Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
1.
Biosci Microbiota Food Health ; 43(2): 100-109, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38577893

RESUMO

Sustainable livestock production requires reducing competition for food and feed resources and increasing the utilization of food by-products in livestock feed. This study describes the establishment of an anaerobic batch culture model to simulate pig microbiota and evaluate the effects of a food by-product, wakame seaweed stalks, on ex vivo microbial communities. We selected one of the nine media to support the growth of a bacterial community most similar in composition and diversity to that observed in pig donor feces. Supplementation with wakame altered the microbial profile and short-chain fatty acid composition in the ex vivo model, and a similar trajectory was observed in the in vivo pig experimental validation. Notably, the presence of wakame increased the abundance of Lactobacillus species, which may have been due to cross-feeding with Bacteroides. These results suggest the potential of wakame as a livestock feed capable of modulating the pig microbiome. Collectively, this study highlights the ability to estimate the microbiome changes that occur when pigs are fed a specific feed using an ex vivo culture model.

2.
Vaccines (Basel) ; 12(4)2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38675794

RESUMO

Previously, it was shown that intranasally (i.n.) administered Corynebacterium pseudodiphtheriticum 090104 (Cp) or CP-derived bacterium-like particles (BLPs) improve the immunogenicity of the pneumococcal conjugate vaccine (PCV). This work aimed to deepen the characterization of the adjuvant properties of Cp and CP-derived BLPs for their use in the development of pneumococcal vaccines. The ability of Cp and CP-derived BLPs to improve both the humoral and cellular specific immune responses induced by i.n. administered polysaccharide-based commercial pneumococcal vaccine (Pneumovax 23®) and the chimeric recombinant PSPF (PsaA-Spr1875-PspA-FliC) protein was evaluated, as well as the protection against Streptococcus pneumoniae infection in infant mice. Additionally, whether the immunization protocols, including Cp and CP-derived BLPs, together with the pneumococcal vaccines can enhance the resistance to secondary pneumococcal pneumonia induced after inflammatory lung damage mediated by the activation of Toll-like receptor 3 (TLR3) was assessed. The results showed that both Cp and CP-derived BLPs increased the immunogenicity and protection induced by two pneumococcal vaccines administered through the nasal route. Of note, the nasal priming with the PSPF T-dependent antigen co-administered with Cp or CP-derived BLPs efficiently stimulated humoral and cellular immunity and increased the resistance to primary and secondary pneumococcal infections. The CP-derived BLPs presented a stronger effect than live bacteria. Given safety concerns associated with live bacterium administration, especially in high-risk populations, such as infants, the elderly, and immunocompromised patients, BLPs emerge as an attractive mucosal adjuvant to improve the host response to pneumococcal infections and to enhance the vaccines already in the market or in development.

3.
Front Microbiol ; 15: 1324999, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38343714

RESUMO

The emergence and spread of antibiotic resistance threat forced to explore alternative strategies for improving the resistance to pathogens in livestock production. Probiotic lactic acid bacteria represent an alternative for this objective. In this study, seven Lactiplantibacillus plantarum strains from porcine colostrum and milk were isolated, identified and characterized in terms of their abilities to modulate immunity in porcine intestinal epithelial (PIE) cells. Then, two potential immunoregulatory strains were studied in terms of their ability to utilize and grow in wakame (Undaria pinnafida). Isolates were identified by 16S rRNA gene and evaluated by studying their interaction with PIE cells. The expressions of peptidoglycan recognition proteins (PGRPs), nucleotide-binding oligomerization domain (NODs), host defense peptides (pBD), and type I interferons (IFNs) were evaluated by RT-qPCR. The strain 4M4417 showed a remarkable capacity to differentially regulate the expression of PGRP1, PGRP3, NOD1, NOD2, and pBD1 in PIE cells. On the other hand, the strain 4M4326 was the most efficient to improve the expression of IFN-α and IFN-ß in PIE cells challenged with poly (I:C). Both L. plantarum 4M4326 and 4M4417 were characterized in terms of their ability to utilize wakame. Results demonstrated that both strains efficiently grew in wakame-based broth. Our results suggest that L. planatrum 4M4326 and 4M4417 are interesting candidates to develop immunomodulatory feeds based on wakame utilization. These new immunosynbiotic feeds could help to reduce severity of intestinal infections and improve immune health status in pigs.

