Brachytherapy ; 13(6): 640-50, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24929641

RESUMO

PURPOSE: The accurate delivery of high-dose-rate brachytherapy is dependent on the correct identification of the position and shape of the treatment catheters. In many brachytherapy clinics, transrectal ultrasound (TRUS) imaging is used to identify the catheters. However, manual catheter identification on TRUS images can be time consuming, subjective, and operator dependent because of calcifications and distal shadowing artifacts. We report the use of electromagnetic (EM) tracking technology to map the position and shape of catheters inserted in a tissue-mimicking phantom. METHODS AND MATERIALS: The accuracy of the EM system was comprehensively quantified using a three-axis robotic system. In addition, EM tracks acquired from catheters in a phantom were compared with catheter positions determined from TRUS and CT images to compare EM system performance to standard clinical imaging modalities. The tracking experiments were performed in a controlled laboratory environment and also in a typical brachytherapy operating room to test for potential EM distortions. RESULTS: The robotic validation of the EM system yielded a mean accuracy of <0.5 mm for a clinically acceptable field of view in a nondistorting environment. The EM-tracked catheter representations were found to have an accuracy of <1 mm when compared with TRUS- and CT-identified positions, both in the laboratory environment and in the brachytherapy operating room. The achievable accuracy depends to a large extent on the calibration of the TRUS probe, geometry of the tracked devices relative to the EM field generator, and locations of surrounding clinical equipment. To address the issue of variable accuracy, a robust calibration algorithm has been developed and integrated into the workflow. The proposed mapping technique was also found to improve the workflow efficiency of catheter identification. CONCLUSIONS: The high baseline accuracy of the EM system, the consistent agreement between EM-tracked, TRUS- and CT-identified catheters, and the improved workflow efficiency illustrate the potential value of using EM tracking for catheter mapping in high-dose-rate brachytherapy.


Assuntos
Braquiterapia/métodos , Catéteres , Processamento de Imagem Assistida por Computador , Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Radioterapia Guiada por Imagem/métodos , Algoritmos , Calibragem , Fenômenos Eletromagnéticos , Humanos , Masculino , Imagens de Fantasmas , Dosagem Radioterapêutica , Robótica , Ultrassonografia
2.
Int J Comput Assist Radiol Surg ; 6(3): 407-19, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-20714934

RESUMO

PURPOSE: Electromagnetic (EM)-guided endoscopy has demonstrated its value in minimally invasive interventions. Accuracy evaluation of the system is of paramount importance to clinical applications. Previously, a number of researchers have reported the results of calibrating the EM-guided endoscope; however, the accumulated errors of an integrated system, which ultimately reflect intra-operative performance, have not been characterized. To fill this vacancy, we propose a novel system to perform this evaluation and use a 3D metric to reflect the intra-operative procedural accuracy. METHODS: This paper first presents a portable design and a method for calibration of an electromagnetic (EM)-tracked endoscopy system. An evaluation scheme is then described that uses the calibration results and EM-CT registration to enable real-time data fusion between CT and endoscopic video images. We present quantitative evaluation results for estimating the accuracy of this system using eight internal fiducials as the targets on an anatomical phantom: the error is obtained by comparing the positions of these targets in the CT space, EM space and endoscopy image space. To obtain 3D error estimation, the 3D locations of the targets in the endoscopy image space are reconstructed from stereo views of the EM-tracked monocular endoscope. Thus, the accumulated errors are evaluated in a controlled environment, where the ground truth information is present and systematic performance (including the calibration error) can be assessed. RESULTS: We obtain the mean in-plane error to be on the order of 2 pixels. To evaluate the data integration performance for virtual navigation, target video-CT registration error (TRE) is measured as the 3D Euclidean distance between the 3D-reconstructed targets of endoscopy video images and the targets identified in CT. The 3D error (TRE) encapsulates EM-CT registration error, EM-tracking error, fiducial localization error, and optical-EM calibration error. CONCLUSION: We present in this paper our calibration method and a virtual navigation evaluation system for quantifying the overall errors of the intra-operative data integration. We believe this phantom not only offers us good insights to understand the systematic errors encountered in all phases of an EM-tracked endoscopy procedure but also can provide quality control of laboratory experiments for endoscopic procedures before the experiments are transferred from the laboratory to human subjects.


Assuntos
Broncoscopia/métodos , Imageamento Tridimensional/instrumentação , Tomografia Computadorizada por Raios X , Algoritmos , Calibragem , Fenômenos Eletromagnéticos , Desenho de Equipamento , Humanos , Processamento de Imagem Assistida por Computador , Modelos Anatômicos , Imagens de Fantasmas , Interface Usuário-Computador , Gravação em Vídeo