Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
3.
Eur Radiol ; 16(11): 2512-20, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16670866

RESUMO

The objective of this study was to evaluate the accuracy of electrocardiography (ECG)-gated 16-slice multidetector-row computed tomography (MDCT) in detection of stenosis of bypass grafts and native coronary arteries in patients who have undergone coronary artery bypass grafting (CABG). ECG-gated contrast-enhanced MDCT using 12 x 0.75-mm collimation was performed in 20 patients with recurrent angina 4.75 years after undergoing CABG. A total of 50 grafts, 16 arterial and 34 venous, were examined. All graft and coronary segments were evaluated for stenosis in comparison with conventional coronary angiography (CCA). Among the 80 arterial graft segments, 62 could be assessed (77.5%). Sensitivity, specificity, and positive and negative predictive values for stenosis were 96.2%, 97.2%, 96.2%, and 97.2%, respectively. In a total of 180 venous graft segments, 167 could be assessed. Sensitivity, specificity, and positive and negative predictive values for stenosis were 98.5%, 93.9%, 91.8%, and 98.9%, respectively. MDCT could assess 179 of 260 native coronary artery segments (68.8%). Sensitivity, specificity, and positive and negative predictive values for stenosis were 92.1%, 76.9%, 87.5%, and 84.7%, respectively. Sixteen-slice MDCT provides excellent image quality and diagnostic accuracy in detection of graft and coronary artery lesions in patients with suspected graft dysfunction.


Assuntos
Angiografia Coronária , Ponte de Artéria Coronária , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/fisiopatologia , Tomografia Computadorizada por Raios X , Grau de Desobstrução Vascular , Angina Pectoris/diagnóstico por imagem , Angina Pectoris/fisiopatologia , Angina Pectoris/cirurgia , Calcinose/diagnóstico por imagem , Calcinose/etiologia , Calcinose/fisiopatologia , Meios de Contraste , Reestenose Coronária/etiologia , Eletrocardiografia , Alemanha , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Frequência Cardíaca , Humanos , Projetos de Pesquisa , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/instrumentação , Resultado do Tratamento
4.
Radiology ; 238(3): 1013-21, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16439565

RESUMO

The purpose of this study was to prospectively evaluate an arterial spin-labeling technique, flow-sensitive alternating inversion-recovery (FAIR) true fast imaging with steady-state precession (FISP), for noninvasive quantification of renal perfusion in patients without a history of renal artery stenosis (RAS) and in patients with proved RAS. The study was approved by the local ethics committee, and all participants provided written informed consent. Six patients with hypertension but no history of renal artery disease and 12 patients with RAS underwent FAIR true FISP magnetic resonance (MR) imaging in a whole-body 1.5-T unit. RAS grade and scintigraphic perfusion data served as the reference standards. On the FAIR true FISP perfusion images, severe RAS (>70% luminal narrowing) could be clearly distinguished from no or mild RAS and moderate RAS (< or =70% luminal narrowing) (P < .005). Significant correlations between FAIR perfusion data and stenosis grade (r = -0.76) and between FAIR and single photon emission computed tomographic perfusion values (r = 0.83) were observed. FAIR true FISP was found to be suitable for quantitative perfusion imaging of the kidneys in patients with RAS.


Assuntos
Rim/irrigação sanguínea , Angiografia por Ressonância Magnética/métodos , Obstrução da Artéria Renal/diagnóstico , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Marcadores de Spin , Estatísticas não Paramétricas
5.
Eur Radiol ; 16(3): 551-9, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16215736

