1.
Ophthalmol Glaucoma ; 6(3): 239-246, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36435449

RESUMO

PURPOSE: Portable perimetric testing could be useful for community-based glaucoma screening programs. Frequency-doubling technology (FDT) and the Moorfields motion displacement test (MDT) are portable perimeters that have shown promise as potential screening tools for glaucoma. This study's goal was to determine the diagnostic accuracy of FDT and MDT for visual field defects and glaucoma. DESIGN: Prospective, cross-sectional, diagnostic accuracy study. PARTICIPANTS: A consecutive series of patients aged ≥ 50 years who presented to a glaucoma clinic in South India and had never undergone Humphrey field analyzer (HFA) visual field testing in the past. METHODS: Participants underwent 24-2 Swedish Interactive Thresholding Algorithm (SITA) Standard HFA perimetry, FDT perimetry, MDT perimetry, and iPad perimetry using visualFields Easy in random order. Ophthalmologist grades of HFA and optic nerve head photographs were used as reference standards for glaucoma and field defect presence. Receiver operating characteristic curves were constructed to assess the diagnostic accuracy of various parameters for each test. MAIN OUTCOME MEASURES: Sensitivity, specificity, and area under the receiver operating characteristic curve (AUROC). RESULTS: Overall, 292 eyes from 173 participants were included, with 112 eyes classified as moderate or worse glaucoma. For moderate or worse glaucoma detection, the best parameter on FDT was mean deviation (MD) (AUROC, 0.84; 95% confidence interval [CI], 0.79-0.89) and the best parameter on MDT was global probability of true damage (GPTD) (AUROC, 0.87; 95% CI, 0.82-0.91). When specificity was set to 90%, the sensitivity for detection of moderate or worse glaucoma was 55% (95% CI, 39%-68%) for FDT MD and 62% (95% CI 52%-71%) for MDT GPTD. CONCLUSIONS: Frequency-doubling technology and MDT perimetry had fair diagnostic accuracy for glaucoma detection when administered to naïve test takers in this South Indian population. Although not appropriate for use as a sole glaucoma screening test, these perimetric tests may be useful as ancillary tests. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.


Assuntos
Glaucoma , Campos Visuais , Humanos , Estudos Transversais , Estudos Prospectivos , Sensibilidade e Especificidade , Glaucoma/diagnóstico , Testes de Campo Visual
2.
Eye (Lond) ; 37(8): 1690-1695, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36064770

RESUMO

BACKGROUND/OBJECTIVES: Tablet-based perimetry could be used to test for glaucomatous visual field defects in settings without easy access to perimeters, although few studies have assessed diagnostic accuracy of tablet-based tests. The goal of this study was to determine the diagnostic accuracy of iPad perimetry using the visualFields Easy application. SUBJECTS/METHODS: This was a prospective, cross-sectional study of patients undergoing their first Humphrey Field Analyser (HFA) visual field test at a glaucoma clinic in India. Participants underwent 24-2 SITA Standard HFA testing and iPad-based perimetry with the visualFields Easy application. Reference standards for both visual field loss and suspected glaucoma were determined by ophthalmologist review of HFA results and optic disc photographs. Receiver operating characteristic curves were constructed to assess diagnostic accuracy at various test thresholds. RESULTS: 203 eyes from 115 participants were included, with 82 eyes classified as moderate or worse glaucoma. iPad perimetry had an area under the receiver operating characteristic (AUROC) curve of 0.64 (95% CI 0.57 to 0.71) for detection of any visual field defect relative to HFA and an AUROC of 0.68 (0.59 to 0.76) for detection of moderate or worse glaucoma relative to ophthalmologist examination. At a set specificity of 90%, the sensitivity of iPad perimetry for detection of moderate or worse glaucoma was 35% (22-48%). CONCLUSIONS: iPad perimetry using the visualFields Easy application had inadequate diagnostic accuracy to be used as a screening tool for glaucoma in this South Indian population.


Assuntos
Glaucoma , Testes de Campo Visual , Humanos , Testes de Campo Visual/métodos , Campos Visuais , Estudos Transversais , Estudos Prospectivos , Sensibilidade e Especificidade , Glaucoma/diagnóstico , Glaucoma/epidemiologia , Curva ROC , Transtornos da Visão/diagnóstico
3.
J Glaucoma ; 31(7): 590-594, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35763681

