Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Contam Hydrol ; 265: 104382, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38861839

RESUMO

Some Per- and polyfluoroalkyl substances (PFAS) are strongly retained in the vadose zone due to their sorption to both soils and air-water interfaces. While significant research has been dedicated to understanding equilibrium behavior for these multi-phase retention processes, leaching and desorption from aqueous film-forming foam (AFFF) impacted soils under field relevant conditions can exhibit significant deviations from equilibrium. Herein, laboratory column studies using field collected AFFF-impacted soils were employed to examine the leaching of perfluoroalkyl acids (PFAAs) under simulated rainfall conditions. The HYDRUS 1-D model was calibrated to estimate the unsaturated hydraulic properties of the soil in a layered system using multiple boundary condtions. Forward simulations of equilibrium PFAS partitioning using the HYDRUS model and simplified mass balance calculations showed good agreement with the net PFAS mass flux out of the column. However, neither were able to predict the PFAS concentrations in the leached porewater. To better understand the mechanisms controlling the leaching behavior, the HYDRUS 1-D two-site leaching model incorporating solid phase rate limitation and equilibrium air-water interfacial partitioning was employed. Three variations of the novel model incorporating different forms of equilibrium air-water interfacial partitioning were considered using built-in numerical inversion. Results of numerical inversion show that a combination of air-water interfacial collapse and rate-limited desorption from soils can better predict the unique leaching behavior exhibited by PFAAs in AFFF-impacted soils. A sensitivity analysis of the initial conditions and rate-limited desorption terms was conducted to assess the agreement of the model with measured data. The models demonstrated herein show that, under some circumstances, laboratory equilibrium partitioning data can provide a reasonable estimation of total mass leaching, but fail to account for the significant rate-limited, non-Fickian transport which affect PFAA leaching to groundwater in unsaturated soils.

2.
J Hazard Mater ; 465: 133460, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38211524

RESUMO

The widespread use of per- and polyfluoroalkyl substances (PFAS)-containing products in numerous commercial and industrial applications has resulted in their occurrence in wastewater treatment plants (WWTPs). Herein, proof-of-concept bench-scale experiments were performed to measure the extent to which PFAS could be removed from a WWTP if aerosols generated during aeration were captured. Experiments were designed to mimic the aeration rate:water volume ratio, the water volume:surface area ratio, and aeration bubble size applicable to the full-scale aeration vessel. Results showed that substantial (75%) removal of perfluorooctane sulfonate (PFOS) was observed under these operating conditions in the bench-scale system; up to 97% PFOS removal was observed if the aeration rate was increased 3-fold. PFAS removal generally increased with increasing aerosol capture and with increasing PFAS surface activity. Analysis of semi-quantified PFAS showed that the semi-quantified PFAS accounted for approximately 93% of the identified PFAS in the raw wastewater, dominated largely by the presence of 2:2 fluorotelomer carboxylic acid (2:2 FTCA). This preliminary study suggests that aerosol capture in aeration basins has potential for mitigating PFAS in WWTPs. Further testing is needed to assess the feasibility of this approach at the field scale.

3.
MAbs ; 15(1): 2197668, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37057828

RESUMO

The multi-attribute method (MAM), a liquid chromatography-mass spectrometry (LC-MS)-based peptide mapping method, has gained increased interest and applications in the biopharmaceutical industry. MAM can, in one method, provide targeted quantitation of multiple site-specific product quality attributes, as well as new peak detection. In this review, we focus on the scientific and regulatory considerations of using MAM in product quality attribute monitoring and quality control (QC) of therapeutic proteins. We highlight MAM implementation challenges and solutions with several case studies, and provide our perspective on the opportunities to use MS in QC for applications other than standard peptide mapping-based MAM.


