Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 4196, 2024 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-38378866

RESUMO

Muscle function is compromised by gravitational unloading in space affecting overall musculoskeletal health. Astronauts perform daily exercise programmes to mitigate these effects but knowing which muscles to target would optimise effectiveness. Accurate inflight assessment to inform exercise programmes is critical due to lack of technologies suitable for spaceflight. Changes in mechanical properties indicate muscle health status and can be measured rapidly and non-invasively using novel technology. A hand-held MyotonPRO device enabled monitoring of muscle health for the first time in spaceflight (> 180 days). Greater/maintained stiffness indicated countermeasures were effective. Tissue stiffness was preserved in the majority of muscles (neck, shoulder, back, thigh) but Tibialis Anterior (foot lever muscle) stiffness decreased inflight vs. preflight (p < 0.0001; mean difference 149 N/m) in all 12 crewmembers. The calf muscles showed opposing effects, Gastrocnemius increasing in stiffness Soleus decreasing. Selective stiffness decrements indicate lack of preservation despite daily inflight countermeasures. This calls for more targeted exercises for lower leg muscles with vital roles as ankle joint stabilizers and in gait. Muscle stiffness is a digital biomarker for risk monitoring during future planetary explorations (Moon, Mars), for healthcare management in challenging environments or clinical disorders in people on Earth, to enable effective tailored exercise programmes.


Assuntos
Voo Espacial , Humanos , Astronautas , Músculo Esquelético/fisiologia , Exercício Físico/fisiologia , Marcha
2.
Sci Rep ; 9(1): 5569, 2019 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-30944380

RESUMO

Electromyography (EMG) is the standard technology for monitoring muscle activity in laboratory environments, either using surface electrodes or fine wire electrodes inserted into the muscle. Due to limitations such as cost, complexity, and technical factors, including skin impedance with surface EMG and the invasive nature of fine wire electrodes, EMG is impractical for use outside of a laboratory environment. Mechanomyography (MMG) is an alternative to EMG, which shows promise in pervasive applications. The present study used an exerting squat-based task to induce muscle fatigue. MMG and EMG amplitude and frequency were compared before, during, and after the squatting task. Combining MMG with inertial measurement unit (IMU) data enabled segmentation of muscle activity at specific points: entering, holding, and exiting the squat. Results show MMG measures of muscle activity were similar to EMG in timing, duration, and magnitude during the fatigue task. The size, cost, unobtrusive nature, and usability of the MMG/IMU technology used, paired with the similar results compared to EMG, suggest that such a system could be suitable in uncontrolled natural environments such as within the home.


Assuntos
Músculo Esquelético/fisiologia , Adulto , Eletromiografia/métodos , Feminino , Humanos , Masculino , Contração Muscular/fisiologia , Fadiga Muscular/fisiologia
3.
Br J Sports Med ; 53(23): 1447-1453, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31023858

RESUMO

Physical therapists employ ultrasound (US) imaging technology for a broad range of clinical and research purposes. Despite this, few physical therapy regulatory bodies guide the use of US imaging, and there are limited continuing education opportunities for physical therapists to become proficient in using US within their professional scope of practice. Here, we (i) outline the current status of US use by physical therapists; (ii) define and describe four broad categories of physical therapy US applications (ie, rehabilitation, diagnostic, intervention and research US); (iii) discuss how US use relates to the scope of high value physical therapy practice and (iv) propose a broad framework for a competency-based education model for training physical therapists in US. This paper only discusses US imaging-not 'therapeutic' US. Thus, 'imaging' is implicit anywhere the term 'ultrasound' is used.


