Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
Br J Radiol ; 89(1064): 20160174, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27245139

RESUMO

OBJECTIVE:: To compare electrocardiographic (ECG)-triggered high-pitch (HP) dual-source CT angiography (CTA) with non-ECG-triggered HP CTA of the aorta, particularly the ascending aorta, with regard to image quality, motion artefacts, contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR) and radiation dose. METHODS:: 59 consecutive patients who had been referred for CTA for known or suspected aortic disease, previous aortic intervention or planned transapical or transfemoral aortic valve implantation were prospectively included. Patients underwent CTAs with HP, using a dual-source CTA system, with [control group (Group A); n = 30] or without (Group B; n = 29) ECG triggering after randomization. For evaluation, image quality and a motion artefact score (MAS) were assessed in a blinded fashion at different predefined anatomic regions. CNR and SNR were measured at the same levels. Radiation dose estimates and contrast enhancement were compared between the two groups. RESULTS:: There were no significant differences for image quality and MAS. The intra-arterial contrast resolution was significantly higher at the level of the aortic arch and descending aorta in the non-triggered group (CNR values, p = 0.002-0.018). No significant differences in the radiation dose were found. CONCLUSION:: Non-triggered HP dual-source CTA provided comparable results with regard to image quality, MAS, CNR, SNR and radiation doses compared with ECG-triggered HP CTA. Therefore, ECG triggering of the ascending aorta might be obviated when HP scanning is available. ADVANCES IN KNOWLEDGE:: HP dual-source CTA might obviate ECG triggering in the ascending aorta. Non-triggered HP CTA of the ascending aorta provides an excellent image quality.

2.
J Thorac Imaging ; 29(3): 163-72, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24576836

RESUMO

The need for functional estimation of the relevance of stenosis to guide appropriate treatment in coronary artery disease has recently been shown. Invasive coronary angiography (CA) with invasive measurement of the pressure gradient in patients with coronary stenoses becomes the method of choice for treatment decision-making in invasive cardiology. Coronary computed tomography angiography (CCTA) was established several years ago as a noninvasive alternative to invasive CA; it is used primarily to exclude coronary artery disease and has shown a very high negative predictive value in this regard. During the last several years, in an effort to obtain functional information, CCTA has received much attention. The rationale for this is that with the functional information provided by CT, the positive predictive value for "relevant" stenoses should be improved. In this article, the history and limitations of anatomic grading of coronary stenoses will be discussed. Furthermore, shifts in the treatment paradigm in modern cardiology will be introduced, as well as an overview of the currently used invasive methods to assess the "relevance" of stenosis. The current role and still-existing limitations of CCTA, as well as the systematic problems in comparing CA and CCTA, are addressed. As CCTA is a highly innovative technique, new innovations are currently under clinical evaluation, including myocardial perfusion imaging, attenuation gradient measurement, and assessment of fractional flow reserve with CT. This review article will mainly focus on the technical background of these techniques and the status of their clinical implementation and will attempt to provide some suppositions about the possible future role of these new innovations.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Tomografia Computadorizada por Raios X/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Meios de Contraste , Previsões , Hemodinâmica , Humanos , Valor Preditivo dos Testes
3.
Eur J Radiol ; 81(5): 1029-33, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-21752567

RESUMO

BACKGROUND: The aim of this retrospective study was to compare the diagnostic accuracy, the frequency of complications, the duration of the interventions and the radiation doses of CT fluoroscopy (CTF) guided biopsies of lung lesions with those of multislice CT (MS-CT) biopsy mode-guided biopsies. METHODS: Data and images from 124 consecutive patients undergoing CTF-guided lung biopsy (group A) and 132 MS-CT-biopsy mode-guided lung biopsy (group B) were reviewed. CTF-guided biopsies were performed on a Siemens Emotion 6 CT scanner with intermittent or continuous CT-fluoroscopy, MS-CT biopsy mode-guided biopsies were performed on a Siemens Emotion 16 CT scanner. All biopsies were performed with a coaxial needle technique. RESULTS: The two groups (A vs. B) did not differ significantly regarding sensitivity (95.5% vs. 95.9%), specificity (96.7% vs. 95.5%), negative predictive value (87.9% vs. 84%) or positive predictive value (98.8% vs. 98.9%). Pneumothorax was observed in 30.0% and 32.5% of the patients, respectively. Chest tube placement was necessary in 4% (group A) and 13% (group B) of the patients. The duration of the intervention was significantly longer in group A (median 37 min vs. 32 min, p=0.04). The mean CT dose index (CTDI) was 422 in group A and 36.3 in group B (p<0.001). CONCLUSION: Compared to CTF-guided biopsies, chest biopsies using the MS-CT biopsy mode show dramatically lower CTDI levels. Although the diagnostic yield of the procedures do not differ significantly, biopsies using the MS-CT-biopsy mode have a three-fold higher rate of chest tube placement.