4.
Sci Rep ; 14(1): 1274, 2024 01 13.
Artigo em Inglês | MEDLINE | ID: mdl-38218913

RESUMO

A short keel-cortex distance (KCD), especially to the posterior cortex, is a potential risk factor for tibial plateau fracture after Oxford mobile-bearing unicompartmental knee arthroplasty (OUKA). This study aimed to evaluate the effect of tibial component alignment in the coronal plane and tibial proximal morphology on the KCD. Included in this study were 51 patients scheduled for primary Oxford medial unicompartmental knee arthroplasty (UKA). The anterior and posterior KCD were preoperatively assessed using 3D simulation software with the component set perpendicular to the tibial mechanical axis (neutral), 3° valgus, 3° varus, and 6° varus, relative to neutral alignment. We evaluated the existence of overhanging medial tibial condyle where the medial eminence line, the line including the medial tibial eminence parallel to the tibial axis, passes outside of the tibial shaft. In all component alignments, patients with a medial overhanging condyle had significantly shorter posterior KCD than those without. In patients with a medial overhanging condyle, the posterior KCD significantly increased when the tibial component was placed in 3° varus (4.6 ± 1.5 mm, P = 0.003 vs neutral, P < 0.001 vs 3° valgus) and 6° varus (5.0 ± 1.4 mm, P < 0.001 vs neutral, P < 0.001 vs 3° valgus) compared with in neutral (3.5 ± 1.9 mm) or 3° valgus (2.8 ± 1.8 mm). In OUKA, varus implantation increased the KCD. This could potentially decrease the risk of fracture, even in knees with the overhanging medial condyle. Conversely, valgus implantation of the tibial component shortened the KCD, and should therefore be avoided.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Fraturas da Tíbia , Humanos , Artroplastia do Joelho/efeitos adversos , Prótese do Joelho/efeitos adversos , Tíbia/cirurgia , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Fraturas da Tíbia/etiologia , Fatores de Risco , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Osteoartrite do Joelho/complicações , Estudos Retrospectivos
5.
Osteoarthritis Cartilage ; 32(1): 28-40, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37648149

RESUMO

OBJECTIVE: Krüppel-like zinc finger transcription factors (KLFs) play diverse roles in mammalian cell differentiation and development. In this study, we investigated the function of KLF15 in the progression of osteoarthritis (OA). METHODS: 0Destabilization of the medial meniscus (DMM) surgery was performed in 10-week-old male wild-type control (WT) mice and cartilage-specific KLF15 knockout (KO) mice. Histological analysis, immunohistochemistry, and terminal deoxynucleotidyl transferase deoxyuridine triphosphate nick-end labeling staining were performed. Morphological changes were measured using microcomputed tomography. Six mice from each group were analyzed (total number of mice analyzed: 60). In vitro, immunofluorescence, quantitative reverse transcription-polymerase chain reaction, and western blot analyses were performed. RESULTS: KLF15 KO DMM mice exhibited significant cartilage degradation compared to WT mice. According to the Osteoarthritis Research Society International cartilage OA-histopathology scoring system, the mean sum score in KLF15 KO mice was significantly higher than that in WT mice at 8 weeks after surgery. Immunohistochemistry results revealed KLF15 KO mice exhibited reduced peroxisome proliferator-activated receptor gamma (PPARγ) expression, increased pIKKα/ß, a disintegrin-like and metalloproteinase with thrombospondin motifs (ADAMTS) 5, and Matrix metalloproteinases (MMP13) expression, and reduced Forkhead box O (FOXO1) and Light chain 3B (LC3B) expression. Inhibition of PPARγ phosphorylation accelerated the effects of interleukin (IL) 1ß-treatment in both KLF15 KO and WT chondrocytes, and activation of PPARγ expression canceled the IL1ß-induced catabolic effects. CONCLUSION: Our results indicated that the OA phenotype of KLF15 KO DMM mice was influenced by reduced PPARγ expression, including enhanced pIKKα/ß, ADAMTS5, and MMP13 expression, reduced autophagy, and increased apoptosis. KLF15 regulation may constitute a possible therapeutic strategy for the treating OA.


