Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 105
Filtrar
1.
Int J Med Inform ; 83(8): 581-91, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24915863

RESUMO

BACKGROUND: The role of nursing home (NH) information technology (IT) in quality improvement has not been clearly established, and its impacts on communication between care givers and patient outcomes in these settings deserve further attention. OBJECTIVES: In this research, we describe a mixed method approach to explore communication strategies used by healthcare providers for resident skin risk in NH with high IT sophistication (ITS). METHODS: Sample included NH participating in the statewide survey of ITS. We incorporated rigorous observation of 8- and 12-h shifts, and focus groups to identify how NH IT and a range of synchronous and asynchronous tools are used. Social network analysis tools and qualitative analysis were used to analyze data and identify relationships between ITS dimensions and communication interactions between care providers. RESULTS: Two of the nine ITS dimensions (resident care-technological and administrative activities-technological) and total ITS were significantly negatively correlated with number of unique interactions. As more processes in resident care and administrative activities are supported by technology, the lower the number of observed unique interactions. Additionally, four thematic areas emerged from staff focus groups that demonstrate how important IT is to resident care in these facilities including providing resident-centered care, teamwork and collaboration, maintaining safety and quality, and using standardized information resources. CONCLUSION: Our findings in this study confirm prior research that as technology support (resident care and administrative activities) and overall ITS increases, observed interactions between staff members decrease. Conversations during staff interviews focused on how technology facilitated resident centered care through enhanced information sharing, greater virtual collaboration between team members, and improved care delivery. These results provide evidence for improving the design and implementation of IT in long term care systems to support communication and associated resident outcomes.


Assuntos
Redes de Comunicação de Computadores/organização & administração , Sistemas de Informação/estatística & dados numéricos , Comunicação Interdisciplinar , Casas de Saúde/organização & administração , Medição de Risco/métodos , Higiene da Pele , Grupos Focais , Humanos , Melhoria de Qualidade
2.
Comput Inform Nurs ; 32(8): 378-87; quiz 388-9, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24818790

RESUMO

National leaders are calling for opportunities to facilitate the Future of Nursing. Opportunities can be encouraged through state nurses association Web sites, which are part of the American Nurses Association, that are well designed, with appropriate content, and in a language professional nurses understand. The American Nurses Association and constituent state nurses associations provide information about nursing practice, ethics, credentialing, and health on Web sites. We conducted usability evaluations to determine compliance with heuristic and ethical principles for Web site design. We purposefully sampled 27 nursing association Web sites and used 68 heuristic and ethical criteria to perform systematic usability assessments of nurse association Web sites. Web site analysis included seven double experts who were all RNs trained in usability analysis. The extent to which heuristic and ethical criteria were met ranged widely from one state that met 0% of the criteria for "help and documentation" to states that met greater than 92% of criteria for "visibility of system status" and "aesthetic and minimalist design." Suggested improvements are simple yet make an impact on a first-time visitor's impression of the Web site. For example, adding internal navigation and tracking features and providing more details about the application process through help and frequently asked question documentation would facilitate better use. Improved usability will improve effectiveness, efficiency, and consumer satisfaction with these Web sites.


Assuntos
American Nurses' Association/organização & administração , Estudos de Avaliação como Assunto , Internet/normas , Design de Software , Interface Usuário-Computador , Humanos , Enfermeiras e Enfermeiros , Estados Unidos
3.
Vasa ; 35(3): 191-4, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16941409

RESUMO

Two patients with subclavian vein thrombosis are presented in which a balloon venoplasty led to recanalization of the subclavian vein and complete remission of clinical symptoms. In patients with extreme symptoms and unsuccessful initial catheter-directed local thrombolysis, this non-operative approach can be considered despite known favourable spontaneous outcome of subclavian vein thrombosis.


