Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Ultrasound Med ; 29(5): 735-40, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20427785

RESUMO

OBJECTIVE: The purpose of this study was to evaluate the value of contrast-enhanced ultrasonography (CEUS) in differential diagnosis of superficial lymphadenopathy. METHODS: Ninety-four superficial enlarged lymph nodes in 94 patients were studied by conventional ultrasonography (gray scale and color Doppler) and CEUS. Contrast-enhanced sonograms were analyzed using contrast-specific quantification software. All of the results were compared with pathologic diagnoses. RESULTS: Of the 94 lymph nodes examined, 44 were benign and 50 were malignant (33 metastases and 17 lymphomas). The sensitivity, specificity, and accuracy of conventional ultrasonography in differential diagnosis between benign and malignant nodes were 51%, 47%, and 55%, respectively. Contrast-enhanced ultrasonography showed intense homogeneous enhancement in 39 of 44 benign lymph nodes, inhomogeneous enhancement in 32 of 33 metastases, and intense homogeneous enhancement and absence of perfusion in 9 of 17 and 6 of 17 lymphomas, respectively. The sensitivity specificity, and accuracy of CEUS were 84%, 79%, and 80%. After time-intensity curve gamma variates were calculated, the area under the curve of the benign lymph nodes was greater than those of the metastatic lymph nodes and lymphomas (P < .01). CONCLUSIONS: These results indicate that the use of CEUS and contrast-specific software has a higher degree of diagnostic accuracy than conventional ultrasonography for evaluations of superficial lymphadenopathy. The contrast enhancement patterns and time-intensity curves provide valuable diagnostic information for differential diagnosis of benign and malignant lymph nodes.


Assuntos
Linfonodos/diagnóstico por imagem , Doenças Linfáticas/diagnóstico por imagem , Fosfolipídeos , Hexafluoreto de Enxofre , Adolescente , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia , Adulto Jovem
2.
Int J Cardiovasc Imaging ; 26(2): 125-33, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19802729

RESUMO

Whether distal protection devices (DPDs) during percutaneous coronary intervention (PCI) can improve myocardial function in patients with acute myocardial infarction (AMI) is still under debate. Using tissue Doppler imaging (TDI), we evaluate the global and regional left ventricular systolic and diastolic functions in patients with anterior AMI using DPDs compared with conventional PCI. Ninety-six patients with anterior AMI were randomly assigned to either PCI with DPDs (DPD, n = 46) or traditional PCI (control, n = 50) groups. At the 3- and 6-month follow-ups, the DPD group had a higher left ventricular ejection fraction than the control group (51.6 +/- 3.6 vs. 49.3 +/- 5.3% and 53.0 +/- 3.7 vs. 50.8 +/- 5.2%, respectively; both P < 0.05). Moreover, peak systolic (S (a)) and early diastolic (E (a)) mitral annular velocities obtained by TDI were significantly higher in the DPD group than in the control group (S (a): 7.57 +/- 0.53 vs. 7.12 +/- 0.62 cm/s and 7.71 +/- 0.63 vs. 7.32 +/- 0.59 cm/s; E (a): 7.23 +/- 0.78 vs. 6.89 +/- 0.86 cm/s and 7.49 +/- 0.69 vs. 7.04 +/- 0.85 cm/s, respectively; all P < 0.05). However, systolic and diastolic regional myocardial velocities significantly improved in the DPD group from the 1-month follow-up compared with those in the control group (all P < 0.05). Patients who received treatment with DPDs experienced enhanced improvement of cardiac function. Thus, anterior AMI patients can benefit from DPDs during PCI.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Ecocardiografia Doppler de Pulso , Embolia/prevenção & controle , Infarto do Miocárdio/terapia , Fenômeno de não Refluxo/prevenção & controle , Função Ventricular Esquerda , Adulto , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Circulação Coronária , Diástole , Embolia/diagnóstico por imagem , Embolia/etiologia , Embolia/fisiopatologia , Desenho de Equipamento , Feminino , Humanos , Masculino , Microcirculação , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia , Fenômeno de não Refluxo/diagnóstico por imagem , Fenômeno de não Refluxo/etiologia , Fenômeno de não Refluxo/fisiopatologia , Seleção de Pacientes , Valor Preditivo dos Testes , Volume Sistólico , Sístole , Terapia Trombolítica , Fatores de Tempo , Resultado do Tratamento
3.
Ultrasound Med Biol ; 35(5): 748-55, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19410132

