Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
PLoS One ; 17(7): e0271183, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35857753

RESUMO

PURPOSE: Rising complexity of patients and the consideration of heterogeneous information from various IT systems challenge the decision-making process of urological oncologists. Siemens AI Pathway Companion is a decision support tool that provides physicians with comprehensive patient information from various systems. In the present study, we examined the impact of providing organized patient information in comprehensive dashboards on information quality, effectiveness, and satisfaction of physicians in the clinical decision-making process. METHODS: Ten urologists in our department performed the entire diagnostic workup to treatment decision for 10 patients in the prostate cancer screening setting. Expenditure of time, information quality, and user satisfaction during the decision-making process with AI Pathway Companion were recorded and compared to the current workflow. RESULTS: A significant reduction in the physician's expenditure of time for the decision-making process by -59.9% (p < 0,001) was found using the software. System usage showed a high positive effect on evaluated information quality parameters completeness (Cohen's d of 2.36), format (6.15), understandability (2.64), as well as user satisfaction (4.94). CONCLUSION: The software demonstrated that comprehensive organization of information improves physician's effectiveness and satisfaction in the clinical decision-making process. Further development is needed to map more complex patient pathways, such as the follow-up treatment of prostate cancer.


Assuntos
Detecção Precoce de Câncer , Neoplasias da Próstata , Inteligência Artificial , Tomada de Decisão Clínica , Tomada de Decisões , Humanos , Masculino , Antígeno Prostático Específico , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/terapia
2.
Korean J Radiol ; 20(2): 265-274, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30672166

RESUMO

OBJECTIVE: To compare the image quality of three-dimensional time-of-flight (TOF) magnetic resonance angiography (MRA) with sparse undersampling and iterative reconstruction (sparse TOF) with that of conventional TOF MRA. MATERIALS AND METHODS: This study included 56 patients who had undergone sparse TOF MRA for intracranial artery evaluation on a 3T MR scanner. Conventional TOF MRA scans were also acquired from 29 patients with matched acquisition times and another 27 patients with matched scanning parameters. The image quality was scored using a five-point scale based on the delineation of arterial vessel segments, artifacts, overall vessel visualization, and overall image quality by two radiologists independently, and the data were analyzed using the non-parametric Wilcoxon signed-rank test. Contrast ratios (CRs) of vessels were compared using the paired t test. Interobserver agreement was calculated using the kappa test. RESULTS: Compared with conventional TOF at the same spatial resolution, sparse TOF with an acceleration factor of 3.5 could reduce acquisition time by 40% and showed comparable image quality. In addition, when compared with conventional TOF with the same acquisition time, sparse TOF with an acceleration factor of 5 could also achieve higher spatial resolution, better delineation of vessel segments, fewer artifacts, higher image quality, and a higher CR (p < 0.05). Good-to-excellent interobserver agreement (κ: 0.65-1.00) was obtained between the two radiologists. CONCLUSION: Compared with conventional TOF, sparse TOF can achieve equivalent image quality in a reduced duration. Furthermore, using the same acquisition time, sparse TOF could improve the delineation of vessels and decrease image artifacts.


Assuntos
Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Artérias Cerebrais/diagnóstico por imagem , Tontura/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Adulto , Idoso , Artefatos , Tontura/diagnóstico , Feminino , Humanos , Aumento da Imagem , Masculino , Pessoa de Meia-Idade
3.
Sci Rep ; 8(1): 9111, 2018 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-29904131

RESUMO

The purpose of this study is to evaluate the hemodynamic characteristics of the true lumen (TL) and the false lumen (FL) in 16 patients with aortic dissection (AD) using 4D flow magnetic resonance imaging (MRI) and thoracic and abdominal computed tomography (CT) angiography. The quantitative parameters that were measured in the TL and FL included velocity and flow. The mean area and regurgitant fraction of the TL were significantly lesser at all four levels (p < 0.05); the average through-plane velocity, peak velocity magnitude, average net flow, peak flow, and net forward volume in the TL were considerably higher (p < 0.05). The intimal entry's size was negatively correlated with the blood flow velocity and flow rate in the TL (p < 0.05) and positively correlated with the average through-plane velocity, average net flow, and peak flow in the FL (p < 0.05); the blood flow indices in the TL were enhanced with an increase in the intimal entry numbers (p < 0.05) and the peak flow in the FL was lowered (p = 0.025); if FL thrombosis existed, the average through-plane velocity and peak velocity magnitude in the TL were substantially higher (p < 0.05). 4D flow MRI facilitates qualitative and quantitative analysis of the alterations in the abdominal aortic blood flow patterns.