Assuntos
Anticorpos Monoclonais , Produtos Biológicos , Anticorpos Monoclonais/química , Espectrometria de Massas/métodos , Cromatografia Líquida/métodos , Controle de Qualidade
4.
Environ Sci Technol ; 57(13): 5231-5242, 2023 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-36947878

RESUMO

A comprehensive, generalized approach to predict the retention of per- and polyfluoroalkyl substances (PFAS) from aqueous film-forming foam (AFFF) by a soil matrix as a function of PFAS molecular and soil physiochemical properties was developed. An AFFF with 34 major PFAS (12 anions and 22 zwitterions) was added to uncontaminated soil in one-dimensional saturated column experiments and PFAS mass retained was measured. PFAS mass retention was described using an exhaustive statistical approach to generate a poly-parameter quantitative structure-property relationship (ppQSPR). The relevant predictive properties were PFAS molar mass, mass fluorine, number of nitrogens in the PFAS molecule, poorly crystalline Fe oxides, organic carbon, and specific (BET-N2) surface area. The retention of anionic PFAS was nearly independent of soil properties and largely a function of molecular hydrophobicity, with the size of the fluorinated side chain as the main predictor. Retention of nitrogen-containing zwitterionic PFAS was related to poorly crystalline metal oxides and organic carbon content. Knowledge of the extent to which a suite of PFAS may respond to variations in soil matrix properties, as developed here, paves the way for the development of reactive transport algorithms with the ability to capture PFAS dynamics in source zones over extended time frames.


Assuntos
Fluorocarbonos , Poluentes Químicos da Água , Fluorocarbonos/análise , Solo , Poluentes Químicos da Água/análise , Minerais , Água , Carbono
5.
Environ Sci Technol ; 57(13): 5203-5215, 2023 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-36962006

RESUMO

Air-water interfacial retention of poly- and perfluoroalkyl substances (PFASs) is increasingly recognized as an important environmental process. Herein, column transport experiments were used to measure air-water interfacial partitioning values for several perfluoroalkyl ethers and for PFASs derived from aqueous film-forming foam, while batch experiments were used to determine equilibrium Kia data for compounds exhibiting evidence of rate-limited partitioning. Experimental results suggest a Freundlich isotherm best describes PFAS air-water partitioning at environmentally relevant concentrations (101-106 ng/L). A multiparameter regression analysis for Kia prediction was performed for the 15 PFASs for which equilibrium Kia values were determined, assessing 246 possible combinations of 8 physicochemical and system properties. Quantitative structure-property relationships (QSPRs) based on three to four parameters provided predictions of high accuracy without model overparameterization. Two QSPRs (R2 values of 0.92 and 0.83) were developed using an assumed average Freundlich n value of 0.65 and validated across a range of relevant concentrations for perfluorooctane sulfonate (PFOS), perfluorooctanoate (PFOA), and hexafluoropropylene oxide-dimer acid (i.e., GenX). A mass action model was further modified to account for the changing ionic strength on PFAS air-water interfacial sorption. The final result was two distinct QSPRs for estimating PFAS air-water interfacial partitioning across a range of aqueous concentrations and ionic strengths.


Assuntos
Ácidos Alcanossulfônicos , Fluorocarbonos , Poluentes Químicos da Água , Água , Fluorocarbonos/análise , Éteres , Poluentes Químicos da Água/análise , Concentração Osmolar
6.
Bioengineering (Basel) ; 9(11)2022 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-36354552

RESUMO

Heterogeneity of therapeutic Monoclonal antibody (mAb) drugs are due to protein variants generated during the manufacturing process. These protein variants can be critical quality attributes (CQAs) depending on their potential impact on drug safety and/or efficacy. To identify CQAs and ensure the drug product qualities, a thorough characterization is required but challenging due to the complex structure of biotherapeutics. Past characterization studies for basic and acidic variants revealed that full characterizations were limited to the basic charge variants, while the quantitative measurements of acidic variants left gaps. Consequently, the characterization and quantitation of acidic variants are more challenging. A case study of a therapeutic mAb1 accounted for two-thirds of the enriched acidic variants in the initial characterization study. This led to additional investigations, closing the quantification gaps of mAb1 acidic variants. This work demonstrates that a well-designed study with the right choices of analytical methods can play a key role in characterization studies. Thus, the updated strategies for more complete antibody charge variant characterization are recommended.