Assuntos
Angioplastia com Balão , Síndrome do Roubo Subclávio/terapia , Trombose/terapia , Doença Aguda , Adulto , Braço/irrigação sanguínea , Seguimentos , Humanos , Isquemia/diagnóstico por imagem , Isquemia/terapia , Masculino , Flebografia , Retratamento , Síndrome do Roubo Subclávio/diagnóstico por imagem , Terapia Trombolítica , Trombose/diagnóstico por imagem , Falha de Tratamento , Ultrassonografia Doppler Dupla , Ativador de Plasminogênio Tipo Uroquinase/administração & dosagem
4.
Radiat Prot Dosimetry ; 117(1-3): 50-3, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16461528

RESUMO

Radiation risk has to be justified and optimised. This study discusses the radiation risk of uterine artery embolisation (UAE) for the treatment of fibroids. A total of 70 consecutive UAE dosimetry parameters were assessed. Using Monte Carlo simulation, organ and effective doses and dose conversion coefficients (DCCs) (mSv Gy cm(-2)) were calculated. During UAE optimisation, avoidance of oblique views and use of last-image-hold (LIH) documentation instead of digital subtraction angiography (DSA) were investigated. Mean dose-area product (DAP) was 37.1 Gy cm2 (median 23.7 Gy cm2) and mean fluoroscopy time was 18.4 min (median 16.6 min). Dose values decreased as the study progressed: mean DAP for patients 1-21, 68.5 Gy cm2; patients 22-43, 35.7 Gy cm2; and patients 44-69, 13.0 Gy cm2. Average DCC for DSA image procedures was 0.572, yielding a mean effective dose of 29.6 mSv (median 17.1 mSv). For LIH-only procedures, an average DCC of 0.813 was estimated [using mean effective dose: 10.6 mSv (median 8.1 mSv)].


Assuntos
Artérias/patologia , Embolização Terapêutica/métodos , Leiomioma/radioterapia , Radiometria/métodos , Doenças Uterinas/radioterapia , Adulto , Índice de Massa Corporal , Relação Dose-Resposta à Radiação , Feminino , Fluoroscopia/métodos , Humanos , Pessoa de Meia-Idade , Fatores de Tempo
5.
Eur Radiol ; 14(5): 842-8, 2004 May.
Artigo em Inglês | MEDLINE | ID: mdl-14551727

RESUMO

The goal of this study was estimation of patient effective dose from uterine artery embolization of leiomyomata. Parameters and data relevant to patient dose were recorded for 33 consecutive procedures. Using Monte Carlo simulation of radiation transport, organ and effective doses were calculated in detail for a subset of five procedures, to estimate the effective dose for all procedures. Mean dose area product was 59.9, median 23.4, and range 8.8-317.5 Gycm(2). Mean absorbed ovarian dose was calculated as 51 mGy in the five procedures. Using the dose conversion factor estimated from the Monte Carlo simulation for all procedures a mean estimated effective dose of 34 mSv (median 13 mSv, range 5-182 mSv) results, with a tendency to lower values regarding the succession of the procedures. Patients' radiation exposure level is up to twice of that of an abdominal CT examination. Angiographic equipment related dose-reducing features and radiographic technique essentially influence organ doses and effective dose. Consistent application of dose-reducing techniques and awareness of radiation exposure justifies uterine artery embolization as a therapeutic option for the treatment of uterine fibroids.


Assuntos
Embolização Terapêutica/métodos , Leiomioma/terapia , Neoplasias Uterinas/terapia , Útero/efeitos da radiação , Adulto , Artérias/efeitos da radiação , Relação Dose-Resposta à Radiação , Embolização Terapêutica/efeitos adversos , Feminino , Humanos , Pessoa de Meia-Idade , Método de Monte Carlo , Imagens de Fantasmas , Doses de Radiação , Útero/irrigação sanguínea
6.
Water Sci Technol ; 45(7): 65-73, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-11989894

RESUMO

The Urban Water Resources Research Council of the American Society of Civil Engineers, under a cooperative agreement with the US Environmental Protection Agency, released Version 1.0 of the National Stormwater Best Management Practices (BMP) Database to the stormwater management community in 1999. The product included a loaded database of 71 BMPs, as well as data entry software for standardized reporting of BMP test data. In conjunction with the database, the project team developed BMP performance evaluation protocols and applied them to the data contained in the initial database. Since the initial database release, 42 new BMP data sets have been added to the database, which is now accessible via the Internet at www.bmpdatabase.org along with associated data evaluation reports and other project documentation. A national stormwater BMP data clearinghouse continues to screen and post new BMP data to the database, as well as respond to inquiries from the public. An overview of both of the database software and results of the data evaluation are provided in this paper.