Assuntos
Aorta Abdominal , Dissecção Aórtica , Angiografia por Ressonância Magnética , Tomografia Computadorizada por Raios X , Adulto , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/fisiopatologia , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/fisiopatologia , Velocidade do Fluxo Sanguíneo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
4.
PLoS One ; 13(1): e0189493, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29351284

RESUMO

Compressed sensing (CS) reconstructions of under-sampled measurements generate missing data based on assumptions of image sparsity. Non-contrast time-of-flight MR angiography (TOF-MRA) is a good candidate for CS based acceleration, as MRA images feature bright trees of sparse vessels over a well-suppressed anatomical background signal. A short scan time derived from CS is beneficial for patients of moyamoya disease (MMD) because of the frequency of MR scans. The purpose of this study was to investigate the reliability of TOF-MRA with CS in the evaluation of MMD. Twenty-two patients were examined using TOF-MRA with CS (CS-TOF) and parallel imaging (PI-TOF). The acceleration factors were 3 (CS3) and 5 (CS5) for CS-TOF, and 3 (PI3) for PI-TOF. Two neuroradiologists evaluated the MMD grading according to stenosis/occlusion scores using the modified Houkin's system, and the visibility of moyamoya vessels (MMVs) using a 3-point scale. Concordance was calculated with Cohen's κ. The numbers of MMVs in the basal ganglia were compared using Bland-Altman analysis and Wilcoxon's signed-rank tests. MRA scan times were 4:07, 3:53, and 2:42 for PI3, CS3, and CS5, respectively. CS-reconstruction completed within 10 minutes. MMD grading and MMV visibility scales showed excellent correlation (κ > .966). Although the number of MMVs was significantly higher in CS3 than in PI3 (p < .0001) and CS5 (p < .0001), Bland-Altman analysis showed a good agreement between PI3, CS3, and CS5. Compressed sensing can accelerate TOF-MRA with improved visualization of small collaterals in equivalent time (CS3) or equivalent results in a shorter scan time (CS5).


Assuntos
Angiografia por Ressonância Magnética/métodos , Doença de Moyamoya/diagnóstico , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
5.
Magn Reson Med ; 77(2): 833-840, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-26888549

RESUMO

PURPOSE: To evaluate the clinical benefit of using a new iterative reconstruction technique fully integrated on a standard clinical scanner and reconstruction system using a TWIST acquisition for high-resolution dynamic three-dimensional contrast-enhanced MR angiography (CE-MRA). METHODS: Low-dose, high-resolution TWIST datasets of 11 patients were reconstructed using both standard GRAPPA-based reconstruction for reference and iterative reconstruction, which reduces the temporal footprint of reconstructed images. Image quality of both techniques was assessed by two experienced readers, as well as quantitatively evaluated using a time-signal curve analysis. RESULTS: Image quality scores consistently and significantly improved by using iterative reconstruction compared with the standard approach. Most notably, the delineation of small to mid-size vasculature improved from a mean Likert score between "nondiagnostic" and "poor" for standard to between "good" and "excellent" for iterative reconstruction. The full width at half maximum of the contrast agent bolus computed from the time-signal curve was also reduced by iterative reconstruction, allowing for more precise bolus timing. CONCLUSION: Iterative reconstruction can substantially improve high-resolution dynamic CE-MRA image quality, most notably in small to mid-size vasculature. Dynamic CE-MRA with iterative reconstruction could become an alternative to conventional static 3D CE-MRA, thus simplifying the clinical workflow. Magn Reson Med 77:833-840, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Tórax , Adulto , Algoritmos , Aneurisma Aórtico/diagnóstico por imagem , Coartação Aórtica/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tórax/irrigação sanguínea , Tórax/diagnóstico por imagem
6.
J Cardiovasc Magn Reson ; 18(1): 63, 2016 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-27688028

