Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Biomech Eng ; 136(3): 035001, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24763632

RESUMO

Various techniques exist for quantifying articular contact stress distributions, an important class of measurements in the field of orthopaedic biomechanics. In situations where the need for dynamic recording has been paramount, the approach of preference has involved thin-sheet multiplexed grid-array transducers. To date, these sensors have been used to study contact stresses in the knee, shoulder, ankle, wrist, and spinal facet joints. Until now, however, no such sensor had been available for the human hip joint due to difficulties posed by the deep, bi-curvilinear geometry of the acetabulum. We report here the design and development of a novel sensor capable of measuring dynamic contact stress in human cadaveric hip joints (maximum contact stress of 20 MPa and maximum sampling rate 100 readings/s). Particular emphasis is placed on issues concerning calibration, and on the effect of joint curvature on the sensor's performance. The active pressure-sensing regions of the sensors have the shape of a segment of an annulus with a 150-deg circumferential span, and employ a polar/circumferential "ring-and-spoke" sensel grid layout. There are two sensor sizes, having outside radii of 44 and 48 mm, respectively. The new design was evaluated in human cadaver hip joints using two methods. The stress magnitudes and spatial distribution measured by the sensor were compared to contact stresses measured by pressure sensitive film during static loading conditions that simulated heel strike during walking and stair climbing. Additionally, the forces obtained by spatial integration of the sensor contact stresses were compared to the forces measured by load cells during the static simulations and for loading applied by a dynamic hip simulator. Stress magnitudes and spatial distribution patterns obtained from the sensor versus from pressure sensitive film exhibited good agreement. The joint forces obtained during both static and dynamic loading were within ±10% and ±26%, respectively, of the forces measured by the load cells. These results provide confidence in the measurements obtained by the sensor. The new sensor's real-time output and dynamic measurement capabilities hold significant advantages over static measurements from pressure sensitive film.


Assuntos
Acetábulo/fisiologia , Fêmur/fisiologia , Articulação do Quadril/fisiologia , Manometria/instrumentação , Transdutores , Adulto , Cadáver , Desenho de Equipamento , Análise de Falha de Equipamento , Fricção , Humanos , Masculino , Amplitude de Movimento Articular/fisiologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estresse Mecânico , Propriedades de Superfície
2.
Proc Inst Mech Eng H ; 225(10): 993-1002, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22204121

RESUMO

The objective of this work was to develop a method for repeated same-site measurement of mechanical properties suitable for the detection of degenerative changes in a biologically active explant model after a single blunt impact injury. Focal blunt impact injuries to articular surfaces lead to local cartilage degeneration and loss of mechanical properties. We employed a repeated measurement methodology to determine variations in mechanical same-site properties before and after injury in living cartilage, with the hypothesis that normalization with initial mechanical properties may provide a clearer evaluation of impact effects and improve our understanding of the biologic responses to impact injury. Bovine osteochondral explants were cultured for up to 14 days after impact injury. Indentation tests were performed before and after impact injury to assess relative changes in mechanical properties. Creep strain increased significantly in impacted explants after 7 days and in both impacted and control explants after 14 days. Further analysis at 14 days revealed decreases in stretch factor beta, creep time constant and local compressive modulus. A repeated measures methodology reliably detected changes in the mechanical behaviour of viable osteochondral explants after a single impact injury.


Assuntos
Cartilagem Articular/lesões , Cartilagem Articular/metabolismo , Ferimentos não Penetrantes/complicações , Animais , Bovinos , Técnicas de Cultura/métodos , Degeneração do Disco Intervertebral/fisiopatologia , Osteoartrite , Osteocondrite
3.
Osteoarthritis Cartilage ; 18(11): 1509-17, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20813194

