Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 689
Filtrar
1.
Sci Adv ; 10(24): eadn5195, 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38865448

RESUMO

Anatomy-specific radio frequency receive coil arrays routinely adopted in magnetic resonance imaging (MRI) for signal acquisition are commonly burdened by their bulky, fixed, and rigid configurations, which may impose patient discomfort, bothersome positioning, and suboptimal sensitivity in certain situations. Herein, leveraging coaxial cables' inherent flexibility and electric field confining property, we present wireless, ultralightweight, coaxially shielded, passive detuning MRI coils achieving a signal-to-noise ratio comparable to or surpassing that of commercially available cutting-edge receive coil arrays with the potential for improved patient comfort, ease of implementation, and substantially reduced costs. The proposed coils demonstrate versatility by functioning both independently in form-fitting configurations, closely adapting to relatively small anatomical sites, and collectively by inductively coupling together as metamaterials, allowing for extension of the field of view of their coverage to encompass larger anatomical regions without compromising coil sensitivity. The wireless, coaxially shielded MRI coils reported herein pave the way toward next-generation MRI coils.


Assuntos
Imageamento por Ressonância Magnética , Tecnologia sem Fio , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/instrumentação , Tecnologia sem Fio/instrumentação , Humanos , Desenho de Equipamento , Razão Sinal-Ruído , Imagens de Fantasmas
2.
Proc Natl Acad Sci U S A ; 121(25): e2318838121, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38870057

RESUMO

Hertwig's rule states that cells divide along their longest axis, usually driven by forces acting on the mitotic spindle. Here, we show that in contrast to this rule, microtubule-based pulling forces in early Caenorhabditis elegans embryos align the spindle with the short axis of the cell. We combine theory with experiments to reveal that in order to correct this misalignment, inward forces generated by the constricting cytokinetic ring rotate the entire cell until the spindle is aligned with the cell's long axis. Experiments with slightly compressed mouse zygotes indicate that this cytokinetic ring-driven mechanism of ensuring Hertwig's rule is general for cells capable of rotating inside a confining shell, a scenario that applies to early cell divisions of many systems.


Assuntos
Caenorhabditis elegans , Fuso Acromático , Animais , Caenorhabditis elegans/embriologia , Camundongos , Fuso Acromático/metabolismo , Microtúbulos/metabolismo , Citocinese/fisiologia , Rotação , Zigoto/metabolismo , Zigoto/citologia , Zigoto/crescimento & desenvolvimento , Embrião não Mamífero/citologia , Desenvolvimento Embrionário/fisiologia , Modelos Biológicos
3.
Life Sci Alliance ; 7(8)2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38760174

RESUMO

Amyotrophic lateral sclerosis (ALS) leads to death within 2-5 yr. Currently, available drugs only slightly prolong survival. We present novel insights into the pathophysiology of Superoxide Dismutase 1 (SOD1)- and in particular Fused In Sarcoma (FUS)-ALS by revealing a supposedly central role of glycolic acid (GA) and D-lactic acid (DL)-both putative products of the Parkinson's disease associated glyoxylase DJ-1. Combined, not single, treatment with GA/DL restored axonal organelle phenotypes of mitochondria and lysosomes in FUS- and SOD1-ALS patient-derived motoneurons (MNs). This was not only accompanied by restoration of mitochondrial membrane potential but even dependent on it. Despite presenting an axonal transport deficiency as well, TDP43 patient-derived MNs did not share mitochondrial depolarization and did not respond to GA/DL treatment. GA and DL also restored cytoplasmic mislocalization of FUS and FUS recruitment to DNA damage sites, recently reported being upstream of the mitochondrial phenotypes in FUS-ALS. Whereas these data point towards the necessity of individualized (gene-) specific therapy stratification, it also suggests common therapeutic targets across different neurodegenerative diseases characterized by mitochondrial depolarization.