RESUMO

BACKGROUND: The hypertensive deoxy-corticosterone acetate (DOCA)-salt-treated pig (hereafter, DOCA pig) was recently introduced as large animal model for early-stage heart failure with preserved ejection fraction (HFpEF). The aim of the present study was to evaluate cardiovascular magnetic resonance (CMR) of DOCA pigs and weight-matched control pigs to characterize ventricular, atrial and myocardial structure and function of this phenotype model. METHODS: Five anesthetized DOCA and seven control pigs underwent 3 T CMR at rest and during dobutamine stress. Left ventricular/atrial (LV/LA) function and myocardial mass (LVMM), strains and torsion were evaluated from (tagged) cine imaging. 4D phase-contrast measurements were used to assess blood flow and peak velocities, including transmitral early-diastolic (E) and myocardial tissue (E') velocities and coronary sinus blood flow. Myocardial perfusion reserve was estimated from stress-to-rest time-averaged coronary sinus flow. Global native myocardial T1 times were derived from prototype modified Look-Locker inversion-recovery (MOLLI) short-axis T1 maps. After in-vivo measurements, transmural biopsies were collected for stereological evaluation including the volume fractions of interstitium (VV(int/LV)) and collagen (VV(coll/LV)). Rest, stress, and stress-to-rest differences of cardiac and myocardial parameters in DOCA and control animals were compared by t-test. RESULTS: In DOCA pigs LVMM (p < 0.001) and LV wall-thickness (end-systole/end-diastole, p = 0.003/p = 0.007) were elevated. During stress, increase of LV ejection-fraction and decrease of end-systolic volume accounted for normal contractility reserves in DOCA and control pigs. Rest-to-stress differences of cardiac index (p = 0.040) and end-diastolic volume (p = 0.042) were documented. Maximal (p = 0.042) and minimal (p = 0.012) LA volumes in DOCA pigs were elevated at rest; total LA ejection-fraction decreased during stress (p = 0.006). E' was lower in DOCA pigs, corresponding to higher E/E' at rest (p = 0.013) and stress (p = 0.026). Myocardial perfusion reserve was reduced in DOCA pigs (p = 0.031). T1-times and VV(int/LV) did not differ between groups, whereas VV(coll/LV) levels were higher in DOCA pigs (p = 0.044). CONCLUSIONS: LA enlargement, E' and E/E' were the markers that showed the most pronounced differences between DOCA and control pigs at rest. Inadequate increase of myocardial perfusion reserve during stress might represent a metrics for early-stage HFpEF. Myocardial T1 mapping could not detect elevated levels of myocardial collagen in this model. TRIAL REGISTRATION: The study was approved by the local Bioethics Committee of Vienna, Austria (BMWF-66.010/0091-II/3b/2013).

7.
BMC Med Imaging ; 16(1): 45, 2016 08 08.
Artigo em Inglês | MEDLINE | ID: mdl-27501792

RESUMO

BACKGROUND: In patients with pulmonary hypertension (PH), duration of vortical blood flow along the main pulmonary artery enables estimation of the mean pulmonary arterial pressure (mPAP) non-invasively. It remains to date not known, if this method is applicable in patients with pulmonary arterial hypertension (PAH) and abnormal aortic-to-pulmonary shunting. CASE PRESENTATION: The present case analyzes the effect of a patent ductus arteriosus (PDA) on pulmonary artery flow patterns in PAH (mPAP from right heart catheterization, 75 mmHg). PH-associated vortical blood flow, which is typically observed rotating in a clockwise direction when viewed in right ventricular outflow tract orientation, was found nested in PDA left-to-right shunting. Even though rotating counter-clockwise, duration of vortical flow translated into correct non-invasive mPAP estimate. CONCLUSIONS: This case indicates that PH-associated vortex rotation is not restricted to clockwise direction, and that vortex-based estimation of elevated mPAP might also be feasible in patients with PAH and PDA.


Assuntos
Permeabilidade do Canal Arterial/fisiopatologia , Hipertensão Pulmonar/fisiopatologia , Imagem Cinética por Ressonância Magnética/métodos , Artéria Pulmonar/fisiopatologia , Velocidade do Fluxo Sanguíneo , Permeabilidade do Canal Arterial/diagnóstico por imagem , Hemodinâmica , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Masculino , Adulto Jovem
8.
J Cardiovasc Magn Reson ; 18(1): 42, 2016 07 20.
Artigo em Inglês | MEDLINE | ID: mdl-27435406

RESUMO

BACKGROUND: Oxygenation-sensitive (OS) Cardiovascular Magnetic Resonance (CMR) is a promising utility in the diagnosis of heart disease. Contrast in OS-CMR images is generated through deoxyhemoglobin in the tissue, which is negatively correlated with the signal intensity (SI). Thus, changing hematocrit levels may be a confounder in the interpretation of OS-CMR results. We hypothesized that hemodilution confounds the observed signal intensity in OS-CMR images. METHODS: Venous and arterial blood from five pigs was diluted with lactated Ringer solution in 10 % increments to 50 %. The changes in signal intensity (SI) were compared to changes in blood gases and hemoglobin concentration. We performed an OS-CMR scan in 21 healthy volunteers using vasoactive breathing stimuli at baseline, which was then repeated after rapid infusion of 1 L of lactated Ringer's solution within 5-8 min. Changes of SI were measured and compared between the hydration states. RESULTS: The % change in SI from baseline for arterial (r = -0.67, p < 0.0001) and venous blood (r = -0.55, p = 0.002) were negatively correlated with the changes in hemoglobin (Hb). SI changes in venous blood were also associated with SO2 (r = 0.68, p < 0.0001) and deoxyHb concentration (-0.65, p < 0.0001). In healthy volunteers, rapid infusion resulted in a significant drop in the hemoglobin concentration (142.5 ± 15.2 g/L vs. 128.8 ± 15.2 g/L; p < 0.0001). Baseline myocardial SI increased by 3.0 ± 5.7 % (p = 0.026) following rapid infusion, and in males there was a strong association between the change in hemoglobin concentration and % changes in SI (r = 0.82, p = 0.002). After hyperhydration, the SI response after hyperventilation was attenuated (HV, p = 0.037), as was the maximum SI increase during apnea (p = 0.012). The extent of SI attenuation was correlated with the reduction in hemoglobin concentration at the end of apnea (r = 0.55, p = 0.012) for all subjects and at maximal SI (r = 0.63, p = 0.037) and the end of breath-hold (r = 0.68, p = 0.016) for males only. CONCLUSION: In dynamic studies using oxygenation-sensitive CMR, the hematocrit level affects baseline signal intensity and the observed signal intensity response. Thus, the hydration status of the patient may be a confounder for OS-CMR image analysis.


