Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 166
Filtrar
1.
EuroIntervention ; 20(1): 85-94, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37982152

RESUMO

BACKGROUND: Transcatheter aortic valve implantation is an effective treatment for patients with aortic stenosis; however, complications related to paravalvular leakage (PVL) persist, including increased risk of mortality, cardiovascular mortality, and rehospitalisation. AIMS: We sought to evaluate the clinical outcomes and valve performance at 1 year in patients with severe aortic stenosis treated with the ACURATE neo2 valve in a post-market clinical setting. METHODS: Valve Academic Research Consortium-2 safety events were assessed up to 1 year. Independent core laboratories evaluated echocardiographic measures of valve performance and hypoattenuated leaflet thickening (HALT; as measured by four-dimensional computed tomography). RESULTS: The study enrolled 250 patients (64% female; mean age: 81 years; baseline Society of Thoracic Surgeons risk score: 2.9±2.0%); 246 patients were implanted with ACURATE neo2. All-cause mortality was 0.8% at 30 days and 5.1% at 1 year. The 1-year rates for stroke and disabling stroke were 3.0% and 1.3%, respectively. Overall, HALT of >50% leaflet involvement of at least one leaflet was present in 9% of patients at 30 days and in 12% of patients at 1 year. No association was observed between the presence of HALT and 1-year clinical or haemodynamic outcomes. Early haemodynamic improvements were maintained up to 1 year (mean aortic valve gradient: 47.6±14.5 mmHg at baseline, 7.6±3.2 mmHg at 1 year; mean aortic valve area: 0.7±0.2 cm2 at baseline, 1.7±0.4 cm2 at 1 year). At 1 year, 99% of patients had mild or no/trace PVL (<1% had moderate PVL; no patient had severe PVL). CONCLUSIONS: The study outcomes confirm favourable performance and safety up to 1 year in patients treated with ACURATE neo2 in routine clinical practice. (ClinicalTrials.gov: NCT04655248).


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Desenho de Prótese , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 102(2): 273-280, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37221985

RESUMO

BACKGROUND: NobleStitch EL is a novel suture-based technique used for patent foramen ovale (PFO) closure and an alternative to traditional double-disc devices without the need for antithrombotic therapy. However, successful closure rates are still unknown, and certain anatomies may be unfavorable for successful closure. AIMS: We assessed the efficacy of the NobleStitch EL and sought to identify patient-related anatomical features associated with successful suture-based closure. METHODS: We included 55 patients who underwent PFO closure with the NobleStitch EL in The Netherlands and Switzerland. Successful closure was defined as residual right-to-left shunt grade ≤1 with Valsalva maneuver at a cardiac ultrasound. Predefined possible anatomical determinants for effective closure included PFO length, atrial septal aneurysm, PFO entry- and exit diameter. RESULTS: Successful closure was achieved in 33 patients (60%). The PFO length was shorter in patients with successful closure compared to unsuccessful closure with a median length of 9.6 mm (IQR 8.0-15.0) versus 13.3 mm (IQR 11.4-18.6) on preprocedural ultrasound (p = 0.041) and 9.9 mm (IQR 8.0-13.1) versus 12.5 mm (IQR 9.7-15.4) on angiography (p = 0.049). Additionally, the PFO exit diameter and PFO volume were smaller in patients with successful closure than unsuccessful closure, with a mean diameter of 7.0 ± 3.1 mm versus 9.5 ± 3.8 mm (p = 0.015) and a median volume of 381 mm3 (IQR 286-894) versus 985 mm3 (IQR 572-1550) (p = 0.016). CONCLUSION: In our study cohort, the successful PFO closure rate using NobleStitch EL was relatively low (60%). With this alternative procedure, patients with a small PFO driven by a short PFO tunnel length and small exit diameter seem to be eligible for successful suture-based closure.


Assuntos
Forame Oval Patente , Acidente Vascular Cerebral , Humanos , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/terapia , Forame Oval Patente/complicações , Resultado do Tratamento , Ecocardiografia Transesofagiana , Cateterismo Cardíaco , Suturas
3.
Catheter Cardiovasc Interv ; 101(6): 1134-1143, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37036268