Assuntos
Biópsia/estatística & dados numéricos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/epidemiologia , Doses de Radiação , Radiografia Intervencionista/estatística & dados numéricos , Cirurgia Assistida por Computador/estatística & dados numéricos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Áustria/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Prevalência , Radiometria , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
4.
Eur J Radiol ; 81(4): e585-90, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21820829

RESUMO

PURPOSE: To compare ECG-gated and non-gated CT angiography of the aorta at the same radiation dose, with regard to motion artifacts (MA), diagnostic confidence (DC) and signal-to-noise-ratios (SNRs). MATERIALS AND METHODS: Sixty consecutive patients prospectively randomized into two groups underwent 64-row CT angiography, with or without dose-modulated ECG-gating, of the entire aorta, due to several pathologies of the ascending aorta. MA and DC were both assessed using a four-point scale. SNRs were calculated by dividing the mean enhancement by the standard deviation. The dose-length-product (DLP) of each examination was recorded and the effective dose was estimated. RESULTS: Dose-modulated ECG-gating showed statistically significant advantages over non-gated CT angiography, with regard to MA (p<0.001) and DC (p<0.001), at the aortic valve, at the origin of the coronary arteries, and at the dissection membrane, with a significant correlation (p<0.001) between MA and DC. At the aortic wall, however, ECG-gated CT angiography showed statistically significant fewer MA (p<0.001), but not a statistically significant higher DC (p=0.137) compared to non-gated CT angiography. At the supra-aortic vessels and the descending aorta, the ECG-triggering showed no statistically significant differences with regard to MA (p=0.861 and 0.526, respectively) and DC (p=1.88 and 0.728, respectively). The effective dose of ECG-gated CT angiography (23.24mSv; range, 18.43-25.94mSv) did not differ significantly (p=0.051) from that of non-gated CT angiography (24.28mSv; range, 19.37-29.27mSv). CONCLUSION: ECG-gated CT angiography of the entire aorta reduces MA and results in a higher DC with the same SNR, compared to non-gated CT angiography at the same radiation dose.


Assuntos
Algoritmos , Angiografia/métodos , Aortografia/métodos , Artefatos , Técnicas de Imagem de Sincronização Cardíaca/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Carga Corporal (Radioterapia) , Humanos , Pessoa de Meia-Idade , Movimento , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído
5.
Eur Radiol ; 21(10): 2158-65, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21556908

RESUMO

OBJECTIVE: The aim of this study was to assess whether visualisation of in-stent changes can be improved with high-resolution, steady-state, blood pool contrast-enhanced MR angiography compared with first-pass MR angiography. Intra-arterial digital subtraction angiography (DSA) served as the reference standard. METHODS: Twenty patients after stent placement in the superficial femoral artery (SFA) underwent MRA prior to reintervention. MRA of the SFA includes first-pass MRA as well as 3D high-resolution MRA in the steady state (SS-MRA) after injection of Gadofosveset trisodium. Sensitivity and specificity values for the detection of significant in-stent lesions by means of SS-MRA were calculated at the proximal, middle and distal stent segments in comparison to DSA. Kappa statistics were used to determine agreement between the two techniques. RESULTS: Sensitivity and specificity values for the detection of significant stenosis with SS-MRA reached 95% in the proximal, 100% in the middle and 100% in the distal stent segment. Kappa coefficients between SS-MRA and DSA were 0.789, 0.797 and 0.859 for the proximal, middle and distal segments, whereas the Kappa coefficients for FP-MRA were 0,211, 0,200 and 0,594 in these segments, respectively. CONCLUSION: Detection of in stent stenosis is significantly improved using SS MRA, in comparison to state-of-the-art FP-MRA.


