1.
Transl Vis Sci Technol ; 10(12): 10, 2021 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-34614166

RESUMO

Purpose: Clinically evaluate the noninferiority of a custom virtual reality (VR) perimetry system when compared to a clinically and routinely used perimeter on both healthy subjects and glaucoma patients. Methods: We use a custom-designed VR perimetry system tailored for visual field testing. The system uses Oculus Quest VR headset (Facebook Technologies, LLC, Bern, Switzerland), that includes a clicker for participant response feedback. A prospective, single center, study was conducted at the Department of Ophthalmology of the Bern University Hospital (Bern, Switzerland) for 12 months. Of the 114 participants recruited 70 subjects (36 healthy and 34 glaucoma patients with early to moderate visual field loss) were included in the study. Participants underwent perimetry tests on an Octopus 900 (Haag-Streit, Köniz, Switzerland) as well as on the custom VR perimeter. In both cases, standard dynamic strategy (DS) was used in conjunction with the G testing pattern. Collected visual fields (VFs) from both devices were then analyzed and compared. Results: High mean defect (MD) correlations between the two systems (Spearman, ρ ≥ 0.75) were obtained. The VR system was found to slightly underestimate VF defects in glaucoma subjects (1.4 dB). No significant bias was found with respect to eccentricity or subject age. On average, a similar number of stimuli presentations per VF was necessary when measuring glaucoma patients and healthy subjects. Conclusions: This study demonstrates that a clinically used perimeter and the proposed VR perimetry system have comparable performances with respect to a number of perimetry parameters in healthy and glaucoma patients with early to moderate visual field loss. Translational Relevance: This suggests that VR perimeters have the potential to assess VFs with high enough confidence, whereby alleviating challenges in current perimetry practices by providing a portable and more accessible visual field test.


Assuntos
Glaucoma , Realidade Virtual , Glaucoma/diagnóstico , Humanos , Estudos Prospectivos , Testes de Campo Visual , Campos Visuais
2.
Transl Vis Sci Technol ; 9(13): 3, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33344047

RESUMO

Purpose: To clinically validate the noninferiority of the sequentially optimized reconstruction strategy (SORS) when compared to the dynamic strategy (DS). Methods: SORS is a novel perimetry testing strategy that evaluates a subset of test locations of a visual field (VF) test pattern and estimates the untested locations by linear approximation. When testing fewer locations, SORS has been shown in computer simulations to bring improvements in speed over conventional perimetry tests, while maintaining acquisition at high-quality acquisition. To validate SORS, a prospective clinical study was conducted at the Department of Ophthalmology of Bern University Hospital, over 12 months. Eighty-three subjects (32 healthy and 51 glaucoma patients with early to moderate visual field loss) of 114 participants were included in the study. The subjects underwent perimetry tests on an Octopus 900 (Haag-Streit, Köniz, Switzerland) using the G pattern with both DS and SORS. The acquired sensitivity thresholds (ST) by both tests were analyzed and compared. Results: DS-acquired VFs were used as a reference. High correlations between individual STs (r ≥ 0.74), as well as between mean defect values (r ≥ 0.88) given by DS and SORS were obtained. The mean absolute error of SORS was under 3 dB with a 70% reduction in acquisition time. SORS overestimated healthy VFs while slightly underestimating glaucomatous VFs. Qualitatively, SORS acquisition yielded VF with detectable defect patterns, albeit some isolated and small defects were occasionally missed. Conclusions: This clinical study showed that for healthy and glaucomatous patients, SORS-acquired VFs sufficiently correlated with the DS-acquired VFs with up to 70% reduction in acquisition time. Translational Relevance: This clinical study suggests that the novel perimetry strategy SORS could be used in routine clinical practice with comparable utility to the current standard DS, whereby providing a shorter and more comfortable perimetry experience.


Assuntos
Glaucoma , Testes de Campo Visual , Glaucoma/diagnóstico , Voluntários Saudáveis , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes , Suíça , Campos Visuais