RESUMO

OBJECTIVE: To determine the prognostic impact of coronary artery disease (CAD) in patients randomized to bivalirudin or unfractionated heparin (UFH) during transcatheter aortic valve replacement (TAVR). BACKGROUND: CAD is a common comorbidity among patients undergoing TAVR and studies provide conflicting data on its prognostic impact. METHODS: The Bivalirudin on Aortic Valve Intervention Outcomes-3 (BRAVO-3) randomized trial compared the use of bivalirudin versus UFH in 802 high-surgical risk patients undergoing transfemoral TAVR for severe symptomatic aortic stenosis. Patients were stratified according to the presence or absence of history of CAD as well as periprocedural anticoagulation. The coprimary endpoints were net adverse cardiac events (NACE; a composite of all-cause mortality, myocardial infarction, stroke, or major bleeding) and major Bleeding Academic Research Consortium (BARC) bleeding ≥3b at 30 days postprocedure. RESULTS: Among 801 patients, 437 (54.6%) had history of CAD of whom 223 (51.0%) received bivalirudin. There were no significant differences in NACE (adjusted odds ratio [OR]: 1.04; 95% confidence interval [CI]: 0.69-1.58) or BARC ≥ 3b bleeding (adjusted OR: 0.84; 95% CI: 0.51-1.39) in patients with vs without CAD at 30 days. Among CAD patients, periprocedural use of bivalirudin was associated with similar NACE (OR: 0.80; 95% CI: 0.47-1.35) and BARC ≥ 3b bleeding (OR: 0.64; 95% CI: 0.33-1.25) compared with UFH, irrespective of history of CAD (p-interaction = 0.959 for NACE; p-interaction = 0.479 for major bleeding). CONCLUSION: CAD was not associated with a higher short-term risk of NACE or major bleeding after TAVR. Periprocedural anticoagulation with bivalirudin did not show any advantage over UFH in patients with and without CAD.


Assuntos
Doença da Artéria Coronariana , Substituição da Valva Aórtica Transcateter , Humanos , Heparina/efeitos adversos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Antitrombinas/efeitos adversos , Resultado do Tratamento , Hirudinas/efeitos adversos , Hemorragia/induzido quimicamente , Fragmentos de Peptídeos/efeitos adversos , Proteínas Recombinantes/efeitos adversos
4.
Catheter Cardiovasc Interv ; 101(3): 505-510, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36651339

RESUMO

OBJECTIVE: The elevated risk of adverse events following percutaneous coronary intervention in diabetic patients persists with newer-generation DES. The polymer-free amphilimus-eluting stent (PF-AES) possesses characteristics with a potentially enhanced performance in patients with diabetes. Data from the 1-year follow-up period has been previously published. The aim of this subanalysis was to assess long-term performance of two contemporary drug-eluting stents (DES) in a diabetic population. METHODS: In the ReCre8 trial, patients were stratified for diabetes and troponin status, and randomized to implantation of a permanent polymer zotarolimus-eluting stent (PP-ZES) or PF-AES. The primary endpoint was target-lesion failure (TLF), a composite of cardiac death, target-vessel myocardial infarction and target-lesion revascularization. Clinical outcomes between discharge and 3 years follow-up were assessed. RESULTS: A total of 302 patients with diabetes were included in this analysis. After 3 years, TLF occurred in 12.5% of PP-ZES patients versus 10.0% in PF-AES patients (p = 0.46). Similarly, the separate components of TLF were comparable between the two study arms. The secondary composite endpoint of NACE was higher in the PP-ZES arm with 45 cases (29.6%) versus 30 cases (20.0%) in the PF-AES arm (p = 0.036). In the insulin-dependent diabetic population, TLF occurred in 19.1% of PP-ZES patients versus 10.4% of PF-AES patients (p = 0.21). NACE occurred in 40.4% of PP-ZES patients versus 27.1% of PF-AES patients (p = 0.10). CONCLUSIONS: This subanalysis shows that the use of PF-AES results in similar clinical outcomes as compared to PP-ZES, yet some benefits of use of PF-AES in diabetic patients may prevail. Future dedicated trials should confirm these findings.


Assuntos
Fármacos Cardiovasculares , Doença da Artéria Coronariana , Diabetes Mellitus , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/induzido quimicamente , Seguimentos , Fatores de Risco , Resultado do Tratamento , Diabetes Mellitus/diagnóstico , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Fármacos Cardiovasculares/efeitos adversos
5.
Cardiovasc Revasc Med ; 50: 8-12, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36681530

