Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Trans Indian Natl Acad Eng ; 5(2): 289-294, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-38624417

RESUMO

Chitra Disinfection Gateway is meant for the decontamination of personnel entering a cleaner private space from a public space. This is equipped with an arrangement for generating hydrogen peroxide mist and ultraviolet rays. Hydrogen peroxide mist will decontaminate clothes, hands and the bags a person carries. The ultraviolet system will decontaminate the chamber once the person has moved out. The system is controlled electronically by sensors and actuators. The sensors fixed in the chamber detect the entry of a person and initiates the hydrogen peroxide atomization process. The person is required to walk through the chamber. When the person exits the chamber, the system will put off the hydrogen peroxide atomization system and will turn on the UV lamp inside the chamber to decontaminate it. The ultraviolet system will be ON for a predefined time and after the process, the next person can enter the walkway. The whole process takes a maximum of 40 s. The safety and efficacy of the system have been validated experimentally through both in vivo and in vitro studies.

2.
Proc Inst Mech Eng H ; 231(8): 758-765, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28395636

RESUMO

Average age group of heart valve replacement in India and most of the Third World countries is below 30 years. Hence, the valve for such patients need to be designed to have a service life of 50 years or more which corresponds to 2000 million cycles of operation. The purpose of this study was to assess the structural performance of the TTK Chitra tilting disc heart valve model TC2 and thereby address its durability. The TC2 model tilting disc heart valves were assessed to evaluate the risks connected with potential structural failure modes. To be more specific, the studies covered the finite element analysis-based fatigue life prediction and accelerated durability testing of the tilting disc heart valves for nine different valve sizes. First, finite element analysis-based fatigue life prediction showed that all nine valve sizes were in the infinite life region. Second, accelerated durability test showed that all nine valve sizes remained functional for 400 million cycles under experimental conditions. The study ensures the continued function of TC2 model tilting disc heart valves over duration in excess of 50 years. The results imply that the TC2 model valve designs are structurally safe, reliable and durable.


Assuntos
Próteses Valvulares Cardíacas , Análise de Elementos Finitos , Desenho de Prótese , Falha de Prótese , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...