1.
Heart Rhythm ; 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38825299

RESUMO

BACKGROUND: Obesity confers higher risks of cardiac arrhythmias. The extent to which weight loss reverses subclinical proarrhythmic adaptations in arrhythmia-free obese individuals is unknown. OBJECTIVE: The purpose of this study was to study structural, electrophysiological, and autonomic remodeling in arrhythmia-free obese patients and their reversibility with bariatric surgery using electrocardiographic imaging (ECGi). METHODS: Sixteen arrhythmia-free obese patients (mean age 43 ± 12 years; 13 females; BMI 46.7 ± 5.5 kg/m2) had ECGi pre-bariatric surgery, of whom 12 had ECGi postsurgery (BMI 36.8 ± 6.5 kg/m2). Sixteen age- and sex-matched lean healthy individuals (mean age 42 ± 11 years; BMI 22.8 ± 2.6 kg/m2) acted as controls and had ECGi only once. RESULTS: Obesity was associated with structural (increased epicardial fat volumes and left ventricular mass), autonomic (blunted heart rate variability), and electrophysiological (slower atrial conduction and steeper ventricular repolarization gradients) remodeling. After bariatric surgery, there was partial structural reverse remodeling, with a reduction in epicardial fat volumes (68.7 cm3 vs 64.5 cm3; P = .0010) and left ventricular mass (33 g/m2.7 vs 25 g/m2.7; P < .0005). There was also partial electrophysiological reverse remodeling with a reduction in mean spatial ventricular repolarization gradients (26 mm/ms vs 19 mm/ms; P = .0009), although atrial activation remained prolonged. Heart rate variability, quantified by standard deviation of successive differences in R-R intervals, was also partially improved after bariatric surgery (18.7 ms vs 25.9 ms; P = .017). Computational modeling showed that presurgery obese hearts had a larger window of vulnerability to unidirectional block and had an earlier spiral-wave breakup with more complex reentry patterns than did postsurgery counterparts. CONCLUSION: Obesity is associated with adverse electrophysiological, structural, and autonomic remodeling that is partially reversed after bariatric surgery. These data have important implications for bariatric surgery weight thresholds and weight loss strategies.

2.
Magn Reson Med ; 87(3): 1446-1460, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34752644

RESUMO

PURPOSE: Before MR fingerprinting (MRF) can be adopted clinically, the derived quantitative values must be proven accurate and repeatable over a range of T1 and T2 values and temperatures. Correct assessment of accuracy and precision as well as comparison between measurements can only be performed when temperature is either controlled or corrected for. The purpose of this study was to investigate the temperature dependence of T1 and T2 MRF values and evaluate the accuracy and repeatability of temperature-corrected relaxation values derived from a B1 -corrected MRF-fast imaging with steady-state precession implementation using 2 different dictionary sizes. METHODS: The International Society of MR in Medicine/National Institute of Standards and Technology phantom was scanned using an MRF sequence of 2 different lengths, a variable flip angle T1 , and a multi-echo spin echo T2 at 14 temperatures ranging from 15°C to 28°C and investigated with a linear regression model. Temperature-corrected accuracy was evaluated by correlating T1 and T2 times from each MRF dictionary with reference values. Repeatability was assessed using the coefficient of variation, with measurements taken over 30 separate sessions. RESULTS: There was a statistically significant fit of the model for MRF-derived T1 and T2 and temperature (p < 0.05) for all the spheres with a T1 > 500 ms. Both MRF methods showed a strong linear correlation with reference values for T1 (R2 = 0.996) and T2 (R2 = 0.982). MRF repeatability for T1 values was ≤1.4% and for T2 values was ≤3.4%. CONCLUSION: MRF demonstrated relaxation times with a temperature dependence similar to that of conventional mapping methods. Temperature-corrected T1 and T2 values from both dictionaries showed adequate accuracy and excellent repeatability in this phantom study.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Valores de Referência , Reprodutibilidade dos Testes , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...