RESUMO

OBJECTIVE: Periprocedural stroke during transcatheter aortic valve replacement (TAVR) is a highly feared adverse event. The TriGUARD 3 cerebral embolic protection device (CEPD) may have the potential benefit of reduction of embolic events, but it still remains unclear whether it reduces the incidence of periprocedural stroke or transient ischemic attack (TIA). We aimed to investigate whether the latest TriGUARD 3 CEPD reduces the incidence of clinically overt stroke within 72 h or at discharge after TAVR. METHODS: In this prospective single-center study 117 patients (mean age 80.3 years, 53.8 % male) were included from July 2020 to December 2021. RESULTS: The primary efficacy endpoint of this study, periprocedural clinically overt stroke or TIA, within 72 h or at discharge after TAVR with the TriGUARD 3 CEPD occurred in 1/117 pts (0.8 %). Secondary endpoints (device related issues such as life-threatening or disabling bleeding, acute kidney injury, major vascular complications) were reported in 4/117 pts (3.4 %). CONCLUSIONS: This study suggests that the use of the latest TriGUARD 3™ CEPD in transfemoral TAVR seems to be associated with a low rate of clinically overt stroke and a low rate of device related adverse events, reflecting "real world" TAVR practice. However these results should be hypothesis generating and confirmed in a large RCT.


Assuntos
Estenose da Valva Aórtica , Dispositivos de Proteção Embólica , Embolia Intracraniana , Ataque Isquêmico Transitório , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Idoso de 80 Anos ou mais , Feminino , Ataque Isquêmico Transitório/etiologia , Ataque Isquêmico Transitório/prevenção & controle , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estudos Prospectivos , Fatores de Risco , Resultado do Tratamento , Fatores de Tempo , Embolia Intracraniana/diagnóstico por imagem , Embolia Intracraniana/etiologia , Embolia Intracraniana/prevenção & controle , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/epidemiologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
6.
EuroIntervention ; 2022 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-36440588

RESUMO

BACKGROUND: The next-generation ACURATE neo2 transcatheter aortic valve was designed for simplified implantation and to mitigate the risk of paravalvular leak (PVL) compared to the earlier device. AIMS: To collect clinical outcomes and device performance data, including echocardiography and 4-dimensional computed tomography (4D-CT) data, with the ACURATE neo2 transcatheter heart valve in patients with severe aortic stenosis (AS). METHODS: ACURATE neo2 PMCF is a single-arm, multicentre study of patients with severe AS treated in routine clinical practice. The primary safety endpoint was all-cause mortality at 30-days. The primary imaging endpoint was hypo-attenuated leaflet thickening (HALT), measured by core laboratory-adjudicated 4D-CT at 30 days. Secondary endpoints included VARC safety endpoints, procedural success, and evaluation of valve performance via core laboratory-adjudicated echocardiography. RESULTS: The study enrolled 250 patients at 18 European centres (mean age: 80.8 years; 63.6% female; mean STS score: 2.9±2.0%); 246 (98.4%) were successfully treated with ACURATE neo2. The 30-day rates for mortality and disabling stroke were 0.8% and 0%, respectively. The new permanent pacemaker implantation rate was 6.5%. HALT >50% was present in 9.3% of patients at 30 days. Valve haemodynamics improved from baseline to 30 days (mean aortic valve gradient: from 47.6±14.5 mmHg to 8.6±3.9 mmHg; mean aortic valve area: from 0.7±0.2 cm2 to 1.6±0.4 cm2). At 30 days, PVL was evaluated as none/trace in 79.2% of patients, mild in 18.9%, moderate in 1.9%, and severe in 0%. CONCLUSIONS: The study results support the safety and efficacy of TAVI with ACURATE neo2 in patients in routine clinical practice.

7.
Catheter Cardiovasc Interv ; 100(3): 439-448, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35830708

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an effective alternative to surgical aortic valve replacement for patients who are at increased surgical risk. Consequently, frailty is common in patients undergoing TAVR. OBJECTIVES: This study aims to investigate the impact of frailty on outcomes following TAVR. METHODS: A retrospective cohort study was conducted, including all TAVR candidates who visited the geriatric outpatient clinic for preoperative screening. Frailty status was assessed according to the Groningen Frailty Indicator. The primary outcome of the study was defined as the occurrence of postoperative complications, and this was evaluated according to the Clavien-Dindo classification. An additional analysis was performed to assess the impact of frailty on 1-year all-cause mortality and complications within 30 days of TAVR according to the Valve Academic Research Consortium (VARC-2) criteria. The VARC-2 criteria provide harmonized endpoint definitions for TAVR studies. RESULTS: In total, 431 patients with a mean age of 80.8 ± 6.2 years were included, of whom 56% were female. Frailty was present in 36% of the participants. Frailty was associated with a higher risk of the composite outcome of complications [adjusted odds ratio (OR): 1.55 (95% confidence interval, CI: 1.03-2.34)], 30-day mortality [adjusted OR: 4.84 (95% CI: 1.62-14.49)], 3-month mortality [adjusted OR: 2.52 (95% CI: 1.00-6.28)] and 1-year mortality [adjusted OR: 2.96 (95% CI: 1.46-6.00)]. CONCLUSIONS: Frailty is common in TAVR patients and is associated with an increased overall risk of postoperative complications, particularly mortality. Increased optimization of screening and treatment of frailty in the guidelines for valvular heart diseases is recommended.