Assuntos
Esclerose Lateral Amiotrófica , Glicolatos , Ácido Láctico , Mitocôndrias , Proteína Desglicase DJ-1 , Proteína FUS de Ligação a RNA , Superóxido Dismutase-1 , Humanos , Esclerose Lateral Amiotrófica/metabolismo , Esclerose Lateral Amiotrófica/genética , Proteína FUS de Ligação a RNA/metabolismo , Proteína FUS de Ligação a RNA/genética , Glicolatos/metabolismo , Glicolatos/farmacologia , Mitocôndrias/metabolismo , Proteína Desglicase DJ-1/metabolismo , Proteína Desglicase DJ-1/genética , Ácido Láctico/metabolismo , Superóxido Dismutase-1/metabolismo , Superóxido Dismutase-1/genética , Potencial da Membrana Mitocondrial , Neurônios Motores/metabolismo , Lisossomos/metabolismo
4.
Wien Klin Wochenschr ; 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38653873

RESUMO

BACKGROUND: External quality assessment (EQA) schemes provide objective feedback to participating laboratories about the performance of their analytical systems and information about overall regional analytical performance. The EQAs are particularly important during pandemics as they also assess the reliability of individual test results and show opportunities to improve test strategies. With the end of the COVID-19 pandemic, the testing frequency significantly decreased in Austria. Here, we analyzed whether this decrease had an effect on participation and/or performance in SARS-CoV­2 virus detection EQAs, as compared to the pandemic era. MATERIAL AND METHODS: Identical samples were sent to all participating laboratories, and the EQA provider evaluated the agreement of the reported results with defined targets. The EQA was operated under two schemes with identical samples and therefore we analyzed it as a single EQA round. The performance of testing was reported as true positive ratios, comparing the post-pandemic data to previous rounds. Furthermore, subgroups of participants were analyzed stratified by laboratory type (medical or nonmedical) and the test system format (fully automated or requiring manual steps). RESULTS: While the frequency of false negative results per sample did not change during the 3 years of the pandemic (5.7%, 95% confidence interval [CI] 3.1-8.4%), an average per sample false negative ratio of 4.3% was observed in the first post-pandemic EQA (0%, 1.8%, and 11% for the 3 positive samples included in the test panel, n = 109 test results per sample). In this first post-pandemic EQA medical laboratories (average 0.4% false negative across 3 samples, n = 90) and automated test systems (average 1.2% false negative, n = 261) had lower false negative ratios than nonmedical laboratories (22.8%, n = 19) and manual test systems (16.7%, n = 22). These lower average ratios were due to a low concentration sample, where nonmedical laboratories reported 36.8% and manual test systems 54.5% true positive results. CONCLUSION: Overall ratios of true positive results were below the mean of all results during the pandemic but were similar to the first round of the pandemic. A lower post-pandemic true positive ratio was associated with specific laboratory types and assay formats, particularly for samples with low concentration. The EQAs will continue to monitor the laboratory performance to ensure the same quality of epidemiological data after the pandemic, even if vigilance has decreased.

5.
Adv Sci (Weinh) ; 11(26): e2400261, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38659228

RESUMO

Metamaterials hold significant promise for enhancing the imaging capabilities of magnetic resonance imaging (MRI) machines as an additive technology, due to their unique ability to enhance local magnetic fields. However, despite their potential, the metamaterials reported in the context of MRI applications have often been impractical. This impracticality arises from their predominantly flat configurations and their susceptibility to shifts in resonance frequencies, preventing them from realizing their optimal performance. Here, a computational method for designing wearable and tunable metamaterials via freeform auxetics is introduced. The proposed computational-design tools yield an approach to solving the complex circle packing problems in an interactive and efficient manner, thus facilitating the development of deployable metamaterials configured in freeform shapes. With such tools, the developed metamaterials may readily conform to a patient's knee, ankle, head, or any part of the body in need of imaging, and while ensuring an optimal resonance frequency, thereby paving the way for the widespread adoption of metamaterials in clinical MRI applications.

