Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Eur Radiol ; 27(6): 2298-2308, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27682312

RESUMO

PURPOSE: To investigate diagnostic accuracy of 3rd-generation dual-source CT (DSCT) coronary angiography in obese and non-obese patients. METHODS: We retrospectively analyzed 76 patients who underwent coronary CT angiography (CCTA) and invasive coronary angiography. Prospectively ECG-triggered acquisition was performed with automated tube voltage selection (ATVS). Patients were dichotomized based on body mass index in groups A (<30 kg/m2, n = 37) and B (≥30 kg/m2, n = 39) and based on tube voltage in groups C (<120 kV, n = 46) and D (120 kV, n = 30). Coronary arteries were assessed for significant stenoses (≥50 % luminal narrowing) and diagnostic accuracy was calculated. RESULTS: Per-patient overall sensitivity, specificity, positive predictive value, negative predictive value (NPV) and accuracy were 96.9 %, 95.5 %, 93.9 %, 97.7 % and 96.1 %, respectively. Sensitivity and NPV were lower in groups B and D compared to groups A and C, but no statistically significant differences were observed (group A vs. B: sensitivity, 100.0 % vs. 93.3 %, p = 0.9493; NPV, 100 % vs. 95.5 %, p = 0.9812; group C vs. D: sensitivity, 100.0 % vs. 92.3 %, p = 0.8462; NPV, 100.0 % vs. 94.1 %, p = 0.8285). CONCLUSION: CCTA using 3rd-generation DSCT and (ATVS) provides high diagnostic accuracy in both non-obese and obese patients. KEY POINTS: • Coronary CTA provides high diagnostic accuracy in non-obese and obese patients. • Diagnostic accuracy between obese and non-obese patients showed no significant difference. • <120 kV studies were performed in 44 % of obese patients. • Current radiation dose-saving approaches can be applied independent of body habitus.


Assuntos
Angiografia por Tomografia Computadorizada/normas , Angiografia Coronária/normas , Obesidade/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Índice de Massa Corporal , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Feminino , Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
2.
J Cardiovasc Comput Tomogr ; 10(5): 377-83, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27431607

RESUMO

OBJECTIVE: To evaluate quantitative markers derived from coronary CT angiography (coronary CTA) performed prior to percutaneous coronary intervention (PCI) with stent placement for predicting in-stent restenosis (ISR) as defined by quantitative coronary angiography (QCA). MATERIALS AND METHODS: We retrospectively analyzed the data of 74 patients (60 ± 12 years, 72% male) who had undergone dual-source coronary CTA within 3 months prior to a PCI procedure that included stent placement. Quantitative markers of the target vessel were derived from coronary CTA: Total plaque volume (TPV), calcified and non-calcified plaque volumes (CPV and NCPV), plaque burden (PB in %), remodeling index (RI), and lesion length (LL). Marker performance for predicting ISR, as defined by QCA at follow-up, was assessed. RESULTS: Twenty-one of 74 stented lesions showed ISR on follow-up (mean 616 ± 447 days). When comparing stent length and LL in patients with ISR, a trend towards less complete stent coverage of the target lesion was observed in cases with ISR (17/21 vs. 4/53 cases, p = 0.07). In multivariate analysis (corrected for dyslipidemia), the following markers showed predictive value for ISR (odds ratio [OR]): NCPV (OR 1.08, p = 0.045), LL (OR 1.38, p = 0.0024), and RI (OR 1.13, p = 0.0019). Sensitivity and specificity for ISR were: NCPV 65% and 80%, LL 74% and 74%, and RI 71% and 78%. At receiver-operating characteristics analysis, NCPV (0.72, p = 0.001), LL (0.77, p < 0.0001), and RI (0.79, p < 0.0001) showed discriminatory power for predicting ISR. A combination of these markers showed incremental predictive value (AUC 0.89, p < 0.0001) with sensitivity and specificity of 90% and 84%, respectively. CONCLUSION: Coronary CTA-derived NCPV, LL, and RI portend predictive value for ISR with incremental predictive value when combining these parameters.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Doença da Artéria Coronariana/terapia , Reestenose Coronária/etiologia , Vasos Coronários/diagnóstico por imagem , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Stents , Calcificação Vascular/terapia , Idoso , Área Sob a Curva , Doença da Artéria Coronariana/diagnóstico por imagem , Reestenose Coronária/diagnóstico por imagem , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Placa Aterosclerótica , Valor Preditivo dos Testes , Curva ROC , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento , Calcificação Vascular/diagnóstico por imagem
3.
Eur Radiol ; 26(12): 4380-4389, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26960541