Assuntos
Bases de Dados Factuais , Chuva , Poluição da Água/prevenção & controle , Abastecimento de Água , Engenharia , Desenvolvimento de Programas , Avaliação de Programas e Projetos de Saúde , Software , Movimentos da Água
7.
Radiat Prot Dosimetry ; 94(1-2): 33-6, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11487839

RESUMO

In clinical radiological practice two main questions regarding image quality have to be looked at: Which degree of image quality is needed? and: How can this image quality be objective? Image quality requirements depend on size, density and contrast of the objects of interest and on the clinical question which has to be answered. In comparison to conventional radiography, the digital radiographic techniques offer additional features concerning optimisation of image quality and dose, like a wider dynamic range, digital fluoroscopic techniques and post-processing. Therefore it is necessary to define new quality criteria for these techniques. In the following, typical examples demonstrate the development of the 'Diagnostic Requirements for Digital Radiographic Procedures'. These examinations include projection radiographs with digital luminiscent radiography, fluoroscopic procedures with digital image intensifier radiography and angiographic procedures with digital subtraction angiography. The clinical question of a radiological examination also forms the background to optimisation strategies considering image quality and radiation dose.


Assuntos
Intensificação de Imagem Radiográfica/normas , União Europeia , Fluoroscopia , Humanos , Intestino Delgado/diagnóstico por imagem , Controle de Qualidade , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Radiografia Torácica/normas
8.
Cardiovasc Intervent Radiol ; 24(3): 168-75, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11443404

RESUMO

PURPOSE: To evaluate the safety and efficacy of stent therapy for the treatment of residual stenoses after percutaneous transluminal angioplasty (PTA) of popliteal stenoses and occlusions. METHODS: In a prospective single-center study, flexible tantalum stents were implanted in 32 popliteal arteries for the treatment of residual stenosis greater than 50% after PTA of stenoses (n = 17) or occlusions (n = 15) in the P1 (n = 16), the P2 (n = 13), or both P1 and P2 segment (n = 3). Follow-up patency was assessed by clinical examination, ankle-brachial index, and color Doppler sonography or angiography. RESULTS: Early stent thrombosis (10 days): 1 of 32 arteries (3%). 1-year and 2-year primary patency rate (PPR): 81% +/- 7.1% and 74% +/- 9.1%, respectively. 1-year PPRs for subgroups: stented stenoses versus stented occlusions: 88% +/- 7.8% vs 73% +/- 12.0%, p = 0.12; good lower limb runoff versus poor: 84.0% +/- 8.7% vs 76.0% +/- 12.4; p = 0.09; P1 versus P2: 77.3% +/- 9.8% vs 85.7% +/- 9.4%, p = 0.38. Recurrent PTA lesions treated with stents showed higher restenosis rate than de novo lesions. CONCLUSION: The results of stent therapy of residual popliteal stenosis after PTA are encouraging and warrant further investigation.


Assuntos
Arteriopatias Oclusivas/terapia , Oclusão de Enxerto Vascular/terapia , Artéria Poplítea/cirurgia , Stents , Tantálio , Idoso , Idoso de 80 Anos ou mais , Angioplastia com Balão , Arteriopatias Oclusivas/diagnóstico por imagem , Estudos de Coortes , Feminino , Oclusão de Enxerto Vascular/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia , Ultrassonografia
9.
Eur Radiol ; 10(7): 1144-51, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-11003412

RESUMO

The aim of this study was to determine long-term success of flexible tantalum stents for the treatment of ostial and truncal renal artery stenosis. Since 1989, flexible tantalum stents (type Strecker) were implanted in 34 patients (36 arteries, 25 ostial lesions, 11 truncal lesions) with uncontrollable renovascular hypertension, 9 of them in association with renal insufficiency. Stents were placed unilaterally in 32 patients, and bilaterally in 2 patients for the treatment of renal artery stenosis. Thirty-five of 36 lesions were atherosclerotic, including 5 recurrencies after previous percutaneous transluminal renal angioplasty (PTRA). One patient had Takayasu arteritis. Stents were implanted after unsuccessful PTRA of 11 truncal and 23 ostial lesions, and as a primary procedure in 2 ostial lesions. Follow-up examinations included blood pressure measurement, determination of serum creatinine level, color duplex sonography, or angiography. The technical success rate was 92%. Technical failure included incorrect stent placement (1 of 36 lesions, 2.8 % ), and stent dislocation (2 of 36 lesions, 5.6 %), and two stents were retrieved percutaneously. In one case of Takayasu arteritis, residual stenosis of 40% was observed. After technically successful stent placement, 77% of patients became normotensive with or without medication. In the remaining patients there was partial improvement with blood pressure between 140 and 180 mmHg. Renal function improved in 76% of patients (completely in 3 of 8, 38%; and partially in 3 of 8, 38%). Primary patency rate including all stented lesions and initial technical failures was 82.4% +/- 6.8 (1 year) and 82.4% +/- 9.2 (3 years). After technically successful stent placement, patency rates were 89.9 +/- 5.6% (1 year), and 89.9 +/- 7.6% (3 years). For ostial lesions, primary patency rate was 87.9 +/- 6.7% (1 year) and 87.9 +/- 9.2% (3 years). Placement of flexible tantalum stents in renal arteries is technically demanding, especially in ostial lesions. Once placed successfully stent patency rate is excellent.