Assuntos
Angiografia por Ressonância Magnética/métodos , Doença Arterial Periférica/patologia , Idoso , Idoso de 80 Anos ou mais , Constrição Patológica , Meios de Contraste/farmacologia , Feminino , Gadolínio/farmacologia , Imagem do Acúmulo Cardíaco de Comporta/métodos , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos/farmacologia , Sensibilidade e Especificidade , Stents
6.
AJR Am J Roentgenol ; 193(3): 787-94, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19696293

RESUMO

OBJECTIVE: The purpose of this study was to compare 64-MDCT scanners from four vendors in the in vitro evaluation of coronary artery stents. MATERIALS AND METHODS: Twelve coronary artery stents (nominal outer diameter, 2.5-5.0 mm) oriented in the z-axis were placed in a combined cardiac-chest phantom and imaged with 64-MDCT scanners from four vendors. Quantitative image quality parameters, including artificial in-stent luminal narrowing, image noise, and artificial in-stent luminal attenuation were measured on longitudinal and axial reformations. Imaging of stents with a luminal diameter of 3 mm or less and that of stents with a diameter greater than 3 mm also were compared. RESULTS: Artificial in-stent luminal narrowing was not different among the four vendors (range, 37-42%) on longitudinal reformations. Image noise inside the stent was significantly greater for one vendor (Siemens Healthcare; SD, 48 HU) than for the others (SD range, 21-26 HU) on longitudinal but not on axial images. For the same vendor, artificial in-stent luminal attenuation was significantly lower than for the other vendors. For all vendors, image noise inside the stent was significantly greater on axial than on longitudinal reformations (p < 0.001), and artificial luminal attenuation was significantly greater for all but one vendor (GE Healthcare). Stents 3 mm and narrower had significantly greater artificial luminal narrowing and artificial luminal attenuation (p < 0.05) than those with a diameter greater than 3 mm. CONCLUSION: For longitudinal reformations, scanners from the four leading vendors do not differ in artificial luminal narrowing, but there are differences in artificial luminal attenuation and image noise. The quality of images of the in-stent lumen is better on longitudinal reformations and for stents with a diameter greater than 3 mm. Except for image noise, differences between axial and longitudinal reformations are vendor specific.


Assuntos
Angiografia Coronária , Stents , Tomografia Computadorizada por Raios X , Análise de Variância , Meios de Contraste , Humanos , Técnicas In Vitro , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador
7.
AJR Am J Roentgenol ; 192(5): 1416-24, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19380571

RESUMO

OBJECTIVE: The purpose of this study was to assess the value of MDCT angiography in the development of strategies for the treatment of patients with critical limb ischemia. MATERIALS AND METHODS: During a 12-month period, 150 patients were referred to our department for CT angiography of the peripheral arteries. All patients (n = 28) with clinical stage IV peripheral arterial occlusive disease were included in this retrospective study. The treatment reports, discharge summaries, and follow-up examinations were reviewed to ascertain the number of patients correctly treated on the basis of the CT angiographic findings. RESULTS: After CT angiography, endovascular treatment was indicated for eight patients, surgical revascularization for four patients, and a combined endovascular and surgical approach for two patients. That the correct treatment decision had been made in all 14 cases was confirmed on the basis of successful endovascular or surgical revascularization. In eight patients, medical treatment was indicated, and one patient underwent amputation at the level of the thigh. Five patients were referred for complementary digital subtraction angiography, but no additional findings were made. During follow-up, three of the original 28 patients were in grave general condition and died within 7 weeks after CT angiography. Thirteen patients needed no additional treatment during the follow-up period through January 2008. After a median treatment-free interval of 381 days, 12 patients underwent additional revascularization because of clinical progression of disease. CONCLUSION: MDCT angiographic findings lead to accurate recommendations for the management of critical limb ischemia. Thus CT angiography seems to be an important technique for the management of stage IV peripheral arterial occlusive disease in patients without absolute contraindications to CT angiography.