6.
Adv Mater ; : e2313692, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38569592

RESUMO

Recent advancements in metamaterials have yielded the possibility of a wireless solution to improve signal-to-noise ratio (SNR) in magnetic resonance imaging (MRI). Unlike traditional closely packed local coil arrays with rigid designs and numerous components, these lightweight, cost-effective metamaterials eliminate the need for radio frequency cabling, baluns, adapters, and interfaces. However, their clinical adoption is limited by their low sensitivity, bulky physical footprint, and limited, specific use cases. Herein, a wearable metamaterial developed using commercially available coaxial cable, designed for a 3.0 T MRI system is introduced. This metamaterial inherits the coaxially-shielded structure of its constituent cable, confining the electric field within and mitigating coupling to its surroundings. This ensures safer clinical adoption, lower signal loss, and resistance to frequency shifts. Weighing only 50 g, the metamaterial maximizes its sensitivity by conforming to the anatomical region of interest. MRI images acquired using this metamaterial with various pulse sequences achieve an SNR comparable or even surpass that of a state-of-the-art 16-channel knee coil. This work introduces a novel paradigm for constructing metamaterials in the MRI environment, paving the way for the development of next-generation wireless MRI technology.

7.
Front Mol Biosci ; 11: 1327699, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38375507

RESUMO

Introduction: A notable feature of the 2019 coronavirus disease (COVID-19) pandemic was the widespread use of whole genome sequencing (WGS) to monitor severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infections. Countries around the world relied on sequencing and other forms of variant detection to perform contact tracing and monitor changes in the virus genome, in the hopes that epidemic waves caused by variants would be detected and managed earlier. As sequencing was encouraged and rewarded by the government in Austria, but represented a new technicque for many laboratories, we designed an external quality assessment (EQA) scheme to monitor the accuracy of WGS and assist laboratories in validating their methods. Methods: We implemented SARS-CoV-2 WGS EQAs in Austria and report the results from 7 participants over 5 rounds from February 2021 until June 2023. The participants received sample material, sequenced genomes with routine methods, and provided the sequences as well as information about mutations and lineages. Participants were evaluated on the completeness and accuracy of the submitted sequence and the ability to analyze and interpret sequencing data. Results: The results indicate that performance was excellent with few exceptions, and these exceptions showed improvement over time. We extend our findings to infer that most publicly available sequences are accurate within ≤1 nucleotide, somewhat randomly distributed through the genome. Conclusion: WGS continues to be used for SARS-CoV-2 surveillance, and will likely be instrumental in future outbreak scenarios. We identified hurdles in building next-generation sequencing capacity in diagnostic laboratories. EQAs will help individual laboratories maintain high quality next-generation sequencing output, and strengthen variant monitoring and molecular epidemiology efforts.

8.
ArXiv ; 2023 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-38045478

RESUMO

Metamaterials hold significant promise for enhancing the imaging capabilities of MRI machines as an additive technology, due to their unique ability to enhance local magnetic fields. However, despite their potential, the metamaterials reported in the context of MRI applications have often been impractical. This impracticality arises from their predominantly flat configurations and their susceptibility to shifts in resonance frequencies, preventing them from realizing their optimal performance. Here, we introduce a computational method for designing wearable and tunable metamaterials via freeform auxetics. The proposed computational-design tools yield an approach to solving the complex circle packing problems in an interactive and efficient manner, thus facilitating the development of deployable metamaterials configured in freeform shapes. With such tools, the developed metamaterials may readily conform to a patient's kneecap, ankle, head, or any part of the body in need of imaging, and while ensuring an optimal resonance frequency, thereby paving the way for the widespread adoption of metamaterials in clinical MRI applications.