Assuntos
Educação Baseada em Competências , Modelos Educacionais , Modalidades de Fisioterapia , Ultrassonografia , Consenso , Currículo , Humanos , Fisioterapeutas/educação , Âmbito da Prática
4.
Front Physiol ; 9: 810, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30018567

RESUMO

The human resting muscle tone (HRMT) system provides structural and functional support to skeletal muscle and associated myofascial structures (tendons, fascia) in normal life. Little information is available on changes to the HRMT in bed rest. A set of dynamic oscillation mechanosignals ([Hz], [N/m], log decrement, [ms]) collected and computed by a hand-held digital palpation device (MyotonPRO) were used to study changes in tone and in key biomechanical and viscoelastic properties in global and postural skeletal muscle tendons and fascia from a non-exercise control (CTR) and an exercise (JUMP) group performing reactive jumps on a customized sledge system during a 60 days head-down tilt bed rest (RSL Study 2015-2016). A set of baseline and differential natural oscillation signal patterns were identified as key determinants in resting muscle and myofascial structures from back, thigh, calf, patellar and Achilles tendon, and plantar fascia. The greatest changes were found in thigh and calf muscle and tendon, with little change in the shoulder muscles. Functional tests (one leg jumps, electromyography) showed only trends in relevant leg muscle groups. Increased anti-Collagen-I immunoreactivity found in CTR soleus biopsy cryosections was absent from JUMP. Results allow for a muscle health status definition after chronic disuse in bed rest without and with countermeasure, and following reconditioning. Findings improve our understanding of structural and functional responses of the HRMT to disuse and exercise, may help to guide treatment in various clinical settings (e.g., muscle tone disorders, neuro-rehabilitation), and promote monitoring of muscle health and training status in personalized sport and space medicine.

5.
J Vis Exp ; (96): e51717, 2015 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-25742242

RESUMO

The measurement of dynamic scapular kinematics is complex due to the sliding nature of the scapula beneath the skin surface. The aim of the study was to clearly describe the acromion marker cluster (AMC) method of determining scapular kinematics when using a passive marker motion capture system, with consideration for the sources of error which could affect the validity and reliability of measurements. The AMC method involves placing a cluster of markers over the posterior acromion, and through calibration of anatomical landmarks with respect to the marker cluster it is possible to obtain valid measurements of scapular kinematics. The reliability of the method was examined between two days in a group of 15 healthy individuals (aged 19-38 years, eight males) as they performed arm elevation, to 120°, and lowering in the frontal, scapular and sagittal planes. Results showed that between-day reliability was good for upward scapular rotation (Coefficient of Multiple Correlation; CMC = 0.92) and posterior tilt (CMC = 0.70) but fair for internal rotation (CMC = 0.53) during the arm elevation phase. The waveform error was lower for upward rotation (2.7° to 4.4°) and posterior tilt (1.3° to 2.8°), compared to internal rotation (5.4° to 7.3°). The reliability during the lowering phase was comparable to results observed during the elevation phase. If the protocol outlined in this study is adhered to, the AMC provides a reliable measurement of upward rotation and posterior tilt during the elevation and lowering phases of arm movement.


Assuntos
Acrômio/fisiologia , Eletrônica/métodos , Movimento/fisiologia , Escápula/fisiologia , Fenômenos Fisiológicos da Pele , Adulto , Artefatos , Fenômenos Biomecânicos , Eletrônica/instrumentação , Feminino , Humanos , Masculino , Óptica e Fotônica , Adulto Jovem
6.
Artigo em Inglês | MEDLINE | ID: mdl-24156508

RESUMO

The aim of this study was to assess the potential of employing a classification tool to objectively classify participants with clinically assessed movement faults (MFs) of the scapula. Six participants with a history of shoulder pain with MFs of the scapula and 12 healthy participants with no movement faults (NMFs) performed a flexion movement control test of the scapula, while scapular kinematic data were collected. Principal component scores and discrete kinematic variables were used as input into a classifier. Five out of the six participants with a history of pain were successfully classified as having scapular MFs with an accuracy of 72%. Variables related to the upward rotation of the scapula had the most influence on the classification. The results of the study demonstrate the potential of adopting a multivariate approach in objective classification of participants with altered scapular kinematics in pathological groups.


