Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Osteoporos Int ; 20(11): 1929-38, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19319618

RESUMO

UNLABELLED: Radiographic images of bone cores taken from cadaver proximal femora provided two-dimensional parameters of projected trabecular patterns that correlated highly with conceptually equivalent three-dimensional parameters in the same cores. Measurements also highly correlated with yield stress, suggesting that both parameters have similar biomechanical qualities. INTRODUCTION: We compared morphometric measurements of trabecular patterns in two-dimensional (2D) projection radiographic images of cores from cadaver proximal femoral bones with conceptually equivalent measurements from three-dimensional microcomputed tomography (3D microCT) images. METHODS: Seven cadaver proximal femora provided 47 excised cores from seven regions. Digitized radiographs of those cores were processed with software that extracts trabecular patterns. Measurements of their distribution, geometry, and connectivity were compared with 3D parameters of similar definition derived from microCT of those cores. The relationship between 2D and 3D measurements and yield stress was also examined. RESULTS: 2D measurements strongly correlated with conceptually equivalent measurements obtained using 3D microCT. In all cases, the correlation coefficients were high, ranging from r = 0.84 (p < 0.001) to r = 0.93 (p < 0.001). The correlation coefficients between 2D and 3D measurements and yield stress of the cores were also high (r = 0.60 and 0.82, p < 0.001, respectively). CONCLUSIONS: These findings provide correlative and biomechanical evidence supporting the qualitative similarity of 2D microstructural parameters extracted from plain proximal femoral core X-ray images to conceptually equivalent 3D microstructural measurements of those same cores.


Assuntos
Fêmur/diagnóstico por imagem , Idoso , Densidade Óssea , Fêmur/fisiologia , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Estresse Mecânico , Microtomografia por Raio-X/métodos
2.
Radiologe ; 40(12): 1141-8, 2000 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-11197932

RESUMO

MRI is the most accurate noninvasive technique available for assessment of normal articular cartilage and cartilage lesions. MRI cannot only provide morphologic information about the area of damage, but can also provide unique insight into the biochemical composition of the articular cartilage. New image processing techniques such as three-dimensional mapping of cartilage thickness will help to establish automated analysis of cartilage loss. Theses techniques are ideally suited for monitoring patients who undergo treatment with new chondroregenerative drugs.


Assuntos
Cartilagem Articular/patologia , Aumento da Imagem , Imageamento por Ressonância Magnética , Osteoartrite/diagnóstico , Análise de Fourier , Glicosaminoglicanos/metabolismo , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Osteoartrite/etiologia
3.
Int J Artif Organs ; 22(8): 559-65, 1999 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10533912

RESUMO

The effects of centrifugal pumps on blood components other than erythrocytes, namely platelets and their interaction with the coagulation system, are not very well known. In a comparative study with three centrifugal pumps (BioMedicus BP-80, St. Jude Isoflow, and Sarns Delphin) and the Stockert roller pump hemolysis, platelet counts, thromboplastin and partial thromboplastin times, as well as resonance thrombography (RTG) parameters for the assessment of platelet and coagulation function were evaluated in vitro. Normalized indices of hemolysis (NIH) with ACD anticoagulation after 360 minutes were 0.008+/-0.004 (Isoflow), 0.018+/-0.017 (BP-80), 0.085+/-0.051 (Delphin), and 0.049+/-0.010 g/1001 (roller pump). Plasmatic coagulation was activated in all circuits. Platelet function was severely inhibited by the BP-80, indicated by increase in RTG platelet time to 358%+/-150% of initial values compared to 42%+/-29% (Isoflow), 40%+/-20% (Delphin), and 12%+/-10% (roller pump). Fibrin polymerization was affected similarly. The large surface area of the BP-80 leads to an extensive activation of platelets and plasminogen.


Assuntos
Coagulação Sanguínea , Eritrócitos/patologia , Circulação Extracorpórea/instrumentação , Coração Auxiliar , Agregação Plaquetária , Desenho de Equipamento , Segurança de Equipamentos , Estudos de Avaliação como Assunto , Estudos de Viabilidade , Coração Auxiliar/efeitos adversos , Hemólise , Humanos , Contagem de Plaquetas , Valores de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...