Assuntos
Angiografia/métodos , Arteriopatias Oclusivas/diagnóstico por imagem , Perna (Membro)/irrigação sanguínea , Doenças Vasculares Periféricas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Arteriopatias Oclusivas/terapia , Progressão da Doença , Feminino , Humanos , Perna (Membro)/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Doenças Vasculares Periféricas/terapia , Retratamento , Estudos Retrospectivos , Resultado do Tratamento
8.
AJR Am J Roentgenol ; 191(4): 1122-8, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18806154

RESUMO

OBJECTIVE: The purpose of our study was to retrospectively evaluate the sonographic, CT, and MRI findings (number, diameter, lobar location, depth from the hepatic capsule, and appearance of lesions) in a series of nine patients with pathologically proven solitary necrotic nodules of the liver and the natural evolution at follow-up in four of the nine patients. CONCLUSION: Solitary necrotic nodules are usually small, solitary lesions, mainly located under the liver capsule of the right lobe. They are hypoechoic on sonography, hypoattenuating on CT, have low signal intensity on both T1- and T2-weighted MRI with lack of enhancement after IV contrast administration, and at follow-up have a tendency to show calcification and involution toward reduction in size.


Assuntos
Neoplasias Hepáticas/diagnóstico , Fígado/patologia , Adulto , Idoso , Meios de Contraste , Dextranos , Feminino , Óxido Ferroso-Férrico , Seguimentos , Gadolínio DTPA , Humanos , Interpretação de Imagem Assistida por Computador , Iohexol/análogos & derivados , Ferro , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética , Nanopartículas de Magnetita , Masculino , Pessoa de Meia-Idade , Necrose/patologia , Óxidos , Estudos Retrospectivos , Tomografia Computadorizada Espiral , Ultrassonografia Doppler
9.
J Heart Lung Transplant ; 27(3): 310-6, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18342754

RESUMO

BACKGROUND: Post-transplant follow-up of heart transplant patients consists of repeated coronary angiography, which is associated with high costs, discomfort and risk. We sought to determine whether multislice computed tomography (MSCT) permits the exclusion or progression of coronary artery disease in heart transplant patients. METHODS: MSCT scanning (Philips CT MX 8000 IDT) and invasive coronary angiography were performed on 66 consecutive heart transplant patients. One hundred milliliters of non-ionic iodinated contrast medium was applied for CT angiography. For MSCT analysis, coronary arteries and side branches with a diameter > or =1.5 mm were assessed for the presence of luminal narrowing of >70%. MSCT results were compared with those of quantitative coronary angiography analysis. RESULTS: Ten patients (17%) had one significant stenosis, whereas 3 patients (5%) had 2-vessel disease and none had 3-vessel disease. MSCT was performed successfully on 60 patients enrolled in our analysis. Forty-two of 44 patients (95%) who were estimated to be fully evaluable for MSCT were correctly classified. On per-segment-based analysis, sensitivity, specificity and positive and negative predictive values were 59%, 94%, 91% and 99.43%, respectively. After exclusion of unevaluable segments, sensitivity and specificity increased to 71% and 99.86%, respectively. On per-patient-based analysis, sensitivity, specificity and positive and negative predictive values were 88%, 97%, 88% and 97%, respectively, in evaluable transplant recipients. CONCLUSIONS: MSCT with its high specificity and high negative predictive value allows the exclusion of significant coronary artery vasculopathy in evaluable patients. From the clinical point of view, this might spare additional invasive coronary angiography in heart transplant patients.


Assuntos
Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Transplante de Coração , Tomografia Computadorizada Espiral/métodos , Adulto , Idoso , Angiografia Coronária , Estenose Coronária/patologia , Vasos Coronários/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/patologia , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Ultrassonografia
10.
Cardiovasc Intervent Radiol ; 31(3): 468-76, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18228095

RESUMO

Transarterial chemoembolization (TACE) involves the emulsification of a chemotherapeutic agent in a viscous drug carrier, delivered intra-arterially to liver tumor for maximum effect. TACE reduces arterial inflow, diminishes washout of the chemotherapeutic agent, and decreases systemic exposure. Despite evidence of some clinical success with TACE, a new type of microspheres with drug-eluting capabilities may offer a precisely controlled and sustainable release of the chemotherapeutic agent into the tumor bed. In animal trials tumor necrosis (approaching 100%) was greatest at 7 days, with significantly lower plasma concentrations of doxorubicin than in control animals treated with doxorubicin intra-arterially. Clinically, drug-eluting microspheres loaded with doxorubicin, either at 75 mg/m(2) or at a fixed dose of 150 mg, were used recently and no severe disorders of the hepatic function were observed postprocedure, while a substantial reduction of the fetoprotein levels occurred. An interim analysis of the first 15 patients from the Hong Kong group at 3 months showed an objective response rate of 61.54% and 53.84% according to EASL criteria and RECIST criteria, respectively, and a survival rate of 93.3%. In this paper we present how to use microspheres loaded with doxorubicin and review their clinical value and preliminary performance for treatment of unresectable liver cancer.