7.
Environ Sci Technol ; 56(12): 7963-7975, 2022 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-35549168

RESUMO

Predicting the transport of perfluoroalkyl acids (PFAAs) in the vadose zone is critically important for PFAA site cleanup and risk mitigation. PFAAs exhibit several unusual and poorly understood transport behaviors, including partitioning to the air-water interface, which is currently the subject of debate. This study develops a novel use of quasi-saturated (residual air saturation) column experiments to estimate chemical partitioning parameters of both linear and branched perfluorooctane sulfonate (PFOS) in unsaturated soils. The ratio of linear-to-branched air-water interfacial partitioning constants for all six experiments was 1.62 ± 0.24, indicating significantly greater partitioning of linear PFOS isomers at the air-water interface. Standard breakthrough curve analysis and numerical inversion of HYDRUS models support the application of a Freundlich isotherm for PFOS air-water interfacial partitioning below a critical reference concentration (CRC). Data from this study and previously reported unsaturated column data on perfluorooctanoate (PFOA) were reevaluated to examine unsaturated systems for transport nonidealities. This reanalysis suggests both transport nonidealities and Freundlich isotherm behavior for PFOA below the CRC using drainage-based column methods, contrary to the assertions of the original authors. Finally, a combined Freundlich-Langmuir isotherm was proposed to describe PFAA air-water interfacial partitioning across the full range of relevant PFAA concentrations.


Assuntos
Ácidos Alcanossulfônicos , Fluorocarbonos , Poluentes Químicos da Água , Ácidos Alcanossulfônicos/análise , Caprilatos/análise , Fluorocarbonos/análise , Isomerismo , Porosidade , Água , Poluentes Químicos da Água/análise
8.
J Contam Hydrol ; 242: 103842, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34118564

RESUMO

The processes impacting solute transport through unsaturated porous media have been receiving renewed attention due to their relevance to the transport of emerging contaminants. A set of well-monitored and highly controlled experiments in sand columns were conducted to determine the effect of partial saturation on conservative solute breakthrough in porous media. The results suggest traditional transport parameter estimation methods inadequately account for the pore-scale processes of mass transfer to the immobile zones and the effects of partial saturation on advective transport, even for conservative tracers. Accurate estimation of these basic transport parameters is critical to evaluate the multi-phase partitioning of nonconservative solutes, as any errors in these parameters would bias the estimates of multi-phase partitioning parameters. Herein, we introduced the Mass Transfer Index (MTI), a semi-empirical approach for quantifying the impact of non-Fickian elements of pore-scale unsaturated solute transport (i.e. immobile water, tortuous flow paths, and non-uniform solute distribution), which become increasingly important as the wetting fluid saturation decreases. Importantly, this MTI was determined independently of chemically driven phase partitioning and is supported by experimental data. Based on this conceptualization, the 1-D equilibrium advection dispersion equation was modified to incorporate the MTI as a lumped parameter which quantifies resistance to (MTI > 1) or promotion of (MTI < 1) of advective solute flux. Analytical solutions to the modified advection-dispersion-reaction equation for pulse and step inputs were developed. Conservative tracer experiments were conducted in variably saturated sand columns to validate both the MTI conceptualization and the inversion method used to estimate the MTI. These experiments involved the use of X-ray absorption spectroscopy integrated with sensor-based measurements of soil moisture, temperature, and electrical conductivity for tracer breakthrough. The mathematical model developed herein adapts traditional macroscopic models of solute transport to account for the non-Fickian pore-scale transport behaviors observed in unsaturated porous media with significant advective flux.