RESUMO

PRCIS: Corneal hysteresis (CH) measurements are relatively stable during routine follow up of glaucoma patients over an intermediate time frame. Cataract surgery does not change the CH significantly after an average follow up of 6 months. PURPOSE: The aim was to assess the repeatability of CH measurements in glaucoma patients over time, during routine follow up and after cataract surgery. MATERIALS AND METHODS: Retrospective analysis of patients records in a glaucoma clinic where routine measurements by the Ocular Response Analyzer were done. Patients with at least 2 CH measurements were included. Repeatability was assessed using the intraclass correlation coefficient (ICC). RESULTS: A total of 164 eyes (87 patients) were included. Twenty-eight of them had measurements before and after cataract surgery with mean follow up time of 29.64±9.63 weeks. There was no evidence for a difference in CH between the before and after cataract surgery measurements (ICC=0.79, 95% confidence interval: 0.60-0.89). In the remaining 136 eyes, without any surgical treatment between measurements, there was moderate agreement among the repeated CH measurements (ICC=0.64, 95% confidence interval: 0.61-0.82) with mean time of 32.06±25.32 weeks between first and last measurement. CONCLUSION: CH measurements in glaucoma patients were repeatable over a 6-month period during routine follow up or following cataract surgery. These findings suggest that the intraocular pressure reduction following cataract surgery is unlikely to be because of a change in this biomechanical property.


Assuntos
Catarata , Glaucoma , Seguimentos , Glaucoma/complicações , Glaucoma/diagnóstico , Humanos , Pressão Intraocular , Estudos Retrospectivos
4.
Ophthalmol Glaucoma ; 5(3): 345-352, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34547504

RESUMO

PURPOSE: To determine the diagnostic accuracy of potential screening tests for moderate to advanced glaucoma. DESIGN: Prospective diagnostic test accuracy study. PARTICIPANTS: The study enrolled a consecutive series of patients aged ≥50 years who presented to a glaucoma clinic in South India without ever having received automated visual field testing. METHODS: All participants underwent 8 index tests: OCT of the peripapillary retinal nerve fiber layer, optic disc photography, Moorfield's Motion Displacement Test (MDT), frequency doubling technique perimetry, noncontact tonometry, pneumatonometry, presenting visual acuity, and best-corrected visual acuity. Participants also underwent stereoscopic photographs and Humphrey visual fields, which were used by 2 ophthalmologists to arrive at the reference standard diagnosis of moderate to advanced glaucoma. MAIN OUTCOME MEASURES: Sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio. RESULTS: A total of 217 people were enrolled; 321 eyes from 180 participants had all tests performed. Of these, 127 eyes (40%) were classified as having moderate to advanced glaucoma. Among the 8 tests, OCT best optimized sensitivity (84%, 95% confidence interval [CI], 76-90) and specificity (75%, 95% CI, 68-81). Moorfield's Motion Displacement Test was the best perimetric test, with a sensitivity of 91% (95% CI, 85-96) and specificity of 53% (95% CI, 44-61). Pressure and vision tests were not sensitive (e.g., sensitivity of 16%, 95% CI, 9-23 for noncontact tonometry and 23%, 95% CI, 15-31 for best-corrected visual acuity). Moorfield's Motion Displacement Test identified 16 of 127 eyes (13%) with glaucoma that were not captured by OCT, but also had false-positive results in 65 of 194 eyes (34%) without glaucoma that OCT correctly classified as negative. CONCLUSIONS: OCT had moderate sensitivity and fair specificity for diagnosing moderate to advanced glaucoma and should be prioritized during an initial assessment for glaucoma.


Assuntos
Glaucoma , Fibras Nervosas , Glaucoma/diagnóstico , Humanos , Manometria , Estudos Prospectivos , Sensibilidade e Especificidade , Tomografia de Coerência Óptica/métodos , Acuidade Visual , Testes de Campo Visual/métodos
5.
Int J Ophthalmol ; 14(11): 1721-1728, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34804862

RESUMO

AIM: To evaluate aspects of cognition impacted by individuals with and without normal tension glaucoma. METHODS: Fifty normal tension glaucoma (NTG) and 50 control patients ≥50y of age were recruited from the UCSF Department of Ophthalmology. Demographic data and glaucoma parameters were extracted from electronic medical records for both groups. Tests of executive function [Executive Abilities: Measures and Instruments for Neurobehavioral Evaluation and Research (EXAMINER)] and learning and memory [California Verbal Learning Test-Second Edition (CVLT-II)] were administered to both NTG and controls. Race, handedness, best-corrected visual acuity, maximum intraocular pressure, optic nerve cup-to-disc ratio, visual field and optic nerve optical coherence tomography parameters, and a measure of general health (Charlson Comorbidity Index) were compared between NTG and controls as well as within NTG subgroups. Multivariate linear regression was used to compare group performances on the EXAMINER battery and CVLT-II while controlling for age, sex, and years of education. RESULTS: NTG and controls were comparable with respect to age, sex, race, education, handedness, and the Charlson Comorbidity Index (P>0.05 for all). Performance on the EXAMINER composite score and the CVLT-II did not differ between NTG and controls (P>0.05 for both). CONCLUSION: This is the first prospective study in which the cognitive function of subject with NTG were evaluated using a comprehensive, computerized neurocognitive battery. Subjects with NTG do not perform worse than unaffected controls on tests of executive function, learning, and memory. Results do not support the hypothesis that individuals with NTG are at higher risk for cognitive dysfunction and/or dementia.