Assuntos
Estenose da Valva Aórtica , Fragilidade , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Fragilidade/complicações , Fragilidade/diagnóstico , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Estudos Prospectivos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
8.
Cardiovasc Revasc Med ; 44: 71-77, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35739011

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is now an established treatment strategy for elderly patients with symptomatic aortic stenosis (AS) across the entire operative risk spectrum. Streamlined TAVR protocols along with reduced procedure time and expedited ambulation promote early hospital discharge. Selection of patients suitable for safe early discharge after TAVR might improve healthcare efficiency. STUDY DESIGN: The POLESTAR trial is an international, multi-center, prospective, observational study which aims to evaluate the safety of early discharge in selected patients who undergo TAVR with the supra-annular functioning self-expanding ACURATE Neo transcatheter heart valve (THV). A total of 250 patients will be included based on a set of baseline criteria indicating potential early discharge (within 48 h post-TAVR). Primary study endpoints include Valve Academic Research Consortium (VARC)-3 defined safety at 30 days and VARC-3 defined efficacy at 30 days and 1 year. Endpoints will be compared between early discharge and non-early discharge cohorts with a distinct landmark analysis at 48 h post-TAVR. Secondary endpoints include quality of life assessed using EQ5D-5L and Kansas City Cardiomyopathy Questionnaire (KCCQ) questionnaires and resource costs compared between discharge groups. SUMMARY: The POLESTAR trial prospectively evaluates safety and feasibility of an early discharge protocol for TAVR using the ACURATE Neo THV.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Qualidade de Vida , Estudos Prospectivos , Alta do Paciente , Desenho de Prótese , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Fatores de Risco
9.
J Invasive Cardiol ; 34(3): E218-E225, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35235528

RESUMO

BACKGROUND: The transcatheter aortic valve implantation (TAVI) population is mostly elderly and frail. Clinically significant incidental findings (SIFs) are commonly encountered in the work-up of TAVI patients. This is a systematic review of current literature on the occurrence of SIFs on computed tomography (CT) imaging preceding TAVI and their association with mortality, delayed planning, and procedure cancellation. METHODS: A systematic search on Medline, Embase, and Cochrane resulted in 19 retrospective studies (published from 2010-2020) reporting SIFs in the work-up for TAVI. A total of 6358 individuals from 19 studies were analyzed, with mean age of 80 years and sex equally divided. A random-effects meta-analysis was performed, with weighting based on study size. RESULTS: Pooled prevalence of patients with SIF was 22.2% (95% confidence interval [CI], 17.8-26.6) and most findings (48.3%) were found in the lungs. Pooled prevalence of new malignancies was 3.4% (95% CI, 2.5-4.4). Higher mortality in patients with SIF was only found in studies with a follow-up period >4 years (hazard ratio, 1.5-1.7). TAVI was more frequently cancelled in patients with SIF vs those with no SIF (ranges, 10.1%-47.1% vs 5.2%-37.0%, respectively). SIF did not delay time to TAVI (ranges, 6-91 days in SIF patients vs 4-81 days in non-SIF patients). CONCLUSION: SIFs are common in patients screened for TAVI. SIF is associated with a higher risk of TAVI cancellation and with increased mortality risk over the long term, which should be taken into consideration in decision making. These findings may help inform patients and aid patient selection.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Humanos , Achados Incidentais , Estudos Retrospectivos , Fatores de Risco , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
10.
Catheter Cardiovasc Interv ; 99(2): 366-372, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33811730

RESUMO

OBJECTIVES: The purpose of this analysis was to compare target-lesion failure (TLF) of a permanent polymer zotarolimus-eluting stent (PP-ZES) versus a polymer-free amphilimus-eluting stent (PF-AES) in diabetics. BACKGROUND: The improvement of outcomes with new-generation drug-eluting stent as seen in the general population is less pronounced among diabetics. The PF-AES introduces an elution-technology with potential enhanced performance in diabetics. METHODS: In this subanalysis of the ReCre8 trial, patients were randomized to either a PP-ZES or PF-AES after stratification for diabetes and troponin status. The primary device-oriented endpoint was TLF, a composite of cardiac death, target-vessel myocardial infarction and target-lesion revascularization. RESULTS: In the ReCre8 trial, 304 (20%) patients were diabetic and 96 (6%) had insulin-dependent diabetes mellitus. There was no statistically significant difference between the two study arms regarding the primary endpoint (PP-ZES 7.2% vs. PF-AES 4.0%; p = .21), although the composite of net adverse clinical events was higher in the PP-ZES arm (15.7 vs. 8.0%; p = .035). Stent thrombosis was low in both groups with no cases in the PP-ZES arm and 1 case in the PF-AES arm (p = .32). Regarding insulin-treated diabetics, TLF was higher in the PP-ZES arm (14.9 vs. 2.1%; p = .022). CONCLUSIONS: Diabetics could potentially benefit from a dedicated stent, releasing sirolimus with a lipophilic carrier (amphilimus-formulation). Future trials should confirm the potential benefit of a PF-AES in this population.