Assuntos
Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Doxorrubicina/administração & dosagem , Portadores de Fármacos/administração & dosagem , Neoplasias Hepáticas/terapia , Microesferas , Animais , Carcinoma Hepatocelular/mortalidade , Carcinoma Hepatocelular/patologia , Modelos Animais de Doenças , Relação Dose-Resposta a Droga , Esquema de Medicação , Sistemas de Liberação de Medicamentos , Feminino , Seguimentos , Humanos , Infusões Intra-Arteriais , Neoplasias Hepáticas/mortalidade , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas Experimentais , Masculino , Estadiamento de Neoplasias , Seleção de Pacientes , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Análise de Sobrevida , Resultado do Tratamento
11.
Magn Reson Med ; 59(1): 96-101, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18098282

RESUMO

The T(1) values of lung parenchyma of 25 patients with fibrosis and emphysema were measured in the entire lung, and the effect of inspiration and expiration was investigated. T(1) map acquisition was based on a snapshot-fast low-angle shot (FLASH) sequence. Lung function and blood gas tests were measured. The study documents reverse respiratory phase dependence of T(1) measurements of the entire lung parenchyma in patients with emphysema and fibrosis. Furthermore, expiratory measurements showed higher and reverse differences between patient groups compared to inspiratory measurements. For the emphysema group, the average T(1) value in inspiration was 1033 +/- 74 ms. The average of the mean T(1) values in expiration was 982 +/- 56 ms. For the patients with fibrosis, the average T(1) value in inspiration was 996 +/- 103 ms. Compared to that, the average T(1) value in expiration was 1282 +/- 170 ms. Linear regression of T(1) vs. lung function parameters showed the highest regression coefficients for total lung capacity (TLC) and residual volume (RV) in expiration, the values were inversely proportionally dependent on the pooled expiratory T(1) values. These findings underline the strong but nonuniform influence of the inspirational status during T(1) measurements of the lung. T(1) maps in both emphysema and fibrosis should preferably be acquired at expiration if reliable data are to be obtained.


Assuntos
Imageamento por Ressonância Magnética/métodos , Enfisema Pulmonar/fisiopatologia , Fibrose Pulmonar/fisiopatologia , Adulto , Idoso , Gasometria , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Testes de Função Respiratória , Mecânica Respiratória/fisiologia , Estatísticas não Paramétricas
12.
Cardiovasc Intervent Radiol ; 31(3): 563-8, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-17955287

RESUMO

This paper reports our experience with endovascular techniques for the retrieval of lost or misplaced intravascular objects. Over 12 years, 78 patients were referred for interventional retrieval of intravascular foreign objects. In this retrospective study, radiological procedure records and patients' medical records were reviewed to determine the exact removal procedure in every case, to report success rates, and to identify significant procedure-related complications. Written, informed consent was obtained from all patients prior to the intervention; this retrospective analysis was performed according to the guidelines of the Institutional Review Board. Thirty-six of seventy-eight foreign objects (46%) were located in the venous system, 27 of 78 (35%) in the right heart, and 15 of 78 (19%) in the pulmonary arteries. For foreign object removal, in 71 of 78 (91%) cases a snare loop was used, in 6 of 78 (8%) cases a sidewinder catheter combined with a snare loop was used, and in 1 case (1%) a sidewinder catheter alone was used for foreign object removal. In 68 of 78 (87%) cases, primary success was achieved. In 3 of 78 cases (4%), foreign objects were successfully mobilized to the femoral vessels and surgically removed. In 7 of 78 cases (9%), complete removal of the foreign object was not possible. In 5 of 78 cases (6%), minor complications occurred during the removal procedure. In conclusion, endovascular retrieval of lost or misplaced intravascular objects is highly effective, with relatively few minor complications. On the basis of our findings, these techniques should be considered as the therapy of choice.


