Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
JAMA Netw Open ; 6(12): e2346545, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38060226

RESUMO

Importance: Pediatric ventilator-associated events (PedVAEs, defined as a sustained worsening in oxygenation after a baseline period of stability or improvement) are useful for surveillance of complications from mechanical ventilation. It is unclear whether interventions to mitigate known risk factors can reduce PedVAE rates. Objective: To assess whether adherence to 1 or more test factors in a quality improvement bundle was associated with a reduction in PedVAE rates. Design, Setting, and Participants: This multicenter quality improvement study obtained data from 2017 to 2020 for patients who were mechanically ventilated and cared for in neonatal, pediatric, and cardiac intensive care units (ICUs). These ICUs were located in 95 hospitals participating in the Children's Hospitals' Solutions for Patient Safety (SPS) network in North America. Data analyses were performed between September 2021 and April 2023. Intervention: A quality improvement bundle consisted of 3 test factors: multidisciplinary apparent cause analysis, daily discussion of extubation readiness, and daily discussion of fluid balance goals. This bundle was distributed to a subgroup of hospitals that volunteered to participate in a collaborative PedVAE prevention initiative under the SPS network guidance in July 2018. Main Outcomes and Measures: Each SPS network hospital submitted monthly PedVAE rates from January 1, 2017, to May 31, 2020, and test factor data were submitted from July 1, 2018, to May 31, 2020. Analyses focused on hospitals that reliably submitted PedVAE rate data, defined as outcomes data submission through May 31, 2020, for at least 80% of the baseline and postbaseline periods. Results: Of the 95 hospitals in the SPS network that reported PedVAE data, 21 were grouped in the Pioneer cohort and 74 in the non-Pioneer cohort. Only 12 hospitals (57%) from the 21 Pioneer hospitals and 33 (45%) from the 74 non-Pioneer hospitals were considered to be reliable reporters of outcome data. Among the 12 hospitals, the PedVAE rate decreased from 1.9 to 1.4 events per 1000 ventilator days (absolute rate difference, -0.6; 95% CI, -0.5 to -0.7; P < .001). No significant change in the PedVAE rate was seen among the 33 hospitals that reliably submitted PedVAE rates but did not implement the bundle. Of the 12 hospitals, 3 that reliably performed daily discussion of extubation readiness had a decrease in PedVAE rate from 2.6 to 1.2 events per 1000 ventilator days (absolute rate difference, -1.4; 95% CI, -1.0 to -1.7; P < .001), whereas the other 9 hospitals that did not implement this discussion did not have a decrease. Conclusions and Relevance: This study found that a multicenter quality improvement intervention targeting PedVAE risk factors was associated with a substantial reduction in the rate of PedVAEs in hospital ICUs. The findings suggest that ICU teams seeking to reduce PedVAEs incorporate daily discussion of extubation readiness during morning rounds.


Assuntos
Melhoria de Qualidade , Respiração Artificial , Recém-Nascido , Humanos , Criança , Respiração Artificial/efeitos adversos , Unidades de Terapia Intensiva , Ventiladores Mecânicos , Hospitais Pediátricos
2.
Jt Comm J Qual Patient Saf ; 48(4): 196-204, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35181251

RESUMO

BACKGROUND: Rapid response (RR) systems' impact on clinical outcomes is influenced by institutional social factors. This study applied the realist evaluation (context-mechanism-outcomes) framework to review significant RRs defined as REACT (Rapid Escalation After Critical Transfer) events for appraising a pediatric RR system. METHODS: REACT events included all RRs with cardiopulmonary arrest (CPA) and/or ventilation and/or hemodynamic support instituted within 24 hours after RR. A continuous quality improvement process was employed to identify, debrief, and review REACT events to recognize and act on RR mechanistic and contextual deficiencies. The aim was to decrease REACT events with mechanistic/contextual gaps categorized into crisis resource management (CRM) themes by 25% over three years while ensuring process sustainability. RESULTS: From 2015 to 2019, 5,581 RR events occurred, of which 67.2% transferred to ICU, and 1,392 (24.9%) were identified as REACTs. In the first two years, 100% identification and review within three months of 90% REACTs was accomplished. One hundred percent of the 17 providers ascertained that the process was safe and transparent, and 80.0% of respondents expressed their commitment from perceived benefit to patient care. Over five years, the proportion of REACTs with CRM gaps decreased from 62.3% to 26.5%, those with multiple deficiencies reduced from 72.5% to 23.2%, and CPAs outside ICUs decreased from 15 to 3 per year. Improvement actions included modifications to RR system (activation, process, and management), hospital (resources and policies), dedicated RR training, and sharing of positive feedback. CONCLUSION: The realist evaluation framework facilitated holistic assessment of an RR system. Review of REACTs was feasible, sustainable, and yielded useful information to guide systemwide improvement.


Assuntos
Parada Cardíaca , Hospitais , Criança , Parada Cardíaca/terapia , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...