1.
Materials (Basel) ; 13(1)2020 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-31947782

RESUMO

The aim of this retrospective study was to evaluate the clinical outcome of surgical management of small versus large, isolated orbital floor fractures (OFFs) using polyglactin 910/polydioxanone (Ethisorb®). Covering a four-year period (2010-2013), all records concerning midfacial fractures with involvement of the orbit were screened. Isolated fractures of the orbital floor as well as combined injuries of the orbital floor and medial wall that had been treated surgically using polyglactin 910/polydioxanone (Ethisorb®) were included. Patients underwent a preoperative, a postoperative, and a late ophthalmologic assessment. The clinical outcomes of surgically managed small OFFs up to 2 cm2 were statistically analyzed and compared to clinical results in larger defects. The final sample included 61 patients (25 women, 36 men). Fractures up to 2 cm2 were found in 33 patients (54.1%), whereas 28 patients (45.9%) suffered from OFFs larger than 2 cm2. The clinical outcomes did not significantly differ between both sample categories, and statistical analysis showed a power of 0.91 to detect a potentially existing difference. On final examination, 52 patients were free of any clinical symptoms, whereas minor issues were found in seven subjects, and two patients suffered from severe impairment. In conclusion, polyglactin 910/polydioxanone (Ethisorb®) seems to be a suitable material for surgical repair of both small and large OFFs.

2.
J Prosthodont ; 29(1): 62-68, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30624832

RESUMO

PURPOSE: Various resin cements and priming agents are available for adhesive luting of zirconia restorations. The purpose of this study was to investigate how cement type and priming protocol affect the shear bond strength on zirconia ceramics. MATERIALS AND METHODS: Yttria-stabilized tetragonal zirconia polycrystalline ceramic cylinders were bonded to flat zirconia ceramic surfaces using 7 commercially available resin cements. Ten specimens of each cement group were pretreated with a universal primer, and 10 specimens per group were bonded without pretreatment. In addition, 10 specimens per group were pretreated with system-specific zirconia primers, which were available for 3 cements. Altogether, 170 bonded specimens were water-stored, thermal-cycled, and then submitted to shear bond strength tests. The shear bond strength and the fracture types were documented. Differences in shear bond strengths were assessed using 2-way ANOVA with post-hoc test (α = 0.05). A point-biserial correlation was run between the fracture patterns and the shear bond strengths. RESULTS: The mean shear bond strengths of cements in the unprimed group showed large variations between 2.52 ± 3.01 (mean ± SD) MPa and 33.15 ± 7.35 MPa. Pretreating the specimens with a universal primer improved the shear bond strengths significantly in all groups (p < 0.05) with a range of 21.80 ± 12.51 to 57.20 ± 11.40 MPa. The system-specific primers also improved the shear bond strength significantly, compared to the unprimed group (p < 0.01); however, only one system-specific primer achieved a shear bond strength superior to the universal primer (p < 0.01). There was also a statistical correlation between the fracture type and the shear bond strength (p < 0.0005), with cohesively fractured specimens showing higher shear bond strengths (37.24 ± 19.87 MPa) than adhesively fractured specimens (23.10 ± 17.65 MPa) (p < 0.001). CONCLUSION: Using universal primer can enhance the maximal shear bond strength of zirconia.


Assuntos
Colagem Dentária , Cerâmica , Análise do Estresse Dentário , Teste de Materiais , Cimentos de Resina , Resistência ao Cisalhamento , Propriedades de Superfície , Zircônio
3.
Materials (Basel) ; 11(3)2018 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-29518022

RESUMO

Computer-aided design and computer-aided manufacturing (CAD/CAM) denture base manufacturers claim to produce their resin pucks under high heat and pressure. Therefore, CAD/CAM dentures are assumed to have enhanced mechanical properties and, as a result, are often produced with lower denture base thicknesses than conventional, manually fabricated dentures. The aim of this study was to investigate if commercially available CAD/CAM denture base resins have more favourable mechanical properties than conventionally processed denture base resins. For this purpose, a series of three-point bending tests conforming to ISO specifications were performed on a total of 80 standardised, rectangular CAD/CAM denture base resin specimens from five different manufacturers (AvaDent, Baltic Denture System, Vita VIONIC, Whole You Nexteeth, and Wieland Digital Dentures). A heat-polymerising resin and an autopolymerising resin served as the control groups. The breaking load, fracture toughness, and the elastic modulus were assessed. Additionally, the fracture surface roughness and texture were investigated. Only one CAD/CAM resin showed a significantly increased breaking load. Two CAD/CAM resins had a significantly higher fracture toughness than the control groups, and all CAD/CAM resins had higher elastic moduli than the controls. Our results indicate that CAD/CAM denture base resins do not generally have better mechanical properties than manually processed resins. Therefore, the lower minimum denture base thicknesses should be regarded with some caution.