Assuntos
Angioplastia/métodos , Vasos Sanguíneos , Cateterismo/efeitos adversos , Corpos Estranhos/terapia , Adolescente , Adulto , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Cateterismo/instrumentação , Cateteres de Demora/efeitos adversos , Criança , Estudos de Coortes , Feminino , Seguimentos , Corpos Estranhos/diagnóstico por imagem , Corpos Estranhos/epidemiologia , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/terapia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista/métodos , Estudos Retrospectivos , Medição de Risco , Distribuição por Sexo , Fatores de Tempo
13.
Eur J Radiol ; 68(3): 465-70, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17913428

RESUMO

PURPOSE: To compare the performance of 64-slice with 16-slice CT scanners for the in vitro evaluation of coronary artery stents. METHODS AND MATERIALS: Twelve different coronary artery stents were placed in the drillings of a combined heart and chest phantom, which was scanned with a 16- and 64-slice CT scanner. Coronal reformations were evaluated for artificial lumen narrowing, intraluminal attenuation values, and false widening of the outer stent diameter as an indicator of artifacts outside the stent. RESULTS: Mean artificial lumen narrowing was not significantly different between the 16- and 64-slice CT scanner (44% versus 39%; p=0.408). The differences between the Hounsfield Units (HU) measurements inside and outside the stents were significantly lower (p=0.001) with 64- compared to 16-slice CT. The standard deviation of the HU measurements inside the stents was significantly (p=0.002) lower with 64- than with 16-slice CT. Artifacts outside the stents were not significantly different between the scanners (p=0.866). CONCLUSION: Visualization of the in-stent lumen is improved with 64-slice CT when compared with 16-slice CT as quantified by significantly lesser intraluminal image noise and less artificial rise in intraluminal HU measurement, which is the most important parameter for the evaluation of stent patency in vivo.


Assuntos
Prótese Vascular , Angiografia Coronária/instrumentação , Angiografia Coronária/métodos , Vasos Coronários/cirurgia , Stents , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
AJR Am J Roentgenol ; 189(5): 1215-22, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17954664

RESUMO

OBJECTIVE: The purpose of this study was to assess the reliability of treatment decisions based on MDCT angiographic findings of stage IIb peripheral arterial occlusive disease (PAOD). MATERIALS AND METHODS: Fifty-eight patients with stage IIb PAOD underwent CT angiography of the abdominal aorta and runoff vessels for further treatment planning. Treatment reports, discharge summaries, and follow-up examinations were reviewed to determine the number of treatments correctly planned on the basis of CT angiographic findings. RESULTS: On the basis of CT angiographic findings, endovascular treatment was indicated for 18 patients, surgical revascularization for nine patients, and a combined endovascular and surgical approach for two patients. Conservative treatment was indicated for 29 patients. On the basis of successful revascularization, the correctness of the treatment decision was confirmed in all but one patient (n = 28). The treatment plan was modified for one patient referred for surgical revascularization. In that patient, stenosis of the common femoral artery had been overlooked on CT angiography. Patients for whom conservative management was indicated on the basis of CT angiographic findings (n = 29) had a mean follow-up period of 501 days without needing revascularization treatment. This result was defined as indirect confirmation of the accuracy of the decision made with CT angiography. CONCLUSION: The findings on MDCT angiography led to correct treatment recommendations for patients with claudication. Thus, CT angiography should be used in the management of PAOD.


Assuntos
Angiografia/métodos , Claudicação Intermitente/diagnóstico por imagem , Claudicação Intermitente/terapia , Doenças Vasculares Periféricas/diagnóstico por imagem , Doenças Vasculares Periféricas/terapia , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/instrumentação , Resultado do Tratamento
15.
J Endovasc Ther ; 14(3): 387-94, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17723005

RESUMO

PURPOSE: To evaluate the role of 4 different reformation techniques in comparison with axial images from multidetector computed tomographic angiography (MDCTA) in the follow-up of renal artery stents. METHODS: Data on 40 patients (20 men; mean age 65 years) who underwent MDCTA as part of their routine follow-up after successful primary stenting of a main renal artery were retrospectively analyzed. Multiplanar reformation (MPR), curved planar reformation (CPR), volume rendering threshold (VRT), and virtual angioscopy (VA) were reviewed by 2 independent observers who were blinded to the results of the axial source images, which served as the gold standard. The stenosis degree was scored as I = 0%, II <50%, III = 51%-75%, IV = 76%-99%, or V = occlusion; a stenosis >50% was considered hemodynamically significant. RESULTS: Five hemodynamically significant stenoses were identified on axial images. The correlation with axial images was perfect for both observers using MPR and CPR (kappa = 1 for each observer); corresponding results were kappa = 0.69 and kappa = 0.64 for VRT and kappa = 0.88 and kappa = 0.83 for VA, respectively. The interobserver correlations were excellent for all reformation techniques (kappa = 0.95 to 1). CONCLUSION: Compared to axial images, MPR and CPR correlated perfectly with axial images; VA performed surprisingly well, while VRT was affected by artifacts and consequently showed inferior results.


