Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Total Environ ; 866: 161257, 2023 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-36608822

RESUMO

Continuous consumption combined with incomplete removal during wastewater treatment means residues of psychoactive substances (licit drugs, medications of abuse and illicit drugs) are constantly introduced into the aquatic environment, where they have the potential to affect non-target organisms. In this study, 17 drug residues of psychoactive substances were determined in wastewater influent, effluent and in receiving rivers of six Slovene municipal wastewater treatment plants employing different treatment technologies. Variations in removal efficiencies (REs) during spring, summer and winter were explored, and ecotoxic effects were evaluated using in silico (Ecological Structure-Activity Relationships software-ECOSAR) and in vivo (algal growth inhibition test) methods. Drug residues were detected in influent and effluent in the ng/L to µg/L range. In receiving rivers, biomarkers were in the ng/L range, and there was good agreement between measured and predicted concentrations. On average, REs were highest for nicotine, 11-nor-9-carboxy-∆9-tetrahydrocannabinol (THC-COOH), cocaine residues, and amphetamine (>90 %) and lowest for methadone residues (<30 %). REs were comparable between treatments involving activated sludge and membrane bioreactors, while the moving biofilm bed reactor (MBBR) removed cotinine, cocaine, and benzoylecgonine to a lesser extent. Accordingly, higher levels of nicotine and cocaine residues were detected in river water receiving MBBR discharge. Although there were seasonal variations in REs and levels of drug residues in receiving rivers, no general pattern could be observed. No significant inhibition of algal growth (Chlamydomonas reinhardtii) was observed for the tested compounds (1 mg/L) during 72 h and 240 h of exposure, although effects on aquatic plants were predicted in silico. In addition, environmental risk assessment revealed that levels of nicotine, methadone, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), morphine, and 3,4-methylenedioxymethamphetamine (MDMA) pose a risk to aquatic organisms. Since nicotine and EDDP can have acute and chronic effects, the authors support regular monitoring of receiving surface waters, followed up by regulatory actions.


Assuntos
Cocaína , Poluentes Químicos da Água , Purificação da Água , Eliminação de Resíduos Líquidos/métodos , Rios/química , Nicotina , Biofilmes , Poluentes Químicos da Água/análise , Monitoramento Ambiental , Reatores Biológicos , Anfetamina , Fármacos do Sistema Nervoso Central , Dronabinol/análise , Cocaína/análise , Metadona
2.
Water Sci Technol ; 76(7-8): 2188-2194, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29068348

RESUMO

Wastewater from washing, oil separators, the metal processing and detergent industries, was tested and treated for treatment of different types of liquid waste at industrial level at Domzale-Kamnik Wastewater Treatment Plant (WWTP). The effect of implementing the electrocoagulation (EC) and flotation processes, respectively, is analysed and includes the duration of the EC implementation, voltage, number of electrodes, and chemical addition, as well as the pH effect and conductivity. The tests were performed not only on various types of liquid waste, but also on different mixtures of liquid waste. Laboratory analysis of the samples before and after EC have shown an effective reduction not only in organic loads in accordance with the COD (chemical oxygen demand) parameter, but also in mineral oil content, toxic metal concentration, and surfactants. The COD in liquid waste from the detergent industry was reduced by 73% and the content of surfactants by 64%. In liquid waste from the metal processing industry, the COD decreased by up to 95%, while the content of toxic metals decreased from 59 to 99%. Similar phenomena were shown in liquid waste from oil separators, where the COD was reduced to 33% and the concentration of mineral oils by 99%. Some of the liquid wastes were mixed together in the ratio 1:1, thus allowing testing of the operation of EC technology in heterogeneous liquid waste, where the final result proved to be effective cleaning as well. After treatment in the process of EC, the limit values of the treated water proved appropriate for discharge into the sewerage system.


Assuntos
Técnicas Eletroquímicas/métodos , Resíduos Industriais/análise , Eliminação de Resíduos Líquidos/métodos , Purificação da Água/métodos , Análise da Demanda Biológica de Oxigênio , Eletrodos , Instalações Industriais e de Manufatura , Metais/análise , Águas Residuárias/química
3.
Environ Sci Pollut Res Int ; 23(15): 14692-704, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26169820

RESUMO

The results of an inter-laboratory comparison exercise to determine cytostatic anticancer drug residues in surface water, hospital wastewater and wastewater treatment plant effluent are reported. To obtain a critical number of participants, an invitation was sent out to potential laboratories identified to have the necessary knowledge and instrumentation. Nine laboratories worldwide confirmed their participation in the exercise. The compounds selected (based on the extent of use and laboratories capabilities) included cyclophosphamide, ifosfamide, 5-fluorouracil, gemcitabine, etoposide, methotrexate and cisplatinum. Samples of spiked waste (hospital and wastewater treatment plant effluent) and surface water, and additional non-spiked hospital wastewater, were prepared by the organising laboratory (Jozef Stefan Institute) and sent out to each participant partner for analysis. All analytical methods included solid phase extraction (SPE) and the use of surrogate/internal standards for quantification. Chemical analysis was performed using either liquid or gas chromatography mass (MS) or tandem mass (MS/MS) spectrometry. Cisplatinum was determined using inductively coupled plasma mass spectrometry (ICP-MS). A required minimum contribution of five laboratories meant that only cyclophosphamide, ifosfamide, methotrexate and etoposide could be included in the statistical evaluation. z-score and Q test revealed 3 and 4 outliers using classical and robust approach, respectively. The smallest absolute differences between the spiked values and the measured values were observed in the surface water matrix. The highest within-laboratory repeatability was observed for methotrexate in all three matrices (CV ≤ 12 %). Overall, inter-laboratory reproducibility was poor for all compounds and matrices (CV 27-143 %) with the only exception being methotrexate measured in the spiked hospital wastewater (CV = 8 %). Random and total errors were identified by means of Youden plots.