6.
PLoS One ; 16(5): e0251583, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34010350

RESUMO

PURPOSE: Autorefractors allow non-specialists to quickly assess refractive error, and thus could be a useful component of large-scale vision screening programs. In order to better characterize the role of autorefraction for public health outreach programs in resource-limited settings, the diagnostic accuracy of two autorefractors was assessed relative to subjective refraction in an adult Indian population. METHODS: An optometrist refracted a series of patients aged ≥50 years at an eye clinic in Bangalore, India using the Nidek ARK-900 autorefractor first, followed by the 3nethra Royal autorefractor, and then subjective refraction. The diagnostic accuracy of each autorefractor for myopia, hyperopia, and astigmatism was assessed using subjective refraction as the reference standard, and measures of agreement between refractions were calculated. RESULTS: A total of 197 eyes in 104 individuals (mean age 63 ± 8 years, 52% female) were evaluated. Both autorefractors produced spherical equivalent estimates that were on average more hyperopic than subjective refraction, with a measurement bias of +0.16 D (95%CI +0.09 to +0.23D) for Nidek and +0.42 D (95%CI +0.28 to +0.54D) for 3nethra. When comparing pairs of measurements from autorefraction and subjective refraction, the limits of agreement were approximately ±1D for the Nidek autorefractor and ±1.75D for the 3Nethra autorefractor. The sensitivity and specificity of detecting ≥1 diopter of myopia were 94.6% (95%CI 86.8-100%) and 92.5% (95%CI 88.9-97.5%) for the Nidek, and 89.2% (95%CI 66.7-97.4) and 77.5% (95%CI 71.2-99.4%) for the 3Nethra. The accuracy of each autorefractor increased at greater levels of refractive error. CONCLUSIONS: The sensitivity and specificity of the Nidek autorefractor for diagnosing refractive error among adults ≥50 years in an urban Indian clinic was sufficient for screening for visually significant refractive errors, although the relatively wide limits of agreement suggest that subjective refinement of the eyeglasses prescription would still be necessary.


Assuntos
Erros de Refração/diagnóstico , Idoso , Astigmatismo/diagnóstico , Astigmatismo/epidemiologia , Feminino , Humanos , Hiperopia/diagnóstico , Hiperopia/epidemiologia , Índia/epidemiologia , Masculino , Pessoa de Meia-Idade , Miopia/diagnóstico , Miopia/epidemiologia , Estudos Prospectivos , Refração Ocular , Erros de Refração/epidemiologia , Seleção Visual
7.
Curr Eye Res ; 46(9): 1428-1431, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33550863

RESUMO

Purpose: Previous studies have used subjective assessments to implicate darker skin color as a risk factor for glaucoma. This study used objective measurements to determine whether skin melanin is a risk factor for glaucoma.Methods: In a case-control study conducted at a tertiary eye hospital in Nepal, patients aged 40 years or older from the glaucoma clinic were enrolled as cases and age-matched patients without glaucoma from other clinics at the eye hospital were enrolled as controls. A colorimeter was used to capture melanin measurements in triplicate from the inner arm and forehead of each participant. The exposure variable of interest was the median skin melanin value, in arbitrary units. The outcome of interest was the presence of glaucoma.Results: 100 glaucoma cases and 100 matched controls were enrolled. Agreement between the triplicate melanin measurements was high, with an intra-class correlation of 0.99 (95% CI, 0.99-0.99) for inner arm measurements and 0.97 (95% CI 0.96-0.98) for forehead measurements. Mean inner arm melanin values were 604 units (standard deviation [SD] 177) in cases and 602 units (SD 179) in controls; forehead values were 650 (SD 146) in cases and 652 (SD 152) in controls. After adjusting for sex and country of residence, skin melanin was not associated with the presence of glaucoma (odds ratio 1.04, 95%CI 0.78-1.38 for inner arm values and 0.97, 95%CI 0.70-1.35 for forehead values).Conclusion: This study failed to find a significant association between skin pigmentation and glaucoma.


Assuntos
Glaucoma/etiologia , Melaninas/metabolismo , Pigmentação da Pele/fisiologia , Pele/metabolismo , Adulto , Idoso , Estudos de Casos e Controles , Feminino , Seguimentos , Glaucoma/diagnóstico , Glaucoma/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Pele/patologia
8.
Ophthalmol Sci ; 1(2)2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35756578

