Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Coll Antropol ; 35 Suppl 1: 45-9, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21648310

RESUMO

In this paper, our experience with originally constructed Neurosurgical Endoscopic Contact Ultrasound Probe "NECUP-2" in neuroendoscopy is reported. Between June 1997 and June 2007, 132 neuroendoscopic procedures have been performed: 102 endoscopic thrid ventriculostomies (ETV), 15 arachnoid cysts and 5 intraventricular tumours operations. The "NECUP-2" was applied effectively in all cases in which blunt perforation was not possible: 38/102 ETY, 10/10 septostomies, 15/15 arachnoid cysts. In five cases of intraventricular tumours, neuroendoscopic procedure was combined with open microsurgery for tumour removal with preservation of vascular structures. There were no "NECUP-2" related complications. Of postoperative complications, we had liquorrhea (9 patients), and symptoms of meningitis (6 patients). In the follow-up period (6 months to 6 years), we had a patency rate of 80% (50/63 patients). All patients improved in clinical status. According to the first results, it seems that ultrasonic contact probe NECUP-2 presents a new device in neurosurgical armamentarium that can be used in various fields of neurosurgery. With minimal and controlled lesion that is produced at the tip of the probe, it can be used in highly demanding operations such as third ventriculostomy and tumour resection.


Assuntos
Neuroendoscópios , Neuroendoscopia/instrumentação , Neuroendoscopia/métodos , Ultrassonografia/instrumentação , Cistos Aracnóideos/diagnóstico por imagem , Cistos Aracnóideos/cirurgia , Desenho de Equipamento , Feminino , Humanos , Hidrocefalia/diagnóstico por imagem , Hidrocefalia/cirurgia , Lactente , Masculino , Ventriculostomia/instrumentação , Ventriculostomia/métodos
2.
Coll Antropol ; 35 Suppl 1: 107-13, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21648319

RESUMO

Measurement of the acoustic power in high-energy ultrasonic devices is complex due to occurrence of the strong cavitation in front of the sonotrode tip. In our research we used three methods for characterization of our new ultrasonic probe for neuroendoscopic procedures. The first method is based on the electromechanical characterization of the device measuring the displacement of the sonotrode tip and input electrical impedance around excitation frequency with different amounts of the applied electrical power The second method is based on measuring the spatial pressure magnitude distribution of an ultrasound surgical device produced in an anechoic tank. The acoustic reciprocity principle is used to determinate the derived acoustic power of equivalent ultrasound sources at frequency components present in the spectrum of radiated ultrasonic waves. The third method is based on measuring the total absorbed acoustic power in the restricted volume of water using the calorimetric method. In the electromechanical characterization, calculated electroacoustic efficiency factor from equivalent electrical circuits is between 40-60%, the same as one obtained measuring the derived acoustic power in an anechoic tank when there is no cavitation. When cavitation activity is present in the front of the sonotrode tip the bubble cloud has a significant influence on the derived acoustic power and decreases electroacoustic efficiency. The measured output acoustic power using calorimetric method is greater then derived acoustic power, due to a large amount of heat energy released in the cavitation process.


Assuntos
Procedimentos Neurocirúrgicos/instrumentação , Ultrassonografia/instrumentação , Desenho de Equipamento , Ultrassonografia/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...