Assuntos
Água Subterrânea , Movimentos da Água , Modelos Teóricos , Porosidade , Solo , Soluções
9.
J Pharm Sci ; 110(2): 771-784, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33035537

RESUMO

Commercial specifications for a new biotherapeutic product are a critical component of the product's overall control strategy that ensures safety and efficacy. This paper describes strategies for setting commercial specifications as proposed by a consortium of industry development scientists. The specifications for some attributes are guided by compendia and regulatory guidance. For other product quality attributes (PQAs), product knowledge and the understanding of attribute criticality built throughout product development should drive specification setting. The foundation of PQA knowledge is an understanding of potential patient impact through an assessment of potency, PK, immunogenicity and safety. In addition to PQA knowledge, the ability of the manufacturing process to consistently meet specifications, typically assessed through statistical analyses, is an important consideration in the specification-setting process. Setting acceptance criteria that are unnecessarily narrow can impact the ability to supply product or prohibit consideration of future convenient dosage forms. Patient-centric specifications enable appropriate control over higher risk PQAs to ensure product quality for the patient, and flexibility for lower risk PQAs for a sustainable supply chain. This paper captures common strategic approaches for setting specifications for standard biotherapeutic products such as monoclonal antibodies and includes considerations for ensuring specifications are patient centric.


Assuntos
Anticorpos Monoclonais , Assistência Centrada no Paciente , Humanos
10.
J Contam Hydrol ; 233: 103661, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32535327

RESUMO

Transport of ten perfluoroalkyl acids (PFAAs) was studied with one-dimensional (1-D) saturated column experiments using four soil types with an organic carbon fraction (foc) range of ~0-0.045. Columns were operated under conditions relevant to aqueous film-forming foam (AFFF)-impacted fire protection training areas to determine the ability of equilibrium transport parameters to describe 1-D PFAA transport, if rate-limited sorption influences PFAA transport, and if kinetic parameters can be used to evaluate factors causing rate-limited sorption. Results of initial screening of PFAA breakthrough found that over half of the breakthrough curves deviated from equilibrium transport and merited further investigation. Subsequent analysis showed that, in many cases, these deviations could be accounted for by considering the range of applicable equilibrium Kd values (i.e. based on standard deviation) applicable to the solid phase. Thus, transport of the majority of PFAAs in 3 soils with foc of 0-0.017 was not impacted by rate-limited sorption. Further, low sorption led to transport that was essentially simultaneous for the majority of PFAAs in these porous media. Exceptions were observed for long-chain PFAAs, and also in a fourth soil with foc of 0.045, which indicated the potential for rate-limited sorption to impact transport in some scenarios. Subsequent flow interruption experiments isolating kinetic behavior confirmed rate-limited sorption caused nonequilibrium transport. Linear free energy relationships (LFERs) developed in previous work to predict the inverse relationship between mass transfer coefficients (k) and sorption parameters (i.e., Kd) were used to estimate values of k for PFAAs in this study. Resulting k values were 10-3 to 10-8 h-1, consistent with previously measured kinetic parameters for other polar and anionic compounds. Models incorporating estimated k values resulted in improved predictions of breakthrough observed in nonequilibrium scenarios (R2 0.83-0.98), but k values will require further validation prior to broader application. This work illustrates rate-limited sorption considerations are needed to describe 1-D column saturated transport for some PFAAs and solid phases. At field scales, subsurface heterogeneity and PFAA precursor transformation may be equally or even more important in determining saturated PFAA transport, but kinetic parameters in this study may help to determine relative contributions of rate-limited sorption to overall transport.


Assuntos
Fluorocarbonos , Poluentes do Solo , Poluentes Químicos da Água , Fluorocarbonos/análise , Solo , Poluentes do Solo/análise , Água
11.
PDA J Pharm Sci Technol ; 73(6): 622-634, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31209169

