Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
NPJ Microgravity ; 10(1): 74, 2024 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-38969640

RESUMO

Cold atmospheric pressure plasma (ionized gas) is an innovative medical tool for the treatment of infected wounds thanks to its potential to inactivate drug-resistant microorganisms and promote tissue regeneration and vascularization. The low power consumption, compactness, and versatility of Cold Atmospheric Pressure Plasma (CAPP) devices make them an ideal tool for risk mitigation associated with human spaceflights. This work presents results in microgravity on the operability of CAPP and its antimicrobial effect. The experiments carried out in parabolic flights make it possible to optimize the treatment conditions (i.e., the distance, the gas mixture) and to obtain the rapid inactivation (<15 s) of Escherichia coli samples. Interestingly, the inactivation efficiency of CAPP was higher during parabolic flights than under terrestrial conditions. Overall, these results encourage the further development of CAPP medical devices for its implementation during human spaceflights.

2.
Int J Cosmet Sci ; 30(1): 57-65, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18377631

RESUMO

The effects of different emulsifiers on the in vitro permeation through human skin of two sunscreen agents [octylmethoxycinnamate (OMC) and butylmethoxydibenzoylmethane (BMBM)] were investigated from O/W emulsions. The test formulations were prepared using the same oil and aqueous phase ingredients and the following emulsifier and coemulsifier systems: Emulgade SE((R)) (ceteareth-12 and ceteareth-20 and cetearyl alcohol and cetyl palmitate) and glycerylmonostearate (emulsion 1); Brij 72((R)) (steareth-2), Brij 721((R)) (steareth-21) and cetearyl alcohol (emulsion 2); Phytocream((R)) (potassium palmitoyl-hydrolysed wheat protein and glyceryl stearate and cetearyl alcohol) and glycerylmonostearate (emulsion 3); Montanov 68((R)) (cetearyl glucoside and cetearyl alcohol) (emulsion 4); Xalifin-15((R)) (C(15-20) acid PEG-8 ester) and cetearyl alcohol (emulsion 5). The cumulative amount of OMC that permeated in vitro through human skin after 22 h from the formulations being tested decreased in the order 3 > 1 congruent with 4 > 5 > 2 and was about nine-fold higher from emulsion 3 compared with that from emulsion 2. As regards BMBM, no significant difference was observed as regards its skin permeation from emulsions 1, 3, 4 and 5, whereas formulation 2 allowed significantly lower amounts of BMBM to permeate the skin. In vitro release experiments of OMC and BMBM from emulsions 1-6 through cellulose acetate membranes showed that only emulsions 4 and 5 provided pseudo-first-order release rates only for OMC. The results of this study suggest that the type of emulsifying systems used to prepare an O/W emulsion may strongly affect sunscreen skin permeation from these formulations. Therefore, the vehicle effects should be carefully considered in the formulation of sunscreen products.


Assuntos
Emulsões/farmacologia , Pele/metabolismo , Protetores Solares/farmacocinética , Tensoativos/farmacologia , Administração Tópica , Adulto , Cromatografia Líquida de Alta Pressão , Cosméticos/administração & dosagem , Cosméticos/farmacocinética , Emulsões/administração & dosagem , Feminino , Humanos , Técnicas In Vitro , Pele/efeitos dos fármacos , Absorção Cutânea , Protetores Solares/administração & dosagem , Tensoativos/administração & dosagem
3.
J Drug Target ; 15(9): 603-10, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17968714

RESUMO

Chitosan (CH) was used as a biocompatible and bioadhesive polymer material to prepare solid dispersions as well as hydrogels loaded with dexamethasone sodium phosphate (DSP), a steroidal anti-inflammatory agent clinically used for treatment of different mouth diseases. Binary solid dispersions at various drug-to-polymer weight ratios were prepared by freeze-drying; their direct compression gave tablets which were characterized for the swelling behaviour and drug release in vitro. Similarly, DSP-loaded hydrogels composed of CH and glycerine were prepared and characterized. CH and DSP showed a good physical compatibility. A slow and prolonged release of the drug was observed in vitro from both kinds of systems. The swelling properties of the polymer seemed to be the main parameter affecting the drug release profile from both tablets and hydrogels at the pH value of mouth. In vivo buccal application of both the systems allowed to obtain a prolonged release of DSP, as compared with a glycerine solution of the drug. From the in vitro swelling studies and in vivo test, the 2:1 CH-DSP solid dispersion in particular can be designated for further investigation.