RESUMO

OBJECTIVE: To assess functional parameters using multidetector-row computed tomography (MDCT) and echocardiography and to compare the results with magnetic resonance imaging (MRI). MATERIALS AND METHODS: End-diastolic-volume (EDV), end-systolic-volume (ESV), stroke-volume (SV), ejection-fraction (EF), and myocardial mass (MM) were calculated based on CT data sets from 52 patients. Echocardiography was performed in 24 of the 52 patients. The results from MDCT and echocardiography were compared with MRI. RESULTS: A strong correlation between MDCT and MRI (r=0.66-0.90) was found for all parameters. Echocardiography revealed a low or moderate correlation (0.05-0.59). Compared to MRI the average differences with MDCT were for EDV 15.1 ml, ESV 10.6 ml, SV 4.5 ml, EF 1.8%, and MM 8.2 g, for EDV determined by echocardiography 36.2 ml, ESV 6.8 ml, and EF 13.9%. Bland-Altman analysis revealed acceptable limits of agreement between MRI and MDCT. CONCLUSIONS: MDCT enables reliable quantification of left ventricular function. Echocardiography was found to have only a moderate agreement of functional parameters with MRI.


Assuntos
Disfunção Ventricular Esquerda/diagnóstico , Angiografia Coronária , Ecocardiografia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estatísticas não Paramétricas , Tomografia Computadorizada por Raios X
6.
Radiology ; 238(1): 280-91, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16304083

RESUMO

In this prospective study, the feasibility of a comprehensive cardiovascular imaging protocol with a dedicated whole-body 1.5-T magnetic resonance (MR) imager with 32 receiver channels in 34 patients with peripheral arterial occlusive disease was evaluated. Informed consent and institutional review board approval were obtained. Three-dimensional MR angiographic data sets were acquired with adapted injection protocol. Cardiac functional imaging and delayed-enhancement imaging were performed, as were fluid-attenuated inversion-recovery imaging of the brain and time-of-flight MR angiography of the intracranial blood vessels. Sensitivity and specificity for depiction of significant vascular stenosis (> 70%) were 96%, with conventional digital subtraction angiography as the standard. Substantial microangiopathic tissue alterations (n = 4) and/or cerebral infarction (n = 4) were diagnosed in seven patients. In seven patients, subendocardial or transmural delayed enhancement was detected in corresponding regions, indicating prior myocardial infarction. Previously unknown findings diagnosed with MR imaging required midterm follow-up or therapy in 24 patients, whereas change of therapy or immediate treatment was necessary in three. For patients suspected of having systemic atherosclerotic disease, comprehensive risk assessment is feasible within 30 minutes.


Assuntos
Arteriopatias Oclusivas/diagnóstico , Aterosclerose/diagnóstico , Angiografia por Ressonância Magnética/métodos , Doenças Vasculares Periféricas/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital , Estudos de Viabilidade , Feminino , Humanos , Angiografia por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Medição de Risco , Sensibilidade e Especificidade
7.
AJR Am J Roentgenol ; 185(3): 627-35, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16120910

RESUMO

OBJECTIVE: Providing high temporal and spatial resolution, perfusion MRI is an attractive alternative to traditional radionuclide methods like SPECT and PET. Although first-pass perfusion MRI examinations have gained increasing attention during the past years, this technique still exhibits relatively low signal-to-noise ratio and cardiac coverage. Previous studies have suggested that refocused gradient sequence technology (e.g., true fast imaging with steady-state precession [FISP]) should improve perfusion MRI examinations. The aim of this study was to assess myocardial perfusion deficits in patients with proven coronary artery disease using a saturation recovery true FISP perfusion sequence. SUBJECTS AND METHODS: Rest and stress perfusion MRI studies were performed in 22 patients with coronary artery disease at 1.5 T using a multislice saturation recovery true FISP sequence after the bolus injection of 0.025 mmol/kg of body weight of gadopentetate dimeglumine. The myocardium of each slice was divided into 12 radial segments with subdivision into subendocardial and subepicardial subregions. Myocardial perfusion was assessed semiquantitatively and independently for each subregion. The standard of reference for myocardial perfusion was SPECT. Delayed enhancement images were acquired after the injection of 0.15 mmol/kg of body weight of gadopentetate dimeglumine. RESULTS: Sensitivity and specificity of perfusion MRI examinations for the detection of perfusion deficits were 81% and 89%, respectively, for the semiquantitative perfusion parameter upslope and 78% and 86% for the parameter peak signal intensity. More specifically, rest perfusion examinations were able to detect areas of infarction, whereas stress examinations increased the perfusion differences between normal and ischemic myocardial areas. Excellent correlation was observed between rest perfusion and late enhancement findings (r = 0.90). CONCLUSION: In patients with single-vessel coronary artery disease, perfusion deficits can reliably be detected using a saturation recovery true FISP sequence. Semiquantitative perfusion parameters upslope and peak signal intensity yielded similar results.