RESUMO

OBJECTIVE: To determine the activation of Mitogen activated protein (MAP) kinases in and around cartilage subjected to mechanical damage and to determine the effects of their inhibitors on impaction-induced chondrocyte death and cartilage degeneration. DESIGN: The phosphorylation of MAP kinases was examined with confocal microscopy and immunoblotting. The effects of MAP kinase inhibitors on impaction-induced chondrocyte death and proteoglycan (PG) loss were determined with fluorescent microscopy and 1, 9-Dimethyl-Methylene Blue (DMMB) assay. The expression of catabolic genes at mRNA levels was examined with quantitative real-time PCR. RESULTS: Early p38 activation was detected at 20 min and 1h post-impaction. At 24h, enhanced phosphorylation of p38 and extracellular signal-regulated protein kinase (ERK)1/2 was visualized in chondrocytes from in and around impact sites. The phosphorylation of p38 was increased by 3.0-fold in impact sites and 3.3-fold in adjacent cartilage. The phosphorylation of ERK-1 was increased by 5.8-fold in impact zone and 5.4-fold in adjacent cartilage; the phosphorylation of ERK-2 increased by 4.0-fold in impacted zone and 3.6-fold in adjacent cartilage. Furthermore, the blocking of p38 pathway did not inhibit impaction-induced ERK activation. The inhibition of p38 or ERK pathway significantly reduced injury-related chondrocyte death and PG losses. Quantitative Real-time PCR analysis revealed that blunt impaction significantly up-regulated matrix metalloproteinase (MMP)-13, Tumor necrosis factor (TNF)-α, and ADAMTS-5 expression. CONCLUSION: These findings implicate p38 and ERK mitogen activated protein kinases (MAPKs) in the post-injury spread of cartilage degeneration and suggest that the risk of post-traumatic osteoarthritis (PTOA) following joint trauma could be decreased by blocking their activities, which might be involved in up-regulating expressions of MMP-13, ADAMTS-5, and TNF-α.


Assuntos
Cartilagem Articular/lesões , Cartilagem Articular/metabolismo , Proteínas Quinases Ativadas por Mitógeno/metabolismo , Animais , Cartilagem Articular/enzimologia , Bovinos , Morte Celular/efeitos dos fármacos , Morte Celular/fisiologia , Sobrevivência Celular/fisiologia , Condrócitos/enzimologia , Condrócitos/fisiologia , Modelos Animais de Doenças , MAP Quinases Reguladas por Sinal Extracelular/metabolismo , Immunoblotting , Reação em Cadeia da Polimerase , Proteoglicanas/análise , Estresse Mecânico , Proteínas Quinases p38 Ativadas por Mitógeno/metabolismo
4.
J Neurol Neurosurg Psychiatry ; 80(9): 1019-22, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19602474

RESUMO

BACKGROUND: The importance of physical activity as a modifiable risk factor for stroke in particular and cardiovascular disease in general is well documented. The effect of exercise on stroke severity and stroke outcomes is less clear. This study aimed to assess that effect. METHODS: Data collected for patients enrolled in the Ischemic Stroke Genetics Study were reviewed for prestroke self-reported levels of activity and four measures of stroke outcome assessed at enrollment and approximately 3 months after enrollment. Logistic regression was used to assess the association between physical activity and stroke outcomes, unadjusted and adjusted for patient characteristics. RESULTS: A total of 673 patients were enrolled; 50.5% reported aerobic physical activity less than once a week, 28.5% reported aerobic physical activity one to three times weekly, and 21% reported aerobic physical activity four times a week or more. Patients with moderate and high levels of physical activity were more likely to have higher Barthel Index (BI) scores at enrollment. A similar association was detected for exercise and good outcomes for the Oxford Handicap Scale (OHS). After 3 months of follow-up, moderate activity was still associated with a high BI score. No significant association was detected for activity and the OHS or Glasgow Outcome Scale at follow-up after adjustment for patient characteristics. CONCLUSIONS: Higher levels of self-reported prestroke physical activity may be associated with functional advantages after stroke. Our findings should be seen as exploratory, requiring confirmation, ideally in a longitudinal study of exercise in an older population.


Assuntos
Atividade Motora/fisiologia , Acidente Vascular Cerebral/fisiopatologia , Idoso , Isquemia Encefálica/complicações , Infarto Cerebral/epidemiologia , Infarto Cerebral/patologia , Estudos de Coortes , Avaliação da Deficiência , Exercício Físico/fisiologia , Feminino , Escala de Resultado de Glasgow , Humanos , Atividades de Lazer , Modelos Logísticos , Masculino , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
6.
J Biomed Eng ; 2(1): 15-24, 1980 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-7359894

RESUMO

The repetitive nature of cardiac waveforms renders them suitable for processing by signal averaging. A flexible system is described, based on a general-purpose digital computer, capable of averaging a variety of cardiac signals in excess of 0.5 microV containing frequency components below a theoretical Nyquist limit of 5 kHz. Important features of the system include real-time processing capability at a high level of interactive control, and the facility to trigger the averaging process accurately from any part of either the data or a synchronous reference waveform. Application of the system to electrocardiographic and phonocardiographic signals at conventional gain has enabled clinically useful records to be obtained in the face of obtrusive environmental noise. The averaging of signals of a similar nature after considerably increased amplification has revealed cardiac activity unseen in conventional records in a total of 81 subjects.


Assuntos
Computadores , Eletrocardiografia , Coração/fisiologia , Conversão Análogo-Digital , Apresentação de Dados , Ruídos Cardíacos , Humanos , Oscilometria , Reconhecimento Automatizado de Padrão , Pressão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...