Assuntos
Quitosana/química , Dexametasona/análogos & derivados , Sistemas de Liberação de Medicamentos , Mucosa Bucal , Varredura Diferencial de Calorimetria , Dexametasona/administração & dosagem , Humanos , Hidrogéis
4.
J Biomech Eng ; 119(2): 206-12, 1997 May.
Artigo em Inglês | MEDLINE | ID: mdl-9168397

RESUMO

We investigated the changes of flow patterns in a blood vessel with a side wall aneurysm resulting from placement of a stent. Local hemodynamics can be markedly altered by placing an intravascular stent, which covers the orifice of the aneurysm. The alternations in flow patterns can lead to flow stasis in the aneurysmal pouch and promote the formation of a stable thrombus. Furthermore, a porous stent can serve as substrate for neointimal growth and subsequently induce a remodeling of the diseased arterial segment. To examine changes in local hemodynamics due to stent placement, a stented and nonstented aneurysm model was investigated computationally in a three-dimensional configuration using a finite element fluid dynamics program. The finite element model was studied under incompressible, pulsatile, viscous, Newtonian conditions. The fluid dynamic similarity parameter, i.e., the maximum/minimum Reynolds number, was set at about 240/25 based on cross-sectional average instantaneous flow. The Womersley number was set to 2.5. These values are representative of large cerebral arteries. The results of the stented versus the nonstented model show substantial difference sin flow patterns inside the aneurysmal pouch. Flow activity inside the stented aneurysm model is significantly diminished and flow inside the parent vessel is less undulated and is directed past the orifice. A high-pressure zone at the distal neck and the dome of the aneurysm prior to stenting decreases after stent placement. However, elevated pressure values are found at the stent filaments facing the current. Higher shear rates are observed at the distal aneurysmal neck after stenting, but are confined to a smaller region and are unidirectional compared to the nonstented model.


Assuntos
Aneurisma/fisiopatologia , Aneurisma/cirurgia , Hemorreologia , Modelos Cardiovasculares , Análise Numérica Assistida por Computador , Stents , Velocidade do Fluxo Sanguíneo , Viscosidade Sanguínea , Humanos , Fluxo Pulsátil , Reprodutibilidade dos Testes , Trombose/etiologia
5.
Ann Biomed Eng ; 25(3): 460-9, 1997.
Artigo em Inglês | MEDLINE | ID: mdl-9146801

RESUMO

Recent developments in minimally invasive approach to cerebrovascular diseases include the placement of stents in arteries for treatment of aneurysms. Preliminary clinical observations and experimental studies have shown that intravascular stents traversing the orifice may lead to thrombosis and subsequent occlusion of the aneurysm. The alterations in vessel local hemodynamics due to the introduction of a stent are not yet well understood. We investigated changes in local hemodynamics resulting from stent implantation. Pulsatile flow patterns in an experimental flow apparatus were visualized using laser-induced fluorescence of rhodamine dye. The test cells were constructed in a rectangular shape to facilitate an undisturbed longitudinal view of flow patterns in parent vessel and aneurysm models with and without porous stents. Woven nitinol stents of various porosities (76%, 80%, 82%, and 85%) were investigated. The selected fluid dynamic similarity parameters (Reynolds and Womersley numbers) represented conditions usually found in high-flow, larger arteries in humans (such as the carotid artery) and low-flow, smaller arteries (such as the vertebral artery). The mean Reynolds number for the larger arteries was 180, with maximum/minimum values of 490/-30 and the Womersley number was 5.3. The mean Reynolds number for the smaller arteries was 90, with maximum/minimum values of 230/2, and the Womersley number was 2.7. For the larger arteries modeled, placement of a stent of the lowest porosity across the aneurysm orifice resulted in reduction of aneurysmal vortex speed and decreased interaction with parent vessel flow. For smaller arteries, a stent of the same porosity led to a substantial reduction of parent vessel/aneurysmal flow interaction and the appearance of a nonrecirculating crescent of fluid rich in rhodamine dye in the aneurysm dome. Our results can help explain in vivo thrombus formation within an aneurysm after placement of a stent that is compatible with local hemodynamics.


Assuntos
Hemodinâmica/fisiologia , Aneurisma Intracraniano/terapia , Modelos Biológicos , Stents , Corantes Fluorescentes , Humanos , Aneurisma Intracraniano/fisiopatologia , Lasers , Porosidade , Reologia/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...