Assuntos
Fármacos Cardiovasculares , Doença da Artéria Coronariana , Diabetes Mellitus , Stents Farmacológicos , Intervenção Coronária Percutânea , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/induzido quimicamente , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Polímeros , Desenho de Prótese , Stents , Resultado do Tratamento
11.
Heart Vessels ; 37(2): 194-199, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34374824

RESUMO

Coronary sinus Reducer (CSR) implantation is currently recommended to relieve angina in patients with refractory symptoms despite optimal medical therapy and maximally achievable revascularization. The impact of diabetes mellitus on outcome after CSR implantation is at present unknown. We aimed to explore the impact of CSR in refractory angina patients with diabetes mellitus. Data from consecutive patients undergoing CSR implantation at four different centres between 2014 and 2018 were included. Patients were divided according to the presence or absence of diabetes mellitus. Primary objective of this analysis was to evaluate the clinical response to CSR implantation defined as an improvement of ≥ 1 classes of the Canadian Cardiovascular Society (CCS) Classification. A total of 219 patients were included, 116 (53%) of whom had diabetes mellitus. The median age of the population was 69 years and 167 patients (76%) were male. There were no significant differences between groups of patients with and without diabetes mellitus with respect to CCS class at baseline (p value = 0.32) and at follow-up (p = 0.75). Over a median follow-up of 393 [224-1004] days, 84 (72%) of the patients with diabetes mellitus met the primary outcome, similarly to those without diabetes mellitus (p = 0.28). Fifty-three patients (24%) did not have an improvement in CCS class and no one experienced worsening of angina. CSR implantation was equally effective in improving angina symptoms among patients with refractory angina and diabetes mellitus compared to patients without diabetes mellitus.


Assuntos
Seio Coronário , Diabetes Mellitus , Idoso , Angina Pectoris/diagnóstico , Angina Pectoris/etiologia , Angina Pectoris/cirurgia , Canadá , Seio Coronário/diagnóstico por imagem , Seio Coronário/cirurgia , Diabetes Mellitus/epidemiologia , Humanos , Masculino , Resultado do Tratamento
12.
Catheter Cardiovasc Interv ; 99(3): 664-673, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34582631

RESUMO

OBJECTIVES: to test the safety and efficacy of intravascular imaging and specifically optical coherence tomography (OCT) as a diagnostic tool for left main angioplasty and analyze the mid-term outcome accordingly. BACKGROUND: Clinical data and international guidelines recommend the use of intravascular imaging ultrasound (IVUS) to guide left main (LM) angioplasty. Despite early experience using OCT in this setting is encouraging, the evidence supporting its use is still limited. METHODS: ROCK II is a multicenter, investigator-driven, retrospective European study to compare the performance of IVUS and OCT versus angiography in patients undergoing distal-LM stenting. The primary study endpoint was target-lesion failure (TLF) including cardiac death, target-vessel myocardial infarction and target-lesion revascularization. We designed this study hypothesizing the superiority of intravascular imaging over angiographic guidance alone, and the non-inferiority of OCT versus IVUS. RESULTS: A total of 730 patients, 377 with intravascular-imaging guidance (162 OCT, 215 IVUS) and 353 with angiographic guidance, were analyzed. The one-year rate of TLF was 21.2% with angiography and 12.7% with intravascular-imaging (p = 0.039), with no difference between OCT and IVUS (p = 0.26). Intravascular-imaging was predictor of freedom from TLF (HR 0.46; 95% CI 0.23-0.93: p = 0.03). Propensity-score matching identified three groups of 100 patients each with no significant differences in baseline characteristics. The one-year rate of TLF was 16% in the angiographic, 7% in the OCT and 6% in the IVUS group, respectively (p = 0.03 for IVUS or OCT vs. angiography). No between-group significant differences in the rate of individual components of TLF were found. CONCLUSIONS: Intravascular imaging was superior to angiography for distal LM stenting, with no difference between OCT and IVUS.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Estudos Retrospectivos , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento , Ultrassonografia de Intervenção/métodos
13.
Am Heart J Plus ; 24: 100227, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38560639