Assuntos
Cartilagem Articular , Osteoartrite , Animais , Masculino , Camundongos , Cartilagem Articular/patologia , Condrócitos/metabolismo , Modelos Animais de Doenças , Fatores de Transcrição Kruppel-Like/genética , Fatores de Transcrição Kruppel-Like/metabolismo , Fatores de Transcrição Kruppel-Like/farmacologia , Mamíferos/metabolismo , Metaloproteinase 13 da Matriz/genética , Metaloproteinase 13 da Matriz/metabolismo , Camundongos Knockout , Osteoartrite/metabolismo , PPAR gama/genética , PPAR gama/metabolismo , Microtomografia por Raio-X
6.
Int J Mol Sci ; 24(21)2023 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-37958756

RESUMO

Previously, we isolated potentially probiotic Ligilactobacillus salivarius strains from the intestines of wakame-fed pigs. The strains were characterized based on their ability to modulate the innate immune responses triggered by the activation of Toll-like receptor (TLR)-3 or TLR4 signaling pathways in intestinal mucosa. In this work, we aimed to evaluate whether nasally administered L. salivarius strains are capable of modulating the innate immune response in the respiratory tract and conferring long-term protection against the respiratory pathogen Streptococcus pneumoniae. Infant mice (3-weeks-old) were nasally primed with L. salivarius strains and then stimulated with the TLR3 agonist poly(I:C). Five or thirty days after the last poly(I:C) administration mice were infected with pneumococci. Among the strains evaluated, L. salivarius FFIG58 had a remarkable ability to enhance the protection against the secondary pneumococcal infection by modulating the respiratory immune response. L. salivarius FFIG58 improved the ability of alveolar macrophages to produce interleukin (IL)-6, interferon (IFN)-γ, IFN-ß, tumor necrosis factor (TNF)-α, IL-27, chemokine C-C motif ligand 2 (CCL2), chemokine C-X-C motif ligand 2 (CXCL2), and CXCL10 in response to pneumococcal challenge. Furthermore, results showed that the nasal priming of infant mice with the FFIG58 strain protected the animals against secondary infection until 30 days after stimulation with poly(I:C), raising the possibility of using nasally administered immunobiotics to stimulate trained immunity in the respiratory tract.


Assuntos
Ligilactobacillus salivarius , Streptococcus pneumoniae , Humanos , Animais , Camundongos , Suínos , Ligantes , Imunidade Inata , Fator de Necrose Tumoral alfa , Quimiocinas
7.
Cureus ; 15(7): e41349, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37546044

RESUMO

Background For successful internal fixation for femoral neck fracture, the sliding mechanism of the screw is important because it can induce inter-fragmental compression. The thread should penetrate the fracture line and be located within the proximal fragment. If screw thread engagement is incomplete and a part of the thread remains within the distal fragment, the screw sliding can be disturbed, potentially leading to fixation failure. We hypothesized that screw thread in the fracture is a risk of fixation failure. Methods We studied 133 hips that underwent internal fixation for femoral neck fracture using dual sliding and compression screws (DSCS) with 20 mm threads. The existence of incomplete thread engagement and fixation failure (cut out, perforation, pseudoarthrosis, or femoral neck shortening) were evaluated on anteroposterior hip radiography postoperatively. The distances from the thread end to the fracture line, screw head to the femoral head cortex, and femoral head diameter were measured to analyze their relationships with any incomplete thread engagement and fixation failure. Differences in evaluation data were assessed using Fisher's exact test, Student's t-test, and receiver operating characteristic (ROC) analysis. Results Forty-six cases had at least one screw with incomplete thread engagement, and the other 87 hips had a complete engagement. The failure rate in the group of hips with incomplete thread engagement was significantly higher (7/46, 15.2%) than that in the group of hips with complete thread engagement (3/87, 3.4%) (P = 0.032). Incomplete thread engagement was found in 59 out of 266 screws (22.2%), and a femoral head ≤ 43.9 mm in diameter was associated with an increased risk of incomplete thread engagement. Most incomplete thread engagement screws (81.4%) had < 5 mm thread length within the distal fragment. Conclusion A partially threaded screw is a significant risk of fixation failure after internal fixation for a femoral neck fracture. The smaller femoral head diameter increases the possibility of incomplete thread engagement. Shortening the thread length by 5 mm may help to avoid incomplete thread engagement.