RESUMO

To compare the feasibility of real-time myocardial contrast echocardiography (MCE) in rats with infusion and bolus administration of a second-generation ultrasound contrast agent BR1. B-mode real-time MCE was performed in 12 Sprague Dawley rats following the BR1 infusion or bolus injection. The myocardium signal intensity (SI) was plotted against time and was fitted to exponential functions. The plateau SI (A) and rate of SI increase (beta) for the infusion study and peak signal intensity (PSI) for the bolus study were obtained. (99m)Tc-Sestamibi and Evans blue were used to assess myocardial blood perfusion and to calculate the myocardium perfusion defect area ex vivo. High-quality real-time MCE images were successfully obtained using each method. At baseline, all LV segments showed even contrast distribution. Following left anterior descending coronary artery (LAD) ligation, significant perfusion defect was observed in LAD beds with a significantly decreased A* beta and PSI values compared with LCx beds (Infusion: A*beta (LAD): 5.42 +/- 1.57 dB, A*beta (LCx): 46.52 +/- 5.32 dB, p < 0.05; Bolus: PSI (LAD): 2.11 +/- 0.67 dB, PSI (LCx): 20.68 +/- 0.72 dB, p < 0.05), which was consistent with (99m)Tc-Sestamibi distribution findings. Myocardial perfusion defect areas, assessed by both methods, showed no differences and showed good correlation with Evans blue staining. ED frames were more favorable for imaging analysis. Both infusion and bolus administration of the contrast agent combined with real-time MCE technique can provide a reliable and noninvasive approach for myocardial perfusion assessment in rats and the infusion method was more suitable for quantitative analysis of myocardial blood flow.


Assuntos
Ecocardiografia/métodos , Fosfolipídeos/administração & dosagem , Hexafluoreto de Enxofre/administração & dosagem , Animais , Meios de Contraste/administração & dosagem , Circulação Coronária , Estudos de Viabilidade , Hemodinâmica/efeitos dos fármacos , Interpretação de Imagem Assistida por Computador/métodos , Infusões Intravenosas , Injeções Intravenosas , Ratos , Ratos Sprague-Dawley
4.
J Ultrasound Med ; 27(6): 867-74, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18499846

RESUMO

OBJECTIVE: The purpose of this study was to investigate the feasibility of percutaneous microwave coagulation therapy (PMCT) guided by contrast-enhanced ultrasonography (CEUS) for controlling active bleeding in rabbit livers. METHODS: Twenty actively bleeding rabbit liver models, produced with an 18-gauge semiautomatic biopsy needle and confirmed with CEUS, were randomly divided into 2 groups: a PMCT group (n=10, with a microwave antenna placed into the bleeding site under ultra-sonographic guidance and worked at 60 W for 30 seconds on average) and a control group (n=10, with the active bleeding site not treated). After therapy procedures were performed, lactated Ringer's solution resuscitation was then performed in both groups to maintain the mean arterial pressure at 70 mm Hg for 1 hour. The intraperitoneal blood loss, total resuscitation volume, mean arterial pressure, and hematocrit value were recorded. Macroscopic and microscopic examinations were performed at the end of the study. RESULTS: After PMCT, the former bleeding site appeared on CEUS as a round or an oval area devoid of contrast. The PMCT group had lower blood loss (30.4+/-7.2 versus 101.6 +/- 18.2 mL; P< .05) and a lower total resuscitation volume (56.5+/-10 versus 186+/-36.6 mL; P< .05) than the control group. The mean hematocrit value in the PMCT group was significantly higher than that in the control group (26%+/-4% versus 19%+/-4%; P< .05) at the end of the experiment. CONCLUSIONS: Contrast-enhanced ultrasonographically guided PMCT significantly decreased blood loss in a rabbit model of active liver bleeding. It provides a simple and quick method to control blood loss in liver injuries with active bleeding.


Assuntos
Hemorragia/terapia , Fígado/irrigação sanguínea , Micro-Ondas/uso terapêutico , Ultrassonografia de Intervenção , Animais , Meios de Contraste , Estudos de Viabilidade , Hemorragia/diagnóstico por imagem , Hemostasia , Fígado/diagnóstico por imagem , Fosfolipídeos , Coelhos , Hexafluoreto de Enxofre
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...