RESUMO

Purpose: To investigate ON-pathway versus OFF-pathway dysfunction in glaucoma using handheld electroretinography (ERG) with a temporally modulated sinusoidal flicker stimulus. Design: Cross-sectional study. Participants: Fifty-nine participants accounting for 104 eyes, comprised of 19 control eyes, 26 glaucoma suspect eyes, and 59 glaucoma eyes. Methods: Participants underwent portable ERG testing, which included the photopic flash, photopic flicker, photopic negative response stimulus, ON-OFF stimulus, and a custom-written sinusoidal flicker stimulus that was modulated from 50 to 0.3 Hz. Main Outcome and Measures: The ERG response amplitudes were measured by the handheld ERG. For the custom-written sinusoidal flicker stimulus, we derived and compared the log10 first harmonic frequency response amplitudes. Patient discomfort and fatigue after ERG testing were rated on a scale from 1 to 5. Results: Baseline demographics were not significantly different between groups, except for ocular characteristics. Analysis was performed adjusting for participant age, sex, race, and dilation status, and the sinusoidal frequency responses were stratified at 10 Hz because higher frequencies are associated with the OFF-pathway, whereas lower frequencies are associated with the ON-pathway. After stratification, glaucoma eyes showed an adjusted decrease of 32.1% at frequencies of more than 10 Hz (95% confidence interval [CI], -51.8% to -4.1%; P = 0.03). For 10 Hz stimulus frequencies or less, an adjusted 11.5% reduction was found (95% CI, -39.5% to 29.1%; P = 0.50). Glaucoma suspect eyes did show a decreased response, but this was not significant at either frequency range. When comparing handheld ERG with traditional visual field assessments, participants found the handheld ERG to result in much less discomfort and fatigue. Conclusions: Our finding that glaucoma participants showed greater decreases in ERG response at higher frequencies supports the hypothesis that the OFF-pathway may be more vulnerable in human glaucoma. Using a handheld ERG device with a sinusoidal flicker stimulus may provide an objective assessment of visual function in glaucoma.

9.
J Glaucoma ; 29(12): 1143-1146, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32890103

RESUMO

PRéCIS:: In a case-control study, skin pigmentation was not statistically significantly different when comparing glaucoma patients to those without glaucoma. PURPOSE: Darker skin color has been implicated as a risk factor for glaucoma based on previous studies' subjective assessments of skin pigmentation. This study used objective measurements to determine whether cutaneous pigmentation is a risk factor for glaucoma. METHODS: This case-control study was conducted at Menelik II Tertiary Referral Hospital in Addis Ababa, Ethiopia. Patients aged 40 years or older from the glaucoma clinic who were being scheduled for trabeculectomy were enrolled as cases and age-matched patients without glaucoma from other clinics at Menelik II Tertiary Referral Hospital were enrolled as controls. A Dermacatch device was used to capture melanin measurements in triplicate from the inner arm of each participant. The exposure variable of interest was the median of the triplicate skin melanin measurements, in arbitrary units. The outcome of interest was presence of glaucoma. RESULTS: Agreement between the triplicate inner arm melanin measurements was high, with an intraclass correlation of 0.99 (95% confidence interval, 0.98-0.99). Mean melanin values were 704 units (SD 94) in 76 cases and 694 units (SD 93) in 152 controls. Melanin was not statistically significantly associated with glaucoma after adjusting for sex and season of measurement (ie, dry vs. rainy), with an odds ratio of 1.15 (95% confidence interval, 0.59-2.24) per 100 units of inner arm melanin. CONCLUSION: This study failed to find a significant association between skin pigmentation and glaucoma using an objective and reproducible assessment of pigmentation.


Assuntos
Glaucoma de Ângulo Aberto/fisiopatologia , Glaucoma de Ângulo Aberto/cirurgia , Melaninas/metabolismo , Pigmentação da Pele/fisiologia , Pele/metabolismo , Trabeculectomia , Adulto , Idoso , Estudos de Casos e Controles , Etiópia , Feminino , Glaucoma de Ângulo Aberto/metabolismo , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Hipertensão Ocular/metabolismo , Hipertensão Ocular/fisiopatologia , Hipertensão Ocular/cirurgia , Razão de Chances , Transtornos da Pigmentação , Fatores de Risco , Centros de Atenção Terciária , Tonometria Ocular
10.
Ophthalmol Glaucoma ; 3(5): 384-392, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32980043