Assuntos
Hipertensão Renovascular/cirurgia , Stents , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tantálio , Fatores de Tempo
10.
J Vasc Interv Radiol ; 11(1): 83-8, 2000 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-10693718

RESUMO

PURPOSE: To evaluate the current practice of temporary vena cava filter placement and its complications. MATERIALS AND METHODS: A multicenter registry was conducted from May 1995 until May 1997 using a standardized questionnaire. One hundred eighty-eight patients were evaluated. Patient characteristics, filter indications, filter characteristics, and complications were registered. RESULTS: Deep vein thrombosis was proven in 95.2% of the patients. Main filter indication was thrombolysis therapy (53.1%). Average filter time was 5.4 days. An Antheor filter was inserted in 56.4%, a Guenther filter in 26.6%, and a Prolyser filter in 17.%. Transfemoral filter implantation was slightly preferred (54.8%). Four patients died of pulmonary embolism (PE) during filter protection. Major filter problems were filter thrombosis (16%) and filter dislocation (4.8%). When thrombus was found in or at the filter before explantation, additional thrombolysis was performed in 16.7%, additional filter implantation in 10%, and thrombus aspiration in 6.7%; 4.8% of filters were replaced with permanent filters. DISCUSSION: Temporary vena cava filters are placed to prevent PE in a defined patient population. Despite their presence, PEs still occur in a small percentage. Problems of filter thrombosis and dislocation have to be solved. CONCLUSION: The results of this multicenter registry support the need for innovative filter design, as well as a randomized, prospective study.


Assuntos
Filtros de Veia Cava/estatística & dados numéricos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Embolia Pulmonar/prevenção & controle , Sistema de Registros , Terapia Trombolítica , Filtros de Veia Cava/efeitos adversos
11.
Cardiovasc Intervent Radiol ; 23(6): 447-51, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-11232892

RESUMO

PURPOSE: To evaluate the angiographic and clinical effects of percutaneous transluminal angioplasty (PTA) of distal ostial collateral stenoses in patients with claudication and long-segment occlusion of the superficial femoral artery (SFA). METHODS: In ten patients (9 men, 1 woman) with stable intermittent claudication due to chronic long-segment occlusion of the SFA a high-grade stenosis of the distal collateral ostium of the deep femoral artery to the popliteal artery were dilated. PTA was performed using popliteal artery access. Claudication distances on the treadmill and ankle-brachial pressure indices (ABI) at rest were analyzed before, 1 week, and 14 weeks after PTA. RESULTS: Initial technical success was obtained in all patients. There were no significant periprocedural local complications. The initial mean claudication distance on the treadmill increased significantly from 107 +/- 65 m to 306 +/- 209 m (p < 0.01), the maximal claudication distance from 203 +/- 128 m to 392 +/- 167 m (p < 0.01). The mean ABI changed slightly but significantly (0.61 +/- 0.08 vs. 0.64 +/- 0.07; p < 0.05). Early follow-up after 14 weeks revealed no clinical deterioration. CONCLUSION: This new technique is considered helpful in patients with well-defined claudication and long-segment occlusion of the SFA.