Assuntos
Coração/diagnóstico por imagem , Hematócrito , Hemodiluição/métodos , Hemoglobinas/metabolismo , Soluções Isotônicas/administração & dosagem , Imagem Cinética por Ressonância Magnética , Miocárdio/metabolismo , Oxigênio/sangue , Adolescente , Adulto , Animais , Biomarcadores/metabolismo , Feminino , Voluntários Saudáveis , Frequência Cardíaca , Humanos , Interpretação de Imagem Assistida por Computador , Infusões Intravenosas , Masculino , Reprodutibilidade dos Testes , Mecânica Respiratória , Lactato de Ringer , Sus scrofa , Equilíbrio Hidroeletrolítico , Adulto Jovem
9.
Eur Radiol ; 26(10): 3588-97, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26747263

RESUMO

OBJECTIVES: To validate 4D flow MRI in a flow phantom using a flowmeter and computational fluid dynamics (CFD) as reference. METHODS: Validation of 4D flow MRI was performed using flow phantoms with 75 % and 90 % stenosis. The effect of spatial resolution on flow rate, peak velocity and flow patterns was investigated in coronal and axial scans. The accuracy of flow rate with 4D flow MRI was evaluated using a flowmeter as reference, and the peak velocity and flow patterns obtained were compared with CFD analysis results. RESULTS: 4D flow MRI accurately measured the flow rate in proximal and distal regions of the stenosis (percent error ≤3.6 % in axial scanning with 1.6-mm resolution). The peak velocity of 4D flow MRI was underestimated by more than 22.8 %, especially from the second half of the stenosis. With 1-mm isotropic resolution, the maximum thickness of the recirculating flow region was estimated within a 1-mm difference, but the turbulent velocity fluctuations mostly disappeared in the post-stenotic region. CONCLUSION: 4D flow MRI accurately measures the flow rates in the proximal and distal regions of a stenosis in axial scan but has limitations in its estimation of peak velocity and turbulent characteristics. KEY POINTS: • 4D flow MRI accurately measures the flow rate in axial scan. • The peak velocity was underestimated by 4D flow MRI. •4D flow MRI demonstrates the principal pattern of post-stenotic flow.


Assuntos
Arteriopatias Oclusivas/diagnóstico por imagem , Hidrodinâmica , Angiografia por Ressonância Magnética/métodos , Modelos Cardiovasculares , Arteriopatias Oclusivas/fisiopatologia , Velocidade do Fluxo Sanguíneo/fisiologia , Simulação por Computador , Constrição Patológica , Fluxômetros , Humanos , Imageamento Tridimensional/métodos , Imagens de Fantasmas
10.
J Magn Reson Imaging ; 43(6): 1313-9, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26584006

RESUMO

PURPOSE: To determine whether neglecting the flow unsteadiness in simplified Bernoulli's equation significantly affects the pulmonary transvalvular pressure drop estimation. MATERIALS AND METHODS: 3.0T magnetic resonance imaging (MRI) 4D velocity mapping was performed on four healthy volunteers, seven patients with repaired tetralogy of Fallot, and thirteen patients with transposition of the great arteries repaired by arterial switch. Pulmonary transvalvular pressure drop was estimated based on two methods: General Bernoulli's Equation (GBE), ie, the most complete form; and Simplified Bernoulli's Equation (SBE), known as 4V(2) . More than 2300 individual pressure drop measurements were used to compare the simplified and the general Bernoulli's methods. A linear mixed-effects model was employed for statistical analyses, fully accounting for clustering of observations among the methods and systolic phases. RESULTS: The simplified Bernoulli's method systematically underestimated the pressure drop compared to general Bernoulli's method during the entire systolic phase (P < 0.05), including the peak systole, where on average ΔpSBE/ΔpGBE=78%. CONCLUSION: The simplified Bernoulli method underestimated the pressure drop during all systolic phases in all the studied subjects. Therefore, it is necessary to take into account the flow unsteadiness for more accurate estimation of the pressure drop. J. Magn. Reson. Imaging 2016;43:1313-1319.