RESUMO

PURPOSE: To elucidate the vision loss and recovery course after the Ahmed tube shunt procedure 6 months postoperatively. To identify risk factors associated with significant vision loss. DESIGN: Retrospective chart review. PARTICIPANTS: One eye of all adult patients who underwent an Ahmed glaucoma valve procedure from January 2008 to December 2017 with a minimum 6-month follow-up. METHODS: Patients' preoperative and postoperative corrected visual acuity (CVA) were documented for 1 week, 1 month, 3 months, and 6 months postoperatively. MAIN OUTCOME MEASURES: Preoperative and postoperative CVA at various time points were compared using repeated-measures analysis of variance. The proportions of patients with mild (<3 lines of Snellen CVA loss), moderate (3-5 lines, inclusive), and severe (>5 lines) vision loss were calculated and compared using a chi-square test. Logistic regression analysis was conducted to identify risk factors associated with a loss of 3 or more lines of CVA 6 months after surgery. RESULTS: A total of 375 patients were included, whose mean preoperative CVA was 0.76. At 1 week postoperatively, mean CVA worsened to 0.96 (P < 0.05), but recovered back to preoperative level by the third postoperative month (P > 0.05). In terms of any vision loss, 55.6% of patients had worse CVA than preoperation at 1 week postoperatively, including 23.5% who had 3 or more lines of vision loss; these proportions decreased to 39.2% (P < 0.001) and 9.3%, respectively, by 6 months postoperatively. The most common causes of significant vision loss were preexisting ocular conditions and cataract progression. Postoperative antimetabolite injection was associated with a lower risk of 3 or more lines of CVA loss 6 months postoperatively (odds ratio, 0.44; P = 0.023). CONCLUSIONS: After the Ahmed tube shunt procedure, the worst CVA occurred at 1 week postoperatively and mean CVA returned to the preoperative level by month 3 postoperatively. Approximately 40% of patients had any CVA loss compared with preoperation, and 9.3% of patients had 3 or more lines of CVA loss at month 6 postoperatively. Postoperative antimetabolite injection was associated with a lower risk of 3 or more lines of postoperative vision loss.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma/cirurgia , Pressão Intraocular/fisiologia , Recuperação de Função Fisiológica , Acuidade Visual , Feminino , Seguimentos , Glaucoma/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Retrospectivos
11.
J Glaucoma ; 29(7): 561-566, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32224804

RESUMO

PRéCIS:: Publications in glaucoma have seen an increase in the number of authors and disclosures per article, authors with dual degrees, and international authors, but contributions of women to articles published remains low. PURPOSE: Authorship trends have been studied across many medical specialties and in ophthalmology as a whole, but not specifically in glaucoma. The authors explored the authorship trends of original scientific articles in the Journal of Glaucoma. MATERIALS AND METHODS: The authors recorded the number of authors and disclosures per article, degree type of first and last authors, geographical origin of the corresponding author, and sex of first and last authors of original content from the Journal of Glaucoma published in 1992, 1997, 2002, 2007, 2012, and 2017. RESULTS: A total of 642 articles were analyzed. From 1992 to 2017, annual published articles increased from 38 to 242 (P=0.02), the mean number of authors per article increased from 3.2 to 5.2 (P<0.01), the mean number of disclosures per article increased from 0.3 to 1.0 (P=0.04), the proportion of first and last authors with dual degrees (medical plus advanced degrees) also increased (both P<0.03), whereas the proportion with a sole medical degree decreased (both P<0.05). There was a proportional decrease in articles from North America (P=0.03), and proportional increase from the "Far East" (P=0.04) and "Other" regions (P=0.04). No significant changes in proportions of female first and last authors were found (both P>0.28). CONCLUSIONS: Consistent with authorship trends across various other medical specialties, glaucoma has seen an increase in the number of authors and disclosures per article, authors with dual degrees, and authors from the "Far East" and "Other" regions. However, contributions of women to articles published in Journal of Glaucoma remain low.


Assuntos
Autoria , Oftalmologia/tendências , Publicações Periódicas como Assunto/tendências , Editoração/tendências , Bibliometria , Feminino , Glaucoma , Humanos , Masculino , Distribuição por Sexo
12.
PLoS One ; 14(8): e0220362, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31393904

RESUMO

PURPOSE: Glaucoma screening can be performed by assessing the vertical-cup-to-disk ratio (VCDR) of the optic nerve head from fundus photography, but VCDR grading is inherently subjective. This study investigated whether computer software could improve the accuracy and repeatability of VCDR assessment. METHODS: In this cross-sectional diagnostic accuracy study, 5 ophthalmologists independently assessed the VCDR from a set of 200 optic disk images, with the median grade used as the reference standard for subsequent analyses. Eight non-ophthalmologists graded each image by two different methods: by visual inspection and with assistance from a custom-made publicly available software program. Agreement with the reference standard grade was assessed for each method by calculating the intraclass correlation coefficient (ICC), and the sensitivity and specificity determined relative to a median ophthalmologist grade of ≥0.7. RESULTS: VCDR grades ranged from 0.1 to 0.9 for visual assessment and from 0.1 to 1.0 for software-assisted grading, with a median grade of 0.4 for each. Agreement between each of the 8 graders and the reference standard was higher for visual inspection (median ICC 0.65, interquartile range 0.57 to 0.82) than for software-assisted grading (median ICC 0.59, IQR 0.44 to 0.71); P = 0.02, Wilcoxon signed-rank test). Visual inspection and software assistance had similar sensitivity and specificity for detecting glaucomatous cupping. CONCLUSION: The computer software used in this study did not improve the reproducibility or validity of VCDR grading from fundus photographs compared with simple visual inspection. More clinical experience was correlated with higher agreement with the ophthalmologist VCDR reference standard.