Assuntos
Angioplastia com Balão , Artéria Femoral , Claudicação Intermitente/fisiopatologia , Artéria Poplítea , Recuperação de Função Fisiológica , Idoso , Angiografia , Arteriopatias Oclusivas/complicações , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/terapia , Pressão Sanguínea , Teste de Esforço , Feminino , Artéria Femoral/diagnóstico por imagem , Humanos , Claudicação Intermitente/diagnóstico por imagem , Claudicação Intermitente/etiologia , Masculino , Pessoa de Meia-Idade , Artéria Poplítea/diagnóstico por imagem , Prognóstico , Recuperação de Função Fisiológica/fisiologia , Estudos Retrospectivos
12.
Cardiovasc Intervent Radiol ; 23(6): 480-1, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-11232900

RESUMO

A 16-year-old female patient with recurrent stenosis after unilateral choanal atresia that had been treated by surgery and laser therapy presented with restenosis 3 weeks after laser resection. As an alternative to repeat surgery, she was treated by balloon dilatation. Four balloon dilatations were performed (three at 4-week intervals and the last after an 8-week interval) over a 4-month period on an outpatient basis. She tolerated the treatment well without any complications. Over a follow-up period of 2 years the choana has remained completely open. The balloon dilatation described in this context here for the first time may be a good alternative to repeated operations in the treatment of recurrent choanal atresia, with minimal stress to the patient.


Assuntos
Cateterismo , Atresia das Cóanas/terapia , Adolescente , Cateterismo/métodos , Atresia das Cóanas/complicações , Atresia das Cóanas/diagnóstico por imagem , Feminino , Humanos , Obstrução Nasal/diagnóstico por imagem , Obstrução Nasal/etiologia , Obstrução Nasal/terapia , Prognóstico , Radiografia , Recidiva
13.
Vasc Med ; 4(4): 247-51, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10613629

RESUMO

The aim of the study was to determine whether hemodynamic and functional variables are related to the angiographic extent of lower limb atherosclerosis. In 150 patients with stable intermittent claudication, the Bollinger angiogram score was compared with the resting Doppler pressure values, and the initial claudication distance (ICD) and absolute claudication distance (ACD) with treadmill exercise. The extent of lower limb atherosclerosis correlated significantly with the age of the patients and the duration of the claudication. The angiogram scores of the patients were negatively correlated with the ankle systolic blood pressure (SBP) and the ankle/brachial index (ABI). In a multiple regression analysis, ABI was the most predictive variable for the angiographic severity of disease. ICD, ACD and work on the treadmill failed to correlate with the angiogram summation score. If patients were classified into groups for those with iliac or femoropopliteal disease, a weak correlation between ACD and femoropopliteal angiogram score was found. The comparison between Doppler measurements and treadmill exercise testing showed no significant correlation between SBP/ABI of the more diseased limb and ICD. However, both SBP and ABI did correlate significantly with ACD (r = 0.16, p < 0.05 and r = 0.20, p < 0.01, respectively). In conclusion, SBP and ABI are reliable parameters for indirect assessment of the angiographic extent of lower limb atherosclerosis. In contrast, the walking capacity of claudicant patients is independent of the angiographic severity of the disease.


Assuntos
Angiografia , Hemodinâmica/fisiologia , Claudicação Intermitente/diagnóstico por imagem , Claudicação Intermitente/fisiopatologia , Perna (Membro)/irrigação sanguínea , Fatores Etários , Idoso , Tornozelo/irrigação sanguínea , Pressão Sanguínea , Teste de Esforço , Feminino , Artéria Femoral/fisiopatologia , Humanos , Artéria Ilíaca/fisiopatologia , Masculino , Pessoa de Meia-Idade , Artéria Poplítea/fisiopatologia , Análise de Regressão , Índice de Gravidade de Doença
14.
Cardiovasc Intervent Radiol ; 22(6): 493-8, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10556409

