Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Orthopedics ; 40(6): e1044-e1049, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-28968480

RESUMO

Perioperative blood loss after total knee arthroplasty (TKA) affects postoperative recovery. Tranexamic acid is safe and efficient in reducing blood loss without increasing thromboembolic events. Epsilon-aminocaproic acid (ε-ACA) is less expensive than and as safe as tranexamic acid. Its efficiency when locally applied in TKA is unknown. The authors retrospectively followed 240 consecutive patients treated by 1 surgeon with TKA from January 2012 to August 2016. From January 2013 to May 2015, the authors topically applied 5 g of ε-ACA to the open wound after tourniquet release and before closure (ε-ACA-after-tourniquet-release group). From August 2015 to August 2016, the authors topically applied 5 g of ε-ACA intraoperatively to the open wound 3 minutes before tourniquet release (ε-ACA-before-tourniquet-release group). The last 80 patients not receiving ε-ACA (control group), the 80 patients in the ε-ACA-after-tourniquet-release group, and the 80 patients in the ε-ACA-before-tourniquet-release group were compared regarding blood loss, treatment costs, and thromboembolic complications. The mean±SD calculated blood loss was 1478.8±367.1 mL for the control group, 1424.0±249.3 mL for the ε-ACA-after-tourniquet-release group, and 1052.3±419.1 mL for the ε-ACA-before-tourniquet-release group (P<.05). Using ε-ACA before tourniquet release reduced the length of hospital stay by 0.7 days (P<.05) compared with not using ε-ACA, leading to cost savings of $1547.37 per patient. One patient in the ε-ACA-before-tourniquet-release group and 1 patient in the control group developed a venous thromboembolism in the postoperative period. Epsilon-aminocaproic acid significantly reduces blood loss after TKA when topically applied before tourniquet release. Its application reduced costs by decreasing the length of hospital stay and did not increase thromboembolic events. [Orthopedics. 2017; 40(6):e1044-e1049.].


Assuntos
Ácido Aminocaproico/uso terapêutico , Artroplastia do Joelho , Perda Sanguínea Cirúrgica/prevenção & controle , Hemostasia Cirúrgica/métodos , Hemostáticos/uso terapêutico , Tempo de Internação/estatística & dados numéricos , Hemorragia Pós-Operatória/prevenção & controle , Administração Tópica , Idoso , Perda Sanguínea Cirúrgica/estatística & dados numéricos , Esquema de Medicação , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Hemorragia Pós-Operatória/epidemiologia , Estudos Retrospectivos , Torniquetes , Resultado do Tratamento
2.
Orthopedics ; 39(6): 371-379, 2016 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-27459144

RESUMO

Total hip arthroplasty (THA) has been performed for nearly 50 years. Between 2006 and 2012, more than 600,000 metal-on-metal THA procedures were performed in the United States. This article reviews the production of metal wear debris in a metal-on-metal articulation and the interaction of cobalt and chromium ions that ultimately led to a dramatic decline in the use of metal-on-metal THA articulations. Additionally, the article reviews mechanisms of metal wear, the biologic reaction to cobalt and chromium ions, the clinical presentation of failing metal-on-metal articulations, and current diagnostic strategies. Further, the article discusses the use of inflammatory markers, metal ion levels, radiographs, metal artifact reduction sequence magnetic resonance imaging, and ultrasound for failed metal-on-metal THA procedures. When adopting new technologies, orthopedic surgeons must weigh the potential increased benefits against the possibility of new mechanisms of failure. Metal-on-metal bearings are a prime example of the give and take between innovation and clinical results, especially in the setting of an already successful procedure such as THA. [Orthopedics. 2016; 39(6):371-379.].


Assuntos
Artroplastia de Quadril/métodos , Prótese de Quadril , Metais , Falha de Prótese , Biomarcadores , Cromo , Cobalto , Humanos
3.
Int Orthop ; 40(10): 2019-2023, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26744168

RESUMO

PURPOSE: To evaluate the peri-operative blood loss with the use of epsilon-aminocaproic acid (ε-ACA) in total hip arthroplasty (THA). METHODS: One hundred sixty patients treated with THA were followed; 5 g ε-ACA diluted in 100 ml normal saline was applied intra-operatively. Eighty patients not receiving ε-ACA (non ε-ACA group) and eighty patients receiving ε-ACA (ε-ACA group) were compared regarding blood loss, need of transfusion, and thrombo-embolic complications. RESULTS: Blood loss (mean ± SD) for the non ε-ACA group was 1678 ± 515 ml and for the ε-ACA group 1403 ± 417 ml (p < 0.05). In the non ε-ACA group 23 patients needed blood transfusions compared to ten patients in the ε-ACA group (p < 0.05). Cost savings were $284.39 per patient. No patient in either group developed a thrombo-embolic complication. CONCLUSIONS: This study demonstrates a significant reduction in peri-operative blood loss after THA with topically applied ε-ACA. The application of ε-ACA reduced costs by lowering transfusion rates and did not increase thrombo-embolic events. ε-ACA is safe and effective in reducing blood loss and cost-efficient in THA.


Assuntos
Ácido Aminocaproico/uso terapêutico , Antifibrinolíticos/uso terapêutico , Artroplastia de Quadril/efeitos adversos , Perda Sanguínea Cirúrgica/prevenção & controle , Administração Tópica , Idoso , Artroplastia de Quadril/métodos , Transfusão de Sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tromboembolia/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...