Assuntos
Determinação da Pressão Arterial/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Modelos Cardiovasculares , Estenose da Valva Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/fisiopatologia , Valva Pulmonar/fisiopatologia , Adolescente , Adulto , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Criança , Simulação por Computador , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Circulação Pulmonar , Valva Pulmonar/diagnóstico por imagem , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
11.
Invest Radiol ; 51(6): 372-8, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26561046

RESUMO

OBJECTIVES: The aim of this study was to evaluate the clinical feasibility of accelerated time-of-flight (TOF) magnetic resonance angiography with sparse undersampling and iterative reconstruction (sparse TOF). MATERIALS AND METHODS: The local institutional review board approved the study protocols. Twenty healthy volunteers were recruited (mean age, 31.2 years; age range, 22-52 years; 14 men, 6 women). Both sparse TOF and parallel imaging (PI) TOF were obtained on a 3 T scanner. Acceleration factors were 3, 4, 5, 6, and 8 for sparse TOF (Sp 3×, Sp 4×, Sp 5×, Sp 6×, and Sp 8×, respectively) and 2, 3, 4, and 6 for PI TOF (PI 2×, PI 3×, PI 4×, and PI 6×, respectively). Images were reconstructed on the scanner, and maximum intensity projection images were subjected to visual evaluation, wherein each segment of the major brain arteries was independently evaluated by 2 radiologists on a 4-point scale (1, poor; 2, limited; 3, moderate/good quality for diagnosis; and 4, excellent). As a quantitative evaluation, the apparent contrast-to-background deviation (apparent CBD) was calculated at the level of the basilar artery and the pons. RESULTS: A total number of 1800 segments were subjectively evaluated. There was substantial agreement regarding vessel visualization (κ = 0.759). Sparse TOF received scores above 3 (good for diagnosis) at any acceleration factor up to the third segments of major arteries. The middle and distal segments of PI 4× and PI 6× were graded below 3 (limited or poor diagnostic value). Sp 3×, 4×, 5×, and 6× retained diagnostic information (graded above 3), even at distal segments. The apparent CBD of sparse TOF at any acceleration factor was equivalent to that of PI 2×, whereas the apparent CBD of PI 3×, PI 4×, and PI 6× attenuated with the acceleration factor. CONCLUSIONS: Sparse TOF can achieve better image quality relative to PI TOF at higher acceleration factors. The diagnostic quality of distal branches (A2/3, M4, P4) was maintained with Sp 6×, which achieved a shorter acquisition time less than half of PI 2×.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Adulto , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Adulto Jovem
12.
Magn Reson Med ; 74(6): 1652-60, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25522299

RESUMO

PURPOSE: To integrate, optimize, and evaluate a three-dimensional (3D) contrast-enhanced sparse MRA technique with iterative reconstruction on a standard clinical MR system. METHODS: Data were acquired using a highly undersampled Cartesian spiral phyllotaxis sampling pattern and reconstructed directly on the MR system with an iterative SENSE technique. Undersampling, regularization, and number of iterations of the reconstruction were optimized and validated based on phantom experiments and patient data. Sparse MRA of the whole head (field of view: 265 × 232 × 179 mm(3) ) was investigated in 10 patient examinations. RESULTS: High-quality images with 30-fold undersampling, resulting in 0.7 mm isotropic resolution within 10 s acquisition, were obtained. After optimization of the regularization factor and of the number of iterations of the reconstruction, it was possible to reconstruct images with excellent quality within six minutes per 3D volume. Initial results of sparse contrast-enhanced MRA (CEMRA) in 10 patients demonstrated high-quality whole-head first-pass MRA for both the arterial and venous contrast phases. CONCLUSION: While sparse MRI techniques have not yet reached clinical routine, this study demonstrates the technical feasibility of high-quality sparse CEMRA of the whole head in a clinical setting. Sparse CEMRA has the potential to become a viable alternative where conventional CEMRA is too slow or does not provide sufficient spatial resolution.


Assuntos
Artérias Cerebrais/patologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador , Algoritmos , Humanos , Angiografia por Ressonância Magnética/instrumentação , Meglumina , Compostos Organometálicos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Tamanho da Amostra , Sensibilidade e Especificidade , Integração de Sistemas
13.
Magn Reson Med ; 73(2): 577-85, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24616025