9.
J Med Virol ; 95(11): e29245, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-38009693

RESUMO

Arthropod-borne flaviviruses include a number of medically relevant human pathogens such as the mosquito-borne dengue (DEN), Zika, and yellow fever (YF) viruses as well as tick-borne encephalitis virus (TBEV). All flaviviruses are antigenically related and anamnestic responses due to prior immunity can modulate antibody specificities in subsequent infections or vaccinations. In our study, we analyzed the induction of broadly flavivirus cross-reactive antibodies in tick-borne encephalitis (TBE) and DEN patients without or with prior flavivirus exposure through TBE and/or YF vaccination, and determined the contribution of these antibodies to TBE and dengue virus (DENV) neutralization. In addition, we investigated the formation of cross-reactive antibodies in TBE-vaccination breakthroughs (VBTs). A TBEV infection without prior YF or TBE vaccination induced predominantly type-specific antibodies. In contrast, high levels of broadly cross-reactive antibodies were found in samples from TBE patients prevaccinated against YF as well as in DEN patients prevaccinated against TBE and/or YF. While these cross-reactive antibodies did not neutralize TBEV, they were effective in neutralizing DENV. This discrepancy points to structural differences between the two viruses and indicates that broadly cross-reactive epitopes are less accessible in TBEV than in DENV. In TBE VBT infections, type-specific antibodies dominated the antibody response, thus revealing no difference from that of unvaccinated TBE patients. Our results emphasize significant differences in the structural properties of different flaviviruses that have an impact on the induction of broadly cross-reactive antibodies and their functional activities in virus neutralization.


Assuntos
Dengue , Vírus da Encefalite Transmitidos por Carrapatos , Encefalite Transmitida por Carrapatos , Infecções por Flavivirus , Infecção por Zika virus , Zika virus , Animais , Humanos , Encefalite Transmitida por Carrapatos/prevenção & controle , Formação de Anticorpos , Anticorpos Antivirais , Infecções por Flavivirus/prevenção & controle , Vacinação , Dengue/prevenção & controle
10.
Curr Biol ; 33(23): 5096-5108.e15, 2023 12 04.
Artigo em Inglês | MEDLINE | ID: mdl-37979577

RESUMO

Embryos develop in a surrounding that guides key aspects of their development. For example, the anteroposterior (AP) body axis is always aligned with the geometric long axis of the surrounding eggshell in fruit flies and worms. The mechanisms that ensure convergence of the AP axis with the long axis of the eggshell remain unresolved. We investigate axis convergence in early C. elegans development, where the nascent AP axis, when misaligned, actively re-aligns to converge with the long axis of the egg. We identify two physical mechanisms that underlie axis convergence. First, bulk cytoplasmic flows, driven by actomyosin cortical flows, can directly reposition the AP axis. Second, active forces generated within the pseudocleavage furrow, a transient actomyosin structure similar to a contractile ring, can drive a mechanical re-orientation such that it becomes positioned perpendicular to the long axis of the egg. This in turn ensures AP axis convergence. Numerical simulations, together with experiments that either abolish the pseudocleavage furrow or change the shape of the egg, demonstrate that the pseudocleavage-furrow-dependent mechanism is a major driver of axis convergence. We conclude that active force generation within the actomyosin cortical layer drives axis convergence in the early nematode.


Assuntos
Proteínas de Caenorhabditis elegans , Caenorhabditis elegans , Animais , Actomiosina , Desenvolvimento Embrionário , Drosophila , Citoesqueleto de Actina , Embrião não Mamífero
11.
Lancet Microbe ; 4(12): e1015-e1023, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37979591

