1.
Diabetes Technol Ther ; 17(1): 8-15, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25260047

RESUMO

BACKGROUND: This study evaluated the accuracy of Contour(®) Next (CN; Bayer HealthCare LLC, Diabetes Care, Whippany, NJ) compared with five blood glucose monitoring systems (BGMSs) across a wide range of clinically occurring blood glucose levels. SUBJECTS AND METHODS: Subjects (n=146) were ≥ 18 years and had type 1 or type 2 diabetes. Subjects' glucose levels were safely lowered or raised to provide a wide range of glucose values. Capillary blood samples were tested on six BGMSs and a YSI glucose analyzer (YSI Life Sciences, Inc., Yellow Springs, OH) as the reference. Extreme glucose values were achieved by glucose modification of the blood sample. System accuracy was assessed by mean absolute difference (MAD) and mean absolute relative difference (MARD) across several glucose ranges, with <70 mg/dL evaluated by MAD as the primary end point. RESULTS: In the low glucose range (<70 mg/dL), MAD values were as follows: Accu-Chek(®) Aviva Nano (Roche Diagnostics, Indianapolis, IN), 3.34 mg/dL; CN, 2.03 mg/dL; FreeStyle Lite(®) (FSL; Abbott Diabetes Care, Inc., Alameda, CA), 2.77 mg/dL; OneTouch(®) Ultra(®) 2 (LifeScan, Inc., Milpitas, CA), 10.20 mg/dL; OneTouch(®) Verio(®) Pro (LifeScan, Inc.), 4.53 mg/dL; and Truetrack(®) (Nipro Diagnostics, Inc., Fort Lauderdale, FL), 11.08 mg/dL. The lowest MAD in the low glucose range, from CN, was statistically significantly lower than those of the other BGMSs with the exception of the FSL. CN also had a statistically significantly lower MARD than all other BGMSs in the low glucose range. In the overall glucose range (21-496 mg/dL), CN yielded the lowest MAD and MARD values, which were statistically significantly lower in comparison with the other BGMSs. CONCLUSIONS: When compared with other BGMSs, CN demonstrated the lowest mean deviation from the reference value (by MAD and MARD) across multiple glucose ranges.


Assuntos
Automonitorização da Glicemia/instrumentação , Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 2/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Pesquisa Biomédica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Reprodutibilidade dos Testes , Adulto Jovem
2.
Curr Med Res Opin ; 30(9): 1795-802, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24889281

RESUMO

OBJECTIVE: To assess differences between estimated blood glucose values and those measured on a blood glucose meter and the impact on self-care behavior in type 2 diabetes. RESEARCH DESIGN AND METHODS: Subjects ≥18 years with type 2 diabetes (N = 297) attending a Taking Control of Your Diabetes conference were asked questions about diabetes management and to estimate their current blood glucose. Study staff tested subjects' blood glucose on a meter. After seeing the result, subjects were again asked questions on diabetes management. CLINICAL TRIAL REGISTRATION: NCT01453413. MAIN OUTCOME MEASURE: The percentage of subject blood glucose estimations that were outside ISO 15197:2003 accuracy criteria (>±15 mg/dL or >±20% of meter glucose values). RESULTS: Nearly half (46%) of subjects estimated blood glucose values outside ISO 15197:2003 accuracy criteria. Time since last blood glucose test, time since last meal, testing frequency, and A1C did not have an effect on differences between estimated blood glucose values and meter results. In the questionnaire before blood glucose testing, most subjects strongly agreed, agreed, or neither agreed nor disagreed that 'I make decisions about my diabetes, such as my food intake or my insulin dose even when I do not test my blood sugar' (71%) and 'My body tells me without testing if my blood sugar is low or high' (77%). After blood glucose testing, 99% of subjects strongly agreed, agreed, or neither agreed nor disagreed that 'Knowing my blood sugar by checking could help me make different diabetes decisions'. CONCLUSIONS: Self-monitoring of blood glucose is an important component of diabetes self-management. Testing rather than guessing blood glucose values is important to obtain accurate results and inform people with type 2 diabetes to make effective, appropriate diabetes management decisions. A potential limitation of this study is that the subject population may not be representative of the general population of people with diabetes; however, the conference setting may attract a more motivated population, which could underestimate the magnitude of the results.


Assuntos
Glicemia/análise , Diabetes Mellitus Tipo 2/sangue , Autocuidado , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/análise , Biomarcadores/sangue , Glicemia/metabolismo , Automonitorização da Glicemia/métodos , Congressos como Assunto , Diabetes Mellitus Tipo 2/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Autorrelato
3.
Diabetes Technol Ther ; 14(10): 851-7, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23013200