RESUMO

PURPOSE: Use repeated stress paradigms and an approach taken from neurological blood oxygen level dependent (BOLD) functional MRI (fMRI) to derive robust cardiac BOLD measurements. METHODS: Multiple-repetition, single-shot, electrocardiograph-triggered, T2-prepared BOLD balanced steady-state free precession was performed during repeated long breath-holds in 13 volunteers. Nonrigid motion correction was applied to the continuously acquired data and it was analyzed with a general linear model (GLM) taking into account the effects of the breath-hold duration, RR interval, motion, and baseline variations. Both voxel- and region of interest-based analyses were performed. RESULTS: The GLM model was able to isolate the component of the BOLD signal arising from the breath-holds and separate it from the background effects due to the changing heart rate and motion. A significant (P<0.05) BOLD signal increase was observed in the myocardium of healthy volunteers. CONCLUSION: Using a recent elastic motion correction algorithm and adapted acquisition techniques, it was possible to apply fMRI-like strategies for cardiac BOLD MRI in volunteers and derive robust BOLD measurements. The observed slight but significant oxygenation increase in the myocardium of volunteers might be explained by the vasodilator effect of increased CO2 concentration under apnea. Detection of such small physiological changes in volunteers performing breath-holds demonstrates that the method could have potential in identifying low oxygenation regions in the myocardium of patients during stress tests.


Assuntos
Testes de Função Cardíaca/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Miocárdio/metabolismo , Consumo de Oxigênio/fisiologia , Oxigênio/metabolismo , Adulto , Algoritmos , Teste de Esforço/métodos , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Magn Reson Med ; 73(5): 1864-71, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-24934930

RESUMO

PURPOSE: To investigate for the first time the feasibility of aortic four-dimensional (4D) flow at 7T, both contrast enhanced (CE) and non-CE. To quantify the signal-to-noise ratio (SNR) in aortic 4D flow as a function of field strength and CE with gadobenate dimeglumine (MultiHance). METHODS: Six healthy male volunteers were scanned at 1.5T, 3T, and 7T with both non-CE and CE acquisitions. Temporal SNR was calculated. Flip angle optimization for CE 4D flow was carried out using Bloch simulations that were validated against in vivo measurements. RESULTS: The 7T provided 2.2 times the SNR of 3T while 3T provided 1.7 times the SNR of 1.5T in non-CE acquisitions in the descending aorta. The SNR gains achieved by CE were 1.8-fold at 1.5T, 1.7-fold at 3T, and 1.4-fold at 7T, respectively. CONCLUSION: The 7T provides a new tool to explore aortic 4D flow, yielding higher SNR that can be used to push the boundaries of acceleration and resolution. Field strength and contrast enhancement at all fields provide significant improvements in SNR.


Assuntos
Aorta/fisiologia , Aortografia/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Meios de Contraste , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Meglumina/análogos & derivados , Compostos Organometálicos , Adulto , Estudos de Viabilidade , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Razão Sinal-Ruído , Adulto Jovem
15.
Radiology ; 275(1): 245-54, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25325326

RESUMO

PURPOSE: To develop a highly accelerated phase-contrast cardiac-gated volume flow measurement (four-dimensional [4D] flow) magnetic resonance (MR) imaging technique based on spiral sampling and dynamic compressed sensing and to compare this technique with established phase-contrast imaging techniques for the quantification of blood flow in abdominal vessels. MATERIALS AND METHODS: This single-center prospective study was compliant with HIPAA and approved by the institutional review board. Ten subjects (nine men, one woman; mean age, 51 years; age range, 30-70 years) were enrolled. Seven patients had liver disease. Written informed consent was obtained from all participants. Two 4D flow acquisitions were performed in each subject, one with use of Cartesian sampling with respiratory tracking and the other with use of spiral sampling and a breath hold. Cartesian two-dimensional (2D) cine phase-contrast images were also acquired in the portal vein. Two observers independently assessed vessel conspicuity on phase-contrast three-dimensional angiograms. Quantitative flow parameters were measured by two independent observers in major abdominal vessels. Intertechnique concordance was quantified by using Bland-Altman and logistic regression analyses. RESULTS: There was moderate to substantial agreement in vessel conspicuity between 4D flow acquisitions in arteries and veins (κ = 0.71 and 0.61, respectively, for observer 1; κ = 0.71 and 0.44 for observer 2), whereas more artifacts were observed with spiral 4D flow (κ = 0.30 and 0.20). Quantitative measurements in abdominal vessels showed good equivalence between spiral and Cartesian 4D flow techniques (lower bound of the 95% confidence interval: 63%, 77%, 60%, and 64% for flow, area, average velocity, and peak velocity, respectively). For portal venous flow, spiral 4D flow was in better agreement with 2D cine phase-contrast flow (95% limits of agreement: -8.8 and 9.3 mL/sec, respectively) than was Cartesian 4D flow (95% limits of agreement: -10.6 and 14.6 mL/sec). CONCLUSION: The combination of highly efficient spiral sampling with dynamic compressed sensing results in major acceleration for 4D flow MR imaging, which allows comprehensive assessment of abdominal vessel hemodynamics in a single breath hold.