RESUMO

Objectives: In an all-comers cohort undergoing percutaneous coronary intervention (PCI), we aimed to assess prevalence of high bleeding risk (HBR) patients and impact of HBR and dual antiplatelet therapy (DAPT) on clinical events. Background: HBR represents a complex subgroup of patients undergoing PCI. Methods: In the ReCre8 trial, patients undergoing PCI were stratified for troponin status and diabetes and randomized to a permanent polymer zotarolimus-eluting- or polymer-free amphilimus-eluting stent. Patients were treated with 12 months (troponin-positive) or one month (troponin-negative) of DAPT. We evaluated clinical outcomes in patients with and without HBR according to the Academic Research Consortium for High Bleeding Risk criteria. Results: From a total of 1488 patients included in this subanalysis, 406 patients (27.3 %) were identified as being at HBR. Among HBR patients, target-lesion failure (TLF) was similar after one year yet was higher after three years (13.3 % vs. 9.1 %; p = 0.013), compared to non-HBR patients. There was no difference in Bleeding Academic Research Consortium (BARC) 3 to 5 bleeding, however BARC 2 to 5 bleeding was higher after three years with 4.9 % vs. 3.0 % (p = 0.037). There were no differences between troponin-positive (12-months DAPT) and -negative (1-month DAPT) HBR patients with respect to ischemic and bleeding outcomes. Conclusions: In this all-comers population of PCI patients, a higher TLF rate among HBR patients at long-term follow-up was found, underlining the complexities involving treatment of HBR patients. We did not observe statistically significant differences in BARC 3 to 5 bleeding between HBR and non-HBR patients regardless of DAPT duration. Clinical trial registration: URL: http://www.clinicaltrials.gov, unique identifier: NCT02328898.

14.
JACC Cardiovasc Interv ; 14(22): 2477-2486, 2021 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-34794654

RESUMO

OBJECTIVES: The aim of this analysis was to assess long-term clinical outcomes of the polymer-free Amphilimus-eluting stent (PF-AES) compared with a latest generation permanent-polymer drug-eluting stent (DES) in an all-comers population. BACKGROUND: PF-AES possess multiple properties improving targeted drug elution without the presence of polymers. Evaluation of long-term clinical performance of PF-AES versus latest generation permanent-polymer DES has not yet been performed in a large randomized trial introducing shortened dual-antiplatelet therapy. METHODS: In this physician-initiated, multicenter, randomized, all-comers trial, patients undergoing percutaneous coronary intervention with implantation of DES were enrolled. Patients were stratified for diabetes and troponin status and randomized to implantation of a permanent-polymer zotarolimus-eluting stent (PP-ZES) or a PF-AES. Dual-antiplatelet therapy duration was 12 months in troponin-positive patients and 1 month in troponin-negative patients. A noninferiority analysis was conducted to compare the 2 arms regarding target lesion failure (TLF) between 1 and 3 years. RESULTS: A total of 1,491 patients were randomized and treated. In this landmark analysis, between 1- and 3-year follow-up, TLF occurred in 35 patients (4.9%) in the PP-ZES arm and 37 PF-AES patients (5.1%). Clinical noninferiority of the PF-AES was confirmed, with a risk difference of 0.2% (upper limit 1-sided 95% CI: 2.2%; Pnoninferiority = 0.0031). CONCLUSIONS: ReCre8 (Randomized "All-Comer" Evaluation of a Permanent Polymer Resolute Integrity Stent Versus a Polymer Free Cre8 Stent) is the first randomized, multicenter trial with a head-to-head comparison of PP-ZES compared with PF-AES to investigate clinical outcomes of these new-generation DES in an all-comers population with long-term follow-up. On the basis of the present results, PF-AES are clinically noninferior to PP-ZES regarding TLF between 1 and 3 years. (Randomized "All-Comer" Evaluation of a Permanent Polymer Resolute Integrity Stent Versus a Polymer Free Cre8 Stent; NCT02328898).