Assuntos
Angioplastia com Balão , Interpretação de Imagem Radiográfica Assistida por Computador , Obstrução da Artéria Renal/diagnóstico por imagem , Artéria Renal/diagnóstico por imagem , Stents , Tomografia Computadorizada por Raios X/instrumentação , Interface Usuário-Computador , Idoso , Angiografia/instrumentação , Artefatos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Obstrução da Artéria Renal/terapia , Reprodutibilidade dos Testes , Projetos de Pesquisa , Estudos Retrospectivos , Índice de Gravidade de Doença , Resultado do Tratamento
16.
Int J Biomed Imaging ; 2007: 23624, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17710253

RESUMO

PURPOSE: beyond the pure morphological visual representation, MR imaging offers the possibility to quantify parameters in the healthy, as well as, in pathologic lung parenchyma. Gas exchange is the primary function of the lung and the transport of oxygen plays a key role in pulmonary physiology and pathophysiology. The purpose of this review is to present a short overview of the relaxation mechanisms of the lung and the current technical concepts of T1 mapping and methods of oxygen enhanced MR imaging. MATERIAL AND METHODS: molecular oxygen has weak paramagnetic properties so that an increase in oxygen concentration results in shortening of the T1 relaxation time and thus to an increase of the signal intensity in T1 weighted images. A possible way to gain deeper insights into the relaxation mechanisms of the lung is the calculation of parameter Maps. T1 Maps based on a snapshot FLASH sequence obtained during the inhalation of various oxygen concentrations provide data for the creation of the so-called oxygen transfer function (OTF), assigning a measurement for local oxygen transfer. T1 weighted single shot TSE sequences also permit expression of the signal changing effects associated with the inhalation of pure oxygen. RESULTS: the average of the mean T1 values over the entire lung in inspiration amounts to 1199 +/- 117 milliseconds, the average of the mean T1 values in expiration was 1333 +/- 167 milliseconds. T1 Maps of patients with emphysema and lung fibrosis show fundamentally different behavior patterns. Oxygen enhanced MRT is able to demonstrate reduced diffusion capacity and diminished oxygen transport in patients with emphysema and cystic fibrosis. DISCUSSION: results published in literature indicate that T1 mapping and oxygen enhanced MR imaging are promising new methods in functional imaging of the lung and when evaluated in conjunction with the pure morphological images can provide additional valuable information.

17.
Ann Thorac Surg ; 83(3): 1059-66, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17307460

RESUMO

BACKGROUND: The aim of this study was to determine the technical success after endovascular treatment of acute type B aortic dissections and to evaluate true and false lumen diameter changes at long-term follow-up. METHODS: Twenty-eight patients with acute type B-dissection who were treated by stent graft repair presented with rupture (n = 1), contained rupture (n = 2), compromised branch vessels (n = 14), pleural effusion (n = 11), rapid aortic diameter progression (n = 5), persistent pain (n = 3), refractory hypertension (n = 10), and an aortic diameter of more than 4 cm (n = 4). Taking into account the perfusion status of the false lumen, diameter changes were monitored in the thoracic aorta at the level of the stented segment (L1), distal to the stent graft (L2), and at the level of the celiac trunk (L3). RESULTS: Severe complications in 9 patients (32%) resulted in 3 deaths for a 30-day mortality rate of 10.7%. Primary sealing of the entry tear was achieved in 86%. At all levels, the true lumen diameter increased significantly after stent graft placement. At the 1-year follow-up, the false lumen in L1 was thrombosed in 90% and the mean difference of diameter reduction was highly significant. In L2, complete false lumen thrombosis occurred in 60% with a significant diameter decrease. In L3, the false lumen thrombosed in only 22%, and the mean difference of false lumen diameter increase reached significance at the 2-year follow-up. CONCLUSIONS: Ninety percent of patients were treated successfully with thrombosis of the false lumen in the stented segment. False lumen perfusion distal to the stent graft resulted in diameter increase in several patients leaving these segments an area of concern.