RESUMO

PURPOSE: Evaluation of short- and extended-term results of repeated epidural/perineural injections (EDT/PRT) of corticoids in painful afflictions of the lumbar spine. METHODS: Thirty-two patients who had persistent radicular or low back pain for more than 6 weeks were treated with CT-guided injection therapy. By EDT/PRT, 40 mg of triamcinolonacetonid was injected either periradicularly or by a direct intraspinal epidural method at intervals of 3 weeks. Altogether, 140 EDT/PRT were performed in 32 patients (mean 4.4, range 2-8). In nine patients partial facet joint denervation with 1-2 ml of 50% alcohol solution was combined with EDT/PRT to reduce low back pain. Before and after treatment and at follow-up (mean 9.6 months), treatment success was evaluated on a visual analog scale and by physical examination (good = >50% improvement, moderate = 20%-50%, no improvement = <20%). RESULTS: Short-term (end of therapy) good or moderate improvement was achieved in 91% of patients, extended-term (mean 9.6 months) in 56%. Regarding certain subgroups, those with disc herniations of the lumbar spine showed a better outcome with good or moderate improvement in 95% short-term and 69% extended-term than those with spinal stenosis who had 72% short-term and 28% long-term. CONCLUSION: Results indicate that CT-guided EDT/PRT in combination with partial facet joint denervation is a safe and effective outpatient treatment.


Assuntos
Anti-Inflamatórios/uso terapêutico , Deslocamento do Disco Intervertebral/tratamento farmacológico , Vértebras Lombares , Estenose Espinal/tratamento farmacológico , Triancinolona/uso terapêutico , Anti-Inflamatórios/administração & dosagem , Feminino , Seguimentos , Humanos , Injeções Epidurais , Injeções Espinhais , Deslocamento do Disco Intervertebral/fisiopatologia , Masculino , Pessoa de Meia-Idade , Medição da Dor , Estenose Espinal/fisiopatologia , Tomografia Computadorizada por Raios X , Triancinolona/administração & dosagem
15.
Rofo ; 170(1): 84-8, 1999 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-10071650

RESUMO

PURPOSE: In clinical prospective trials, we examined the effect of the low molecular weight heparin (lmwh) reviparin on restenosis rate after Strecker stent implantation in femoral popliteal arteries. MATERIALS AND METHODS: 62 patients were treated between 1992 and 1998. Patients received reviparin, 3500 IU, prior to stent implantation followed by 7500 IU for 24 h (i.v.) and 2 x 1750 IU/day s.c. over three weeks (n = 12) or 10,500 IU for 24 h (i.v.) and 2 x 3500 IU/day s.c. over 3 1/2 weeks (n = 50). Follow-up parameters were clinical symptoms, ankle-brachial index, color Doppler flow duplex sonography, and DSA. RESULTS: Three thrombotic occlusions and three stenoses were observed in the low-dose group. Raising the dose resulted in neither thrombotic nor other events within the first three months. Seven stenoses occurred afterwards up to the 7th month. The complication rate was low: one moderate hematoma and one puncture aneurysm. Primary patency rate was 88% and 80% for one and two years, respectively. This is significantly better than the primary patency rates for patients receiving low-dose lmwh (p < 0.005) or unfractionated heparin (p < 0.05). CONCLUSIONS: Hence, high-dose administration of the lmwh reviparin lowers the restenosis rate after stent implantation in femoropopliteal arteries.


Assuntos
Angiografia Digital , Anticoagulantes/administração & dosagem , Arteriopatias Oclusivas/terapia , Heparina de Baixo Peso Molecular/administração & dosagem , Stents , Idoso , Anticoagulantes/efeitos adversos , Arteriopatias Oclusivas/diagnóstico por imagem , Relação Dose-Resposta a Droga , Esquema de Medicação , Feminino , Artéria Femoral/diagnóstico por imagem , Heparina de Baixo Peso Molecular/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Poplítea/diagnóstico por imagem , Estudos Prospectivos , Recidiva
16.
Cardiovasc Intervent Radiol ; 21(5): 375-9, 1998.
Artigo em Inglês | MEDLINE | ID: mdl-9853142

RESUMO

PURPOSE: To examine the efficacy of the low-molecular-weight heparin, reviparin, for prevention of femoropopliteal stent restenosis. METHODS: Forty-two patients who had implantation of flexible tantalum stents for the treatment of stenosis (n = 24) or occlusion (n = 18) of the femoral (n = 27) or popliteal (n = 15) arteries were included in this study protocol. An intraarterial bolus of 5000 IU heparin was given before percutaneous transluminal angioplasty (PTA), and in the case of stent implantation due to unsuccessful PTA, an additional dose of reviparin (3500 anti-factor Xa IU) was given. Postprocedurally, 10,500 anti-factor Xa IU of reviparin were administered intravenously over 24 hr, followed by 3500 anti-factor Xa IU subcutaneously twice a day for 23 days. Oral aspirin (100 mg/day) was prescribed for the long term. Follow-up criteria (maximum follow-up 37 months) were clinical symptoms, Doppler ankle arm indices, color and duplex sonography, and angiography for suspicion of restenosis. RESULTS: Early stent thromboses were not observed. Overall primary patency rate (PPR) was 88% +/- 6.0% (1 year) and 74% +/- 10.1% (2 years). Major hemorrhagic complications have not occurred. CONCLUSION: Reviparin administered in a high dose over a period of 24 days is a safe medication regimen and provides excellent patency rates after stent implantation.