8.
Stem Cell Rev Rep ; 19(7): 2407-2419, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37477775

RESUMO

The stromal-vascular fraction (SVF), comprising heterogeneous cell populations and adipose-derived stromal cells (ADSCs), has therapeutic potential against osteoarthritis (OA); however, the underlying mechanism remains elusive. This study aimed to investigate the therapeutic effects of heterogeneous cells in rabbit SVF on rabbit chondrocytes. Rabbit SVF and ADSCs were autografted into knees at OA onset. The SVF (1 × 105) and low-dose ADSCs (lADSC; 1 × 104) groups adjusted for their stromal cell content were compared. Animals were euthanized 8 and 12 weeks after OA onset for macroscopic and histological analyses of OA progression and synovitis. Immunohistochemical and real-time polymerase chain reaction assessments were conducted. In vitro, immune-fluorescent double staining was performed for SVF to stain macrophages with F4/80, CD86(M1), and CD163(M2). OA progression was markedly suppressed, and synovitis was reduced in the SVF groups (OARSI histological score 8 W: 6.8 ± 0.75 vs. 3.8 ± 0.75, p = 0.001; 12 W: 8.8 ± 0.4 vs. 5.4 ± 0.49, p = 0.0002). The SVF groups had higher expression of collagen II and SOX9 in cartilage and TGF-ß and IL-10 in the synovium, lower expression of MMP-13, and lower macrophage M1/M2 ratio than the lADSC groups. Immunofluorescent double staining revealed a markedly higher number of M2 than that of M1 macrophages in the SVF. The therapeutic effects of SVF on chondrocytes were superior than those of lADSCs, with enhanced anabolic and inhibited catabolic factors. Heterogeneous cells, mainly M2 macrophages in the SVF, enhanced growth factor secretion and chondrocyte-protective cytokines, thus benefiting chondrocytes and knee joint homeostasis. Overall, the SVF is a safe, relatively simple, and a useful treatment option for OA.

9.
Microorganisms ; 11(5)2023 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-37317122

RESUMO

Orally administered Lacticaseibacillus rhamnosus CRL1505 enhances respiratory immunity, providing protection against respiratory viruses and Streptococcus pneumoniae. However, the capacity of the CRL1505 strain to improve respiratory immunity against Gram-negative bacterial infections has not been evaluated before. The aim of this work was to evaluate whether the Lcb. rhamnosus CRL1505 was able to beneficially regulate the respiratory innate immune response and enhance the resistance to hypermucoviscous KPC-2-producing Klebsiella pneumoniae of the sequence type 25 (ST25). BALB/c mice were treated with the CRL1505 strain via the oral route and then nasally challenged with K. pneumoniae ST25 strains LABACER 01 or LABACER 27. Bacterial cell counts, lung injuries and the respiratory and systemic innate immune responses were evaluated after the bacterial infection. The results showed that K. pneumoniae ST25 strains increased the levels of TNF-α, IL-1ß, IL-6, IFN-γ, IL-17, KC and MPC-1 in the respiratory tract and blood, as well as the numbers of BAL neutrophils and macrophages. Mice treated with Lcb. rhamnosus CRL1505 had significantly lower K. pneumoniae counts in their lungs, as well as reduced levels of inflammatory cells, cytokines and chemokines in the respiratory tract and blood when compared to infected controls. Furthermore, higher levels of the regulatory cytokines IL-10 and IL-27 were found in the respiratory tract and blood of CRL1505-treated mice than controls. These results suggest that the ability of Lcb. rhamnosus CRL1505 to help with the control of detrimental inflammation in lungs during K. pneumoniae infection would be a key feature to improve the resistance to this pathogen. Although further mechanistic studies are necessary, Lcb. rhamnosus CRL1505 can be proposed as a candidate to improve patients' protection against hypermucoviscous KPC-2-producing strains belonging to the ST25, which is endemic in the hospitals of our region.