Assuntos
Transtornos dos Movimentos/classificação , Movimento/fisiologia , Amplitude de Movimento Articular/fisiologia , Escápula/fisiologia , Articulação do Ombro/fisiologia , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Análise de Componente Principal , Rotação
7.
J Orthop Sports Phys Ther ; 43(7): 466-77, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23633621

RESUMO

STUDY DESIGN: Validation study. OBJECTIVES: To investigate the association between changes in electromyographic (EMG) signal amplitude and sonographic measures of muscle thickness of 4 abdominal muscles, during 2 clinical tests, in adults with and without lumbopelvic pain. BACKGROUND: There is a trend in rehabilitation to use ultrasound imaging (USI) to determine the extent of abdominal muscle contraction. However, the literature investigating the relationship between abdominal muscle thickness change and level of activation is inconclusive and has not included clinically relevant tasks. METHODS: Simultaneous recording from fine-wire EMG and USI was performed for 4 abdominal muscles, in 7 adults with lumbopelvic pain (mean ± SD age, 29.7 ± 12.0 years) and 7 adults without lumbopelvic pain (32.0 ± 10.6 years), during an active straight leg raise (ASLR) test and an abdominal drawing-in maneuver (ADIM). Cross-correlation functions and linear regression analyses were used to describe the relationship between the 2 measures. Analyses of variance were used to compare individuals with and without lumbopelvic pain, with an alpha set at .05. RESULTS: Across all muscles, peak cross-correlation values were low (ASLR, r = 0.28 ± 0.09; ADIM, r = 0.35 ± 0.11), and there was large variability in associated time lags (ASLR, τ = 0.69 ± 2.56 seconds; ADIM, τ = 0.53 ± 3.75 seconds). Regression analyses did not detect a systematic pattern of association between EMG signal amplitude and USI measurements, and analyses of variance revealed no differences between cohorts. CONCLUSION: These results suggest a weak relationship between EMG amplitude and abdominal muscle thickness change measured with USI during the ADIM and ASLR, and raise questions about thickness change derived from USI as a measure of muscular activity for the abdominal musculature.


Assuntos
Músculos Abdominais/fisiologia , Eletromiografia , Músculos Abdominais/diagnóstico por imagem , Adolescente , Adulto , Estudos de Casos e Controles , Feminino , Humanos , Modelos Lineares , Dor Lombar/fisiopatologia , Masculino , Pessoa de Meia-Idade , Dor Pélvica/fisiopatologia , Ultrassonografia , Adulto Jovem
8.
J Ultrasound Med ; 31(7): 1099-110, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22733859

RESUMO

OBJECTIVES: The purpose of this study was to establish reference values for abdominal and lumbar multifidus muscles at rest and while contracted in a sample of active healthy adults. METHODS: Three hundred forty participants (mean age ± SD, 21.8 ± 3.9 years; 96 females and 244 males) completed the study. Ultrasound imaging was used to assess the thickness of the transversus abdominis, internal and external oblique, rectus abdominis, and lumbar multifidus muscles. Additionally, the cross-sectional area of the rectus abdominis was assessed. RESULTS: Although males had significantly thicker muscles than females (P < .05), the relative change in thickness during specified tasks was equivalent. Overall, relative muscle thickness and symmetry were similar to previous studies using smaller sample sizes. CONCLUSIONS: These findings provide a robust data set of muscle thickness values measured by ultrasound imaging and can be used for comparison to those with pain, abnormal function, and pathologic conditions.


Assuntos
Dorso/fisiologia , Contração Muscular/fisiologia , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiologia , Adolescente , Adulto , Feminino , Humanos , Masculino , Tamanho do Órgão/fisiologia , Valores de Referência , Reprodutibilidade dos Testes , Descanso/fisiologia , Sensibilidade e Especificidade , Ultrassonografia , Adulto Jovem
9.
Ultrasound Med Biol ; 36(8): 1288-97, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20598434

