Int Orthop ; 39(11): 2205-13, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26381907

RESUMO

PURPOSE: The impacts of humeral offset and stem design after reverse shoulder arthroplasty (RSA) have not been well-studied, particularly with regard to newer stems which have a lower humeral inclination. The purpose of this study was to analyze the effect of different humeral stem designs on range of motion and humeral position following RSA. METHODS: Using a three-dimensional computer model of RSA, a traditional inlay Grammont stem was compared to a short curved onlay stem with different inclinations (155°, 145°, 135°) and offset (lateralised vs medialised). Humeral offset, the acromiohumeral distance (AHD), and range of motion were evaluated for each configuration. RESULTS: Altering stem design led to a nearly 7-mm change in humeral offset and 4 mm in the AHD. Different inclinations of the onlay stems had little influence on humeral offset and larger influence on decreasing the AHD. There was a 10° decrease in abduction and a 5° increase in adduction between an inlay Grammont design and an onlay design with the same inclination. Compared to the 155° model, the 135° model improved adduction by 28°, extension by 24° and external rotation of the elbow at the side by 15°, but led to a decrease in abduction of 9°. When the tray was placed medially, on the 145° model, a 9° loss of abduction was observed. CONCLUSIONS: With varus inclination prostheses (135° and 145°), elevation remains unchanged, abduction slightly decreases, but a dramatic improvement in adduction, extension and external rotation with the elbow at the side are observed.


Assuntos
Artroplastia de Substituição/métodos , Úmero/cirurgia , Articulação do Ombro/cirurgia , Simulação por Computador , Humanos , Imageamento Tridimensional , Prótese Articular , Desenho de Prótese , Amplitude de Movimento Articular , Rotação
2.
J Shoulder Elbow Surg ; 24(2): 295-301, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25168349

RESUMO

HYPOTHESIS: During total shoulder arthroplasty (TSA), humeral head subluxation may be difficult to manage. Furthermore, there is a risk for postoperative recurrence of subluxation, affecting the outcome of TSA. An accurate evaluation of the subluxation is necessary to evaluate this risk. Currently, subluxation is measured in 2 dimensions (2D), usually relative to the glenoid face. The goal of this study was to extend this measure to 3 dimensions (3D) to compare glenohumeral and scapulohumeral subluxation and to evaluate the association of subluxation with the glenoid version. MATERIALS AND METHODS: The study analyzed 112 computed tomography scans of osteoarthritic shoulders. We extended the usual 2D definition of glenohumeral subluxation, scapulohumeral subluxation, and glenoid version by measuring their orientation in 3D relative to the scapular plane and the scapular axis. We evaluated statistical associations between subluxation and version in 2D and 3D. RESULTS: Orientation of subluxation and version covered all sectors of the glenoid surface. Scapulohumeral subluxation and glenoid version were highly correlated in amplitude (R(2) = 0.71; P < .01) and in orientation (R(2) = 0.86; P < .01). Approximately every degree of glenoid version induced 1% of scapulohumeral subluxation in the same orientation of the version. Conversely, glenohumeral subluxation was not correlated to glenoid version in 2D or in 3D. CONCLUSIONS: Orientation of the humeral subluxation is rarely within the arbitrary computed tomography plane and should therefore be measured in 3D to detect out-of-plane subluxation. Scapulohumeral subluxation and glenoid version measured in 3D could bring valuable information for decision making during TSA.


Assuntos
Cabeça do Úmero/diagnóstico por imagem , Luxação do Ombro/diagnóstico por imagem , Articulação do Ombro/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Pontos de Referência Anatômicos/diagnóstico por imagem , Artroplastia de Substituição , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/complicações , Osteoartrite/diagnóstico por imagem , Osteoartrite/cirurgia , Período Pós-Operatório , Estudos Retrospectivos , Luxação do Ombro/complicações , Luxação do Ombro/cirurgia , Tomografia Computadorizada por Raios X
3.
Biomaterials ; 35(37): 9995-10006, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25241159

RESUMO

Bisphosphonates are known for their strong inhibitory effect on bone resorption. Their influence on bone formation however is less clear. In this study we investigated the spatio-temporal effect of locally delivered Zoledronate on peri-implant bone formation and resorption in an ovariectomized rat femoral model. A cross-linked hyaluronic acid hydrogel was loaded with the drug and applied bilaterally in predrilled holes before inserting polymer screws. Static and dynamic bone parameters were analyzed based on in vivo microCT scans performed first weekly and then biweekly. The results showed that the locally released Zoledronate boosted bone formation rate up to 100% during the first 17 days after implantation and reduced the bone resorption rate up to 1000% later on. This shift in bone remodeling resulted in an increase in bone volume fraction (BV/TV) by 300% close to the screw and 100% further away. The double effect on bone formation and resorption indicates a great potential of Zoledronate-loaded hydrogel for enhancement of peri-implant bone volume which is directly linked to improved implant fixation.


Assuntos
Conservadores da Densidade Óssea/administração & dosagem , Conservadores da Densidade Óssea/uso terapêutico , Reabsorção Óssea/tratamento farmacológico , Difosfonatos/administração & dosagem , Difosfonatos/uso terapêutico , Imidazóis/administração & dosagem , Imidazóis/uso terapêutico , Osteogênese/efeitos dos fármacos , Animais , Densidade Óssea/efeitos dos fármacos , Reabsorção Óssea/fisiopatologia , Parafusos Ósseos , Sistemas de Liberação de Medicamentos , Feminino , Fêmur/efeitos dos fármacos , Fêmur/fisiologia , Fêmur/fisiopatologia , Hidrogel de Polietilenoglicol-Dimetacrilato/química , Ratos , Ácido Zoledrônico