Assuntos
Anticoagulantes/administração & dosagem , Arteriopatias Oclusivas/tratamento farmacológico , Arteriopatias Oclusivas/cirurgia , Veia Femoral/cirurgia , Heparina de Baixo Peso Molecular/administração & dosagem , Veia Poplítea/cirurgia , Pré-Medicação , Stents/efeitos adversos , Grau de Desobstrução Vascular/efeitos dos fármacos , Adulto , Idoso , Idoso de 80 Anos ou mais , Angioplastia com Balão/efeitos adversos , Constrição Patológica/etiologia , Constrição Patológica/prevenção & controle , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Cuidados Pré-Operatórios , Estudos Prospectivos , Prevenção Secundária , Resultado do Tratamento
17.
Cardiovasc Intervent Radiol ; 21(6): 487-96, 1998.
Artigo em Inglês | MEDLINE | ID: mdl-9853167

RESUMO

PURPOSE: Polymer-coated, dexamethasone (DXM)-releasing stents were tested in order to assess the efficacy of DXM released locally for the prevention of stent restenosis due to intimal hyperplasia. METHODS: Strecker stents coated with a biodegradable membrane containing DXM were implanted percutaneously into the femoral artery in 14 dogs. The contralateral artery received a conventional non-coated stent serving as control. The drugs are eluted by degradation of the carrier membrane. Follow-up intraarterial digital subtraction angiography (DSA) was obtained at 3, 6, 9, 12, and 24 weeks with subsequent autopsy. Specimens for gross and microscopic pathology were obtained and histomorphometry was performed. RESULTS: Four of 14 DXM-coated stents showed thrombotic occlusion within the first 3 weeks; ten DXM-coated stents remained patent. At follow-up DSA, DXM-coated stents showed a significantly wider lumen than the non-coated stents. At morphometry there was less intimal hyperplasia over DXM-coated stents than over non-coated stents (p < 0.05). CONCLUSION: DXM-coated stents reduce neointimal hyperplasia in dogs when compared with non-coated stents.


Assuntos
Angioplastia com Balão/instrumentação , Anti-Inflamatórios/administração & dosagem , Arteriopatias Oclusivas/prevenção & controle , Dexametasona/administração & dosagem , Artéria Femoral , Hiperplasia/prevenção & controle , Stents , Túnica Íntima/efeitos dos fármacos , Angiografia , Angioplastia com Balão/métodos , Animais , Arteriopatias Oclusivas/etiologia , Materiais Revestidos Biocompatíveis , Constrição Patológica/tratamento farmacológico , Constrição Patológica/prevenção & controle , Modelos Animais de Doenças , Cães , Portadores de Fármacos , Hiperplasia/etiologia , Hiperplasia/patologia , Doenças Vasculares Periféricas/terapia , Valores de Referência , Prevenção Secundária , Stents/efeitos adversos , Túnica Íntima/diagnóstico por imagem , Túnica Íntima/patologia
18.
Aktuelle Radiol ; 8(4): 191-5, 1998 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-9759466

RESUMO

PURPOSE: The relations between image quality in last image hold images and dose in grid controlled fluoroscopy in comparison to the continuous mode need to be characterised and recommendations for the clinical application of this technique should be given. MATERIAL AND METHODS: Spatial resolution, signal-noise ratio and, contrast-detail visibility were evaluated by phantom measurements in grid controlled pulsed and continuous fluoroscopy. Dose was measured at the image intensifier entrance. Image quality of last image hold (LIH) images of clinical examinations was graded in relation to single shot exposures. RESULTS: Signal-noise ratio and contrast-detail visibility depend on the dose per puls. Spatial resolution and contrast-detail visibility in grid controlled fluoroscopy are superior than to in the continuous mode. Image quality of the LIH images from the grid controlled fluoroscopy was improved. Radiation exposure could be reduced to 10-46%. CONCLUSIONS: Combinations of puls-dose and -frequency are recommended for achieving extensive dose reduction and improved image quality of LIH images.


