Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Urology ; 48(5): 794-6, 1996 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-8911531

RESUMO

Testicular microlithiasis is an uncommon condition in which multiple calcifications develop in the seminiferous tubules. Sonography demonstrates a typical pattern of diffuse, hyperechoic specks. This condition has been associated with premalignant and malignant changes of the testicle. We present a case of intratubular germ cell neoplasia and a microscopic focus of seminoma found in a patient with isolated testicular microlithiasis and no focal mass. Physicians should be more aware of testicular microlithiasis, and heightened surveillance is recommended to identify progression to tumor formation.


Assuntos
Cálculos/complicações , Germinoma/complicações , Seminoma/complicações , Doenças Testiculares/complicações , Neoplasias Testiculares/complicações , Adulto , Cálculos/patologia , Humanos , Masculino , Doenças Testiculares/patologia
2.
Clin Chem ; 36(1): 115-8, 1990 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-2297900

RESUMO

We assessed the performance of three commercially available polyclonal immunoassays for apparent cyclosporine in 120 whole-blood specimens collected from transplant recipients just before their next dose of cyclosporine (CsA). The assays were (a) Abbott's TDx fluorescent polarization immunoassay for CsA and its metabolites in whole blood; (b) the Sandoz radioimmunoassay (RIA); and (c) Incstar's Cyclo-Trac RIA. Mean respective CVs were 3.8%, 9.3%, and 24.3%. Analytical recovery was nearly 100% for concentrations up to 1000 micrograms/L for Incstar and up to 1500 micrograms/L for Abbott and Sandoz; linearity was compromised at greater concentrations. We also quantified the parent CsA concentrations by HPLC. Moreover, to follow day-to-day fluctuations in patients' "cyclosporine" concentrations with each method and to assess the impact these differences have on interpretation of the analytical results, we assayed serial specimens from six post-transplant patients. These showed significantly dissimilar, but parallel, results among the methods for any single sample. Occasionally, however, a result would not fit the established trend. Biases observed among the assays can be explained in part by the nonspecific antisera cross-reacting with CsA metabolites. Most important, we demonstrate that patients' results are not reliably interchangeable among the methods.


Assuntos
Ciclosporinas/sangue , Análise de Variância , Química Clínica/normas , Cromatografia Líquida de Alta Pressão , Reações Cruzadas , Ciclosporinas/normas , Polarização de Fluorescência , Seguimentos , Humanos , Radioimunoensaio , Kit de Reagentes para Diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...