Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Psychol ; 79(1): 201-209, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35751901

RESUMO

AIMS: This exploratory pilot study (N = 3 sessions, 793 speech units) used task analysis to refine an early model of the attachment task in attachment-based family therapy (ABFT). The attachment task aims to repair long-standing parent-adolescent relational ruptures that inhibit parents from being a resource for adolescents recovering from depression and/or suicidality. METHODS: Video recordings of three attachment task sessions with strong adherence to the model were selected for intensive study. Two sessions were rated as successful (i.e., attachment was repaired) and one as unsuccessful (i.e., attachment repair did not occur). Sessions were then coded using Structural Analysis of Social Behavior (SASB). RESULTS: The current SASB analysis provided empirical support for our previous clinical impression that the task involves three parts: (I) adolescent disclosure of attachment rupture, (II) parent disclosure, and (III) a more mutual conversation. SASB also provided insights into more subtle elements of the model. CONCLUSION: Successful attachment sessions were associated with high parent affiliation and autonomy-both while affirming the adolescent's story and when disclosing their own experience. Unsuccessful task attempts were associated with parental enmeshment and hostile belittling, blaming, and distancing. An enhanced model of ideal parent behaviors during the attachment task is offered, including space for parent disclosure-perhaps even apology-that is both warm and independent, leading to a more mutual parent-adolescent conversation. Clinically, the findings support the importance of the therapist focusing on the process and quality of parent-child interactions to facilitate attachment repair.


Assuntos
Apego ao Objeto , Relações Pais-Filho , Adolescente , Humanos , Projetos Piloto , Terapia Familiar , Pais
2.
J Am Coll Cardiol ; 52(7): 541-50, 2008 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-18687248

RESUMO

OBJECTIVES: Our purpose was to demonstrate that strategically chosen implantable cardioverter-defibrillator (ICD) ventricular tachycardia (VT) or ventricular fibrillation (VF) detection and therapy parameters can reduce the combined incidence of device-delivered shocks, arrhythmic syncope, and untreated sustained symptomatic VT/VF (morbidity index). BACKGROUND: Strategically chosen ICD VT/VF detection and therapy parameters have been shown in previous studies to reduce the number of shocked episodes. In the PREPARE (Primary Prevention Parameters Evaluation) study, these prior strategies were combined with additional strategies specific to primary prevention patients. METHODS: The PREPARE study was a prospective, cohort-controlled study that analyzed 700 patients (biventricular [Bi-V] ICD and non-Bi-V ICD) with primary prevention indications for an ICD from 38 centers followed for 1 year. VT/VF was detected for rates > or =182 beats/min that were maintained for at least 30 of 40 beats. Antitachycardia pacing was programmed as the first therapy for regular rhythms with rates of 182 to 250 beats/min, and supraventricular tachycardia discriminators were used for rhythms < or =200 beats/min. The control cohort consisted of 689 primary prevention patients from the EMPIRIC (Comparison of Empiric to Physician-Tailored Programming of Implantable Cardioverter Defibrillators Trial) (non-Bi-V ICD, physician arm only) and MIRACLE ICD (Multicenter InSync Implantable Cardioversion Defibrillation Randomized Clinical Evaluation) (Bi-V ICD) trials for whom VT/VF detection and therapy programming were not controlled. RESULTS: The PREPARE programming significantly reduced the morbidity index incidence density (0.26 events/patient-year for PREPARE study patients vs. 0.69 control cohort, p = 0.003). The PREPARE study patients were less likely to receive a shock in the first year compared with control patients (9% vs. 17%, p < 0.01). The incidence of untreated VT and arrhythmic syncope was similar between the PREPARE study patients and the control cohort. CONCLUSIONS: Strategically chosen VT/VF detection and therapy parameters can safely reduce shocks and other morbidities associated with ICD therapy in patients receiving an ICD for primary prevention indications. (PREPARE-Primary Prevention Parameters Evaluation; NCT00279279).


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/estatística & dados numéricos , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia , Idoso , Estudos de Casos e Controles , Desfibriladores Implantáveis/efeitos adversos , Feminino , Humanos , Incidência , Masculino , Estudos Prospectivos , Fatores de Risco , Volume Sistólico , Síncope/prevenção & controle , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/prevenção & controle , Fibrilação Ventricular/fisiopatologia , Fibrilação Ventricular/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...