10.
Int J Mol Sci ; 24(10)2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-37240146

RESUMO

Klebsiella pneumoniae is an opportunistic pathogen that can produce moderate and severe infections in immunosuppressed hosts. In recent years, an increase in the isolation of hypermucoviscous carbapenem-resistant K. pneumoniae with sequence type 25 (ST25) in hospitals in Norwest Argentina was observed. This work aimed to study the virulence and inflammatory potential of two K. pneumoniae ST25 strains (LABACER01 and LABACER27) in the intestinal mucosa. The human intestinal Caco-2 cells were infected with the K. pneumoniae ST25 strains, and their adhesion and invasion rates and changes in the expression of tight junction and inflammatory factors genes were evaluated. ST25 strains were able to adhere and invade Caco-2 cells, reducing their viability. Furthermore, both strains reduced the expression of tight junction proteins (occludin, ZO-1, and claudin-5), altered permeability, and increased the expression of TGF-ß and TLL1 and the inflammatory factors (COX-2, iNOS, MCP-1, IL-6, IL-8, and TNF-α) in Caco-2 cells. The inflammatory response induced by LABACER01 and LABACER27 was significantly lower than the one produced by LPS or other intestinal pathogens, including K. pneumoniae NTUH-K2044. No differences in virulence and inflammatory potential were found between LABACER01 and LABACER27. In line with these findings, no major differences between the strains were found when the comparative genomic analysis of virulence factors associated with intestinal infection/colonization was performed. This work is the first to demonstrate that hypermucoviscous carbapenem-resistant K. pneumoniae ST25 infects human intestinal epithelial cells and induces moderate inflammation.


Assuntos
Enterobacteriáceas Resistentes a Carbapenêmicos , Infecções por Klebsiella , Humanos , Klebsiella pneumoniae/genética , Células CACO-2 , Carbapenêmicos/farmacologia , Inflamação , Antibacterianos/farmacologia , Metaloproteases Semelhantes a Toloide
11.
Orthop Traumatol Surg Res ; 109(8): 103598, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36933617

RESUMO

BACKGROUND: A mobile bearing can dislocate when joint laxity is larger than jumping height, the height difference between the bottom and the peak of the bearing (the highest point of the upper bearing surface on each side). Significant laxity due to improper gap balancing should therefore be avoided. However, once the bearing rotates vertically on the tibial component, the bearing can dislocate with smaller laxity than the jumping height. We mathematically calculated the required laxity for dislocation (RLD) and the required rotation of the bearing for dislocation (RRD). The current study addressed the question: 1) could the femoral component size and the bearing thickness affect the RLD and RRD? HYPOTHESIS: The femoral component size and the bearing thickness could affect the MLD and MRD. METHODS: The RLD and RRD were calculated using the bearing dimensions provided by the manufacturer with femoral component size, bearing thickness, and directions (anterior, posterior, and medial/lateral) as the variables on a two-dimensional basis. RESULTS: The RLD was 3.4 to 5.5mm in the anterior, 2.3 to 3.8mm in the posterior, and 1.4 to 2.4mm in the medial or lateral directions. The RLD decreased with a smaller femoral size or a thicker bearing. Similarly, the RRD decreased with a smaller femoral size or a thicker bearing thickness in all directions. CONCLUSIONS: Increased bearing thickness and decreased femoral component size deceased the RLD and RRD, which would relate to an increased risk of dislocation. Selecting the femoral component as large as possible and the bearing as thin as possible would therefore be helpful in the prevention of dislocation. LEVEL OF EVIDENCE: III; comparative computer simulation study.


Assuntos
Artroplastia do Joelho , Luxações Articulares , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/efeitos adversos , Prótese do Joelho/efeitos adversos , Simulação por Computador , Luxações Articulares/cirurgia , Tíbia/cirurgia , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia
12.
Knee ; 42: 136-142, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37001330

