RESUMO
BACKGROUND: The aim of this retrospective analysis was to evaluate the clinical feasibility of the supraclavicular ultrasound-guided cannulation of the brachiocephalic vein in infants weighing less than 1500 g. METHODS: The ultrasound probe was placed in the supraclavicular region so as to obtain the optimum sonographic long-axis view of the brachiocephalic vein. By using an in-plane approach the brachiocephalic vein was cannulated by using a 24-gauge intravenous cannula under real-time ultrasound guidance into the vein followed by the insertion of a 2-French single lumen catheter using the Seldinger technique. RESULTS: Forty-six brachiocephalic vein cannulations in infants weighing between 0.55 and 1.5 kg (Median: 1.2; 95%-CI: 0.9-1.2) were included. Ultimate success rate was 89.1% (41 out of 46). One cannulation attempt was required in 30 (65.2%) patients, 2 in 6 (13%) and 3 in 5 (10.8%), respectively. Smaller weight babies did not require significantly more cannulation attempts. The probability of successful cannulation on the first attempt increased significantly from 40% (2010) to more than 80% (2019) over the time course of this series. Median catheter dwell time was 15 days (95%-CI: 9-20) with one catheter being removed prematurely after 8 days due to obstruction. CONCLUSION: Supracalvicular in-plane real-time ultrasound-guided cannulation of the brachiocephalic vein seems to be a convenient and feasible option to provide large-bore central venous access for very small and sick babies.
Assuntos
Veias Braquiocefálicas , Cateterismo Venoso Central , Veias Braquiocefálicas/diagnóstico por imagem , Estudos de Viabilidade , Humanos , Lactente , Estudos Retrospectivos , Ultrassonografia de IntervençãoRESUMO
BACKGROUND: The aim of this retrospective analysis was to evaluate the clinical effectiveness of the supraclavicular ultrasound-guided cannulation of the brachiocephalic vein in preterm infants. METHODS: The ultrasound probe was placed in the supraclavicular region so as to obtain the optimum sonographic long-axis view of the brachiocephalic vein. By using a strict in-plane approach the brachiocephalic vein was cannulated by advancing a 22- or 24-gauge iv cannula from lateral to medial under the long axis of the ultrasound probe under real-time ultrasound guidance into the vein. RESULTS: One hundred and forty-two cannulations in infants weighing between 0.59 and 2.5 kg (median: 2.1; CI: 2.0 to 2.2) were included. Ultimate success rate was 94% (134 of 142). One cannulation attempt was required in 100 (70%) patients, two attempts in 21 (15%), and three attempts in 13 (9%). The smaller the weight of the infant the more attempts were needed. More attempts also were needed for the right brachiocephalic vein, which was primarily targeted in 75 (53%) neonates. One (1%) inadvertent arterial puncture was noted. CONCLUSIONS: This supraclavicular, in-plane, real-time, ultrasound-guided cannulation of the brachiocephalic vein seems to be a convenient and effective method to insert central venous catheters in preterm infants.