RESUMO

The application of advanced methodologies such as next-generation sequencing (NGS) and mass spectrometry (MS) to the characterization of cell lines and recombinant proteins has enabled the highly sensitive detection of sequence variants (SVs). However, although these approaches can be leveraged to provide deep insight into product microheterogeneity caused by SVs, they are not used in a standardized manner across the industry. Currently, there is little clarity and consensus on the utilization, timing, and significance of SV findings. This white paper addresses the current practices, logistics, and strategies for the analysis of SVs using a benchmarking survey coordinated by the International Consortium for Innovation & Quality in Pharmaceutical Development (IQ) as well as a series of deliberations among a panel of experts assembled from across the biopharmaceutical industry. Discussion includes current industry experiences including approaches for detection and quantitation of SVs during cell-line and process development, risk assessments, and regulatory feedback. Although SVs are a potential issue for all recombinant protein therapeutics, the scope of this discussion will be limited to SVs produced in mammalian cells. Ultimately, it is our hope that the findings from the survey and deliberations of the committee are useful to decision makers in industry and positions them to respond to findings of SVs in recombinant proteins that are destined for clinical or commercial use in a strategic manner.LAY ABSTRACT: This white paper addresses the current practices, logistics, and strategies for the analysis of amino acid sequence variants using a benchmarking survey coordinated by the International Consortium for Innovation & Quality in Pharmaceutical Development (IQ) as well as a series of deliberations among a panel of experts assembled from across the biopharmaceutical industry. Discussion includes current industry experiences regarding detection and quantitation of SVs during cell-line and process development, risk assessments, and regulatory feedback.


Assuntos
Indústria Farmacêutica/métodos , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Proteínas Recombinantes/química , Análise de Sequência de Proteína/métodos , Sequência de Aminoácidos , Animais , Benchmarking , Humanos , Mamíferos , Espectrometria de Massas/métodos , Medição de Risco/métodos
12.
Anal Chem ; 90(22): 13365-13372, 2018 11 20.
Artigo em Inglês | MEDLINE | ID: mdl-30345749

RESUMO

Methodologies employing LC-MS/MS have been increasingly used for characterization and identification of residual host cell proteins (HCPs) in biopharmaceutical products to ensure their consistent product quality and safety for patients. To improve the sensitivity and reliability for HCP detection, we developed a high pH-low pH two-dimensional reversed phase LC-MS/MS approach in conjunction with offline fraction concatenation. Proof-of -concept was established using a model in which seven proteins spanning a size range of 29-78 kDa are spiked into a purified antibody product to simulate the presence of low-level HCPs. By incorporating a tandem column configuration and a shallow gradient through the second-dimension, all seven proteins were consistently identified at 10 ppm with 100% success rate following LC-MS/MS analysis of six concatenated fractions across multiple analysts, column lots and injection loads. Using the more complex Universal Proteomic Standard 1 (UPS-1) as an HCP model, positive identification was consistently achieved for 19 of the 22 proteins in 8-12 ppm range (10 ppm ±20%). For the first time, we demonstrate an effective LC-MS/MS strategy that not only has high sensitivity but also high reliability for HCP detection. The method performance has high impact on pharmaceutical company practices in using advanced LC-MS/MS technology to ensure product quality and patient safety.


Assuntos
Anticorpos Monoclonais/análise , Cromatografia de Fase Reversa/métodos , Contaminação de Medicamentos , Espectrometria de Massas em Tandem/métodos , Animais , Bovinos , Cricetulus , Escherichia coli/química , Humanos , Sensibilidade e Especificidade
13.
Pharm Res ; 30(1): 167-78, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22956170

RESUMO

PURPOSE: To examine and determine the sites and the kinetics of IgG1 mAb modifications from both in vitro (rat plasma and PBS) and in vivo (rat model) time-course studies. METHODS: A comprehensive set of protein characterization methods, including RPLC/MS, LC-MS/MS, iCIEF, capSEC, and CE-SDS were performed in this report. RESULTS: We demonstrate that plasma incubation and in vivo circulation increase the rate of C-terminal lysine removal, and the levels of deamidation, pyroglutamic acid (pyroE), and thioether-linked (lanthionine) heavy chain and light chain (HC-S-LC). In contrast, incubation in PBS shows no C-terminal lysine removal, and slower rates of deamidation, pyroE, and HC-S-LC formation. Other potential modifications such as oxidation, aggregation, and peptide bonds hydrolysis are not enhanced. CONCLUSION: This study demonstrates that in vivo mAb modifications are not fully represented by in vitro PBS or plasma incubation. The differences in modifications and their rates reflect the dissimilarities of matrices and the impact of enzymes. These observations provide valuable evidence and knowledge in evaluating the criticality of modifications that occur naturally in vivo that might impact formulation design, therapeutic outcome, and critical quality attribute assessments for therapeutic mAb manufacturing and quality control.