Assuntos
Doença da Artéria Coronariana/patologia , Circulação Coronária , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Meios de Contraste , Doença da Artéria Coronariana/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Gadolínio DTPA , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Cintilografia , Sensibilidade e Especificidade
8.
Radiology ; 237(1): 67-74, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16126922

RESUMO

PURPOSE: To prospectively assess myocardial perfusion before and after successful intervention in patients suspected of having single-vessel coronary artery disease by using a steady-state free precession (SSFP) perfusion magnetic resonance (MR) imaging sequence. MATERIALS AND METHODS: Local ethics committee approval and informed consent were obtained. Rest-stress perfusion MR imaging studies were performed in 18 patients with coronary artery disease (12 men, six women; mean age, 58.6 years +/- 13.6 [standard deviation]; range, 30-79 years) at 1.5 T with a multisection saturation-recovery SSFP sequence and 0.025 mmol gadopentetate dimeglumine per kilogram of body weight. MR studies were performed before (n = 18), several days after (n = 18), and 8 months after (n = 10) coronary intervention. Nine patients underwent percutaneous transluminal coronary angioplasty (PTCA) alone, and nine patients underwent PTCA with stent placement. Myocardial perfusion reserve index (MPRI) was calculated by dividing results of myocardial perfusion at maximal vasodilation by results at rest. The standard for myocardial perfusion was technetium 99m tetrofosmin single photon emission computed tomography. Statistical significance was tested with univariate variance analysis and Student t tests. RESULTS: In the area of the stenosed vessel, MPRI was 1.04 +/- 0.24 before treatment and 2.18 +/- 0.57 several days afterward (P < .001). In remote areas, MPRI was 2.42 +/- 0.44. In the stent group, MPRI increased by 156%, from 0.99 +/- 0.20 before stent placement to 2.53 +/- 0.53 after (P < .001). Similarly, in the PTCA only group, MPRI increased by 72%, from 1.08 +/- 0.27 before PTCA to 1.87 +/- 0.39 after (P < .001). At follow-up in patients without recurring chest pain, MPRI was 2.14 +/- 0.37 in the area of the treated artery and 2.29 +/- 0.47 in remote areas (P = .06). CONCLUSION: The MPRI, derived from rest-stress examinations, can provide information on success of interventional procedures in stenosed coronary arteries.


Assuntos
Angioplastia Coronária com Balão , Circulação Coronária/fisiologia , Doença das Coronárias/fisiopatologia , Doença das Coronárias/terapia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Angiografia Coronária , Doença das Coronárias/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Stents , Tomografia Computadorizada de Emissão de Fóton Único
9.
J Magn Reson Imaging ; 21(5): 596-603, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15834920

RESUMO

PURPOSE: To demonstrate the feasibility of detecting atherosclerotic vascular disease using an innovative magnetic resonance angiography (MRA) protocol in combination with a dedicated whole-body MR scanner with new surface coil technology. MATERIALS AND METHODS: A total of 10 volunteers and eight patients with peripheral arterial occlusive disease (PAOD) were examined at 1.5 T. Conventional digital subtraction angiography (DSA) of the symptomatic region was available as a reference standard in all eight patients. Depending on subjects' size, four to five three-dimensional data sets were acquired using an adapted injection protocol. Images were assessed independently by two readers for vascular pathology. Additionally, signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) were measured. RESULTS: Whole-body MRA yielded excellent sensitivity and specificity of more than 95% for both readers with high interobserver agreement (k = 0.93). Surface coil signal reception rendered a high SNR (mean 151.28 +/- 54.04) and CNR (mean 120.75 +/- 46.47). Despite lower SNR and CNR of the cranial and cervical vessels, a two-step injection protocol exhibited less venous superposition and therefore proved to be superior compared to single-bolus injection. CONCLUSION: Our approach provides accurate noninvasive high-resolution imaging of systemic atherosclerotic disease, covering the arterial vasculature from intracranial arteries to distal runoff vessels. The recently introduced MR scanner and coil technology is feasible to significantly increase the performance of whole-body MRA.


