Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Thorac Surg ; 93(2): 465-72, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22206951

RESUMO

BACKGROUND: This article investigates patient radiation doses during implantation of thoracic stent-graft. Aortic stengraft implantation can be disturbed by many factors, which, in turn, lead to prolongation of the procedure time and, as a consequence, increase the radiation dose. METHODS: Measurements of radiation length (fluoroscopy and exposure), air kerma (AK) in grays, and dose-area product in grays·square centimeters were conducted simultaneously in 100 patients. The patients were analyzed retrospectively, regarding their body mass index (BMI), type of aneurysms, number of stent-graft parts, angulation of aorta, and coverage of the left subclavian artery. RESULTS: Mean total dose-area product value for this kind of treatment was 361 Gy·cm2. This was caused by the fact that total mean AK was high for the cohort analyzed and reached 797 mGy. For 23 patients total AK was between 1 and 2 Gy, and for 3 it exceeded 2 Gy. In the remaining group, the maximal radiation dose was very high and exceeded 3 Gy. The total AK of patients with BMI within the range of 25 to 29.9 kg/m2 and with BMI greater than 30 kg/m2 significantly increased in comparison with the group of patients with BMI between 18 and 24.9 kg/m2 (p=0.00005 and 0.000001, respectively). During the study, a good correlation between AK and fluoroscopy time (r=0.6) and for AK (or dose-area product) and exposure time (r=0.66 or 0.81, respectively) was observed. CONCLUSIONS: The main factors contributing to a high radiation dose being acquired by patients during thoracic stent-graft were BMI greater than 25 kg/m2, number of parts of the stent-graft, and angulation of the neck of aneurysm exceeding 60 degrees.


Assuntos
Implante de Prótese Vascular , Procedimentos Endovasculares , Fluoroscopia/efeitos adversos , Doses de Radiação , Lesões por Radiação/etiologia , Radiografia Intervencionista/efeitos adversos , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/cirurgia , Aorta/lesões , Aneurisma Aórtico/cirurgia , Doenças da Aorta/cirurgia , Aterosclerose/cirurgia , Índice de Massa Corporal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Lesões por Radiação/epidemiologia , Lesões por Radiação/prevenção & controle , Radiometria , Fatores de Tempo , Úlcera/cirurgia , Adulto Jovem
2.
Med Sci Monit ; 17(11): MT97-103, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22037751

RESUMO

BACKGROUND: An important negative factor of EVAR is the radiation acquired during long-lasting procedures. The aim of the study was to document the radiation doses of EVAR and to discuss potential reasons for prolongation of radiological procedures. MATERIAL/METHODS: Dose-area product (DAP) (Gy cm²) and air kerma (AK) (Gy) obtained during EVAR from 92 patients were analyzed retrospectively in regards to body mass index (BMI), angulations of aneurysm neck, length of aneurysm neck and occurrence of tortuosity of iliac arteries. RESULTS: Total AK for fluoroscopy differed significantly between normal BMI (373 mGy) and BMI 25-29.9 (1125 mGy) or BMI >30 (1085 mGy). Iliac artery tortuosities >45° and short aneurysm necks caused higher doses of total AK (1097 mGy and 1228 mGy, respectively) than iliac artery tortuosities <45° and long aneurysm necks (605 mGy and 720 mGy, respectively). CONCLUSIONS: The main factors contributing to a high radiation dose being acquired by patients during EVAR are: BMI >25, tortuosity of iliac arteries >45° and short aneurysm necks.


Assuntos
Angiografia Digital/efeitos adversos , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/métodos , Fluoroscopia/efeitos adversos , Doses de Radiação , Radiografia Intervencionista/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estatísticas não Paramétricas , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...