Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Water Res ; 47(4): 1666-78, 2013 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-23312671

RESUMO

Ongoing pollution and improving analytical techniques reveal more and more anthropogenic substances in drinking water sources, and incidentally in treated water as well. In fact, complete absence of any trace pollutant in treated drinking water is an illusion as current analytical techniques are capable of detecting very low concentrations. Most of the substances detected lack toxicity data to derive safe levels and have not yet been regulated. Although the concentrations in treated water usually do not have adverse health effects, their presence is still undesired because of customer perception. This leads to the question how sensitive analytical methods need to become for water quality screening, at what levels water suppliers need to take action and how effective treatment methods need to be designed to remove contaminants sufficiently. Therefore, in the Netherlands a clear and consistent approach called 'Drinking Water Quality for the 21st century (Q21)' has been developed within the joint research program of the drinking water companies. Target values for anthropogenic drinking water contaminants were derived by using the recently introduced Threshold of Toxicological Concern (TTC) approach. The target values for individual genotoxic and steroid endocrine chemicals were set at 0.01 µg/L. For all other organic chemicals the target values were set at 0.1 µg/L. The target value for the total sum of genotoxic chemicals, the total sum of steroid hormones and the total sum of all other organic compounds were set at 0.01, 0.01 and 1.0 µg/L, respectively. The Dutch Q21 approach is further supplemented by the standstill-principle and effect-directed testing. The approach is helpful in defining the goals and limits of future treatment process designs and of analytical methods to further improve and ensure the quality of drinking water, without going to unnecessary extents.


Assuntos
Água Potável/normas , Poluentes Químicos da Água/análise , Qualidade da Água/normas , Água Potável/química , Disruptores Endócrinos/análise , Países Baixos , Poluentes Químicos da Água/toxicidade , Purificação da Água/métodos
2.
J Chromatogr A ; 970(1-2): 167-81, 2002 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-12350091

RESUMO

Identification of unknown water pollutants with liquid chromatography and tandem mass spectrometry (LC-MS-MS) is often more complex and time consuming than identification with gas chromatography and mass spectrometry (GC-MS). In order to focus the identification effort on relevant compounds, unknown peaks need to be selected carefully. Based on its frequency of occurrence in the LC-Diode Array Detection (LC-DAD) chromatograms of surface and infiltrated waters, an unknown peak was selected for identification with LC-MS-MS. This compound was identified as hexamethoxymethylmelamine (HMMM), a chemical often used in the coating industry. This is the first time the presence of this chemical in surface waters has been reported. In addition to HMMM, two other structurally related compounds were found to be present in the investigated surface water. A standard mixture of HMMM and its by-products did not exhibit (geno)toxicity under the test conditions applied in this study. In another example, a genotoxic fraction of an industrial wastewater was isolated and examined by LC-MS-MS using a modern quadrupole-orthogonal acceleration-time-of-flight mass spectrometer (Q-TOF). Four compounds were detected. The structures of two compounds present are proposed to be 9-amino-2-hydroxy-acridine and 9-hydroxy-acridine-N-oxide or its structural isomer dihydroxy-acridine. Confirmation with standards could not be carried out, as pure compounds are not available. The other two compounds (structural isomers) could not be identified based on the data available within this study.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas/métodos , Testes de Mutagenicidade , Poluentes Químicos da Água/análise , Peso Molecular , Espectrofotometria Ultravioleta
3.
Environ Sci Technol ; 29(3): 553-61, 1995 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-22200262
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...