Assuntos
Anticorpos Monoclonais Humanizados/sangue , Anticorpos Monoclonais Humanizados/metabolismo , Anticorpos Monoclonais/sangue , Anticorpos Monoclonais/metabolismo , Imunoglobulina G/sangue , Imunoglobulina G/metabolismo , Alanina/análogos & derivados , Alanina/química , Alanina/metabolismo , Animais , Anticorpos Monoclonais/química , Anticorpos Monoclonais Humanizados/química , Cromatografia Líquida , Humanos , Imunoglobulina G/química , Lisina/química , Lisina/metabolismo , Ácido Pirrolidonocarboxílico/química , Ácido Pirrolidonocarboxílico/metabolismo , Ratos , Sulfetos/química , Sulfetos/metabolismo , Espectrometria de Massas em Tandem
16.
J Chromatogr A ; 1216(51): 8904-9, 2009 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-19909961

RESUMO

Size exclusion chromatography is a widely performed analysis of monoclonal antibodies, primarily used to monitor the levels of higher weight molecular species such as aggregates. Owing to the subtleties of these separation mechanisms and frequently observed partial resolutions of components in these separations, many common methods for increasing the method throughput are not practical as they trade off resolution for speed. Short columns, high flow rates and smaller particles are examples of these approaches. In this paper a practical method is demonstrated for injecting samples onto the column in rapid succession and gating the detection window to monitor the elution of each sample individually. At any given instant approximately two samples are eluting through the column. By co-ordinating the injection and detection time windows the samples can be kept discrete and significant throughput enhancements achieved, up to nearly 2-fold improvements are demonstrated. A rudimentary theory is development to show that the throughput improvements can be predicted to approximation by simple column characteristics. Experimental results for a series of monoclonal antibodies demonstrate the equivalency of the method to a conventional injection approach, the throughput increase, and the robustness of the method.


Assuntos
Anticorpos Monoclonais/análise , Cromatografia em Gel/métodos , Cromatografia Líquida/métodos , Reprodutibilidade dos Testes , Fatores de Tempo
17.
J Immunol Methods ; 341(1-2): 59-67, 2009 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-19041317

RESUMO

Resins containing immobilized Staphylococcal Protein A (PA) are widely used in the commercial purification of recombinant human monoclonal antibody (rhuMAb IgG) biotherapeutics. Therefore, a sensitive assay for leached PA is needed to ensure that PA is not present at unacceptable levels as an impurity in the final product. PA impurities are measured by an ELISA using chicken anti-PA antibodies. However, PA in the presence of IgG product forms a PA/IgG complex that interferes in the assay. In this report a multi-product PA ELISA is described, wherein the PA/IgG complex is dissociated by heating in the presence of detergents and chelators prior to the ELISA. The dissociation facilitates the accessibility of the anti-PA antibodies to bind to PA in the immunoassay. Heat is provided by a novel microwave technology which allows brief heating time and high sample throughput using a microtiter plate for sample heating. Thus, broadly applicable dissociation conditions, suitable for all 21 rhMab IgGs tested to date were identified. This approach streamlines the measurement of leached PA, allows higher sample testing throughput, facilitates application across multiple products, and facilitates assay automation. Data comparing in-process samples tested with both the former product-specific ELISA and this new multi-product assay are shown.