RESUMO

BACKGROUND: The aim of external quality assessment (EQA) schemes is to evaluate the analytical performance of laboratories and test systems in a near-to-real-life setting. This monitoring service provides feedback to participant laboratories and serves as a control measure for the epidemiological assessment of the regional incidence of a pathogen, particularly during epidemics. Using data from EQA schemes implemented as a result of the intensive effort to monitor SARS-CoV-2 infections in Austria, we aimed to identify factors that explained the variation in laboratory performance for SARS-CoV-2 detection over the course of the COVID-19 pandemic. METHODS: For this observational study, we retrospectively analysed 6308 reverse transcriptase quantitative PCR (RT-qPCR) test results reported by 191 laboratories on 71 samples during 14 rounds of three SARS-CoV-2 pathogen detection EQA schemes in Austria between May 18, 2020, and Feb 20, 2023. We calculated the overall rates of false and true-negative, false and true-positive, and inconclusive results. We then assessed laboratory performance by estimating the sensitivity by testing whether significant variation in the odds of obtaining a true-positive result could be explained by virus concentration, laboratory type, or assay format. We also assessed whether laboratory performance changed over time. FINDINGS: 4371 (93·7%) of 4663 qPCR test results were true-positive, 241 (5·2%) were false-negative, and 51 (1·1%) were inconclusive. The mean per-sample sensitivity was 99·7% in samples with high virus concentrations (1383 [99·4%] true-positive, three [0·2%] false-negative, and five [0·4%] inconclusive results for 1391 tests in which the sample cycle threshold was ≤32), whereas detection rates were lower in samples with low virus concentrations (mean per-sample sensitivity 92·5%; 2988 [91·3%] true-positive, 238 [7·3%] false-negative, and 46 [1·4%] inconclusive results for 3272 tests in which the cycle threshold was >32). Of the 1645 results expected to be negative, 1561 (94·9%) were correctly reported as negative, 10 (0·6%) were incorrectly reported as positive, and 74 (4·5%) were reported as inconclusive. Notably, the overall performance of the tests did not change significantly over time. The odds of reporting a correct result were 2·94 (95% CI 1·75-4·96) times higher for a medical laboratory than for a non-medical laboratory, and 4·60 (2·91-7·41) times greater for automated test systems than for manual test systems. Automated test systems within medical laboratories had the highest sensitivity when compared with systems requiring manual intervention in both medical and non-medical laboratories. INTERPRETATION: High rates of false-negativity in all PCR analyses evaluated in comprehensive, multiple, and repeated EQA schemes outline a clear path for improvement in the future. The performance of some laboratories (eg, non-medical laboratories or those using non-automated test systems) should receive additional scrutiny-for example, by requiring additional EQA schemes for certification or accreditation-if the aggregated data from EQA rounds suggest lower sensitivity than that recorded by others. This strategy will provide assurances that epidemiological data as a whole are reliable when testing on such a large scale. Although performance did not improve over time, we cannot exclude extenuating circumstances-such as shortages and weakened supply chains-that could have prevented laboratories from seeking alternative methods to improve performance. FUNDING: None.


Assuntos
COVID-19 , Ácidos Nucleicos , Humanos , COVID-19/diagnóstico , COVID-19/epidemiologia , SARS-CoV-2/genética , Estudos Retrospectivos , Pandemias , Áustria/epidemiologia
12.
Front Radiol ; 3: 1186277, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37789953

RESUMO

Background: Hematocrit and lactate have an established role in trauma as indicators of bleeding and cell death, respectively. The wide availability of CT imaging and clinical data poses the question of how these can be used in combination to predict outcomes. Purpose: To assess the utility of hematocrit or lactate trends in predicting intensive care unit (ICU) admission and hospital length of stay (LOS) in patients with torso trauma combined with clinical parameters and injury findings on CT. Materials and Methods: This was a single-center retrospective study of adults with torso trauma in one year. Trends were defined as a unit change per hour. CT findings and clinical parameters were explanatory variables. Outcomes were ICU admission and hospital LOS. Multivariate logistic and negative binomial regression models were used to calculate the odds ratio (OR) and incident rate ratio (IRR). Results: Among 840 patients, 561 (72% males, age 39 ± 18) were included, and 168 patients (30%) were admitted to the ICU. Decreasing hematocrit trend [OR 2.54 (1.41-4.58), p = 0.002] and increasing lactate trend [OR 3.85 (1.35-11.01), p = 0.012] were associated with increased odds of ICU admission. LOS median was 2 (IQR: 1-5) days. Decreasing hematocrit trend [IRR 1.37 (1.13-1.66), p = 0.002] and increasing lactate trend [2.02 (1.43-2.85), p < 0.001] were associated with longer hospital LOS. Conclusion: Hematocrit and lactate trends may be helpful in predicting ICU admission and LOS in torso trauma independent of organ injuries on CT, age, or admission clinical parameters.