4.
Clin Oral Investig ; 22(8): 2829-2835, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29468600

RESUMO

OBJECTIVES: Resin polymerisation shrinkage reduces the congruence of the denture base with denture-bearing tissues and thereby decreases the retention of conventionally fabricated dentures. CAD/CAM denture manufacturing is a subtractive process, and polymerisation shrinkage is not an issue anymore. Therefore, CAD/CAM dentures are assumed to show a higher denture base congruence than conventionally fabricated dentures. It has been the aim of this study to test this hypothesis. MATERIALS AND METHODS: CAD/CAM dentures provided by four different manufacturers (AvaDent, Merz Dental, Whole You, Wieland/Ivoclar) were generated from ten different master casts. Ten conventional dentures (pack and press, long-term heat polymerisation) made from the same master casts served as control group. The master casts and all denture bases were scanned and matched digitally. The absolute incongruences were measured using a 2-mm mesh. RESULTS: Conventionally fabricated dentures showed a mean deviation of 0.105 mm, SD = 0.019 from the master cast. All CAD/CAM dentures showed lower mean incongruences. From all CAD/CAM dentures, AvaDent Digital Dentures showed the highest congruence with the master cast surface with a mean deviation of 0.058 mm, SD = 0.005. Wieland Digital Dentures showed a mean deviation of 0.068 mm, SD = 0.005, Whole You Nexteeth prostheses showed a mean deviation of 0.074 mm, SD = 0.011 and Baltic Denture System prostheses showed a mean deviation of 0.086 mm, SD = 0.012. CONCLUSIONS: CAD/CAM produces dentures with better fit than conventional dentures. CLINICAL RELEVANCE: The present study explains the clinically observed enhanced retention and lower traumatic ulcer-frequency in CAD/CAM dentures.


Assuntos
Desenho Assistido por Computador , Materiais Dentários/química , Planejamento de Dentadura , Retenção de Dentadura , Bases de Dentadura , Técnicas In Vitro , Propriedades de Superfície
5.
J Craniomaxillofac Surg ; 45(8): 1201-1204, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28610930

RESUMO

PURPOSE: The measurement of excursive jaw movements is an important instrument for evaluating the functional condition of the temporomandibular system. Dento-maxillofacial development differs widely within different age, weight or height clusters. Tooth eruption is part of the development of the temporomandibular system. Therefore, the dental developmental stage might reflect temporomandibular development more appropriately. The aim of this study was to investigate whether the dental age is a more suitable parameter for evaluating the mandibular movement range of children in the mixed dentition stage than chronological age. MATERIALS AND METHODS: In a prospective study, the mandibular movement range and relevant temporomandibular findings of 146 children aged 8-10 yr were assessed clinically. Alginate impressions were taken and dental casts were generated. Dental age was assessed from the casts. RESULTS: The mean mouth opening capacity was 46.2 mm (SD = 5.2); the mean laterotrusion to the left was 10.1 mm (SD = 1.9) and to the right 10.0 mm (SD = 1.8). For protrusion, the mean value was 9.1 mm (SD = 2.0). There was a statistically highly significant correlation between dental age and maximal active mouth opening extent. Statistically significant correlations between chronological age and active jaw movement capacity could not be shown. CONCLUSIONS: In children in the mixed dentition stage, dental age seems to reflect the developmental stage of the temporomandibular system more adequately than chronological age. Therefore, dental age-related normative values could be more appropriate for evaluating the temporomandibular system in children. CLINICAL TRIAL REGISTRATION NUMBER: 20100302-161.


