Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 87(11): 11E303, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910354

RESUMO

A prototype of a picosecond x-ray streak camera has been developed and tested by Commissariat à l'Énergie Atomique et aux Énergies Alternatives to provide plasma-diagnostic support for the Laser Megajoule. We report on the measured performance of this streak camera, which almost fulfills the requirements: 50-µm spatial resolution over a 15-mm field in the photocathode plane, 17-ps temporal resolution in a 2-ns timebase, a detection threshold lower than 625 nJ/cm2 in the 0.05-15 keV spectral range, and a dynamic range greater than 100.

2.
Rev Sci Instrum ; 87(3): 033706, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27036783

RESUMO

The Laser Megajoule (LMJ) facility located at CEA/CESTA started to operate in the early 2014 with two quadruplets (20 kJ at 351 nm) focused on target for the first experimental campaign. We present here the first set of gated x-ray imaging (GXI) diagnostics implemented on LMJ since mid-2014. This set consists of two imaging diagnostics with spatial, temporal, and broadband spectral resolution. These diagnostics will give basic measurements, during the entire life of the facility, such as position, structure, and balance of beams, but they will also be used to characterize gas filled target implosion symmetry and timing, to study x-ray radiography and hydrodynamic instabilities. The design requires a vulnerability approach, because components will operate in a harsh environment induced by neutron fluxes, gamma rays, debris, and shrapnel. Grazing incidence x-ray microscopes are fielded as far as possible away from the target to minimize potential damage and signal noise due to these sources. These imaging diagnostics incorporate microscopes with large source-to-optic distance and large size gated microchannel plate detectors. Microscopes include optics with grazing incidence mirrors, pinholes, and refractive lenses. Spatial, temporal, and spectral performances have been measured on x-ray tubes and UV lasers at CEA-DIF and at Physikalisch-Technische Bundesanstalt BESSY II synchrotron prior to be set on LMJ. GXI-1 and GXI-2 designs, metrology, and first experiments on LMJ are presented here.

3.
Rev Sci Instrum ; 85(11): 11D620, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430196

RESUMO

Commissariat à l'Énergie Atomique et aux Énergies Alternatives has developed the ARGOS X-ray framing camera to perform two-dimensional, high-timing resolution imaging of an imploding target on the French high-power laser facility Laser MegaJoule. The main features of this camera are: a microchannel plate gated X-ray detector, a spring-loaded CCD camera that maintains proximity focus in any orientation, and electronics packages that provide remotely-selectable high-voltages to modify the exposure-time of the camera. These components are integrated into an "air-box" that protects them from the harsh environmental conditions. A miniaturized X-ray generator is also part of the device for in situ self-testing purposes.

4.
Rev Sci Instrum ; 81(5): 053501, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20515133

RESUMO

The laser integration line (LIL) located at CEA-CESTA is equipped with x-ray plasma diagnostics using different kinds of x-ray components such as filters, mirrors, crystals, detectors, and cameras. The CEA-DAM of Arpajon is currently developing x-ray calibration methods and carrying out absolute calibration of LIL x-ray photodetectors. To guarantee LIL measurements, detectors such as x-ray cameras must be regularly calibrated close to the facility. A new x-ray facility is currently available to perform these absolute x-ray calibrations. This paper presents the x-ray tube based high energy x-ray source delivering x-ray energies ranging from 0.9 to 10 keV by means of an anode barrel. The purpose of this source is mainly to calibrate LIL x-ray cameras but it can also be used to measure x-ray filter transmission of plasma diagnostics. Different x-ray absolute calibrations such as x-ray streak and framing camera yields, x-ray charge-coupled device quantum efficiencies, and x-ray filter transmissions are presented in this paper. A x-ray flat photocathode detector sensitivity calibration recently performed for a CEA Z-pinch facility is also presented.

5.
Appl Radiat Isot ; 52(3): 649-55, 2000 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10724421

RESUMO

The use of liquid scintillation counting as a fundamental radionuclide standardisation method requires a correct description of the physical phenomena induced by the interaction of the ionising radiation with the liquid scintillator. In particular the standardisation of radionuclides decaying by electron capture as 55Fe and other electron-capture nuclides, requires the knowledge of total linear absorption coefficients of the liquid scintillator used for absolute activity measurement. Total linear absorption coefficient measurements have been undertaken using synchrotron radiation. Linear absorption coefficients of two widely used commercial liquid scintillators were measured in the 5.5-23 keV energy range. Small discrepancies were noted between theoretical and measured values of the Ultima-Gold mass attenuation coefficients for low energy photons.

6.
J Xray Sci Technol ; 8(3): 171-93, 1998 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-22388508

RESUMO

The concept of X-UV Lamellar Multilayer Amplitude Grating (LMAG) is introduced and a method of fabrication is given. Dynamical and kinematic theories of the diffraction by a LMAG are presented. Different applications of the LMAGs are considered. The first one is the achievement of a narrow bandpass multilayer monochromator for the X-UV domain. The second one is the reduction of specular background in the reflectivity curve of a multilayer structure. The third one is the polychromator system which allows one to split spatially and to perform a spectral sampling of a polychromatic beam. Finally we studied experimentally the behavior of an LMAG in conical mounting.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...