Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Med Phys ; 35(10): 4649-59, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18975711

RESUMO

Cone-beam computed tomography (CBCT) using an "on-board" x-ray imaging device integrated into a radiation therapy system has recently been made available for patient positioning, target localization, and adaptive treatment planning. One of the challenges for gantry mounted image-guided radiation therapy (IGRT) systems is the slow acquisition of projections for cone-beam CT (CBCT), which makes them sensitive to any patient motion during the scans. Aiming at motion artifact reduction, four-dimensional CBCT (4D CBCT) techniques have been introduced, where a surrogate for the target's motion profile is utilized to sort the cone-beam data by respiratory phase. However, due to the limited gantry rotation speed and limited readout speed of the on-board imager, fewer than 100 projections are available for the image reconstruction at each respiratory phase. Thus, severe undersampling streaking artifacts plague 4D CBCT images. In this paper, the authors propose a simple scheme to significantly reduce the streaking artifacts. In this method, a prior image is first reconstructed using all available projections without gating, in which static structures are well reconstructed while moving objects are blurred. The undersampling streaking artifacts from static structures are estimated from this prior image volume and then can be removed from the phase images using gated reconstruction. The proposed method was validated using numerical simulations, experimental phantom data, and patient data. The fidelity of stationary and moving objects is maintained, while large gains in streak artifact reduction are observed. Using this technique one can reconstruct 4D CBCT datasets using no more projections than are acquired in a 60 s scan. At the same time, a temporal gating window as narrow as 100 ms was utilized. Compared to the conventional 4D CBCT reconstruction, streaking artifacts were reduced by 60% to 70%.


Assuntos
Algoritmos , Artefatos , Tomografia Computadorizada de Feixe Cônico/métodos , Imageamento Tridimensional/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Mecânica Respiratória , Humanos , Movimento (Física) , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...