RESUMO

BACKGROUND: This study evaluated whether education and use of the advanced meter features of the CONTOUR(®) (Bayer HealthCare LLC, Diabetes Care, Tarrytown, NY) blood glucose monitoring system (BGMS) affect the frequency and pattern of blood glucose testing in insulin-using subjects with diabetes who routinely perform self-monitoring of blood glucose (SMBG). SUBJECTS AND METHODS: Insulin-using subjects with type 1 or type 2 diabetes were enrolled in this 6-month, multicenter, prospective study and randomized to one of two groups. The basic meter features group (BMF group) received basic instruction in the use of the BGMS, whereas the advanced meter features group (AMF group) also received training in the use of advanced features, including the meal marker and audible reminder, and were instructed to use these features. Both groups received education on the importance of postprandial testing. RESULTS: The AMF group (n=105) had significantly greater average weekly postprandial blood glucose testing than the BMF group (n=106) at each follow-up visit (P<0.001) and significantly increased the frequency of paired blood glucose testing (P<0.001) as well. In both groups, glycated hemoglobin decreased significantly as postprandial testing frequency increased (P<0.05). Subject reports indicated that use of advanced features made postmeal SMBG considerably easier to remember, helped them better understand how to make decisions on their own, and increased their confidence in meal choices. CONCLUSIONS: Study findings showed that advanced features of the CONTOUR BGMS increased structured testing as measured by postprandial and paired SMBG and were perceived as useful by patients.


Assuntos
Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 2/sangue , Comportamentos Relacionados com a Saúde , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Albuminúria/sangue , Glicemia/metabolismo , Automonitorização da Glicemia/estatística & dados numéricos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/epidemiologia , Diabetes Mellitus Tipo 2/tratamento farmacológico , Diabetes Mellitus Tipo 2/epidemiologia , Feminino , Seguimentos , Hemoglobinas Glicadas/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Cooperação do Paciente , Período Pós-Prandial , Estudos Prospectivos , Estados Unidos/epidemiologia , Adulto Jovem
4.
Diabetes Educ ; 37(1): 85-94, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21292622

RESUMO

PURPOSE: To evaluate self-monitoring of blood glucose (SMBG) information deficits, motivational obstacles, and behavioral skills limitations in individuals with type 1 and type 2 diabetes, and to assess the relationship of these deficits with SMBG frequency. METHODS: Individuals with type 1 (n = 208; 103 male, 105 female) and type 2 (n = 218; 107 male, 111 female) diabetes participated in an online survey assessing SMBG information, motivation, behavioral skills, and behavior. RESULTS: A substantial proportion of participants scored as SMBG uninformed, unmotivated, and unskilled on specific assessment items. SMBG information, motivation, and behavioral skills deficits were significantly correlated with SMBG frequency, such that individuals with type 1 or type 2 diabetes, who were less informed, less motivated, and less behaviorally skilled, reported lower frequency of SMBG. CONCLUSION: Common and consequential SMBG information, motivation, and behavioral skills deficits were present, and patients with these gaps were less likely to test frequently. Clinical education focusing on relevant SMBG information, motivation to act, and behavioral skills for acting effectively may be a priority.


Assuntos
Automonitorização da Glicemia/psicologia , Diabetes Mellitus Tipo 1/terapia , Diabetes Mellitus Tipo 2/terapia , Conhecimentos, Atitudes e Prática em Saúde , Cooperação do Paciente/psicologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Motivação , Educação de Pacientes como Assunto , Estados Unidos
5.
J Am Acad Audiol ; 20(5): 289-305, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19585959

RESUMO

PURPOSE: To investigate the clinical efficacy of linear frequency transposition (LFT) for a group of school-age children. RESEARCH DESIGN: A nonrandomized, within-subject design was implemented to investigate vowel and consonant recognition and fricative articulation of school-age children utilizing this feature. STUDY SAMPLE: Ten children, aged 6 years and 3 months, to 13 years and 6 months from a special education school district participated in this study. Individual hearing thresholds ranged from normal to moderate in the low frequencies and from severe to profound in the high frequencies. Average language age of children was within 2.2 years of chronological age. DATA COLLECTION AND ANALYSIS: Phoneme recognition and fricative articulation performance were compared for three conditions: (1) with the children's own hearing aids, (2) with an advanced hearing instrument utilizing LFT, and (3) with the same instrument without LFT. Nonsense syllable materials were administered at 30 and 50 dB HL input levels. Fricative articulation was measured by analyzing speech samples of conversational speech and oral reading passages. Repeated measures general linear model was utilized to determine the significance of any noted effects. RESULTS: Results indicated significant improvements in vowel and consonant recognition with LFT for the 30 dB HL input level. Significant improvement in the accuracy of production of high-frequency (HF) fricatives after six weeks of use of LFT was also observed. CONCLUSIONS: These results suggest that LFT is a potentially useful hearing aid feature for school-age children with a precipitous HF sensorineural hearing loss.


Assuntos
Auxiliares de Audição , Perda Auditiva Neurossensorial/fisiopatologia , Percepção da Fala/fisiologia , Medida da Produção da Fala/métodos , Adolescente , Audiometria de Tons Puros , Criança , Pré-Escolar , Perda Auditiva Neurossensorial/diagnóstico , Perda Auditiva Neurossensorial/reabilitação , Humanos , Lactente , Testes de Discriminação da Fala