Assuntos
Abdome/irrigação sanguínea , Aumento da Imagem/métodos , Adulto , Idoso , Algoritmos , Suspensão da Respiração , Meios de Contraste , Compressão de Dados , Feminino , Hemodinâmica , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Imageamento por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Software
16.
PLoS One ; 8(12): e82212, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24349224

RESUMO

PURPOSE: Three-dimensional (3D) magnetic resonance phase contrast imaging (PC-MRI) allows non-invasive diagnosis of pulmonary hypertension (PH) and estimation of elevated mean pulmonary arterial pressure (mPAP) based on vortical motion of blood in the main pulmonary artery. The purpose of the present study was to compare the presence and duration of PH-associated vortices derived from different flow visualization techniques with special respect to their performance for non-invasive assessment of elevated mPAP and diagnosis of PH. METHODS: Fifty patients with suspected PH (23 patients with and 27 without PH) were investigated by right heart catheterization and time-resolved PC-MRI of the main pulmonary artery. PC-MRI data were visualized with dedicated prototype software, providing 3D vector, multi-planar reformatted (MPR) 2D vector, streamline, and particle trace representation of flow patterns. Persistence of PH-associated vortical blood flow (tvortex) was evaluated with all visualization techniques. Dependencies of tvortex on visualization techniques were analyzed by means of correlation and receiver operating characteristic (ROC) curve analysis. RESULTS: tvortex values from 3D vector visualization correlated strongly with those from other visualization techniques (r = 0.98, 0.98 and 0.97 for MPR, streamline and particle trace visualization, respectively). Areas under ROC curves for diagnosis of PH based on tvortex did not differ significantly and were 0.998 for 3D vector, MPR vector and particle trace visualization and 0.999 for streamline visualization. Correlations between elevated mPAP and tvortex in patients with PH were r = 0.96, 0.93, 0.95 and 0.92 for 3D vector, MPR vector, streamline and particle trace visualization, respectively. Corresponding standard deviations from the linear regression lines ranged between 3 and 4 mmHg. CONCLUSION: 3D vector, MPR vector, streamline as well as particle trace visualization of time-resolved 3D PC-MRI data of the main pulmonary artery can be employed for accurate vortex-based diagnosis of PH and estimation of elevated mPAP.


Assuntos
Pressão Arterial/fisiologia , Hipertensão Pulmonar/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Artéria Pulmonar/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Demografia , Feminino , Humanos , Hipertensão Pulmonar/diagnóstico , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Curva ROC , Fluxo Sanguíneo Regional , Sístole , Adulto Jovem
17.
Neuroradiology ; 55(4): 389-98, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23143179

RESUMO

INTRODUCTION: 4D phase contrast MR imaging (4D PC MRI) has been introduced for spatiotemporal evaluation of intracranial hemodynamics in various cerebrovascular diseases. However, it still lacks validation with standards of reference. Our goal was to compare blood flow quantification derived from 4D PC MRI with transcranial ultrasound and 2D PC MRI. METHODS: Velocity measurements within large intracranial arteries [internal carotid artery (ICA), basilar artery (BA), and middle cerebral artery (MCA)] were obtained in 20 young healthy volunteers with 4D and 2D PC MRI, transcranial Doppler sonography (TCD), and transcranial color-coded duplex sonography (TCCD). Maximum velocities at peak systole (PSV) and end diastole (EDV) were compared using regression analysis and Bland-Altman plots. RESULTS: Correlation of 4D PC MRI measured velocities was higher in comparison with TCD (r = 0.49-0.66) than with TCCD (0.35-0.44) and 2D PC MRI (0.52-0.60). In mid-BA and ICA C7 segment, a significant correlation was found with TCD (0.68-0.81 and 0.65-0.71, respectively). No significant correlation was found in carotid siphon. On average over all volunteers, PSVs and EDVs in MCA were minimally underestimated compared with TCD/TCCD. Minimal overestimation of velocities was found compared to TCD in mid-BA and ICA C7 segment. CONCLUSION: 4D PC MRI appears as valid alternative for intracranial velocity measurement consistent with previous reference standards, foremost with TCD. Spatiotemporal averaging effects might contribute to vessel size-dependent mild underestimation of velocities in smaller (MCA), and overestimation in larger-sized (BA and ICA) arteries, respectively. Complete spatiotemporal flow analysis may be advantageous in anatomically complex regions (e.g. carotid siphon) relative to restrictions of ultrasound techniques.