Assuntos
Determinação da Idade pelos Dentes , Mandíbula/fisiologia , Fatores Etários , Criança , Dentição Mista , Feminino , Humanos , Masculino , Estudos Prospectivos , Amplitude de Movimento Articular
6.
Int J Prosthodont ; 30(2): 116-122, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28267817

RESUMO

PURPOSE: The introduction of computer-aided design/computer-assisted manufacture (CAD/CAM) technology into removable denture prosthodontics enables denture adaptation in fewer patient visits, an advantage that appeals to dentists and patients. Since manufacturers follow very different approaches, an evaluation of the different clinical CAD/CAM complete denture fabrication protocols is desirable. The aim of this article is to assess and evaluate the different clinical fabrication protocols of currently available CAD/CAM denture systems to provide decision support for dental practitioners. MATERIALS AND METHODS: The information for the present article was gathered by questionnaires from (in alphabetical order) Global Dental Science, Merz Dental, Wieland Dental + Technik, Ivoclar Vivadent, VITA Zahnfabrik, and Whole You, and complemented with results from the authors' clinical experience. RESULTS: Wieland Digital Denture involves four patient visits. Both AvaDent digital dentures and Whole You Nexteeth enable denture fabrication in three (including a try-in session) or two (without try-in) visits. Baltic Denture System stipulates complete denture fabrication in two visits, and VITA VIONIC material system is an open system enabling choice between different treatment protocols. It can be combined with several open scanners, CAD software options, and milling machines. CONCLUSION: The available CAD/CAM denture fabrication systems provide a variety of advantages, and the decision on a system should depend on the dentist's prosthodontic expertise, patient throughput rate, and requirements regarding denture individualization.


Assuntos
Desenho Assistido por Computador/instrumentação , Planejamento de Dentadura , Humanos , Software , Inquéritos e Questionários
7.
Swiss Dent J ; 127(2): 122-128, 2017 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-28266685

RESUMO

Malocclusal traits can impair dental health and aesthetical appearance. The index of orthodontic treatment need (IOTN) identifies the patients who benefit the most from orthodontic treatment. The aim of this study was to assess the malocclusion frequencies and the orthodontic treatment need among Austrian children in the mixed dentition stage, since there is no pre-existing data from Austria. In the present study, 157 children aged between 8 and 10 years were examined. Following an anamnesis questionnaire, which included a question about the parents' perceived treatment need, the children were examined clinically and dental impressions were taken. The sagittal molar relationship, overjet, overbite and the presence of cross- or scissor bite were registered. The treatment need was assessed using the dental health component (DHC) of the index of orthodontic treatment need (IOTN). 64.3% (95% CI [56.8, 71.8]) of the children showed Angle class I molar relation, 33.1% (95% CI [25.8, 40.5]) class II and 2.5% (95% CI [0.1, 5.0]) Angle class III relation. Crossbite was found in 36.3% (95% CI [28.8, 43.8]) of the participants. A treatment need for medical reasons (IOTN 4 or 5) was found in 30.6% (95% CI [23.4, 37.8]). There was no statistically significant relationship between objective treatment need and the parents' perception. The malocclusion frequencies and the treatment need assessed in the present study appeared to be comparable to those assessed in other countries. The data supports the opinion that orthodontic screening is important and necessary at this stage of dental development, also due to the discordance between objective and perceived treatment need.


Assuntos
Dentição Mista , Necessidades e Demandas de Serviços de Saúde/estatística & dados numéricos , Má Oclusão/epidemiologia , Má Oclusão/terapia , Ortodontia Corretiva/estatística & dados numéricos , Áustria , Criança , Estudos Transversais , Feminino , Previsões , Necessidades e Demandas de Serviços de Saúde/tendências , Humanos , Masculino , Ortodontia Corretiva/tendências , Estudos Prospectivos
8.
Appl Spectrosc ; 71(7): 1600-1612, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27956591

