Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 93(5): 963-970, 2019 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-30430723

RESUMO

OBJECTIVES: To evaluate the in vivo feasibility of aortography with one accurately timed diastolic low-volume contrast injection for quantitative assessment of aortic regurgitation (AR) post transcatheter aortic valve replacement (TAVR). BACKGROUND: With the rise of a minimalistic approach for TAVR, aortography (re)emerges as a pragmatic tool for AR assessment. In a mock circulation system, we have validated the accuracy of a single diastolic injection triggered by electrocardiogram (ECG) with low-contrast volume. METHODS: Two-phase experiment: first, a series of aortograms were performed in a porcine model, with 8 mL of contrast using the synchronized (SYNC) and the conventional non-synchronized (NS) injections. In a second phase, we developed a model of AR by inserting partially unsheathed Wallstents of 6-10 mm of diameter across the pig's aortic valve, performing SYNC injections with 8 mL of contrast and NS injections with 8 mL and 15 mL (rate: 20 mL/sec). Respective accuracies of SYNC vs. NS were assessed using Passing-Bablock regression. An angiography core laboratory performed quantitative AR assessment with videodensitometry (VD-AR). RESULTS: The SYNC injections produced higher opacification of the aortic root compared with NS injections (P = 0.04 for density). In the second phase, a regression line for predicting VD-AR based on the SYNC injection resulted in a lower intercept and a slope closer to the line of identity (y = 11.9 + 0.79x, P < 0.001, r2 = 0.94) with the NS-8 mL than with the NS-15 mL injection (y = 26.5 + 0.55x, P < 0.001, r2 = 0.81). CONCLUSION: Synchronized diastolic injection with low contrast volume produced denser images in the aortic root and more accurate than the conventional injection; thus, may be an appealing alternative for assessment of AR post TAVR.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Aortografia , Meios de Contraste/administração & dosagem , Hemodinâmica , Iopamidol/administração & dosagem , Animais , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/fisiopatologia , Diástole , Modelos Animais de Doenças , Eletrocardiografia , Estudos de Viabilidade , Feminino , Frequência Cardíaca , Injeções , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Sus scrofa , Fatores de Tempo
2.
EuroIntervention ; 13(13): 1527-1535, 2018 01 20.
Artigo em Inglês | MEDLINE | ID: mdl-28994656

RESUMO

AIMS: Videodensitometric assessment of aortography provides a periprocedural quantitation of prosthetic valve regurgitation (PVR) after transcatheter aortic valve implantation. We sought to compare the videodensitometric parameters of PVR severity to the regurgitation fraction (RF) in a controlled in vitro setting. METHODS AND RESULTS: In a mock circulation system, a transcatheter balloon-expandable valve inserted at the aortic valve position was gradually deformed to induce different grades of paravalvular leakage and the RF was measured with a transonic flow probe. Contrast aortography was performed and the following videodensitometric parameters were generated: left ventricle aortic regurgitation (LV-AR), LV outflow tract AR (LVOT-AR), quantitative regurgitation assessment (qRA) index, relative maximum density (relative max), and maximum upslope of the LV time-density curve. The correlation was substantial between videodensitometric parameters (LV-AR, LVOT-AR, qRA index, relative max, and maximum upslope) and RF (r2=0.96, 0.96, 0.93, 0.87, and 0.93; p<0.001 for all). LV-AR (region of interest [ROI]=entire LV) and LVOT-AR (ROI=LVOT) were not different (p=0.51) and were strongly correlated (r2=0.99) with a mean difference of 1.92% (95% limits of agreement: ±2.83). The correlations of LV-AR and LVOT-AR with RF were stronger when more than one cardiac cycle was included in the analysis (one cycle: r2=0.85 and r2=0.83; four cycles: r2=0.96 and r2=0.96, for LV-AR and LVOT-AR, respectively). Including more cycles beyond four did not improve accuracy. CONCLUSIONS: Quantitative assessment of PVR by videodensitometry of aortograms strongly correlates with the actual RF in a controlled in vitro setting. Accuracy is improved by including more than one cardiac cycle in the analysis.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Aortografia/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Hemodinâmica , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Densitometria , Humanos , Modelos Anatômicos , Modelos Cardiovasculares , Valor Preditivo dos Testes , Desenho de Prótese , Índice de Gravidade de Doença
3.
EuroIntervention ; 13(11): 1288-1295, 2017 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-28691911

RESUMO

AIMS: In the minimalist transcatheter aortic valve implantation (TAVI) era, the usage of transoesophageal echocardiography has become restricted. Conversely, aortography has gained clinical ground in quantifying prosthetic valve regurgitation (PVR) during the procedure. In a mock circulation system, we sought to compare the contrast volume required and the accuracy of aortographic videodensitometric PVR assessment using a synchronised diastolic and standard (non-synchronised) injection aortography. METHODS AND RESULTS: Synchronised diastolic injection triggered by the signal stemming from the mock circulation was compared with standard non-synchronised injection. A transcatheter heart valve was implanted and was deformed step by step by advancing a screw perpendicularly to the cage of the valve in order to create increasing PVR. Quantitative measurement of PVR was derived from time-density curves of both a reference area (aortic root) and a region of interest (left ventricle) developed by a videodensitometric software. The volume of contrast required for the synchronised diastolic injection was significantly less than in the non-synchronised injection (8.1 [7.9-8.5] ml vs. 19.4 [19.2-19.9] ml, p<0.001). The correlation between the two methods was substantial (Spearman's coefficient rho ranging from 0.991 to 0.968). Intraobserver intra-class correlation coefficient for both methods of injection was 0.999 (95% CI: 0.996-1.000) for the synchronised diastolic and 0.999 (95% CI: 0.996-1.000) for the non-synchronised injection group. The mean difference in the rating was 0.17% and limits of agreement were ±1.64% for both groups. CONCLUSIONS: A short synchronised diastolic injection enables contrast volume reduction during aortography without compromising the accuracy of the quantitative assessment of PVR using videodensitometry.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Aortografia/métodos , Meios de Contraste/administração & dosagem , Modelos Anatômicos , Modelos Cardiovasculares , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/fisiopatologia , Diástole , Humanos , Injeções , Variações Dependentes do Observador , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...