Assuntos
Antineoplásicos/análise , Monitoramento Ambiental/métodos , Poluentes Químicos da Água/análise , Cromatografia Líquida/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos
4.
Food Environ Virol ; 2015 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-25663146

RESUMO

Waste water treatment plant (WWTP) is considered as an important source of surface water contamination by enteric pathogens. In this study, we describe the occurrence of enteric viruses (group A rotaviruses, noroviruses, astroviruses, sapoviruses, hepatitis A virus, and hepatitis E virus) and Clostridium difficile in the effluent of a wastewater treatment plant during a 1-year period. Enteric viruses were simultaneously and efficiently concentrated in a single step using methacrylate monolithic chromatographic support. Rotaviruses, noroviruses (genogroup I and II), and sapoviruses were detected in all 12 concentrated samples, whereas astroviruses were not detected in August and September and hepatitis A and E viruses were not detected at all. Clostridium difficile was detected in all samples and altogether 121 strains were isolated and grouped into 32 different ribotypes of which 014/020 and 010 were most prevalent. Pathogens detected in WWTP effluent partially reflect the epidemiological situation of enteric viruses and C. difficile in human population and open the discussion on implementation of possible techniques for virus and bacteria removal from WWTP effluent prior to release into the surface water system.

5.
Ultrason Sonochem ; 26: 408-414, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25596776

RESUMO

The disintegration of raw sludge is very important for enhancement of the biogas production in anaerobic digestion process as it provides easily degradable substrate for microorganisms to perform maximum sludge treatment efficiency and stable digestion of sludge at lower costs. In the present study the disintegration was studied by using a novel rotation generator of hydrodynamic cavitation (RGHC). At the first stage the analysis of hydrodynamics of the RGHC were made with tap water, where the cavitation extent and aggressiveness was evaluated. At the second stage RGHC was used as a tool for pretreatment of a waste-activated sludge (WAS), collected from wastewater treatment plant (WWTP). In case of WAS the disintegration rate was measured, where the soluble chemical oxygen demand (SCOD) and soluble Kjeldahl nitrogen were monitored and microbiological pictures were taken. The SCOD increased from initial 45 mg/L up to 602 mg/L and 12.7% more biogas has been produced by 20 passes through RGHC. The results were obtained on a pilot bioreactor plant, volume of 400 L.


Assuntos
Hidrodinâmica , Esgotos/química , Eliminação de Resíduos Líquidos/métodos , Estudos de Viabilidade , Rotação , Eliminação de Resíduos Líquidos/economia , Eliminação de Resíduos Líquidos/instrumentação
6.
Ultrason Sonochem ; 21(3): 1213-21, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24286658

RESUMO

In this study, the removal of clofibric acid, ibuprofen, naproxen, ketoprofen, carbamazepine and diclofenac residues from wastewater, using a novel shear-induced cavitation generator has been systematically studied. The effects of temperature, cavitation time and H2O2 dose on removal efficiency were investigated. Optimisation (50°C; 15 min; 340 mg L(-1) of added H2O2) resulted in removal efficiencies of 47-86% in spiked deionised water samples. Treatment of actual wastewater effluents revealed that although matrix composition reduces removal efficiency, this effect can be compensated for by increasing H2O2 dose (3.4 g L(-1)) and prolonging cavitation time (30 min). Hydrodynamic cavitation has also been investigated as either a pre- or a post-treatment step to biological treatment. The results revealed a higher overall removal efficiency of recalcitrant diclofenac and carbamazepine, when hydrodynamic cavitation was used prior to as compared to post biological treatment i.e., 54% and 67% as compared to 39% and 56%, respectively. This is an important finding since diclofenac is considered as a priority substance to be included in the EU Water Framework Directive.


Assuntos
Cidades , Hidrodinâmica , Fenômenos Mecânicos , Preparações Farmacêuticas/isolamento & purificação , Águas Residuárias/química , Poluentes Químicos da Água/isolamento & purificação , Purificação da Água/métodos , Peróxido de Hidrogênio/química , Temperatura , Fatores de Tempo
7.
Water Sci Technol ; 53(4-5): 125-32, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16722062

RESUMO

In the paper three linear aeration controllers that can be easily implemented are presented and evaluated on the activated sludge process pilot plant. Controllers differ according to the information that is used about the process, which can be oxygen in the last aerobic reactor, ammonia in the last aerobic reactor and ammonia in the influent. The aeration controllers that are addressed are: oxygen cascade PI controller, ammonia cascade PI controller and ammonia feedforward-cascade PI controller. Experiments show that, in comparison with the oxygen cascade PI controller, the ammonia cascade PI controller allows better control of effluent ammonia and airflow savings of around 23%, while the ammonia feedforward-cascade PI controller gives the best reduction of ammonia peaks and can save up to 45% of the airflow.


Assuntos
Amônia/isolamento & purificação , Eliminação de Resíduos Líquidos/instrumentação , Aerobiose , Movimentos do Ar , Reatores Biológicos , Retroalimentação , Sistemas On-Line , Oxigênio/análise , Esgotos , Software , Eliminação de Resíduos Líquidos/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...