RESUMO

Water absorbed to poly(methyl methacrylate) (PMMA)-based CAD/CAM (computer-assisted design/computer-assisted manufacturing) prosthodontics can alter their properties including hardness and stability. In the present contribution, water absorption and desorption kinetics under defined experimental conditions were monitored employing several supplementary and advanced Fourier transform infrared (FT-IR) spectroscopic techniques in combination with multivariate analysis (MVA). In this synergistic vibrational spectroscopic multimethod approach, first a novel near-infrared (NIR) diffuse fiber optic probe reflection spectroscopic method was established for time-resolved analysis of water uptake within seven days under controlled conditions. Near-infrared water absorbance spectra in a wavenumber range between 5288-5100 cm-1 (combination band) and 5424-5352 cm-1 (second overtone) were used establishing corresponding calibration and validation models to quantify the amount of water in the milligram range. Therefore, 14 well-defined samples exposed to prior optimized experimental conditions were taken into consideration. The average daily water uptake conducting reference analysis was calculated as 22 mg/day for one week. Additionally, in this study for the first time NIR two-dimensional correlation spectroscopy (2D-COS) was conducted to monitor and interpret the spectral dynamics of water absorption on the prosthodontics in a wavenumber range of 5100-5300 cm-1. For sensitive time-resolved recording of water desorption, a recently developed high-temperature, high-pressure FT-IR reaction cell with water-free ultra-dry in situ and operando operation was applied. The reaction cell, as well as the sample holder, was fully made of quartz glass, with no hot metal or ceramic parts in the vicinity of the high temperature zone. Applying a temperature gradient in the range of 25-150 ℃, mid-infrared (MIR) 2D-COS was successfully conducted to get insights into the dynamic behavior of O-H (1400-1800 cm-1) absorption bands with increasing temperature over time and the release of CO2 (2450 cm-1) from the polymers. In addition, an ATR FT-IR imaging setup was optimized in order to investigate the surface homogeneity of the PMMA-based resins with a spatial resolution to 2 µm. From this vibrational spectroscopic multimethod approach and the collection of several analytical data, conclusions were drawn as to which degree the surface structure and/or its porosity have an impact onto the amount of water absorption.

9.
Clin Oral Investig ; 21(5): 1697-1705, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27704295

RESUMO

OBJECTIVES: Computer-aided design (CAD)/computer-aided manufacturing (CAM) dentures are assumed to have more favourable material properties than conventionally fabricated dentures, among them a lower methacrylate monomer release. The aim of this study was to test this hypothesis. MATERIALS AND METHODS: CAD/CAM dentures were generated from ten different master casts by using four different CAD/CAM systems. Conventional, heat-polymerised dentures served as control group. Denture weight and volume were measured; the density was calculated, and the denture surface area was assessed digitally. The monomer release after 7 days of water storage was measured by high-performance liquid chromatography. RESULTS: Whole You Nexteeth and Wieland Digital Dentures had significantly lower mean volume and weight than conventional dentures. Baltic Denture System and Whole You Nexteeth had a significantly increased density. Baltic Denture System had a significantly smaller surface area. None of the CAD/CAM dentures released significantly less monomer than the control group. CONCLUSIONS: All tested dentures released very low amounts of methacrylate monomer, but not significantly less than conventional dentures. A statistically significant difference might nevertheless exist in comparison to other, less recommendable denture base materials, such as the frequently used autopolymerising resins. CLINICAL RELEVANCE: CAD/CAM denture fabrication has numerous advantages. It enables the fabrication of dentures with lower resin volume and lower denture weight. Both could increase the patient comfort. Dentures with higher density might exhibit more favourable mechanical properties. The hypothesis that CAD/CAM dentures release less monomer than conventional dentures could, however, not be verified.


Assuntos
Desenho Assistido por Computador , Materiais Dentários/química , Planejamento de Dentadura , Metilmetacrilato/química , Cromatografia Líquida de Alta Pressão , Teste de Materiais
10.
J Periodontol ; 87(1): 41-7, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26447750

RESUMO

BACKGROUND: With declining general health, the maintenance of oral health becomes increasingly difficult. Unfortunately, health care resources are limited. An assessment tool for detecting a patient's need for oral health care assistance would promote its adequate distribution. The aim of this study is to evaluate if the Shulman clock-drawing test score is a suitable assessment tool for determining the need for oral hygiene assistance. METHODS: Data collected from recent dental checkups of 126 inhabitants of five Austrian residential care facilities were analyzed. The Shulman clock-drawing test score was used as a measure for cognitive abilities and related to tooth and denture hygiene indices, which were assessed using the approximal space plaque index (API) and the denture plaque index (DPI). RESULTS: Shulman score values were distributed almost evenly in the study population. The mean API was 83.6% (SD 20.2%) for the maxilla and 94.9% (SD 15.6%) for the mandible. The mean DPI was 43.9% (SD 31.4%). Cognitive impairment was not statistically related to the dental or denture hygiene index. CONCLUSIONS: A high Shulman clock-drawing test score indicates the need for oral hygiene assistance, but it is not suitable as a single tool to assess this need. Patients with other disabilities might equally qualify for assistance. Dentures, however, can be cleaned quickly and efficiently independently of patient compliance; therefore, cleaning the patients' dentures should be part of nursing personnel's daily care routine for every patient.


Assuntos
Cognição , Higiene Bucal , Áustria , Dentaduras , Humanos , Saúde Bucal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...