RESUMO

PURPOSE: To evaluate the bearing orbit of the tibial component during extension-flexion motion in Oxford unicompartmental knee arthroplasty. MATERIALS AND METHODS: A total of 32 knees in 25 patients with medial osteoarthritis who underwent Oxford unicompartmental knee arthroplasty were evaluated. The distance between the vertical wall of the tibial component and the bearing (wall-bearing distance) and that between the anterior edge of the tibial component and the bearing (sagittal bearing position) were measured at 0°, 30°, 60°, 90° and 120° knee flexion with neutral tibial rotation (extension-flexion motion), and internal and external tibial rotation with 90° knee flexion (tibial rotation motion). A custom-made rounded trial bearing and caliper were used for this measurement. We calculated the wall-bearing distance, change in extension-flexion motion and tibial rotation motion. Wall-bearing distances and change in wall-bearing distance were compared using ANOVA or t-test. RESULTS: The wall-bearing distance was smallest at 60° and increased 1.0 ± 1.1 mm in knee extension and 1.1 ± 1.5 mm in knee flexion. The bearing moved posteriorly with knee flexion, and the sagittal bearing position increased by 8.1 ± 3.4 mm during extension-flexion motion. Consequently, the bearing moved in a rough C-shaped orbit of the tibial component. CONCLUSIONS: The mobile bearing moves in a rough C-shape and is mostly close to the vertical wall of the tibial component at 60°. The wall-bearing distance can change during extension-flexion motion and might be influenced by tibial component rotation. To avoid bearing separation from or contact with the vertical wall that may cause bearing dislocation, the wall-bearing distance should be evaluated before keel slot preparation.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Órbita/cirurgia , Osteoartrite do Joelho/cirurgia , Amplitude de Movimento Articular , Tíbia/cirurgia
13.
Vaccines (Basel) ; 11(3)2023 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-36992195

RESUMO

Previously, we demonstrated that nasally administered Corynebacterium pseudodiphtheriticum 090104 (Cp) or its bacterium-like particles (BLPs) increase the resistance of mice against bacterial and viral respiratory pathogens by modulating the innate immunity. In this work, we evaluated the ability of Cp and BLPs to stimulate alveolar macrophages, and to enhance the humoral immune response induced by a commercial vaccine against Streptococcus pneumoniae. In the first set of experiments, Cp or the BLPs were incubated with primary cultures of murine alveolar macrophages and the phagocytic activity, and the production of cytokines was evaluated. The results revealed that Cp and BLPs were efficiently phagocyted by respiratory macrophages and that both treatments triggered the production of TNF-α, IFN-γ, IL-6, and IL-1ß. In the second set of experiments, 3-week-old Swiss mice were intranasally immunized at days 0, 14, and 28 with the pneumococcal vaccine Prevenar®13 (PCV), Cp + PCV, or BLPs + PCV. On day 33, samples of bronco-alveolar lavages (BAL) and serum were collected for the study of specific antibodies. In addition, immunized mice were challenged with S. pneumoniae serotypes 6B or 19F on day 33 and sacrificed on day 35 (day 2 post-infection) to evaluate the resistance to the infection. Both Cp + PCV and BLPs + PCV groups had higher specific serum IgG and BAL IgA antibodies than the PCV control mice. In addition, the mice that were immunized with Cp + PCV or BLPs + PCV had lower lung and blood pneumococcal cell counts as well as lower levels of BAL albumin and LDH, indicating a reduced lung damage compared to the control mice. Improved levels of anti-pneumococcal antibodies were also detected in the serum and BAL samples after the challenges with the pathogens. The results demonstrated that C. pseudodiphtheriticum 090104 and its bacterium-like particles are capable of stimulating the respiratory innate immune system serving as adjuvants to potentiate the adaptive humoral immune response. Our study is a step forward in the positioning of this respiratory commensal bacterium as a promising mucosal adjuvant for vaccine formulations aimed at combating respiratory infectious diseases.

