Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cardiovasc Revasc Med ; 64: 1-4, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38355340

RESUMO

BACKGROUND: Transcatheter mitral valve replacement (TMVR) faces anatomical challenges, currently limiting widespread adoption. OBJECTIVES: To describe the natural history and prognosis of patients ineligible for various TMVR devices. METHODS: During a 4-year period (2019-2023) 3 TMVR devices (SAPIEN M3, Intrepid and Alta Valve) became available at a single institution (The Christ Hospital, Cincinnati, OH) in the setting of pivotal clinical trials or early feasibility study. Consenting patients who were deemed ineligible ≥1 of these trials were prospectively studied to capture anatomical reasons for ineligibility, cross-over to alternative mitral valve therapies (surgery or high-risk mitral transcatheter edge to edge repair [M-TEER]), and clinical events. RESULTS: A total of 61 patients (out of 71 consenting patients or 85.9 %) were deemed ineligible for TMVR during the study period. The mean age was 79.2 ± 8.8 years, 65.6 % were female, with elevated surgical risk (median STS 4.3, IQR: 2.7-7.3). The 2 most common anatomical reasons for ineligibility were increased risk of left ventricular outflow tract obstruction (LVOTO) (n = 24, 39.3 %) and annular size (n = 29, 47.5 %). During follow-up (median 277 [162-555] days) there were 7 deaths (11.5 %) and 12 (19.7 %) hospitalizations for heart failure. Management strategies included high-risk M-TEER in 11 patients (1 death [9.0 %], 0 HF hospitalizations [0 %]), surgery in 9 patients (0 deaths, 1 HF hospitalizations [11.1 %]), and medical management in 41 patients (6 deaths [14.6 %], 11 HF hospitalizations [26.8 %]) (p = 0.715 for mortality and p = 0.093 for HF hospitalizations). Residual MR ≥ moderate was 0 %, 50 %, and 100 % for surgery, M-TEER and medical treatment, respectively (p < 0.001). CONCLUSIONS: One third of patients deemed ineligible for TMVR are candidates for high-risk M-TEER or surgery with acceptable morbidity and mortality. Our results have practical implications for patient management.


Assuntos
Cateterismo Cardíaco , Definição da Elegibilidade , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Valva Mitral , Seleção de Pacientes , Humanos , Feminino , Masculino , Idoso , Valva Mitral/cirurgia , Valva Mitral/fisiopatologia , Valva Mitral/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Idoso de 80 Anos ou mais , Fatores de Risco , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Resultado do Tratamento , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Fatores de Tempo , Medição de Risco , Estudos Prospectivos , Recuperação de Função Fisiológica , Desenho de Prótese , Tomada de Decisão Clínica
2.
JACC Cardiovasc Imaging ; 17(5): 471-485, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38099912

RESUMO

BACKGROUND: The CLASP IID randomized trial (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial) demonstrated the safety and effectiveness of the PASCAL system for mitral transcatheter edge-to-edge repair (M-TEER) in patients at prohibitive surgical risk with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: This study describes the echocardiographic methods and outcomes from the CLASP IID trial and analyzes baseline variables associated with residual mitral regurgitation (MR) ≤1+. METHODS: An independent echocardiographic core laboratory assessed echocardiographic parameters based on American Society of Echocardiography guidelines focusing on MR mechanism, severity, and feasibility of M-TEER. Factors associated with residual MR ≤1+ were identified using logistic regression. RESULTS: In 180 randomized patients, baseline echocardiographic parameters were well matched between the PASCAL (n = 117) and MitraClip (n = 63) groups, with flail leaflets present in 79.2% of patients. Baseline MR was 4+ in 76.4% and 3+ in 23.6% of patients. All patients achieved MR ≤2+ at discharge. The proportion of patients with MR ≤1+ was similar in both groups at discharge but diverged at 6 months, favoring PASCAL (83.7% vs 71.2%). Overall, patients with a smaller flail gap were significantly more likely to achieve MR ≤1+ at discharge (adjusted OR: 0.70; 95% CI: 0.50-0.99). Patients treated with PASCAL and those with a smaller flail gap were significantly more likely to sustain MR ≤1+ to 6 months (adjusted OR: 2.72 and 0.76; 95% CI: 1.08-6.89 and 0.60-0.98, respectively). CONCLUSIONS: The study used DMR-specific echocardiographic methodology for M-TEER reflecting current guidelines and advances in 3-dimensional echocardiography. Treatment with PASCAL and a smaller flail gap were significant factors in sustaining MR ≤1+ to 6 months. Results demonstrate that MR ≤1+ is an achievable benchmark for successful M-TEER. (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial [CLASP IID]; NCT03706833).


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Valva Mitral , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/fisiopatologia , Masculino , Feminino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Valva Mitral/fisiopatologia , Resultado do Tratamento , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Idoso , Fatores de Risco , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Fatores de Tempo , Idoso de 80 Anos ou mais , Próteses Valvulares Cardíacas , Estudos de Viabilidade , Medição de Risco , Desenho de Prótese , Ecocardiografia Tridimensional
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...