RESUMO

Clinical use of ultrasound imaging by physiotherapists is increasing; however, the clinical setting may be problematic due to variability inherent in the environment. As transducer motion interferes with accurate measurement, this study aimed to measure handheld transducer motion, relative to the pelvis, during a clinical simulation involving typical maneuvers employed in a physiotherapy assessment of the lumbopelvic region. Transducer motion about three axes and through one plane was measured (Vicon, Oxford, UK) on 12 participants during three clinical maneuvers at four abdominal imaging sites. Data were grouped and means used to determine discrepancies in transducer and pelvic motion for each imaging site/maneuver combination. None of the conditions produced large transducer motions relative to the pelvis and all findings were within previously established guidelines for acceptable amounts of transducer motion. These findings suggest that an ultrasound transducer can be held relatively stationary in a clinical setting, for the maneuvers tested.


Assuntos
Abdome/diagnóstico por imagem , Artefatos , Exame Físico/métodos , Modalidades de Fisioterapia , Mecânica Respiratória/fisiologia , Transdutores , Abdome/fisiologia , Adulto , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia
10.
Ultrasound Med Biol ; 35(11): 1803-11, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19699027

RESUMO

The use of ultrasound imaging (USI) by physiotherapists to assess muscle behavior in clinical settings is increasing. However, there is relatively little evidence of whether the clinical environment is conducive to valid and reliable measurements. Accurate USI measurements depend on maintaining a relatively stationary transducer position, because motion may distort the image and lead to erroneous conclusions. This would seem particularly important during dynamic studies typical of a physiotherapy assessment. What is not known is how much transducer motion can occur before error is introduced. The aim of this study is to shed some light on this question. Eight healthy volunteers (19 to 52 y) participated. USI images were taken of the lateral abdominal wall (LAW) and bladder base (midline suprapubic) at various manually induced transducer orientations (approximately -10 to 10 degrees about 3 axes of rotation), which were quantified by a digital optical motion capture system. Measurements of transversus abdominis (TrA) thickness and bladder base position (cranial /caudal and anterior/posterior) were calculated. Repeated measures analysis of variance was performed to determine if the measurements obtained at the induced transducer orientations were statistically different (p<0.05) from an image corresponding to a reference or starting transducer orientation. Motion analysis data corresponding to measurements that did not differ from reference image measurements were summarized to provide a range of acceptable transducer motion (relative to the pelvis) for clockwise (CW)/counter-clockwise (CCW) rotation, cranial/caudal tilting, medial/lateral tilting and inward/outward displacement. There were no significant changes in TrA thickness measurements if CW/CCW transducer motion was <9 degrees and cranial/caudal or medial/lateral transducer tilting was <5 degrees . Further, there were no significant changes in measurements of bladder base position if CW/CCW transducer motion was <10 degrees , cranial/caudal or medial/lateral transducer tilting was <10 degrees and 8 degrees , respectively and inward/outward motion was <8 mm. These findings provide guidance on acceptable amounts of transducer motion relative to the pelvis when generating measurements of TrA thickness and bladder base position. Future sonographic studies and clinical assessment investigating these parameters could take these findings into account to improve imaging technique reliability.


Assuntos
Músculos Abdominais/diagnóstico por imagem , Bexiga Urinária/diagnóstico por imagem , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Orientação , Reprodutibilidade dos Testes , Transdutores , Ultrassonografia/instrumentação , Ultrassonografia/normas , Adulto Jovem
11.
Man Ther ; 13(2): 112-21, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-17208034