13.
Front Radiol ; 3: 1187449, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37810756

RESUMO

Purpose: The purpose of this study is to utilize a two-material decomposition to quantify bone marrow edema on a dual-energy computed tomography (DECT) scanner at the cervical, thoracic, and lumbar spine acute fractures in correlation with short tau inversion recovery (STIR) hyperintensity on magnetic resonance imaging (MRI) in comparison with the normal bone marrow. Materials and methods: This retrospective institutional review board-approved study gathered patients over 18 years old who had acute cervical, thoracic, or lumbar spinal fractures scanned on a DECT scanner. Those who had a spinal MRI done with bone marrow STIR hyperintensity within 3 weeks of the DECT were included. The water (calcium) and fat (calcium) density (mg/cm3) measurements of the region of interest of the bone marrow were obtained at a normal anatomic equivalent site and at the fracture site where STIR hyperintensity was noted on MRI. A statistical analysis was performed using the paired t-test and Wilcoxon signed rank test (p > 0.05). Results: A total of 20 patients met the inclusion criteria (males n = 17 males, females n = 3). A total of 32 fractures were analyzed: 19 cervical and 13 thoracolumbar. There were statistically significant differences in the water (43 ± 24 mg/cm3) and fat (36 ± 31 mg/cm3) density (mg/cm3) at the acute thoracic and lumbar spine fractures in correlation with edema on STIR images (both paired t-test <0.001, both Wilcoxon signed ranked test p < 0.01). There were no significant differences in the water (-10 ± 46 mg/cm3) or fat (+7 ± 50 mg/cm3) density (mg/cm3) at the cervical spine fractures. Conclusion: The DECT two-material decomposition using water (calcium) and fat (calcium) analyses has the ability to quantify a bone marrow edema at the acute fracture site in the thoracic and lumbar spine.

14.
Cell Biosci ; 13(1): 155, 2023 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-37635256

RESUMO

BACKGROUND: Pain in early life may impact on development and risk of chronic pain. We developed an optogenetic Cre/loxP mouse model of "early-life-pain" (ELP) using mice with transgenic expression of channelrhodopsin-2 (ChR2) under control of the Advillin (Avil) promoter, which drives expression of transgenes predominantly in isolectin B4 positive non-peptidergic nociceptors in postnatal mice. Avil-ChR2 (Cre +) and ChR2-flfl control mice were exposed to blue light in a chamber once daily from P1-P5 together with their Cre-negative mother. RESULTS: ELP caused cortical hyperexcitability at P8-9 as assessed via multi-electrode array recordings that coincided with reduced expression of synaptic genes (RNAseq) including Grin2b, neurexins, piccolo and voltage gated calcium and sodium channels. Young adult (8-16 wks) Avil-ChR2 mice presented with nociceptive hypersensitivity upon heat or mechanical stimulation, which did not resolve up until one year of age. The persistent hypersensitivy to nociceptive stimuli was reflected by increased calcium fluxes in primary sensory neurons of aged mice (1 year) upon capsaicin stimulation. Avil-ChR2 mice behaved like controls in maze tests of anxiety, social interaction, and spatial memory but IntelliCage behavioral studies revealed repetitive nosepokes and corner visits and compulsive lickings. Compulsiveness at the behavioral level was associated with a reduction of sphingomyelin species in brain and plasma lipidomic studies. Behavioral studies were done with female mice. CONCLUSION: The results suggest that ELP may predispose to chronic "pain" and compulsive psychopathology in part mediated by alterations of sphingolipid metabolism, which have been previously described in the context of addiction and psychiatric diseases.

15.
Open Biol ; 13(8): 230063, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37528732

RESUMO

Dendritic spines are crucial for excitatory synaptic transmission as the size of a spine head correlates with the strength of its synapse. The distribution of spine head sizes follows a lognormal-like distribution with more small spines than large ones. We analysed the impact of synaptic activity and plasticity on the spine size distribution in adult-born hippocampal granule cells from rats with induced homo- and heterosynaptic long-term plasticity in vivo and CA1 pyramidal cells from Munc13-1/Munc13-2 knockout mice with completely blocked synaptic transmission. Neither the induction of extrinsic synaptic plasticity nor the blockage of presynaptic activity degrades the lognormal-like distribution but changes its mean, variance and skewness. The skewed distribution develops early in the life of the neuron. Our findings and their computational modelling support the idea that intrinsic synaptic plasticity is sufficient for the generation, while a combination of intrinsic and extrinsic synaptic plasticity maintains lognormal-like distribution of spines.