Assuntos
Fármacos Cardiovasculares , Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Polímeros , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
15.
J Am Geriatr Soc ; 69(11): 3177-3185, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34612514

RESUMO

BACKGROUND: Postoperative delirium (POD) is a frequently observed complication after transcatheter aortic valve replacement (TAVR). The effects of intraoperative hypotension (IOH) on POD occurrence are currently unclear. METHODS: A retrospective observational cohort study of patients who underwent TAVR was conducted. We predefined IOH as area under the threshold (AUT) of five mean arterial blood pressures (MBP), varying from <100 to <60 mmHg. The AUT consisted of the combination of duration and depth under the MBP thresholds, expressed in mmHg*min. All MBP AUTs were computed based on the complete procedure, independent of procedural phase or duration. RESULTS: This cohort included 675 patients who underwent TAVR under general anesthesia (n = 128, 19%) or procedural sedation (n = 547, 81%). Delirium occurred mostly during the first 2 days after TAVR, and was observed in n = 93 (14%) cases. Furthermore, 674, 672, 663, 630, and 518 patients had at least 1 min intraoperative MBP <100, <90, <80, <70, and <60 mmHg, respectively. Patients who developed POD had higher AUT based on all five MBP thresholds during TAVR. The penalized adjusted odds ratio varied between 1.08 (99% confidence interval [CI] 0.74-1.56) for the AUT based on MBP < 100 mmHg and OR 1.06 (99% CI 0.88-1.28) for the AUT based on MBP < 60 mmHg. CONCLUSIONS: Intraoperative hypotension is frequently observed during TAVR, but not independently associated with POD after TAVR. Other potential factors than intraoperative hypotension may explain the occurrence of delirium after TAVR.


Assuntos
Anestesia Geral/efeitos adversos , Delírio/epidemiologia , Hipotensão/etiologia , Complicações Intraoperatórias/induzido quimicamente , Complicações Pós-Operatórias/induzido quimicamente , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Países Baixos , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
16.
Open Heart ; 8(2)2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34556561

RESUMO

OBJECTIVE: In recent years, transcatheter aortic valve implantation (TAVI) has become the treatment of choice for patients with symptomatic aortic valve stenosis considered to be at increased or high surgical risk. The aim of this study was to identify predictors of postoperative adverse events in older adults undergoing TAVI. METHODS: A prospective observational cohort study of patients who were referred to a geriatric outpatient clinic for a geriatric assessment prior to TAVI was conducted. The outcomes were mortality and hospital readmission within 3 months of TAVI and the occurrence of major postoperative complications during hospitalisation according to the Clavien-Dindo classification. These three outcomes were also combined to a composite outcome. Univariate and multivariate logistic regression analyses were performed to identify predictors of the outcomes and composite outcome of adverse events. RESULTS: This cohort included 490 patients who underwent TAVI (mean age 80.7±6.2 years, 47.3% male). Within 3 months of TAVI, 19 (3.9%) patients died and 46 (9.4%) patients experienced a hospital readmission. A total of 177 (36.1%) patients experienced one or more major complications according to the Clavien-Dindo classification during hospitalisation and 193 patients (39.4%) experienced the composite outcome of adverse events. In multivariate analyses, cognitive impairment was identified as an independent predictor of major postoperative complications (OR 2.16; 95% CI 1.14 to 4.19) and the composite outcome of adverse events (OR 2.40; 95% CI 1.21 to 4.79). No association was found between the other variables and the separate outcomes and composite outcome. CONCLUSION: Cognitive impairment is associated with postoperative adverse events in older patients undergoing TAVI. Therefore, it is important to screen for cognitive impairment prior to TAVI and it is recommended to include this in current TAVI guidelines.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Avaliação Geriátrica/métodos , Readmissão do Paciente/tendências , Complicações Pós-Operatórias/epidemiologia , Sistema de Registros , Medição de Risco/métodos , Idoso , Idoso de 80 Anos ou mais , Instituições de Assistência Ambulatorial/estatística & dados numéricos , Estenose da Valva Aórtica/mortalidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Estudos Prospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Fatores de Tempo , Substituição da Valva Aórtica Transcateter , Resultado do Tratamento
18.
J Invasive Cardiol ; 33(11): E863-E869, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34433695

RESUMO

OBJECTIVES: The PREVAIL study evaluated the safety and effectiveness of a paclitaxel-coated percutaneous transluminal coronary angioplasty balloon catheter for the treatment of coronary de novo and in-stent restenosis (ISR) lesions in patients with symptomatic ischemic heart disease. METHODS: PREVAIL was a prospective, multicenter, single-arm study that enrolled patients with clinical evidence of ischemia who had coronary lesions (de novo or first ISR) amenable to treatment with a drug-coated balloon (DCB). The study included 50 subjects (53 target lesions) who were treated with a Prevail DCB (Medtronic) during the index procedure and followed for 12 months. Mean lesion length was 14.5 ± 7.6 mm. The primary endpoint was in-stent (in-balloon) late lumen loss (LLL) by quantitative coronary angiography at 6 months post procedure. If the mean in-stent (in-balloon) LLL was less than the maximum acceptance rate of 0.50 mm at 6 months, then the study was considered successful. RESULTS: Mean in-stent (in-balloon) LLL was 0.05 ± 0.44 mm at 6 months post procedure. There were no deaths, myocardial infarctions, or stent (lesion) thrombosis events within 12 months. The incidence of clinically driven target-lesion revascularization was 6.0% at 12 months and clinically driven target-vessel revascularization was 10.0%. CONCLUSIONS: Paclitaxel DCB treatment of coronary de novo and first ISR lesions led to low LLL at 6 months and low rates of revascularization and safety events through 12 months.