Assuntos
Arteriopatias Oclusivas/diagnóstico , Angiografia por Ressonância Magnética/instrumentação , Doenças Vasculares Periféricas/diagnóstico , Adulto , Idoso , Angiografia Digital , Arteriopatias Oclusivas/diagnóstico por imagem , Meios de Contraste , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doenças Vasculares Periféricas/diagnóstico por imagem , Sensibilidade e Especificidade
11.
J Thorac Cardiovasc Surg ; 129(3): 607-14, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15746745

RESUMO

OBJECTIVES: We sought to evaluate graft patency, flow, and flow reserve in patients with minimally invasive direct coronary artery bypass surgery of internal thoracic artery grafts by a combined magnetic resonance protocol with a phase-contrast technique and magnetic resonance angiography. METHODS: At 1.5 T (Magnetom Sonata, Siemens), 30 symptomatic patients with 30 left internal thoracic artery grafts were examined 6 years after minimally invasive surgical intervention. Navigator-gated magnetic resonance angiography and contrast-enhanced FLASH-3D magnetic resonance angiography (0.2 mmol gadopentate-diethylene triamine pentetic acid [Gd-DTPA]/kg body weight) was used to assess bypass patency. Phase-contrast flow measurements with retrospective gating were performed in the internal thoracic artery grafts at rest and after stress induction with dipyridamole (0.57 mg/kg body weight). Graft patency was evaluated by means of multidetector computed tomography (Sensation 16, Siemens). RESULTS: Internal thoracic artery grafts were occluded in 5 of 30 patients. In 6 patients the anastomosis to the left anterior descending artery was highly stenotic (>70 % ) at multidetector computed tomography. In patients with regular grafts (multidetector computed tomography), a significant improvement of graft flow ( P < .001) and diastolic/systolic peak velocity ratio ( P < .001) after stress induction was detected. Magnetic resonance angiography combined with flow reserve measurements could differentiate between occluded-stenotic and regular minimally invasive direct coronary artery bypass grafts. CONCLUSIONS: Magnetic resonance imaging allows a combined assessment of bypass patency and flow with flow reserve in patients after the minimally invasive direct coronary artery bypass operation. The protocol of this study might be applicable for the evaluation of graft status in symptomatic patients after revascularization.


Assuntos
Ponte de Artéria Coronária/métodos , Oclusão de Enxerto Vascular/diagnóstico , Imageamento por Ressonância Magnética/métodos , Artéria Torácica Interna/transplante , Grau de Desobstrução Vascular , Idoso , Constrição Patológica , Humanos , Angiografia por Ressonância Magnética , Artéria Torácica Interna/patologia , Pessoa de Meia-Idade , Fluxo Sanguíneo Regional , Sensibilidade e Especificidade
12.
Invest Radiol ; 39(9): 572-81, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15308940

