Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Environ Radioact ; 148: 130-6, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26162768

RESUMO

This paper presents complex studies on establishment of derived emission limits for potential radionuclides emitted as gaseous and liquid effluents, during the decommissioning activities (2nd and 3rd phases) of a nuclear research reactor, cooled and moderated with distilled water, type VVR-S, owned by the IFIN-HH. In the present paper there are described: the analysis methods and equipment used, the methodologies for calculating doses and the Derived Emission Limits (DEL), the experimentally measured activities of the representative radionuclides found in gaseous and liquid effluents resulted from decommissioning activities, as well as the effective derived limits of liquid and gaseous effluents, applying the calculation methodologies, specific to critical categories of exposed subjects. A constraint effective dose limit for a person from the critical group of 50 µSv/year was considered in calculations. From the comparison of the two series of values, measured released activities and DELs, there has been concluded that for the gaseous effluents they comply with the DELs, while in the case of liquid effluents they are higher and consequently they must be treated as liquid radioactive wastes.


Assuntos
Poluentes Radioativos do Ar/análise , Reatores Nucleares , Monitoramento de Radiação/métodos , Resíduos Radioativos/análise , Poluentes Radioativos da Água/análise , Monitoramento de Radiação/instrumentação , Romênia
2.
Appl Radiat Isot ; 68(4-5): 614-6, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-19815420

RESUMO

This paper presents the measurement of the dose equivalent Hp(10) to low (0.005-1) mSv and high (20-1000) mSv doses by exposure at (241)Am and (173)Cs radiation sources of the halide film with FB-III-D dosimeter system. Accuracy of measurements, standard error of the dose mean value (SEM) and some comments about ability to reread of dosimetric films were determined. A good accuracy was obtained over the important dose ranges. In the low dose range, under 0.1 mSv, the SEM values of the (241)Am doses, recorded on the film under plastic filter, are between -21.36% and +47.51%. For 0.1-500 mSv (137)Cs dose range the SEM values are from -9.55% to +7.24%.


Assuntos
Dosimetria Fotográfica/instrumentação , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Dosimetria Fotográfica/métodos , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Appl Radiat Isot ; 66(10): 1501-6, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18487054

RESUMO

A low-background radiation laboratory was constructed and fully commissioned in 2006 in the former Unirea (Slanic-Prahova) salt mine at 208 m below surface (estimated to 560 m water equivalent). Preliminary measurements showed a global reduction of the absorbed dose due to natural factors of about 39 times compared to level on the surface, reaching inside the mine 1.17+/-0.14 nGy/h. The total gamma background spectrum between 40 KeV and 3 MeV was 100 times smaller at laboratory level with respect to the same spectrum recorder at surface, in open field. All these experimental facts recommend the Slanic-Prahova low-background radiation laboratory, at present time fully operational, as very suitable for various measurements needing a low background.


Assuntos
Laboratórios , Proteção Radiológica/instrumentação , Radiometria/instrumentação , Espectrometria gama/instrumentação , Radiação de Fundo , Desenho de Equipamento , Análise de Falha de Equipamento , Romênia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...