Assuntos
Aneurisma Aórtico/terapia , Dissecção Aórtica/terapia , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/complicações , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/mortalidade , Aneurisma Roto/terapia , Aorta Abdominal/diagnóstico por imagem , Aorta Torácica/diagnóstico por imagem , Aneurisma Aórtico/complicações , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/mortalidade , Aortografia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Stents/efeitos adversos , Trombose/diagnóstico por imagem , Trombose/etiologia , Tomografia Computadorizada por Raios X
18.
Eur Radiol ; 17(5): 1242-55, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17149625

RESUMO

A wide variety of artifacts can be seen in clinical MR imaging. This review describes the most important and most prevalent of them, including magnetic susceptibility artifacts and motion artifacts, aliasing, chemical-shift, zipper, zebra, central point, and truncation artifacts. Although the elimination of some artifacts may require a service engineer, the radiologist and MR technologist have the responsibility to recognize MR imaging problems. This review shows the typical MR appearance of the described artifacts, explains their physical basis, and shows the way to solve them in daily practice.


Assuntos
Artefatos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Meios de Contraste , Diagnóstico Diferencial , Erros de Diagnóstico , Humanos
19.
Eur J Radiol ; 62(2): 267-72, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17188829

RESUMO

OBJECTIVE: Dry laser printers have replaced wet laser printers to produce hard copies of high-resolution digital images, primarily because of environmental concerns. However, no scientific research data have been published that compare the image quality of dry and wet laser printers in full-field digital mammography (FFDM). This study questions the image quality of these printers. MATERIALS AND METHODS: Objective image quality parameters of both printers were evaluated using a standardized printer test image, i.e., optical density and detectability of specific image elements (lines, curves, and shapes). Furthermore, mammograms of 129 patients with different breast tissue composition patterns were imaged with both printers. A total of 1806 subjective image quality parameters (brightness, contrast, and detail detection of anatomic structures), the detectability of breast lesions, as well as diagnostic performance according to the BI-RADS classification were evaluated. In addition, the presence of film artifacts was investigated. RESULTS: Optical density values were equal for the dry and the wet laser printer. Detection of specific image elements on the printer test image was not different. Ratings of subjective image quality parameters were equal, as were the detectability of breast lesions and the diagnostic performance. Dry laser printer images showed more artifacts (164 versus 27). However, these artifacts did not influence image quality. CONCLUSION: Based on the evidence of objective and subjective parameters, a dry laser printer equals the image quality of a wet laser printer in FFDM. Therefore, not only for reasons of environmental preference, the replacement of wet laser printers by dry laser printers in FFDM is justified.


Assuntos
Lasers , Mamografia , Impressão , Intensificação de Imagem Radiográfica , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/epidemiologia , Análise de Falha de Equipamento , Feminino , Humanos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Interpretação de Imagem Radiográfica Assistida por Computador , Sensibilidade e Especificidade
20.
Top Magn Reson Imaging ; 18(6): 445-55, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18303402

RESUMO

The histological structure of the liver is complex, consisting of hepatocytes, biliary epithelium, and mesenchymal cells. From this large variety of cells, a broad spectrum of benign and malignant liver lesions in originate. An accurate diagnosis of these lesions is mandatory for choosing an appropriate therapeutic approach. With the recent developments in hardware and software, magnetic resonance imaging (MRI) has emerged as the method of choice in the diagnostic workup of focal liver lesions, in particular in the pretherapeutic stage. The introduction of high-field MRI at 3.0 T in the routine workup and the selective use of liver-specific contrast agents, including hepatobiliary and reticuloendothelial agents, have also strengthened the role of MRI in liver imaging. In this overview article, we will review the recent developments in 3.0-T MRI and MRI contrast agents in the diagnostic workup of the most common malignant liver tumors.


Assuntos
Neoplasias Hepáticas/diagnóstico , Imageamento por Ressonância Magnética/métodos , Meios de Contraste , Humanos , Neoplasias Hepáticas/epidemiologia , Neoplasias Hepáticas/patologia , Metástase Neoplásica/diagnóstico , Estadiamento de Neoplasias
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...