RESUMO

RATIONALE AND OBJECTIVES: The aim of the study was to determine optimal thresholds for semiquantitative perfusion parameters and to evaluate the influence of different segmentation models in detecting malperfused regions. MATERIAL AND METHODS: In 6 healthy subjects and 13 patients with coronary artery disease, contrast-enhanced first-pass perfusion imaging was performed using a SR-TrueFISP-sequence. Thresholds for semiquantitative parameters were established, and different segmentation models of the left ventricular myocardium were tested. The standard of reference for patient studies was single photon emission computed tomography. RESULTS: Optimal thresholds were determined in healthy subjects for the perfusion parameters upslope, AUC, and peak SI of mv-0.5*std, mv-1.5*std, and mv-1.0*std, respectively. Using the optimal threshold for each parameter/segmentation combination sensitivities and specificities of stress studies were between 66% and 93% and 77% and 92%, respectively. Subdivision of radial segments into subendo/subepicardial segments increased sensitivities for perfusion deficits. CONCLUSIONS: Subdivision of radial myocardial segments is essential in analysis of magnetic resonance first-pass perfusion series. Semiquantitative perfusion parameters possess different sensitivities for the detection of perfusion deficits.


Assuntos
Circulação Coronária , Doença das Coronárias/diagnóstico , Imageamento por Ressonância Magnética , Adulto , Idoso , Meios de Contraste , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/fisiopatologia , Feminino , Gadolínio DTPA , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Compostos Organofosforados , Compostos de Organotecnécio , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único
13.
J Magn Reson Imaging ; 19(5): 555-63, 2004 May.
Artigo em Inglês | MEDLINE | ID: mdl-15112304

RESUMO

PURPOSE: To compare signal-to-noise ratio (SNR), contrast-to-noise (CNR) ratio, and diagnostic accuracy of a newly developed saturation recovery (SR)-TrueFISP-two-dimensional (2D) sequence with an SR-TurboFLASH-2D sequence. MATERIALS AND METHODS: In seven healthy subjects and nine patients with coronary artery disease (CAD), contrast-enhanced perfusion imaging (with Gd-DTPA) was performed with SR-TrueFISP and SR-TurboFLASH sequences. Hypoperfused areas were assessed qualitatively (scale = 0-4). Furthermore, SNR and CNR were calculated and semiquantitative perfusion parameters were determined from signal intensity (SI) time curves. Standard of reference for patient studies was single-photon emission computer tomography (SPECT) and angiography. RESULTS: The perception of perfusion deficits was superior in TrueFISP images (2.6 +/- 1.0) than in TurboFLASH (1.4 +/- 0.6) (P < 0.001). Phantom measurements yielded increased SNR (143 +/- 34%) and CNR (158 +/- 64%) values for TrueFISP. In patient/volunteer studies SNR was 61% to 100% higher and signal enhancement was 110% to 115% higher with TrueFISP than with TurboFLASH. Qualitative and semiquantitative assessment of perfusion defects yielded higher sensitivities for detection of perfusion defects with TrueFISP (68% to 78%) than with TurboFLASH (44% to 59%). CONCLUSION: SR-TrueFISP-2D perfusion imaging provides superior SNR and CNR than TurboFLASH imaging. Moreover, the dynamic range of SIs was found to be higher with TrueFISP, resulting in an increased sensitivity for detection of perfusion defects.


Assuntos
Doença da Artéria Coronariana/fisiopatologia , Coração/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Circulação Coronária , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Valores de Referência , Sensibilidade e Especificidade
14.
Eur Radiol ; 13 Suppl 4: L147-50, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15018181

RESUMO

Scimitar syndrome has a variable presentation depending on the age at which the diagnosis is made. We report a case of a young woman (age 18 years) with suspected right pulmonary hypoplasia in whom a scimitar syndrome was diagnosed. Using MRI morphological findings and hemodynamic significance of the syndrome were assessed. Left-to-right shunt was calculated from blood flow measurements performed in the ascending aorta, the main pulmonary artery, and the aberrant scimitar vein.


Assuntos
Hemodinâmica/fisiologia , Processamento de Imagem Assistida por Computador , Angiografia por Ressonância Magnética/métodos , Síndrome de Cimitarra/diagnóstico por imagem , Adolescente , Feminino , Seguimentos , Humanos , Radiografia , Síndrome de Cimitarra/fisiopatologia , Sensibilidade e Especificidade , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...