. This cut point is able to distinguish between no blood loss vs. moderate blood loss, and no blood loss vs. severe blood loss. The optimal cut point for IVCmin was variable between axes and blood loss severity. IVC diameter cut points obtained were able to identify hemorrhage in patients with no vital sign abnormalities. CONCLUSION: An ultrasound IVCmax of ≤ 0.8 cm may be useful in identifying moderate and severe hemorrhage before vital sign abnormalities are evident.


Assuntos
Abdome , Veia Cava Inferior , Hemorragia/etiologia , Humanos , Ultrassonografia , Veia Cava Inferior/diagnóstico por imagem , Sinais Vitais
3.
Undersea Hyperb Med ; 48(4): 469-476, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34847312

RESUMO

Exposure to a reduction in ambient pressure such as in high-altitude climbing, flying in aircrafts, and decompression from underwater diving results in circulating vascular gas bubbles (i.e., venous gas emboli [VGE]). Incidence and severity of VGE, in part, can objectively quantify decompression stress and risk of decompression sickness (DCS) which is typically mitigated by adherence to decompression schedules. However, dives conducted at altitude challenge recommendations for decompression schedules which are limited to exposures of 10,000 feet in the U.S. Navy Diving Manual (Rev. 7). Therefore, in an ancillary analysis within a larger study, we assessed the evolution of VGE for two hours post-dive using echocardiography following simulated altitude dives at 12,000 feet. Ten divers completed two dives to 66 fsw (equivalent to 110 fsw at sea level by the Cross correction method) for 30 minutes in a hyperbaric chamber. All dives were completed following a 60-minute exposure at 12,000 feet. Following the dive, the chamber was decompressed back to altitude for two hours. Echocardiograph measurements were performed every 20 minutes post-dive. Bubbles were counted and graded using the Germonpré and Eftedal and Brubakk method, respectively. No diver presented with symptoms of DCS following the dive or two hours post-dive at altitude. Despite inter- and intra-diver variability of VGE grade following the dives, the majority (11/20 dives) presented a peak VGE Grade 0, three VGE Grade 1, one VGE Grade 2, four VGE Grade 3, and one VGE Grade 4. Using the Cross correction method for a 66-fsw dive at 12,000 feet of altitude resulted in a relatively low decompression stress and no cases of DCS.

4.
Am J Physiol Regul Integr Comp Physiol ; 321(2): R197-R207, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-34133244

RESUMO

Tonic carotid body (CB) activity is reduced during exposure to cold and hyperoxia. We tested the hypotheses that cold water diving lowers CB chemosensitivity and augments CO2 retention more than thermoneutral diving. Thirteen subjects [age: 26 ± 4 yr; body mass index (BMI): 26 ± 2 kg/m2) completed two 4-h head-out water immersion protocols in a hyperbaric chamber (1.6 ATA) in cold (15°C) and thermoneutral (25°C) water. CB chemosensitivity was assessed with brief hypercapnic ventilatory response ([Formula: see text]) and hypoxic ventilatory response ([Formula: see text]) tests before dive, 80 and 160 min into the dive (D80 and D160, respectively), and immediately after and 60 min after dive. Data are reported as an absolute mean (SD) change from predive. End-tidal CO2 pressure increased during both the thermoneutral water dive [D160: +2 (3) mmHg; P = 0.02] and the cold water dive [D160: +1 (2) mmHg; P = 0.03]. Ventilation increased during the cold water dive [D80: 4.13 (4.38) and D160: 7.75 (5.23) L·min-1; both P < 0.01] and was greater than the thermoneutral water dive at both time points (both P < 0.01). [Formula: see text] was unchanged during the dive (P = 0.24) and was not different between conditions (P = 0.23). [Formula: see text] decreased during the thermoneutral water dive [D80: -3.45 (3.61) and D160: -2.76 (4.04) L·min·mmHg-1; P < 0.01 and P = 0.03, respectively] but not the cold water dive. However, [Formula: see text] was not different between conditions (P = 0.17). In conclusion, CB chemosensitivity was not attenuated during the cold stress diving condition and does not appear to contribute to changes in ventilation or CO2 retention.