Assuntos
Anticorpos Monoclonais/isolamento & purificação , Cromatografia de Afinidade/métodos , Proteína Estafilocócica A/análise , Anticorpos Monoclonais/imunologia , Complexo Antígeno-Anticorpo/análise , Complexo Antígeno-Anticorpo/imunologia , Ensaio de Imunoadsorção Enzimática/métodos , Humanos , Imunoglobulina G/imunologia , Imunoglobulina G/isolamento & purificação , Proteína Estafilocócica A/imunologia
18.
J Proteome Res ; 4(2): 400-9, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15822916

RESUMO

We utilized mass spectrometry to profile cell surface protein differential expression on primary human T helper (Th1 and Th2) cells with the stable isotope labeling by amino acids in cell culture (SILAC) approach. Proteomic and microarray analyses were done concurrently and results were compared for 38 different genes. Although microarray studies displayed wide variability between donors for mRNA expression, these two approaches were shown to be corroborative for most gene products with the exception of a small subset of uncorrelated protein and message levels. The greatest differing Th1 to Th2 ratios were observed for BST2 (bone marrow stromal protein 2) and TRIM (T cell receptor interacting molecule). Both showed greater Th1 expression by proteomic methods, even though mRNA levels were approximately equal for both. To validate this method, we compared protein expression levels of a recently cloned molecule, B and T cell lymphocyte attenuator (BTLA), on Th1 and Th2 cell populations and showed greater protein expression on Th1 cells, which agrees with a previous analysis of higher BTLA mRNA expression in Th1 cells.(1).


Assuntos
Espectrometria de Massas/métodos , Proteômica , Células Th1/química , Células Th2/química , Diferenciação Celular , Células Cultivadas , Humanos , Análise de Sequência com Séries de Oligonucleotídeos , Células Th1/citologia , Células Th2/citologia
19.
Electrophoresis ; 26(7-8): 1500-12, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15765480

RESUMO

A capillary electrophoresis-mass spectrometry (CE-MS) method has been developed to perform routine, automated analysis of low-molecular-weight peptides in human serum. The method incorporates transient isotachophoresis for in-line preconcentration and a sheathless electrospray interface. To evaluate the performance of the method and demonstrate the utility of the approach, an experiment was designed in which peptides were added to sera from individuals at each of two different concentrations, artificially creating two groups of samples. The CE-MS data from the serum samples were divided into separate training and test sets. A pattern-recognition/feature-selection algorithm based on support vector machines was used to select the mass-to-charge (m/z) values from the training set data that distinguished the two groups of samples from each other. The added peptides were identified correctly as the distinguishing features, and pattern recognition based on these peptides was used to assign each sample in the independent test set to its respective group. A twofold difference in peptide concentration could be detected with statistical significance (p-value < 0.0001). The accuracy of the assignment was 95%, demonstrating the utility of this technique for the discovery of patterns of biomarkers in serum.


Assuntos
Biomarcadores/sangue , Eletroforese Capilar/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Automação , Eletroforese em Gel Bidimensional , Humanos
20.
Mol Cell Proteomics ; 4(3): 235-45, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15640519

RESUMO

Reversible phosphorylation of proteins is among the most important post-translational modifications, and elucidation of sites of phosphorylation is essential to understanding the regulation of key cellular processes such as signal transduction. Unfortunately phosphorylation site mapping is as technically challenging as it is important. Limitations in the traditional method of Edman degradation of (32)P-labeled phosphoproteins have spurred the development of mass spectrometric methods for phosphopeptide identification and sequencing. To assess the practical contributions of the various technologies we conducted a literature search of publications using mass spectrometry to discover previously unknown phosphorylation sites. 1281 such phosphorylation sites were reported in 203 publications between 1992 and 2003. This review examines and catalogs those methods, identifies the trends that have emerged in the past decade, and presents representative examples from among these methods.


Assuntos
Fosfoproteínas/análise , Animais , Humanos , Espectrometria de Massas/métodos , Mapeamento de Peptídeos , Fosfopeptídeos/análise , Fosforilação , Processamento de Proteína Pós-Traducional
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...