Assuntos
Bases de Dados Factuais , Fundo de Olho , Glaucoma/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Oftalmoscopia , Disco Óptico/diagnóstico por imagem , Adulto , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes
13.
Ophthalmol Glaucoma ; 2(6): 429-434, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32672576

RESUMO

PURPOSE: To evaluate the agreement between Goldmann applanation tonometry (GAT; Haag-Streit, Bern, Switzerland) and several portable tonometers that could be used for glaucoma screening programs. DESIGN: Evaluation of a diagnostic test. PARTICIPANTS: Three hundred twenty-one eyes of 168 participants seeking treatment at the glaucoma clinic of a tertiary eye hospital in India. METHODS: Participants underwent intraocular pressure (IOP) measurement with GAT and 4 index tests: the Icare TA01i rebound tonometer (Icare USA, Raleigh, NC), a noncontact tonometer (NCT; Topcon CT-80; Topcon; Tokyo, Japan), a pneumatonometer (Model 30; Reichert Technologies; Depew, NY), and the Tono-Pen AVIA (Reichert Technologies). MAIN OUTCOME MEASURES: Estimates of reproducibility of IOP measurements between each index test and GAT, including the intraclass correlation coefficient (ICC) and the Bland-Altman 95% limits of agreement. RESULTS: The Icare showed the greatest agreement with GAT (ICC, 0.69; 95% confidence interval, 0.61-0.74), followed by the NCT (ICC, 0.65; 95% confidence interval, 0.58-0.71), the Tono-Pen (ICC, 0.51; 95% confidence interval, 0.43-0.59), and the pneumatonometer (ICC, 0.36; 95% confidence interval, 0.27-0.44). The pneumatonometer and Tono-Pen tended to overestimate IOP relative to GAT, with a mean difference of 3.4 mmHg (95% limits of agreement [LOA], -7.3 to 14.1 mmHg) for the pneumatonometer and 3.2 mmHg (95% LOA, -6.1 to 12.6 mmHg) for the Tono-Pen. In contrast, measurements from the Icare and NCT were on average within 1 point of those for GAT (mean difference, -0.4 mmHg [95% LOA, -8.4 to 7.6 mmHg] and -0.5 mmHg [95% LOA, -8.7 to 7.6 mmHg], respectively). CONCLUSIONS: The Icare and NCT both demonstrated good agreement with GAT across a wide range of IOPs and could be considered for glaucoma screening programs.


Assuntos
Glaucoma/diagnóstico , Pressão Intraocular/fisiologia , Tonometria Ocular/métodos , Estudos Transversais , Feminino , Glaucoma/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
15.
J Glaucoma ; 26(9): e214-e216, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28671925

RESUMO

PURPOSE: Systemic absorption and central nervous system (CNS) penetration of timolol drops are a well-studied phenomenon, resulting in common side effects such as bradycardia, bronchospasm, fatigue, and confusion. More serious CNS side effects, such as psychosis and depression, however, are rarely attributed to eye drops. We report a case series in which patients developed visual hallucinations secondary to topical ocular timolol use. METHODS: This study is a case series and review of the literature. RESULTS: Four patients with glaucoma developed visual hallucinations while using topical timolol. The patients were all elderly, caucasian females with associated CNS pathology. All patients had resolution of symptoms upon discontinuation and a positive retrial test to confirm the association. CONCLUSIONS: The rarity of this side effect and its anecdotal predilection for elderly, caucasian females with underlying neurological dysfunction, may involve a yet unknown predisposition or hypersensitivity to beta blocker action, such as blood brain barrier disruption leading to increased susceptibility to the medication. This case series highlights an important, although rare, side effect of this medication which clinicians should be aware of especially when using it in elderly patients who may have coexisting CNS pathology. It is important that this side effect be recognized and appropriately managed to prevent otherwise unnecessary investigations and treatment.


Assuntos
Glaucoma/tratamento farmacológico , Alucinações/induzido quimicamente , Pressão Intraocular , Timolol/efeitos adversos , Administração Tópica , Idoso , Idoso de 80 Anos ou mais , Anti-Hipertensivos/efeitos adversos , Anti-Hipertensivos/uso terapêutico , Feminino , Humanos , Soluções Oftálmicas/efeitos adversos , Timolol/uso terapêutico
16.
Clin Exp Ophthalmol ; 45(2): 128-134, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27490793