Assuntos
Dióxido de Carbono/sangue , Corpo Carotídeo/fisiopatologia , Temperatura Baixa , Reflexo de Mergulho , Mergulho , Hipercapnia/fisiopatologia , Hipóxia/fisiopatologia , Pulmão/fisiopatologia , Ventilação Pulmonar , Adulto , Corpo Carotídeo/metabolismo , Hemodinâmica , Humanos , Hipercapnia/sangue , Hipóxia/sangue , Imersão , Masculino , Oxigênio/sangue , Adulto Jovem
5.
Undersea Hyperb Med ; 48(2): 107-117, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33975401

RESUMO

Introduction: Pre-dive altitude exposure may increase respiratory fatigue and subsequently augment exercise ventilation at depth. This study examined pre-dive altitude exposure and the efficacy of resistance respiratory muscle training (RMT) on respiratory fatigue while diving at altitude. Methods: Ten men (26±5 years; VO2peak: 39.8±3.3 mL• kg-1•min-1) performed three dives; one control (ground level) and two simulated altitude dives (3,658 m) to 17 msw, relative to ground level, before and after four weeks of resistance RMT. Subjects performed pulmonary function testing (e.g., inspiratory [PI] and expiratory [PE] pressure testing) pre- and post-RMT and during dive visits. During each dive, subjects exercised for 18 minutes at 55% VO2peak, and ventilation (VE), breathing frequency (ƒb,), tidal volume (VT) and rating of perceived exertion (RPE) were measured. Results: Pre-dive altitude exposure reduced PI before diving (p=0.03), but had no effect on exercise VE, ƒb, or VT at depth. At the end of the dive in the pre-RMT condition, RPE was lower (p=0.01) compared to control. RMT increased PI and PE (p<0.01). PE was reduced from baseline after diving at altitude (p<0.03) and this was abated after RMT. RMT did not improve VE or VT at depth, but decreased ƒb (p=0.01) and RPE (p=0.048) during the final minutes of exercise. Conclusion: Acute altitude exposure pre- and post-dive induces decrements in PI and PE before and after diving, but does not seem to influence ventilation at depth. RMT reduced ƒb and RPE during exercise at depth, and may be useful to reduce work of breathing and respiratory fatigue during dives at altitude.


Assuntos
Altitude , Exercícios Respiratórios/métodos , Mergulho/fisiologia , Exercício Físico/fisiologia , Fadiga Muscular/fisiologia , Trabalho Respiratório/fisiologia , Adulto , Análise de Variância , Exposição Ambiental , Expiração/fisiologia , Frequência Cardíaca , Humanos , Inalação/fisiologia , Masculino , Oxigênio/sangue , Consumo de Oxigênio/fisiologia , Esforço Físico/fisiologia , Treinamento Resistido/métodos , Testes de Função Respiratória , Volume de Ventilação Pulmonar/fisiologia , Fatores de Tempo
6.
Undersea Hyperb Med ; 48(2): 119-126, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33975402

RESUMO

Exposure to a reduction in ambient pressure such as in high-altitude climbing, flying in aircrafts, and decompression from underwater diving results in circulating vascular gas bubbles (i.e., venous gas emboli [VGE]). Incidence and severity of VGE, in part, can objectively quantify decompression stress and risk of decompression sickness (DCS) which is typically mitigated by adherence to decompression schedules. However, dives conducted at altitude challenge recommendations for decompression schedules which are limited to exposures of 10,000 feet in the U.S. Navy Diving Manual (Rev. 7). Therefore, in an ancillary analysis within a larger study, we assessed the evolution of VGE for two hours post-dive using echocardiography following simulated altitude dives at 12,000 feet. Ten divers completed two dives to 66 fsw (equivalent to 110 fsw at sea level by the Cross correction method) for 30 minutes in a hyperbaric chamber. All dives were completed following a 60-minute exposure at 12,000 feet. Following the dive, the chamber was decompressed back to altitude for two hours. Echocardiograph measurements were performed every 20 minutes post-dive. Bubbles were counted and graded using the Germonpré and Eftedal and Brubakk method, respectively. No diver presented with symptoms of DCS following the dive or two hours post-dive at altitude. Despite inter- and intra-diver variability of VGE grade following the dives, the majority (11/20 dives) presented a peak VGE Grade 0, three VGE Grade 1, one VGE Grade 2, four VGE Grade 3, and one VGE Grade 4. Using the Cross correction method for a 66-fsw dive at 12,000 feet of altitude resulted in a relatively low decompression stress and no cases of DCS.