RESUMO

PURPOSE: To evaluate the impact of noise-optimized virtual monochromatic imaging (VMI+) on stent visualization and accuracy for in-stent re-stenosis at lower extremity dual-energy CT angiography (DE-CTA). MATERIAL AND METHODS: We evaluated third-generation dual-source DE-CTA studies in 31 patients with prior stent placement. Images were reconstructed with linear blending (F_0.5) and VMI+ at 40-150 keV. In-stent luminal diameter was measured and contrast-to-noise ratio (CNR) calculated. Diagnostic confidence was determined using a five-point scale. In 21 patients with invasive catheter angiography, accuracy for significant re-stenosis (≥50 %) was assessed at F_0.5 and 80 keV-VMI+ chosen as the optimal energy level based on image-quality analysis. RESULTS: At CTA, 45 stents were present. DSA was available for 28 stents whereas 12 stents showed significant re-stenosis. CNR was significantly higher with ≤80 keV-VMI+ (17.9 ± 6.4-33.7 ± 12.3) compared to F_0.5 (16.9 ± 4.8; all p < 0.0463); luminal stent diameters were increased at ≥70 keV (5.41 ± 1.8-5.92 ± 1.7 vs. 5.27 ± 1.8, all p < 0.001) and diagnostic confidence was highest at 70-80 keV-VMI+ (4.90 ± 0.48-4.88 ± 0.63 vs. 4.60 ± 0.66, p = 0.001, 0.0042). Sensitivity, negative predictive value and accuracy for re-stenosis were higher with 80 keV-VMI+ (100, 100, 96.4 %) than F_0.5 (90.9, 94.1, 89.3 %). CONCLUSION: 80 keV-VMI+ improves image quality, diagnostic confidence and accuracy for stent evaluation at lower extremity DE-CTA. KEY POINTS: • The impact of noise-optimized virtual monochromatic imaging on stent visualization was assessed. • Virtual monochromatic imaging significantly improves stent lumen visualization and diagnostic confidence. • At 80 keV diagnostic performance for detection of in-stent restenosis was increased. • 80 keV virtual monochromatic images are recommended for stent evaluation of lower extremity vasculature.


Assuntos
Algoritmos , Angiografia por Tomografia Computadorizada/métodos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Stents , Adulto , Idoso , Feminino , Humanos , Isquemia/diagnóstico por imagem , Isquemia/terapia , Extremidade Inferior/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído
4.
Eur J Radiol ; 85(2): 498-506, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26781157

RESUMO

PURPOSE: To compare diagnostic accuracy between dual-energy CT lung perfused blood volume (Lung PBV) imaging and single photon emission computed tomography (SPECT) in detecting chronic thromboembolic pulmonary hypertension (CTEPH) with histopathological results as reference standard in a canine model. MATERIALS AND METHODS: Eighteen CTEPH canines were included into this experimental study. All procedures including paracentesis, embolization, scanning, pressure measurement and feeding medicine were repeated each two weeks, until systolic/diastolic pressure in canines was ≥ 30/15 mm Hg or mean pulmonary artery pressure ≥ 20 mm Hg, and then sacrificed for histopathology examination. Two radiologists (readers 1 and 2) and two nuclear radiologists (readers 3 and 4) analyzed images of conventional CT pulmonary angiography in dual-energy CT mode, Lung PBV imaging and SPECT, respectively. The presence, numbers, and locations of pulmonary emboli (PE) were recorded on a per-lobe basis. Pathological examination was served as reference standard. Sensitivity, specificity and accuracy of Lung PBV and SPECT were calculated. Kappa statistics were used to quantify inter-reader agreement. RESULTS: With histopathological results as reference standard, the sensitivities of 72.2%, 78.8%, 81.2%, specificities of 75.9%, 87.5%, 84.8%, accuracies of 73.8%, 83.1%, 83.1%, for readers 1, 2 and both with Lung PBV, respectively. Readers 3, 4 and both had sensitivities of 14.3%, 25.7%, 33.3%, specificities of 90.0%, 86.7%, 93.3%, accuracies of 49.2%, 53.8%, 60.0% with SPECT for detecting CTEPH. Inter-reader agreements were good for dual-energy CT (kappa=0.662) and SPECT (k=0.706) for detecting CTEPH. CONCLUSION: Dual-energy CT had a higher accuracy to detect CTEPH than SPECT in this canine model study.


Assuntos
Hipertensão Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Animais , Volume Sanguíneo , Doença Crônica , Modelos Animais de Doenças , Cães , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sístole
5.
Eur Radiol ; 26(9): 2937-46, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26712517

RESUMO

OBJECTIVES: To evaluate the image quality of coronary CT angiography (CCTA) in obese patients using a 3(rd) generation, dual-source CT scanner. METHODS: We retrospectively evaluated 102 overweight and obese patients who had undergone CCTA. Studies were performed with 3(rd) generation dual-source CT, prospectively ECG-triggered acquisition at 120 kV, and automated tube current modulation. Advanced modeled iterative reconstruction was used. Patients were divided into three BMI groups: 1)25-29.9 kg/m(2); 2)30-39.9 kg/m(2); 3) ≥ 40 kg/m(2). Vascular attenuation in the coronary arteries was measured. Contrast-to-noise ratio (CNR) was calculated. Image quality was subjectively evaluated using five-point scales. RESULTS: Image quality was considered diagnostic in 97.6 % of examinations. CNR was consistently adequate in all groups but decreased for groups 2 and 3 in comparison to group 1 as well as for group 3 compared to group 2 (p = 0.001, respectively). Subjective image quality was significantly higher in group 1 compared to group 3 (attenuation proximal: 4.8 ± 0.4 vs. 4.4 ± 0.6, p = 0.011; attenuation distal: 4.5 ± 0.7 vs. 4.0 ± 0.8, p = 0.019; noise: 4.7 ± 0.6 vs. 3.8 ± 0.7, p < 0.001). The mean effective dose was 9.5 ± 3.9 mSv for group 1, 11.4 ± 4.7 mSv for group 2 and 14.0 ± 6.4 mSv for group 3. CONCLUSION: Diagnostic image quality can be routinely obtained at CCTA in obese patients with 3(rd) generation DSCT at 120 kV. KEY POINTS: • Diagnostic CCTA can be routinely performed in obese patients with 3 (rd) generation DSCT. • 120-kV tube voltage allows diagnostic image quality in patients with BMI > 40 kg/m (2) . • 80-ml contrast medium can be administered without significant decline in vascular attenuation.


Assuntos
Índice de Massa Corporal , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Obesidade , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...