RESUMO

BACKGROUND: To examine the effect of mitomycin c and 5-flurouracil on treatment outcomes following Ahmed glaucoma valve implantation. DESIGN: Retrospective consecutive case series. PARTICIPANTS: Fifty patients who received Ahmed glaucoma valve implantation from 1999 to 2013 in the San Francisco Veterans Administration Hospital. METHODS: The +INJECTION group received intraoperative mitomycin c followed by postoperative mitomycin c and/or 5-flurouracil, whereas the -INJECTION group did not. MAIN OUTCOME MEASURES: Primary outcome was treatment success at 1 year post-implantation. Intraocular pressure, hypertensive phase, and the number of glaucoma medications were also examined. RESULTS: Twenty-six patients/eyes in the +INJECTION group and 24 patients/eyes in the -INJECTION group were included. Treatment success was higher in the +INJECTION compared with the -INJECTION group (86 vs. 58%; P = 0.04). Intraocular pressure was lower in the +INJECTION compared with the -INJECTION group at 1, 3, 6 and 12 months (P ≪ 0.00001, P = 0.00003, 0.0008 and 0.024). Hypertensive phase occurred less often in the +INJECTION compared with the -INJECTION group (3.8 vs. 54%; P = 0.021). The +INJECTION group required fewer medications compared with the -INJECTION group (P = 0.02, 0.002, 0.003 and 0.008 at 1, 3, 6 and 12 months). Complication rates were comparable between groups (46.2 and 54.2%; P = 0.63). CONCLUSIONS: Adjuvant treatment with antifibrotics following Ahmed glaucoma valve implantation decreased the hypertensive phase and improved surgical outcomes without impacting complication rates at 1 year. This study postulates a role for antifibrotics in the postoperative management of Ahmed glaucoma valves.


Assuntos
Fluoruracila/administração & dosagem , Implantes para Drenagem de Glaucoma , Glaucoma/cirurgia , Pressão Intraocular/fisiologia , Mitomicina/administração & dosagem , Complicações Pós-Operatórias/prevenção & controle , Administração Tópica , Idoso , Antibióticos Antineoplásicos/administração & dosagem , Relação Dose-Resposta a Droga , Quimioterapia Combinada , Seguimentos , Humanos , Imunossupressores/administração & dosagem , Injeções , Período Intraoperatório , Masculino , Período Pós-Operatório , Estudos Retrospectivos , Resultado do Tratamento
17.
J Glaucoma ; 26(2): 87-92, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28002187

RESUMO

PURPOSE OF THE STUDY: The purpose of the study was to examine reoperation rate and complications of resident-performed glaucoma surgeries within the first 90 postoperative days. MATERIALS AND METHODS: A retrospective study of resident-performed glaucoma filtering surgeries at the San Francisco Veterans Affairs Medical Center between 2002 and 2014 was performed. Patients requiring reoperation within 90 days of the initial surgery were included in our study. Combined surgeries were excluded. Complications and the rates of reoperation within the first 90 days were evaluated. Clinical outcomes for those who needed reoperations were evaluated at the 1-year follow-up. RESULTS: Total of 180 cases were reviewed [34 trabeculectomy, 85 Ex-PRESS shunt, and 61 Ahmed glaucoma valve (AGV)]. One hundred and four eyes developed complications, most commonly choroidal effusion (65.3%), followed by hypotony (45.2%) and wound leak (32.7%). Complications were comparable among the 3 groups, except that filtering surgery had significantly more wound leak than AGV (P<0.001). Seven (3.9%) cases required reoperation within first 90 days. There was no reoperation for trabeculectomy group. Reoperation rate was 4.7% for Ex-PRESS and 4.9% for AGV (P=0.74). Indications for reoperation were persistent wound leak (4 cases) and tube occlusion/revision (3 cases). For the 7 patients who required reoperations, their intraocular pressure at 1-year postreoperation was significantly decreased compared with intraocular pressure before the initial glaucoma surgery (P<0.001) with similar number of glaucoma medications and stable visual acuity. CONCLUSIONS: Glaucoma incisional surgeries performed by third-year ophthalmology residents had acceptable and comparable reoperation rates and complication rates for patients with trabeculectomy, Ex-PRESS, and AGV. Clinical outcomes for the patients requiring reoperation were favorable.


Assuntos
Competência Clínica/normas , Glaucoma/cirurgia , Internato e Residência , Complicações Intraoperatórias , Oftalmologia/educação , Complicações Pós-Operatórias , Reoperação/estatística & dados numéricos , Adulto , Idoso , Educação de Pós-Graduação em Medicina/normas , Feminino , Glaucoma/fisiopatologia , Implantes para Drenagem de Glaucoma , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tonometria Ocular , Trabeculectomia , Resultado do Tratamento , Acuidade Visual/fisiologia
18.
Eye Contact Lens ; 42(4): 221-4, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26222096

RESUMO

The etiology of corneal decompensation after aqueous shunt implantation remains poorly understood. With the use of anterior segment optical coherence tomography and specular microscopy, the relationship of these implants to the surrounding tissues can be investigated over time. This article will review the current knowledge pertaining to endothelial cell loss related to glaucoma and surgery and highlight possible causes that have been proposed for endothelial cell loss after aqueous shunt implantation.