RESUMO

This cross-sectional and partial longitudinal study aimed to characterize changes in rectus abdominis (RA) and provide reference ranges for the first year postpartum. Ultrasound scanning was used at four stages postnatally to measure cross-sectional area (CSA), thickness, width (indirectly using a shape value) and inter-recti distance (IRD). One hundred and fifteen postnatal women (though some postnatal subjects appeared in more than one postnatal group thus giving a total of 183 data points) and 69 age-matched nulliparous female controls were recruited. Postnatal subjects were studied at Day 1 (PN1; n=63) and at 2 (PN2; n=55), 6 (PN3; n=39) and 12 (PN4; n=26) months postpartum. Longitudinal data were analysed for CSA, thickness, shape (indirect width measurement) (df=67) and IRD (df=62). The mean CSA of the PN1 group was significantly larger (P<0.001) than in controls and decreased (P<0.0021) by 12 months. In all postnatal groups, RA was significantly thinner (P<0.0001, PN1-PN3; P<0.0478, PN4), wider (P<0.0001, PN1-PN3; P=0.0326, PN4) and the IRD was significantly larger (P<0.0001, PN1-PN4) than in controls. Over 2 months postpartum, RA became thicker (P=0.0003) and the width and IRD decreased (P<0.0001 and P=0.0002, respectively) but did not return to control values by 12 months. These results have implications for strength of RA postpartum and anterior abdominal wall stiffness, which together with other muscle characteristics could inform development of effective postnatal exercise programmes.


Assuntos
Reto do Abdome/diagnóstico por imagem , Adolescente , Adulto , Estudos de Casos e Controles , Estudos Transversais , Terapia por Exercício , Feminino , Humanos , Estudos Longitudinais , Pessoa de Meia-Idade , Debilidade Muscular/diagnóstico por imagem , Debilidade Muscular/reabilitação , Período Pós-Parto , Reto do Abdome/anatomia & histologia , Valores de Referência , Análise de Regressão , Ultrassonografia
12.
Brain Cogn ; 51(3): 326-36, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12727187

RESUMO

Brain-computer interface (BCI) technology relies on the ability of individuals to voluntarily and reliably produce changes in their electroencephalographic (EEG) activity. The present paper reviews research on cognitive tasks and other methods of generating and controlling specific changes in EEG activity that can be used to drive BCI systems. To date, motor imagery has been the most commonly used task. This paper explores the possibility that other cognitive tasks, including those used in imaging studies, may prove to be more effective. Other factors which influence performance are also considered in relation to selection of tasks, as well as training of subjects.


Assuntos
Encéfalo/fisiologia , Eletroencefalografia , Aprendizagem/fisiologia , Interface Usuário-Computador , Encéfalo/anatomia & histologia , Humanos , Imageamento por Ressonância Magnética
13.
Clin Rehabil ; 17(1): 30-41, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12617377

RESUMO

OBJECTIVE: To investigate whether behavioural, motor and physiological responses of individuals with Huntington's disease (HD) to a controlled multisensory environment (MSE) are effective as a therapeutic (sustained effects) or leisure (immediate effects) activity. DESIGN: Pilot study--a randomized, controlled, two-group design. SETTING: Specialist residential unit for people with mid-late stage HD. SUBJECTS: Twelve patients with HD (one subject from each group dropped out during the study after week 8 due to medical complications). INTERVENTIONS: Patients attended eight, 30-minute sessions over a four-week period, of multisensory stimulation (MSE, treatment group) or relaxation activities (control group). MAIN OUTCOME MEASURES: Between-group comparisons for changes between assessment sessions for two behavioural assessments: Rehabilitation Evaluation--Hall and Baker (REHAB), Behaviour and Mood Disturbance Scale (BMD); a motor assessment: the dyskinesia section of the St Hans Rating Scale (SHRS); physiological measures: blood pressure, heart rate and respiratory rate. Secondary measures during intervention sessions included behavioural assessment using the Interact. RESULTS: There were no significant differences found between the groups for any main outcome measures made between sessions. The MSE group showed some positive effects within-sessions, with the Interact showing significant between-group differences in immediate effects on mood (p = 0.028). There was also a significantly different change over time for within-session changes in stimulation levels (p = 0.0002) and mood (p = 0.0001) between the groups. No physiological effects were observed in relation to sessions in either group. Two MSE subjects underwent changes in medication during the study period. CONCLUSIONS: There was no therapeutic effect of MSEs over the four-week study period. MSEs appear to be more effective thanconventional relaxation techniques as a leisure activity.


Assuntos
Doença de Huntington/reabilitação , Percepção , Limiar Sensorial , Afeto , Meio Ambiente , Humanos , Terapia de Relaxamento , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...