1.
Paediatr Anaesth ; 26(12): 1206-1208, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27663573

RESUMO

In small children, high-flow nasal cannula therapy may prolong apnea time even when an inspiratory oxygen fraction below 100% is used. This will be beneficial in prolonged intubation attempts, but especially during procedures requiring prolonged apnea time, leading to fewer airway manipulations and markedly enhanced surgical conditions.


Assuntos
Apneia/terapia , Laringe/cirurgia , Oxigenoterapia/instrumentação , Oxigenoterapia/métodos , Cânula , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Masculino , Tempo
2.
Eur J Anaesthesiol ; 32(9): 631-9, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26061874

RESUMO

BACKGROUND: Paediatric supraglottic airway devices AmbuAura-i and Air-Q were designed as conduits for tracheal intubation. Although fibreoptic-guided intubation has proved successful, blind intubation as a rescue technique has never been evaluated. OBJECTIVE: Evaluation of blind intubation through AmbuAura-i and Air-Q. On the basis of fibreoptic view data, we hypothesised that the success rate with the AmbuAura-i would be higher than with the Air-Q. DESIGN: A randomised controlled trial. SETTING: University Childrens' Hospital; September 2012 to July 2014. PATIENTS: Eighty children, American Society of Anesthesiologists (ASA) class I to III, weight 5 to 50 kg. INTERVENTIONS: Tracheal intubation was performed through the randomised device with the tip of a fibrescope placed inside and proximal to the tip of the tracheal tube. This permitted sight of tube advancement, but without fibreoptic guidance (visualised blind intubation). MAIN OUTCOME MEASURES: Primary outcome was successfully visualised blind intubation; secondary outcomes included supraglottic airway device success, insertion times, airway leak pressure, fibreoptic view and adverse events. RESULTS: Personal data did not differ between groups. In contrast to our hypothesis, blind intubation was possible in 15% with the Air-Q and in 3% with the AmbuAura-i [95% confidence interval (95% CI) 6 to 31 vs. 0 to 13%; P = 0.057]. First attempt supraglottic airway device insertion success rates were 95% (Air-Q) and 100% (AmbuAura-i; 95% CI 83 to 99 vs. 91 to 100; P = 0.49). Median leak pressures were 18 cmH2O (Air-Q) and 17 cmH2O [AmbuAura-i; interquartile range (IQR) 14 to 18 vs. 14 to 19 cmH2O; P = 0.66]. Air-Q insertion was slower (27 vs. 19 s, P < 0.001). There was no difference in fibreoptic view, or adverse events (P > 0.05). In one child (Air-Q size 1.5, tube size 3.5), the tube dislocated during device removal. CONCLUSION: Ventilation with both devices is reliable, but success of blind intubation is unacceptably low and cannot be recommended for elective or rescue purposes. If intubation through a paediatric supraglottic airway device is desired, we suggest that fibreoptic guidance is used. TRIAL REGISTRATION: Clinicaltrials.gov identifier: NCT01692522.


Assuntos
Anestesia Geral/métodos , Epiglote , Tecnologia de Fibra Óptica/métodos , Intubação Intratraqueal/métodos , Anestesia Geral/instrumentação , Criança , Pré-Escolar , Desenho de Equipamento/instrumentação , Desenho de Equipamento/métodos , Feminino , Tecnologia de Fibra Óptica/instrumentação , Humanos , Lactente , Intubação Intratraqueal/instrumentação , Masculino , Método Simples-Cego
3.
Anesthesiology ; 115(1): 102-10, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21572318

RESUMO

BACKGROUND: This prospective, randomized, controlled trial compares the performance of the pediatric i-gel (Intersurgical Ltd., Wokingham, United Kingdom) with the Ambu AuraOnce laryngeal mask (Ambu A/S, Ballerup, Denmark) in anesthetized and ventilated children. METHODS: With ethics committee approval and written informed consent, the authors included 208 children, aged 0-17 yr, scheduled for elective day-surgery under general anesthesia. The primary outcome variable was oropharyngeal leak pressure. Other outcome variables were first-attempt and overall success, time to sufficient ventilation, and adverse events. RESULTS: Demographic data did not differ between groups. The leak pressure of the i-gel was significantly higher than the leak pressure of the Ambu (mean ± SD: 22 ± 5 cm H2O vs. 19 ± 3, P < 0.01). First-attempt success was 91% for the i-gel and 93% for the Ambu (P = 0.50). Overall success was 93% for the i-gel versus 98% for the Ambu (P = 0.10). Successfully inserted i-gels needed to be secured by taping in place to ensure the seal in 44% (0% with the Ambu, P < 0.01). Insertion was faster with the Ambu (24 ± 8 s vs. 27 ± 11, P = 0.02). There were no major side effects with either device. CONCLUSIONS: The leak pressure of the i-gel was statistically but not clinically significantly higher than the leak pressure of the Ambu. Time to insertion was longer with the i-gel. Both airway devices are suitable for positive pressure ventilation with high success rates in infants and children. Because the i-gel is prone to sliding out, it must be taped in place to avoid loss of the airway.


Assuntos
Manuseio das Vias Aéreas/instrumentação , Anestesia Geral , Máscaras Laríngeas , Respiração Artificial , Adolescente , Manuseio das Vias Aéreas/efeitos adversos , Anestesia Geral/efeitos adversos , Criança , Pré-Escolar , Equipamentos Descartáveis , Desenho de Equipamento , Feminino , Humanos , Lactente , Recém-Nascido , Máscaras Laríngeas/efeitos adversos , Masculino , Complicações Pós-Operatórias/epidemiologia , Respiração Artificial/efeitos adversos , Resultado do Tratamento