Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Vet Intern Med ; 37(2): 428-436, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36866722

RESUMO

BACKGROUND: Angiodysplasia (AGD) is rarely diagnosed in dogs with gastrointestinal bleeding (GIB) and is reported in case reports in dogs. OBJECTIVE: Describe signalment, clinical and diagnostic features of dogs with gastrointestinal (GI) AGD diagnosed by video capsule endoscopy (VCE). ANIMALS: Dogs with overt or suspected GIB which underwent VCE. METHODS: Dogs for which a VCE was submitted for overt or suspected GIB from 2016 to 2021 were selected retrospectively. Medical records and full-length VCE recordings where AGDs were initially detected, were reviewed by 2 trained internists. AGD was considered definitive if 2 readers detected it. Signalment, clinical signs, blood work, medications, concurrent diseases, findings of previous conventional endoscopy, and surgical exploration (if applicable) of dogs with AGD were recorded. RESULTS: Definitive AGD was diagnosed in 15 of 291 (5%) dogs (12 males, 3 females). Twelve (80%) had overt GIB, 11 (73%) had hematochezia, and 6 (40%) had microcytic and hypochromic anemia. AGD was missed by conventional endoscopy in 9/9 dogs and exploratory surgery in 3/3 dogs. Thirteen capsules were administered by mouth (1 incomplete study), and 2 via endoscopy directly into the duodenum. AGD was visualized in the stomach of 3 dogs, in the small intestine of 4, and in the colon of 13 dogs. CONCLUSION AND CLINICAL IMPORTANCE: Although rare, AGD should be considered in dogs with suspected GIB after a negative conventional endoscopy or surgical exporation. Video capsuel endoscopy appears to be a sensitive test to identify AGD within the GI tract.


Assuntos
Angiodisplasia , Endoscopia por Cápsula , Doenças do Cão , Masculino , Feminino , Cães , Animais , Endoscopia por Cápsula/veterinária , Estudos Retrospectivos , Endoscopia Gastrointestinal/veterinária , Endoscopia Gastrointestinal/efeitos adversos , Intestino Delgado , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/veterinária , Angiodisplasia/diagnóstico , Angiodisplasia/veterinária , Angiodisplasia/complicações , Doenças do Cão/diagnóstico
2.
J Vet Intern Med ; 35(4): 1743-1753, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33993552

RESUMO

BACKGROUND: Prospective studies describing video capsule endoscopy (VCE), its feasibility, and complications in dogs are limited. OBJECTIVE: To assess VCE, quality of visualization, complications, and risk factors for incomplete studies in dogs with overt or questionable gastrointestinal bleeding (GIB). ANIMALS: Forty dogs with overt or questionable GIB. METHODS: Prospective, multicenter, interventional study. From August 2017 to March 2020, dogs were examined by VCE (ALICAM) because of overt or questionable GIB. Reported outcomes included diagnostic results of VCE study, quality of visualization, and complications. Risk factors for incomplete studies were evaluated using logistic regression. RESULTS: In total, 40 dogs (13 overt, 27 questionable GIB) were included. The capsules were administered PO in 29 and endoscopically in 11 dogs (6 duodenum, 5 stomach). One capsule was not retrieved. In 24 of 39 recordings, bleeding lesions were identified (10 overt GIB, 14 questionable GIB). Overall, the quality of visualization was poor to limited in the stomach and colon, and adequate to good in the small intestine. The most common complication was an incomplete study in 15/39 studies, particularly after oral administration (13/28). Risk factors for incomplete study after oral administration included administration of simethicone or opioids, chronic enteropathy, and capsule gastric transit time >6 hours. CONCLUSIONS AND CLINICAL IMPORTANCE: Video capsule endoscopy can be used to diagnose a variety of lesions causing bleeding in the gastrointestinal tract of dogs with questionable GIB. Incomplete studies are the most common complications in dogs after oral administration of capsules.


Assuntos
Endoscopia por Cápsula , Doenças do Cão , Animais , Endoscopia por Cápsula/veterinária , Doenças do Cão/diagnóstico por imagem , Cães , Endoscopia Gastrointestinal/veterinária , Estudos de Viabilidade , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/veterinária , Intestino Delgado , Estudos Prospectivos , Estudos Retrospectivos
3.
J Vet Intern Med ; 35(3): 1427-1438, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33728701

RESUMO

BACKGROUND: Urea nitrogen/creatinine ratio (UCR) is a marker for upper gastrointestinal bleeding (GIB) in people. OBJECTIVES: To assess the usefulness of UCR to predict occult GIB and distinguish upper from lower GIB in dogs. ANIMALS: Eighty-nine dogs with GIB and 65 clinically healthy dogs. Dogs were grouped according to 65 overt GIB and 24 occult GIB, and based on lesion localization (37 upper, 13 lower, and 8 both). METHODS: Seventy-four dogs were included retrospectively and 15 dogs prospectively. Serum urea nitrogen and creatinine concentrations, UCR, hemoglobin concentration, hematocrit, mean corpuscular volume, and mean corpuscular hemoglobin concentration were compared between groups. Logistic regression models were fitted to assess if variables could distinguish occult GIB from being healthy and upper from lower GIB. RESULTS: The UCR was significantly higher in dogs with overt GIB compared to control dogs (P = .02) and dogs with occult GIB (P = .05). The UCR was not significantly associated with occult GIB vs being healthy, or upper vs lower GIB (P > .05 each). Dogs with higher hemoglobin concentration and hematocrit had significantly lower odds of having occult GIB than being healthy (P < .0001 each). CONCLUSIONS AND CLINICAL IMPORTANCE: The UCR does not seem to be a clinically useful marker of occult GIB and appears to have poor discriminatory ability between upper and lower GIB. An increased UCR in a dog without signs of overt GIB, especially if its hematocrit is within the middle or upper reference interval, does not appear to warrant prompt prescription of gastrointestinal protectants.


Assuntos
Doenças do Cão , Nitrogênio , Animais , Creatinina , Doenças do Cão/diagnóstico , Cães , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/veterinária , Estudos Retrospectivos , Ureia
4.
J Vet Diagn Invest ; 28(3): 235-243, 2016 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-26961324

RESUMO

Haptoglobin is a positive moderate acute phase protein (APP) in cats. Measurement of haptoglobin can be used in the diagnosis, prognosis, and monitoring of systemic inflammatory disease, especially by creating profiles with major APPs. The aim of our study was to validate a sandwich enzyme-linked immunosorbent assay (ELISA) for measurement of feline haptoglobin. The validation included an assessment of precision, accuracy, detection limit, method comparison with a spectrophotometric assay, and evaluation of the overlap performance. The concentration of haptoglobin was measured in serum from 27 healthy and 23 sick cats. The coefficients of variation were 2.5-4.7% for intra-assay variability and 7.1-11.6% for interassay variability. The ratio of observed to expected dilutional parallelism of 4 serum samples was 108.1-118.4%. The ratio of observed to expected spike recovery of 4 serum samples was 90.8-94.0%. The lower detection limit was 0.19 g/L. Method comparison revealed a positive correlation (rs = 0.949, P < 0.0001) and a proportional bias between the methods of -38.9%. Agreement between the methods was not clinically acceptable. Overlap performance of the ELISA was deemed satisfactory. The sandwich ELISA measures feline haptoglobin with an analytical and overlap performance acceptable for clinical purposes. Given the observed bias, the ELISA cannot be used interchangeably with the spectrophotometric assay.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...