Assuntos
Altitude , Mergulho/fisiologia , Embolia Aérea/diagnóstico por imagem , Adulto , Pressão Atmosférica , Exercícios Respiratórios , Descompressão/métodos , Descompressão/estatística & dados numéricos , Doença da Descompressão/etiologia , Doença da Descompressão/prevenção & controle , Ecocardiografia , Embolia Aérea/etiologia , Humanos , Masculino , Valores de Referência , Água do Mar , Treinamento por Simulação , Fatores de Tempo
7.
Prehosp Emerg Care ; 25(3): 341-346, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32628063

RESUMO

INTRODUCTION: Inferior vena cava (IVC) diameter decreases under conditions of hypovolemia. Point-of-care ultrasound (POCUS) may be useful to emergently assess IVC diameter. This study tested the hypothesis that ultrasound measurements of IVC diameter decreases during severe simulated blood loss. METHODS: Blood loss was simulated in 14 healthy men (22 ± 2 years) using lower body negative pressure (LBNP). Pressure within the LBNP chamber was reduced 10 mmHg of LBNP every four minutes until participants experienced pre-syncopal symptoms or until 80 mmHg of LBNP was completed. IVC diameter was imaged with POCUS using B-mode in the long and short axis views between minutes two and four of each stage. RESULTS: Maximum IVC diameter in the long axis view was lower than baseline (1.5 ± 0.4 cm) starting at -20 mmHg of LBNP (1.0 ± 0.3 cm; p < 0.01) and throughout LBNP (p < 0.01). The minimum IVC diameter in the long axis view was lower than baseline (0.9 ± 0.3 cm) at -20 mmHg of LBNP (0.5 ± 0.3 cm; p < 0.01) and throughout LBNP (p < 0.01). Maximum IVC diameter in the short axis view was lower than baseline (0.9 ± 0.2 cm) at 40 mmHg of LBNP (0.6 ± 0.2; p = 0.01) and the final LBNP stage (0.6 ± 0.2 cm; p < 0.01). IVC minimum diameter in the short axis view was lower than baseline (0.5 ± 0.2 cm) at the final LBNP stage (0.3 ± 0.2 cm; p = 0.01). CONCLUSION: These data demonstrate that IVC diameter decreases prior to changes in traditional vital signs during simulated blood loss. Further study is needed to determine the view and diameter threshold that most accurate for identifying hemorrhage requiring emergent intervention.


Assuntos
Serviços Médicos de Emergência , Hipovolemia , Hemorragia/diagnóstico por imagem , Humanos , Pressão Negativa da Região Corporal Inferior , Masculino , Veia Cava Inferior/diagnóstico por imagem
8.
Aerosp Med Hum Perform ; 91(10): 776-784, 2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-33187563

RESUMO

INTRODUCTION: Hypoxia-induced hyperventilation is an effect of acute altitude exposure, which may lead to respiratory muscle fatigue and secondary locomotor muscle fatigue. The purpose of this study was to determine if resistive and/or endurance respiratory muscle training (RRMT and ERMT, respectively) vs. placebo respiratory muscle training (PRMT) improve cycling performance at altitude.METHODS: There were 24 subjects who were assigned to PRMT (N 8), RRMT (N 8), or ERMT (N 8). Subjects cycled to exhaustion in a hypobaric chamber decompressed to 3657 m (12,000 ft) at an intensity of 55% sea level maximal oxygen consumption (Vo2max) before and after respiratory muscle training (RMT). Additionally, subjects completed a Vo2max, pulmonary function, and respiratory endurance test (RET) before and after RMT. All RMT protocols consisted of three 30-min training sessions per week for 4 wk.RESULTS: The RRMT group increased maximum inspiratory (PImax) and expiratory (PEmax) mouth pressure after RMT (PImax: 117.7 11.6 vs. 162.6 20.0; PEmax: 164.0 33.2 vs. 216.5 44.1 cmH2O). The ERMT group increased RET after RMT (5.2 5.2 vs.18.6 16.9 min). RMT did not improve Vo2max in any group. Both RRMT and ERMT groups increased cycling time to exhaustion (RRMT: 35.9 17.2 vs. 45.6 22.2 min and ERMT: 33.8 9.6 vs. 42.9 27.0 min).CONCLUSION: Despite different improvements in pulmonary function, 4 wk of RRMT and ERMT both improved cycle time to exhaustion at altitude.Wheelock CE, Hess HW, Johnson BD, Schlader ZJ, Clemency BM, St. James E, Hostler D. Endurance and resistance respiratory muscle training and aerobic exercise performance in hypobaric hypoxia. Aerosp Med Hum Perform. 2020; 91(10):776784.


Assuntos
Exercícios Respiratórios , Resistência Física , Exercício Físico , Teste de Esforço , Humanos , Hipóxia , Consumo de Oxigênio , Músculos Respiratórios
9.
Clin Pract Cases Emerg Med ; 2(2): 132-135, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29849232

RESUMO

We present three cases of hand injury by intravenous drug users in which point-of-care ultrasound, using a specific water bath technique, was able to quickly and efficiently delineate severity of injury. This technique benefited these patients by allowing a painless assessment of their injury for soft tissue injury vs. abscess formation and allowed providers to determine at the bedside whether these patients required immediate surgical intervention.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...