Assuntos
Diagnóstico por Imagem/normas , Radiometria , Cintilografia/normas , Fluorometria , Fluoroscopia , Imagem do Acúmulo Cardíaco de Comporta , Humanos , Garantia da Qualidade dos Cuidados de Saúde , Efeitos da Radiação , Intensificação de Imagem Radiográfica
19.
Cardiovasc Intervent Radiol ; 21(2): 109-15, 1998.
Artigo em Inglês | MEDLINE | ID: mdl-9502676

RESUMO

PURPOSE: To present the initial results of a new percutaneously implantable catheter port system (PIPS) used for long-term intraarterial infusion therapy in patients with severe ischemic limb disease. METHODS: Ten patients with deep, extended ischemic ulcerations (all 10) and osteomyelitis (6/10) of the foot received intraarterial infusions of prostaglandine E1 and antibiotics, if indicated, via a new port catheter system with the port placed subcutaneously above the groin after percutaneous introduction and the catheter tip placed into the superficial or deep femoral artery. RESULTS: Port implantation and repeated port access were uncomplicated. During the follow-up period (mean 11 months, range 1 week-50 months), port migration, leakage, or infection was not observed. Three catheters thrombosed and were opened by fibrinolysis with recombinant tissue plasminogen activator instilled via the port. Treatment success was achieved in 8 patients: relief from rest pain (8 patients), reduction of ulcer size (4/8), and complete healing (4/8). Limb savage rate was 80%. In 2 patients amputation could not be avoided. CONCLUSION: Selective long-term arterial infusion therapy presents a valuable therapeutic regimen for limb salvage. With the new catheter port system, repeated local intraarterial infusion is safe and simple.


Assuntos
Cateteres de Demora , Infusões Intra-Arteriais/métodos , Isquemia/tratamento farmacológico , Perna (Membro)/irrigação sanguínea , Adulto , Idoso , Idoso de 80 Anos ou mais , Alprostadil/administração & dosagem , Cateteres de Demora/efeitos adversos , Feminino , Artéria Femoral , Pé/irrigação sanguínea , Humanos , Infusões Intra-Arteriais/efeitos adversos , Infusões Intra-Arteriais/instrumentação , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Vasodilatadores/administração & dosagem
20.
Radiology ; 205(2): 375-83, 1997 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-9356617

RESUMO

PURPOSE: To evaluate the long-term success of femoropopliteal artery stent placement after technical failure of balloon angioplasty and to determine potential factors predictive of stent failure. MATERIALS AND METHODS: In 80 patients, flexible tantalum stents were implanted for treatment of residual stenosis greater than 30% after balloon angioplasty of femoropopliteal artery stenoses (n = 33) or occlusions (n = 47). Follow-up examinations were performed at 1-72 months to evaluate early and late stent failure according to risk factors such as lesion type, anatomic location, stent length, runoff quality, and restenosis after balloon angioplasty. RESULTS: Early stent thrombosis occurred within 10 days after stent placement in four (5%) patients; the frequency was higher (P < .01) in stents longer than 4 cm (14%) versus that in stents 4 cm or shorter (2%). For all stents, the 2-year primary patency rate was 51% and the 3-year rate was 48%. The 2-year primary patency rate was significantly better (P < .05) for shorter stents (59%) versus that for longer stents (30%) and for treated stenoses (73%) versus treated occlusions (33%). Multivariate analysis revealed that lesion type and lesion length were the most reliable factors predictive of stent failure. CONCLUSION: Successful stent therapy does not seem to depend on the type of stent used but rather on lesion type, lesion length, and other predisposing factors.


Assuntos
Arteriopatias Oclusivas/cirurgia , Artéria Femoral/cirurgia , Artéria Poplítea/cirurgia , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Angioplastia com Balão , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/terapia , Falha de Equipamento , Feminino , Artéria Femoral/diagnóstico por imagem , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Artéria Poplítea/diagnóstico por imagem , Estudos Prospectivos , Radiografia , Fatores de Risco , Stents/efeitos adversos , Tantálio , Trombose/etiologia , Falha de Tratamento , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...