Assuntos
Plasticidade Neuronal , Neurônios , Camundongos , Ratos , Animais , Plasticidade Neuronal/fisiologia , Neurônios/fisiologia , Células Piramidais/metabolismo , Espinhas Dendríticas/metabolismo , Transmissão Sináptica/fisiologia , Sinapses/fisiologia , Neurogênese
16.
Sci Rep ; 13(1): 12527, 2023 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-37532743

RESUMO

A central goal of modern magnetic resonance imaging (MRI) is to reduce the time required to produce high-quality images. Efforts have included hardware and software innovations such as parallel imaging, compressed sensing, and deep learning-based reconstruction. Here, we propose and demonstrate a Bayesian method to build statistical libraries of magnetic resonance (MR) images in k-space and use these libraries to identify optimal subsampling paths and reconstruction processes. Specifically, we compute a multivariate normal distribution based upon Gaussian processes using a publicly available library of T1-weighted images of healthy brains. We combine this library with physics-informed envelope functions to only retain meaningful correlations in k-space. This covariance function is then used to select a series of ring-shaped subsampling paths using Bayesian optimization such that they optimally explore space while remaining practically realizable in commercial MRI systems. Combining optimized subsampling paths found for a range of images, we compute a generalized sampling path that, when used for novel images, produces superlative structural similarity and error in comparison to previously reported reconstruction processes (i.e. 96.3% structural similarity and < 0.003 normalized mean squared error from sampling only 12.5% of the k-space data). Finally, we use this reconstruction process on pathological data without retraining to show that reconstructed images are clinically useful for stroke identification. Since the model trained on images of healthy brains could be directly used for predictions in pathological brains without retraining, it shows the inherent transferability of this approach and opens doors to its widespread use.

17.
J Phys Chem C Nanomater Interfaces ; 127(29): 14303-14316, 2023 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-37529664

RESUMO

Rare earth oxyhydrides REOxH(3-2x), with RE = Y, Sc, or Gd and a cationic FCC lattice, are reversibly photochromic in nature. It is known that structural details and anion (O2-:H-) composition dictate the efficiency of the photochromic behavior. The mechanism behind the photochromism is, however, not yet understood. In this study, we use 1H, 2H, 17O, and 89Y solid-state NMR spectroscopy and density functional theory (DFT) calculations to study the various yttrium, hydrogen, and oxygen local environments, anion oxidation states, and hydride ion dynamics. DFT models of YOxH(3-2x) with both anion-ordered and anion-disordered sublattices are constructed for a range of compositions and show a good correlation with the experimental NMR parameters. Two-dimensional 17O-1H and 89Y-1H NMR correlation experiments reveal heterogeneities in the samples, which appear to consist of hydride-rich (x ≈ 0.25) and hydride-poor domains (x ≈ 1) rather than a single composition with homogeneous anion mixing. The compositional variation (as indicated by the different x values in YOxH(3-2x)) is determined by comparing static 1H NMR line widths with calculated 1H-1H dipolar couplings of yttrium oxyhydride models. The 1D 17O MAS spectrum demonstrates the presence of a small percentage of hydroxide (OH-) ions. DFT modeling indicates a reaction between the protons of hydroxides and hydrides to form molecular hydrogen (H+ + H- → H2). 1H MAS NMR indicates the presence of a mobile component that, based on this finding, is attributed to trapped molecular H2 in the lattice.

18.
NPJ Vaccines ; 8(1): 110, 2023 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-37542025

RESUMO

We report SARS-CoV-2 neutralizing antibody titers in sera of triple-vaccinated individuals who received a booster dose of an original monovalent or a bivalent BA.1- or BA.4/BA.5-adapted vaccine or had a breakthrough infection with Omicron variants BA.1, BA.2 or BA.4/BA.5. A bivalent BA.4/BA.5 booster or Omicron-breakthrough infection induced increased Omicron-neutralization titers compared with the monovalent booster. The XBB.1.5 variant effectively evaded neutralizing-antibody responses elicited by current vaccines and/or infection with previous variants.

