Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Biomicrofluidics ; 6(2): 24132, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23785388

RESUMO

A simple microfluidic 3D hydrodynamic flow focusing device has been developed and demonstrated quantitative determinations of quantum dot 525 with antibody (QD525-antibody) and hemagglutinin epitope tagged MAX (HA-MAX) protein concentrations. This device had a step depth cross junction structure at a hydrodynamic flow focusing point at which the analyte stream was flowed into a main detection channel and pinched not only horizontally but also vertically by two sheath streams. As a result, a triangular cross-sectional flow profile of the analyte stream was formed and the laser was focused on the top of the triangular shaped analyte stream. Since the detection volume was smaller than the radius of laser spot, a photon burst histogram showed Gaussian distribution, which was necessary for the quantitative analysis of protein concentration. By using this approach, a linear concentration curve of QD525-antibody down to 10 pM was demonstrated. In addition, the concentration of HA-MAX protein in HEK293 cell lysate was determined as 0.283 ± 0.015 nM. This approach requires for only 1 min determining protein concentration. As the best of our knowledge, this is the first time to determinate protein concentration by using single molecule detection techniques.

2.
Rev Sci Instrum ; 79(12): 125105, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19123590

RESUMO

A fiber optic reflectometer (FOR) technique featuring a single fiber probe is investigated for its feasibility of measuring the bubble velocity, diameter, and void fraction in a multiphase flow. The method is based on the interference of the scattered signal from the bubble surface with the Fresnel reflection signal from the tip of the optical fiber. Void fraction is obtained with a high accuracy if an appropriate correction is applied to compensate the underestimated measurement value. Velocity information is accurately obtained from the reflected signals before the fiber tip touches the bubble surface so that several factors affecting the traditional dual-tip probes such as blinding, crawling, and drifting effects due to the interaction between the probe and bubbles can be prevented. The coherent signals reflected from both the front and rear ends of a bubble can provide velocity information. Deceleration of rising bubbles and particles due to the presence of the fiber probe is observed when they are very close to the fiber tip. With the residence time obtained, the bubble chord length can be determined by analyzing the coherent signal for velocity determination before the deceleration starts. The bubble diameters are directly obtained from analyzing the signals of the bubbles that contain velocity information. The chord lengths of these bubbles measured by FOR represent the bubble diameters when the bubble shape is spherical or represent the minor axes when the bubble shape is ellipsoidal. The velocity and size of bubbles obtained from the FOR measurements are compared with those obtained simultaneously using a high speed camera.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA