1.
J Autom Methods Manag Chem ; 2008: 498921, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18401449

RESUMO

MODULAR ANALYTICS Serum Work Area (in USA Integrated MODULAR ANALYTICS, MODULAR ANALYTICS is a trademark of a member of the Roche Group) represents a further approach to automation in the laboratory medicine. This instrument combines previously introduced modular systems for the clinical chemistry and immunochemistry laboratory and allows customised combinations for various laboratory workloads. Functionality, practicability, and workflow behaviour of MODULAR ANALYTICS Serum Work Area were evaluated in an international multicenter study at six laboratories. Across all experiments, 236000 results from 32400 samples were generated using 93 methods. Simulated routine testing which included provocation incidents and anomalous situations demonstrated good performance and full functionality. Heterogeneous immunoassays, performed on the E-module with the electrochemiluminescence technology, showed reproducibility at the same level of the general chemistry tests, which was well within the clinical demands. Sample carryover cannot occur due to intelligent sample processing. Workflow experiments for the various module combinations, with menus of about 50 assays, yielded mean sample processing times of <38 minutes for combined clinical chemistry and immunochemistry requests; <50 minutes including automatically repeated samples. MODULAR ANALYTICS Serum Work Area offered simplified workflow by combining various laboratory segments. It increased efficiency while maintaining or even improving quality of laboratory processes.

2.
J Autom Methods Manag Chem ; 2008: 183747, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18320013

RESUMO

The established protocols for evaluating new analytical systems produce indispensable information with regard to quality characteristics, but in general they fail to analyse the system performance under routine-like conditions. We describe a model which allows the testing of a new analytical system under conditions close to the routine in a controlled and systematic manner by using an appropriate software tool. Performing routine simulation experiments, either reflecting imprecision or method comparison characteristics, gives the user essential information on the overall system performance under real intended-use conditions.

3.
J Autom Methods Manag Chem ; 2005: 8-25, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-18924721

RESUMO

MODULAR ANALYTICS (Roche Diagnostics) (MODULAR ANALYTICS, Elecsys and Cobas Integra are trademarks of a member of the Roche Group) represents a new approach to automation for the clinical chemistry laboratory. It consists of a control unit, a core unit with a bidirectional multitrack rack transportation system, and three distinct kinds of analytical modules: an ISE module, a P800 module (44 photometric tests, throughput of up to 800 tests/h), and a D2400 module (16 photometric tests, throughput up to 2400 tests/h). MODULAR ANALYTICS allows customised configurations for various laboratory workloads. The performance and practicability of MODULAR ANALYTICS were evaluated in an international multicentre study at 16 sites. Studies included precision, accuracy, analytical range, carry-over, and workflow assessment. More than 700 000 results were obtained during the course of the study. Median between-day CVs were typically less than 3% for clinical chemistries and less than 6% for homogeneous immunoassays. Median recoveries for nearly all standardised reference materials were within 5% of assigned values. Method comparisons versus current existing routine instrumentation were clinically acceptable in all cases. During the workflow studies, the work from three to four single workstations was transferred to MODULAR ANALYTICS, which offered over 100 possible methods, with reduction in sample splitting, handling errors, and turnaround time. Typical sample processing time on MODULAR ANALYTICS was less than 30 minutes, an improvement from the current laboratory systems. By combining multiple analytic units in flexible ways, MODULAR ANALYTICS met diverse laboratory needs and offered improvement in workflow over current laboratory situations. It increased overall efficiency while maintaining (or improving) quality.

4.
Clin Chem Lab Med ; 42(10): 1186-202, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15552279

RESUMO

The E170 module was evaluated at 13 sites in an international multicentre study. The objective of the study was to assess the analytical performance of 49 analytes, and to collect feedback on the system's reliability and practicability. The typical, within-run coefficients of variation (CVs) for most of the quantitative assays ranged between 1 and 2% while a range of 2-4% was achieved with the infectious disease methods. Total precision CVs were found to be within the manufacturer's expected performance ranges, demonstrating good concordance of the system's measuring channels and a high reproducibility during the 2-4-week trial period. The functional sensitivity of 11 selected assays met the clinical requirements (e.g., thyreotroponin (TSH) 0.008 mU/l, troponin T 0.02 microg/l, total prostate-specific antigen (PSA) 0.03 microg/l). The E170 showed no drift during an 8-hour period and no relevant reagent carryover. Accuracy was confirmed by ring trial experiments and method comparisons vs. Elecsys 2010. The reliability and practicability of the system's hardware and software met with, or even exceeded, the evaluator's requirements. Workflow studies showed that E170 can cover the combined workload of various routine analysers in a variety of laboratory environment. Throughput and sample processing time requirements were achieved while personnel 'hands-on-time' could be reduced.


Assuntos
Química Clínica/métodos , Reprodutibilidade dos Testes , Calibragem , Ferritinas/sangue , Humanos , Masculino , Antígeno Prostático Específico/sangue , Kit de Reagentes para Diagnóstico/classificação , Kit de Reagentes para Diagnóstico/normas , Sensibilidade e Especificidade , Software , Tireotropina/sangue , Tempo , Troponina/sangue
5.
Clin Chem Lab Med ; 41(3): 365-81, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12705348

RESUMO

The new selective access analyser Cobas Integra 800 from Roche Diagnostics was evaluated in an international multicentre study at six sites. Routine simulation experiments showed good performance and full functionality of the instrument and provocation of anomalous situations generated no problems. The new features on Cobas Integra 800, namely clot detection and dispensing control, worked according to specifications. The imprecision of Cobas Integra 800 fulfilled the proposed quality specifications regarding imprecision of analytical systems for clinical chemistry with few exceptions. Claims for linearity, drift, and carry-over were all within the defined specifications, except urea linearity. Interference exists in some cases, as could be expected due to the chemistries applied. Accuracy met the proposed quality specifications, except in some special cases. Method comparisons with Cobas Integra 700 showed good agreement; comparisons with other analysis systems yielded in several cases explicable deviations. Practicability of Cobas Integra 800 met or exceeded the requirements for more than 95% of all attributes rated. The strong points of the new analysis system were reagent handling, long stability of calibration curves, high number of tests on board, compatibility of the sample carrier to other Roche systems, and the sample integrity check for more reliable analytical results. The improvement of the workflow offered by the 5-position rack and STAT handling like on Cobas Integra 800 makes the instrument attractive for further consolidation in the medium-sized laboratory, for dedicated use of special analytes, and/or as back-up in the large routine laboratory.


Assuntos
Química Clínica/instrumentação , Proteínas Sanguíneas/análise , Química Clínica/normas , Química Clínica/estatística & dados numéricos , Eletrólitos/análise , Enzimas/análise , Humanos , Drogas Ilícitas/análise , Indicadores e Reagentes , Agências Internacionais , Preparações Farmacêuticas/análise , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes , Software