Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Magn Reson ; 287: 33-40, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29278827

RESUMO

An NMR Q-switch was designed and constructed specifically for use with low-field NMR apparatus. This featured a comparatively simple resistive damping design. It served to reduce the r.f. probe ring-down time, and hence reduced the signal acquisition delay from 25 ms to 9 ms, on an Earth's magnetic field NMR system. The advantage of this earlier acquisition was demonstrated for both an aqueous suspension of iron oxide particles and using an NMR flow meter.

2.
Nature ; 455(7213): 644-7, 2008 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-18833275

RESUMO

Detection of weak magnetic fields with nanoscale spatial resolution is an outstanding problem in the biological and physical sciences. For example, at a distance of 10 nm, the spin of a single electron produces a magnetic field of about 1 muT, and the corresponding field from a single proton is a few nanoteslas. A sensor able to detect such magnetic fields with nanometre spatial resolution would enable powerful applications, ranging from the detection of magnetic resonance signals from individual electron or nuclear spins in complex biological molecules to readout of classical or quantum bits of information encoded in an electron or nuclear spin memory. Here we experimentally demonstrate an approach to such nanoscale magnetic sensing, using coherent manipulation of an individual electronic spin qubit associated with a nitrogen-vacancy impurity in diamond at room temperature. Using an ultra-pure diamond sample, we achieve detection of 3 nT magnetic fields at kilohertz frequencies after 100 s of averaging. In addition, we demonstrate a sensitivity of 0.5 muT Hz(-1/2) for a diamond nanocrystal with a diameter of 30 nm.

3.
Rev Sci Instrum ; 79(5): 051301, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18513054

RESUMO

We review the techniques used in the design and construction of cryogenic sapphire oscillators at the University of Western Australia over the 18 year history of the project. We describe the project from its beginnings when sapphire oscillators were first developed as low-noise transducers for gravitational wave detection. Specifically, we describe the techniques that were applied to the construction of an interrogation oscillator for the PHARAO Cs atomic clock in CNES, in Toulouse France, and to the 2006 construction of four high performance oscillators for use at NMIJ and NICT, in Japan, as well as a permanent secondary frequency standard for the laboratory at UWA. Fractional-frequency fluctuations below 6 x 10(-16) at integration times between 10 and 200 s have been repeatedly achieved.

4.
Opt Express ; 14(10): 4316-27, 2006 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-19516584

RESUMO

We demonstrate an optical frequency comb with fractional frequency instability of

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...