Assuntos
Fármacos Cardiovasculares , Doença da Artéria Coronariana , Reestenose Coronária , Preparações Farmacêuticas , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Reestenose Coronária/diagnóstico , Reestenose Coronária/epidemiologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Humanos , Paclitaxel , Estudos Prospectivos , Resultado do Tratamento
19.
Int J Cardiol ; 337: 29-37, 2021 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-34029618

RESUMO

INTRODUCTION: Refractory angina (RA) is considered the end-stage of coronary artery disease, and often has no interventional treatment options. Coronary sinus Reducer (CSR) is a recent addition to the therapeutic arsenal, but its efficacy has only been evaluated on small populations. The RESOURCE registry provides further insights into this therapy. METHODS: The RESOURCE is an observational, retrospective registry that includes 658 patients with RA from 20 centers in Europe, United Kingdom and Israel. Prespecified endpoints were the amelioration of anginal symptoms evaluated with the Canadian Cardiovascular Society (CCS) score, the rates of procedural success and complications, and MACEs as composite of all-cause mortality, acute coronary syndromes, and stroke. RESULTS: At a median follow-up of 502 days (IQR 225-1091) after CSR implantation, 39.7% of patients improved by ≥2 CCS classes (primary endpoint), and 76% by ≥1 class. Procedural success was achieved in 96.7% of attempts, with 3% of procedures aborted mostly for unsuitable coronary sinus anatomy. Any complication occurred in 5.7% of procedures, but never required bailout surgery nor resulted in intra- or periprocedural death or myocardial infarction. One patient developed periprocedural stroke after inadvertent carotid artery puncture. At the last available follow-up, overall mortality and MACE were 10.4% and 14.6% respectively. At one, three and five years, mortality rate at Kaplan-Meier analysis was 4%, 13.7%, and 23.4% respectively. CONCLUSIONS: CSR implantation is safe and reduces angina in patients with refractory angina.


Assuntos
Seio Coronário , Canadá , Seio Coronário/diagnóstico por imagem , Seio Coronário/cirurgia , Europa (Continente)/epidemiologia , Humanos , Israel , Estudos Retrospectivos , Resultado do Tratamento , Reino Unido/epidemiologia
20.
Eur Heart J ; 42(27): 2670-2679, 2021 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-34000004

RESUMO

AIMS: The REFLECT I trial investigated the safety and effectiveness of the TriGuard™ HDH (TG) cerebral embolic deflection device in patients undergoing transcatheter aortic valve replacement (TAVR). METHODS AND RESULTS: This prospective, multicentre, single-blind, 2:1 randomized (TG vs. no TG) study aimed to enrol up to 375 patients, including up to 90 roll-in patients. The primary combined safety endpoint (VARC-2 defined early safety) at 30 days was compared with a performance goal. The primary efficacy endpoint was a hierarchical composite of (i) all-cause mortality or any stroke at 30 days, (ii) National Institutes of Health Stroke Scale (NIHSS) worsening at 2-5 days or Montreal Cognitive Assessment worsening at 30 days, and (iii) total volume of cerebral ischaemic lesions detected by diffusion-weighted magnetic resonance imaging at 2-5 days. Cumulative scores were compared between treatment groups using the Finkelstein-Schoenfeld method. A total of 258 of the planned, 375 patients (68.8%) were enrolled (54 roll-in and 204 randomized). The primary safety outcome was met compared with the performance goal (21.8% vs. 35%, P < 0.0001). The primary hierarchical efficacy endpoint was not met (mean efficacy score, higher is better: -5.3 ± 99.8 TG vs. 11.8 ± 96.4 control, P = 0.31). Covert central nervous system injury was numerically lower with TG both in-hospital (46.1% vs. 60.3%, P = 0.0698) and at 5 days (61.7 vs. 76.2%, P = 0.054) compared with controls. CONCLUSION: REFLECT I demonstrated that TG cerebral protection during TAVR was safe in comparison with historical TAVR data but did not meet the predefined effectiveness endpoint compared with unprotected TAVR controls.


Assuntos
Estenose da Valva Aórtica , Dispositivos de Proteção Embólica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Método Simples-Cego , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...