Assuntos
Algoritmos , Artérias Cerebrais/fisiologia , Circulação Cerebrovascular/fisiologia , Ecoencefalografia/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Adulto , Velocidade do Fluxo Sanguíneo/fisiologia , Artérias Cerebrais/anatomia & histologia , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
18.
J Magn Reson Imaging ; 35(1): 190-5, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21990271

RESUMO

PURPOSE: To evaluate the performance of four-dimensional (4D) flow-sensitive MRI in the thoracic aorta using 12- and 32-channel coils and parallel imaging. MATERIALS AND METHODS: 4D flow-sensitive MRI was performed in the thoracic aorta of 11 healthy volunteers at 3 Tesla (T) using different coils and parallel imaging (GRAPPA) accelerations (R): (i) 12-channel coil, R = 2; (ii) 12-channel coil, R = 3; (iii) 32-channel coil, R = 3. The quantitative analysis included SNR, residual velocity divergence and length and curvature of traces (streamlines and pathlines) as used for 3D flow visualization. In addition, semi-quantitative image grading was performed to assess quality of phase-contrast angiography and 3D flow visualization. RESULTS: Parallel imaging with an acceleration factor R = 3 allowed to save 19.5 ± 5% measurement time compared with R = 2 (14.2 ± 2.4 min). Acquisition using 12 channels with R = 2 and 32 channels with R = 3 produced data with significantly (P < 0.05) higher quality compared with 12 channels and R = 3. There was no significant difference between 12 channels with R = 2 and 32 channels with R = 3 but for the depiction of supra-aortic branches where the 32-channel coil proved superior. CONCLUSION: Using 32-channel coils is beneficial for 4D flow-sensitive MRI of the thoracic aorta and can allow for a reduction of total scan time while maintaining overall image quality.


Assuntos
Aorta Torácica/patologia , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Algoritmos , Velocidade do Fluxo Sanguíneo , Sistema Cardiovascular/patologia , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Reprodutibilidade dos Testes
19.
Magn Reson Med ; 66(4): 966-75, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21437975

RESUMO

The purpose of this study was to explore how to optimally undersample and reconstruct time-resolved 3D data using a k-t-space-based GRAPPA technique. The performance of different reconstruction strategies was evaluated using data sets with different ratios of phase (N(y)) and partition (N(z)) encoding lines (N(y) × N(z) = 64-128 × 40-64) acquired in a moving phantom. Image reconstruction was performed for different kernel configurations and different reduction factors (R = 5, 6, 8, and 10) and was evaluated using regional error quantification and SNR analysis. To analyze the temporal fidelity of the different kernel configurations in vivo, time-resolved 3D phase contrast data were acquired in the thoracic aorta of two healthy volunteers. Results demonstrated that kernel configurations with a small kernel extension yielded superior results especially for more asymmetric data matrices as typically used in clinical applications. The application of k-t-GRAPPA to in vivo data demonstrated the feasibility of undersampling of time-resolved 3D phase contrast data set with a nominal reduction factors of up to R(net) = 8, while maintaining the temporal fidelity of the measured velocity field. Extended GRAPPA-based parallel imaging with optimized multidimensional reconstruction kernels has the potential to substantially accelerate data acquisitions in time-resolved 3D MRI.


Assuntos
Aorta/anatomia & histologia , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Algoritmos , Aorta/fisiologia , Artefatos , Velocidade do Fluxo Sanguíneo , Aumento da Imagem/métodos , Imagens de Fantasmas , Fatores de Tempo
20.
J Magn Reson Imaging ; 33(4): 839-46, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21448948

RESUMO

PURPOSE: To assess blood flow velocities and spatial distribution of aortic Reynolds numbers in vivo using flow-sensitive magnetic resonance imaging (MRI) and probe for flow instabilities along the aorta based on an empirical model for physiological pulsatile blood flow. MATERIALS AND METHODS: Thirty young healthy volunteers were examined by flow-sensitive MRI at eight imaging planes distributed along the thoracic aorta. Flow, Womersley, Strouhal, Reynolds, and critical Reynolds numbers were calculated and used to assess the presence of flow instabilities. RESULTS: The average peak Reynolds number was higher in the ascending (≈4500) and descending aorta (≈4200) than in the aortic arch (≈3400). According to the calculated critical Reynolds numbers, flow instabilities were prominent in the ascending (14/30 volunteers) and descending aorta (22/30 volunteers) but not in the aortic arch (3/30 volunteers). A significant difference (P < 0.05) in supracritical peak Reynolds numbers was observed between genders. The supracritical Reynolds number, indicating flow instabilities, significantly correlated (P < 0.05) with body weight (r = 0.34), aortic diameter (r = 0.48), and cardiac output (r = 0.53). CONCLUSION: Flow-sensitive MRI was used to indirectly assess the presence of flow instabilities in vivo. The results in volunteers indicate the presence of flow instabilities in the young healthy aorta with a higher prevalence for men than women.


Assuntos
Aorta/patologia , Diagnóstico por Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Fluxo Pulsátil , Adulto , Algoritmos , Aorta Torácica/patologia , Velocidade do Fluxo Sanguíneo/fisiologia , Estudos de Coortes , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Modelos Estatísticos , Prevalência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...