Assuntos
Endotélio Corneano/fisiopatologia , Endotélio Corneano/cirurgia , Implantes para Drenagem de Glaucoma/efeitos adversos , Glaucoma/cirurgia , Inflamação/etiologia , Humor Aquoso/fisiologia , Doenças da Córnea/etiologia , Doenças da Córnea/patologia , Células Endoteliais/patologia , Células Endoteliais/fisiologia , Endotélio Corneano/diagnóstico por imagem , Endotélio Corneano/patologia , Fibrose/prevenção & controle , Fibrose/terapia , Humanos , Tomografia de Coerência Óptica , Trabeculectomia/efeitos adversos
19.
J Glaucoma ; 25(3): e157-61, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25651207

RESUMO

PURPOSE: To compare intraocular pressure (IOP) reduction and complications of resident-performed argon laser trabeculoplasty (ALT) and selective laser trabeculoplasty (SLT). PATIENTS AND METHODS: This was a retrospective, interventional, comparative case series performed at the San Francisco Veterans Affairs Hospital. The study included 77 patients each undergoing 1 resident-performed ALT procedure from April 2006 through November 2009, and 81 patients each undergoing 1 resident-performed SLT procedure from November 2009 through December 2011. Reduction in IOP at 12 months and a longitudinal analysis across 24 months was determined. Secondary outcomes investigated included additional interventions of either repeat trabeculoplasty or trabeculectomy as well as change in eye drop medications. RESULTS: There was no evidence of a difference between IOP reductions in patients undergoing ALT compared with SLT at 12 months (P=0.41, linear modeling) or across all follow-up appointments (P=0.62, linear-mixed effects regression). Patients undergoing ALT had a significantly increased number of eye drops (+0.6 vs. -0.1 drops, P<0.001, Wilcoxon rank-sum test) and trend toward increased rates of additional interventions (P=0.06, Weibull regression). There was no difference in immediate postprocedure IOP rise between the 2 groups (P=0.75, Wilcoxon rank-sum test) or any evidence of change in visual acuity. CONCLUSIONS: We found no difference in IOP reduction between patients undergoing resident-performed ALT compared with SLT. However, patients undergoing ALT had a significant increase in eye drop medications and trend toward additional interventions compared with patients undergoing SLT.


Assuntos
Educação de Pós-Graduação em Medicina/normas , Glaucoma de Ângulo Aberto/cirurgia , Internato e Residência , Terapia a Laser/métodos , Lasers de Gás/uso terapêutico , Oftalmologia/educação , Trabeculectomia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Anti-Hipertensivos/administração & dosagem , Competência Clínica , Feminino , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Complicações Intraoperatórias , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Reoperação , Estudos Retrospectivos , Malha Trabecular/cirurgia , Trabeculectomia/educação , Resultado do Tratamento , Acuidade Visual/fisiologia
20.
Cornea ; 34(1): 37-41, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25393097

RESUMO

PURPOSE: The aim of this study was to assess the effect of various tube parameters on corneal endothelial cell density (ECD) after insertion of Ahmed valves. METHODS: Thirty-nine eyes of 33 patients with previous superotemporal (ST) Ahmed valve implantation and 20 eyes of 13 participants with previous uncomplicated phacoemulsification and intraocular lens implantation but no history of glaucoma surgery were evaluated. Various tube parameters were measured with anterior segment optical coherence tomography. ST, central, and inferonasal (IN) ECD and pachymetry were measured. Endothelial cell loss and corneal thickness in the ST cornea was compared with those in the IN cornea. RESULTS: The mean age of the operated patients was 58 ± 22 years, and the mean time since glaucoma surgery was 2.5 ± 2.6 years. Thirty-two of the 39 study eyes were pseudophakic. The ECD was significantly lower in the ST endothelium than in the IN endothelium in eyes with glaucoma tube surgery (P < 0.001), although this relative reduction in ST ECD was not greater than that seen in pseudophakic control eyes (P = 0.16). In univariate analysis, tube angle relative to the cornea and distance from the tip of the tube to the cornea were significant risk factors for decreased ST endothelial cell loss when assessed relative to the IN ECD (P = 0.01 and P = 0.02, respectively). In multivariate analysis, only the distance of the tube tip to the cornea remained significantly associated with ST endothelial cell loss. CONCLUSIONS: Although this was a retrospective study with inherent limitations, tubes that are closer to the cornea seem to lead to increased loss of adjacent endothelial cells.


Assuntos
Perda de Células Endoteliais da Córnea/etiologia , Endotélio Corneano/patologia , Implantes para Drenagem de Glaucoma/efeitos adversos , Glaucoma/cirurgia , Adulto , Idoso , Contagem de Células , Perda de Células Endoteliais da Córnea/diagnóstico , Paquimetria Corneana , Feminino , Humanos , Pressão Intraocular , Implante de Lente Intraocular , Masculino , Pessoa de Meia-Idade , Facoemulsificação , Estudos Retrospectivos , Tomografia de Coerência Óptica