Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Anticancer Res ; 38(2): 1187-1199, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29374757

RESUMO

BACKGROUND: There is an ongoing debate whether solarium use (indoor tanning/artificial UV) may increase the risk for primary cutaneous malignant melanoma. AIM: A systematic literature search was conducted using MEDLINE and ISI Web of Science. Included studies were critically assessed regarding their risk of bias, and methodological shortcomings. Levels of evidence and grades of recommendation were determined according to guidelines of the Oxford Centre for Evidence-Based Medicine. Summary risk estimates and 95% confidence intervals for four different outcomes (ever exposure, exposure at younger age, high/low exposure vs. non-exposure) were derived from random-effects meta-analyses to account for possible heterogeneity across studies. RESULTS: Two cohort and twenty-nine case-control studies were eligible. Overall, quality of included studies was poor as a result of severe limitations, including possible recall and selection bias, and due to lack of interventional trials. Summary risk estimates suggested a weak association (odds ratio (OR)=1.19, 95% confidence interval (CI)=1.04-1.35, p=0.009) for ever-exposure to UV radiation from a solarium with melanoma risk. However, sensitivity analyses did not show an association for studies from Europe (OR=1.10; 95%CI=0.95-1.27, p=0.218), studies with low risk of bias (OR=1.15; 95%CI=0.94-1.41, p=0.179), and studies conducted after 1990 (OR 1.09; 95%CI=0.93-1.29, p=0.295). Moreover, moderate associations were found for first exposure to UV radiation from a solarium at younger age (<25 years) and high exposure (>10 sessions in lifetime) with melanoma risk. However, for all outcomes analyzed, overall study quality and resulting levels of evidence (3a-) and grades of recommendation (D) were low due to lack of interventional studies and severe limitations including unobserved or unrecorded confounding. CONCLUSION: Current scientific knowledge is mainly based on observational studies with poor quality data, which report associations but do not prove causality. At present, there is no convincing evidence that moderate/responsible solarium use increases melanoma risk.


Assuntos
Medicina Baseada em Evidências , Melanoma/etiologia , Neoplasias Induzidas por Radiação/etiologia , Banho de Sol , Raios Ultravioleta/efeitos adversos , Humanos , Metanálise como Assunto
2.
Ultrasonography ; : 140-148, 2018.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-731152

RESUMO

PURPOSE: This study was conducted to determine the influence of standoff material on acoustic radiation force impulse (ARFI) measurements in an elasticity phantom by using two different probes. METHODS: Using ARFI elastography, 10 observers measured the shear wave velocity (SWV, m/sec) in different lesions of an elasticity phantom with a convex 4C1 probe and a linear 9L4 probe. The experimental setup was expanded by the use of an interposed piece of porcine muscle as standoff material. The probe pressure on the phantom was registered. RESULTS: Faulty ARFI measurements occurred more often when quantifying the hardest lesion (74.0 kPa 4.97 m/sec) by the 9L4 probe with the porcine muscle as a standoff material interposed between the probe and the phantom. The success rate for ARFI measurements in these series was 52.4%, compared with 99.5% in the other series. The SWV values measured with the 9L4 probe were significantly higher (3.33±1.39 m/sec vs. 2.60±0.74 m/sec, P < 0.001 in the group without muscle) and were closer to the reference value than those measured with the 4C1 probe (0.25±0.23 m/sec vs. 0.85±1.21 m/sec, P < 0.001 in the same group). The SWV values measured when using the muscle as a standoff material were lower than those without the muscle (significant for 9L4, P=0.040). The deviation from the reference value and the variance increased significantly with the 9L4 probe if the muscle was in situ (B=0.27, P=0.004 and B=0.32, P < 0.001). In our study, the pressure exerted by the operator had no effect on the SWV values. CONCLUSION: The presence of porcine muscle acting as a standoff material influenced the occurrence of failed measurements as well as the variance and the accuracy of the measured values. The linear high-frequency probe was particularly affected.


Assuntos
Acústica , Elasticidade , Técnicas de Imagem por Elasticidade , Músculos , Valores de Referência , Transdutores , Ultrassonografia
3.
Ultrasonography ; : 345-352, 2016.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-731222

RESUMO

PURPOSE: The purpose of this study was to compare the reliability of ultrasound-based shear wave elastography in regions of homogeneous versus heterogeneous elasticity by using two different probes. METHODS: Using acoustic radiation force impulse (ARFI) elastography, we measured the shear wave velocity (SWV) in different lesions of an elastography phantom with the convex 4C1 probe and the linear 9L4 probe. The region of interest (ROI) was positioned in such a way that it was partly filled by one of the lesions (0%, 25%, 50%, 75%, and 100%) and partly by the background of the phantom (100%, 75%, 50%, 25%, and 0%, respectively). RESULTS: The success rate was 98.5%. The measured value and the reference value of SWV correlated significantly (r=0.89, P<0.001). Further, a comparison of the two probes revealed that there was no statistical difference in either the mean or the variance values. However, the deviation of SWV from the reference was higher in the case of the 9L4 probe than in the case of the 4C1 probe, both overall and in measurements in which the ROI contained structures of different elasticity (P=0.021 and P=0.002). Taking into account all data, for both probes, we found that there was a greater spread and deviation of the SWV from the reference value when the ROI was positioned in structures having different elastic properties (standard deviation, 0.02±0.01 m/sec vs. 0.04±0.04 m/sec; P=0.010; deviation from the reference value, 0.21±0.12 m/sec vs. 0.38±0.27 m/sec; P=0.050). CONCLUSION: Quantitative ARFI elastography was achievable in structures of different elasticity; however, the validity and the reliability of the SWV measurements decreased in comparison to those of the measurements performed in structures of homogeneous elasticity. Therefore, a convex probe is preferred for examining heterogeneous structures.


Assuntos
Acústica , Técnicas de Imagem por Elasticidade , Elasticidade , Imagens de Fantasmas , Características da População , Valores de Referência , Transdutores , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...