19.
JACC Heart Fail ; 11(10): 1351-1362, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37480877

RESUMO

BACKGROUND: Atrial fibrillation (AF) is a common comorbidity in patients with heart failure with preserved ejection fraction (HFpEF) and in heart failure with mildly reduced ejection fraction (HFmrEF). OBJECTIVES: This study sought to describe AF burden and its clinical impact among individuals with HFpEF and HFmrEF who participated in a randomized clinical trial of atrial shunt therapy (REDUCE LAP-HF II [A Study to Evaluate the Corvia Medical, Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients with Heart Failure]) and to evaluate the effect of atrial shunt therapy on AF burden. METHODS: Study investigators characterized AF burden among patients in the REDUCE LAP-HF II trial by using ambulatory cardiac patch monitoring at baseline (median patch wear time, 6 days) and over a 12-month follow-up (median patch wear time, 125 days). The investigators determined the association of baseline AF burden with long-term clinical events and examined the effect of atrial shunt therapy on AF burden over time. RESULTS: Among 367 patients with cardiac monitoring data at baseline and follow-up, 194 (53%) had a history of AF or atrial flutter (AFL), and median baseline AF burden was 0.012% (IQR: 0%-1.3%). After multivariable adjustment, baseline AF burden ≥0.012% was significantly associated with heart failure (HF) events (HR: 2.00; 95% CI: 1.17-3.44; P = 0.01) both with and without a history of AF or AFL (P for interaction = 0.68). Adjustment for left atrial reservoir strain attenuated the baseline AF burden-HF event association (HR: 1.71; 95% CI: 0.93-3.14; P = 0.08). Of the 367 patients, 141 (38%) had patch-detected AF during follow-up without a history of AF or AFL. Atrial shunt therapy did not change AF incidence or burden during follow-up. CONCLUSIONS: In HFpEF and HFmrEF, nearly 40% of patients have subclinical AF by 1 year. Baseline AF burden, even at low levels, is associated with HF events. Atrial shunt therapy does not affect AF incidence or burden. (A Study to Evaluate the Corvia Medical, Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients with Heart Failure [REDUCE LAP-HF II]; NCT03088033).


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Humanos , Fibrilação Atrial/epidemiologia , Volume Sistólico , Átrios do Coração , Implantação de Prótese , Prognóstico
20.
J Med Virol ; 95(6): e28830, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37282809

RESUMO

In 2022, Austria experienced a severe respiratory syncytial virus (RSV) epidemic with an earlier-than-usual start (Weeks 35/2021-45/2022) and increased numbers of pediatric patients in emergency departments. This surge came 2 years after a season with no cases detected as a result of coronavirus disease 2019 nonpharmaceutical interventions. We analyzed epidemiologic patterns and the phylodynamics of RSV based on approximately 30 800 respiratory specimens collected year-round over 10 years from ambulatory and hospitalized patients from 248 locations in Austria. Genomic surveillance and phylogenetic analysis of 186 RSV-A and 187 RSV-B partial glycoprotein sequences collected from 2018 to 2022 revealed that the 2022/2023 surge was driven by RSV-B in contrast to the surge in the 2021/2022 season that was driven by RSV-A. Whole-genome sequencing and phylodynamic analysis indicated that the RSV-B strain GB5.0.6a was the predominant genotype in the 2022/2023 season and emerged in late 2019. The results provide insight into RSV evolution and epidemiology that will be applicable to future monitoring efforts with the advent of novel vaccines and therapeutics.


Assuntos
COVID-19 , Infecções por Vírus Respiratório Sincicial , Vírus Sinciciais Respiratórios , Criança , Humanos , Áustria/epidemiologia , COVID-19/epidemiologia , Monitoramento Epidemiológico , Evolução Molecular , Técnicas de Genotipagem , Epidemiologia Molecular , Filogenia , Infecções por Vírus Respiratório Sincicial/epidemiologia , Infecções por Vírus Respiratório Sincicial/virologia , Vírus Sinciciais Respiratórios/classificação , Vírus Sinciciais Respiratórios/genética , Vírus Sinciciais Respiratórios/isolamento & purificação , Sequenciamento Completo do Genoma
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...