14.
Knee ; 40: 220-226, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36512893

RESUMO

BACKGROUND: Unicompartmental knee arthroplasty (UKA) can provide good postoperative results and long term survival, but there may be complications. We present a rare case of avulsion fracture of the intercondylar eminence during UKA surgery. CASE PRESENTATION: An 88-year-old man had right-knee pain with anteromedial osteoarthritis. Oxford partial knee UKA (Zimmer Biomet, Warsaw, IN) was performed by the senior author by the under-vastus approach using Microplasty instruments. During the final check of the range of motion, an avulsion fracture of the intercondylar eminence occurred at the terminal extension. A 4.0 mm cannulated cancellous screw was inserted into the intercondylar eminence from just in front of the anterior cruciate ligament to the posterior tibial cortex. Six months postoperatively, bony fusion was confirmed by lateral radiography. Two years after the surgery, the patient was fully satisfied. The flexion angle was 125°, but still with an extension limit of 10°. DISCUSSION: Avulsion fracture of the intercondylar eminence can be caused by hyperextension and/or the ACL becoming tighter in full extension of the knee. In this patient, avulsion fracture also probably occurred due to increased tension of the ACL in the fully extended position. After making the horizontal cut, we inserted a thin metal plate to prevent deeper vertical cuts, but an excessive horizontal cut was a possible cause of the fracture. As treatment for avulsion fracture of the intercondylar eminence, fixation of the cannulated cancellous screw resulted in uneventful bone fusion. We recommend having a cannulated cancellous screw at hand for such complications and for other potential intraoperative problems, such as tibial plateau fracture. Further investigation into limited postoperative extension might be needed. CONCLUSION: Our patient had intraoperative avulsion fracture of the intercondylar eminence, a relatively rare complication of Oxford UKA which is probably caused by the extension being tight and/or an excessive horizontal cut. Having a cannulated cancellous screw at hand is advised, and attention should be paid to postoperative limit of extension.


Assuntos
Artroplastia do Joelho , Fratura Avulsão , Artropatias , Fraturas da Tíbia , Masculino , Humanos , Idoso de 80 Anos ou mais , Fratura Avulsão/diagnóstico por imagem , Fratura Avulsão/cirurgia , Artroscopia/métodos , Ligamento Cruzado Anterior/cirurgia , Articulação do Joelho/cirurgia , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Artropatias/cirurgia
15.
Knee Surg Relat Res ; 34(1): 43, 2022 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-36369104

RESUMO

BACKGROUND: This study aims to assess the influence of intramedullary rods on the implantation positions of femoral components using Microplasty instrumentation in Oxford unicompartmental knee arthroplasty. We hypothesized that femoral components can be laterally implanted incorrectly when using intramedullary rods. METHODS: This prospective study included all 45 consecutive patients (53 knees) who underwent Oxford unicompartmental knee arthroplasty surgery for anteromedial osteoarthritis or spontaneous osteonecrosis of the knee at our hospital during the study period. A custom-made toolset comprising a triangular caliper and circular trial bearings was used to evaluate the distance between the bearing and the vertical wall of the tibia implant (wall-bearing space) using the caliper at 90° flexion both with and without intramedullary rods. RESULTS: The wall-bearing space was significantly larger when the intramedullary rod was used than when intramedullary rod was not used (1.8 ± 1.1 mm versus 3.4 ± 1.2 mm, P < 0.001). The mean difference of wall-bearing space with and without intramedullary rod was 1.6 ± 0.7 mm. CONCLUSIONS: Femoral components can be laterally implanted incorrectly by an average of 1.6 mm when using intramedullary rods. The wall-bearing space should be evaluated using trial components, and if the relationship is improper, it should be corrected before keel slot preparation.

16.
J Knee Surg ; 2022 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-36270323

RESUMO

In restricted kinematic alignment total knee arthroplasty (TKA), bone resection is performed within a safe range to help protect against failure from extreme alignments. Patient-specific instrumentation, navigations, and robotics are often required for restricting bone cuts within a specified safe zone. We hypothesized that the lateral malleolus could be used as a landmark for restricting the tibial osteotomy using a mechanical jig. Here, we examine its feasibility in anatomical and clinical settings. We studied long-leg standing radiographs of 114 consecutive patients (228 knees) who underwent knee arthroplasty in our institution. We measured the lateral malleolus angle (LMA), the angle between the tibial axis and the line between the center of the knee and the lateral surface of the lateral malleolus. The medial proximal tibial angle was also measured before and after restricted kinematic alignment TKA under restriction with reference to the lateral malleolus. Mean LMA was 5.5 ± 0.5 degrees. This was relatively consistent and independent of patient's height, weight, and body mass index. The lateral malleolus is a reliable bone landmark that can be used to recognize approximately 5.5 degrees of varus intraoperatively. A surgeon can use this as a restriction of the tibial varus cut up to 6 degrees without the requirement for expensive assistive technologies.

17.
Bone Joint J ; 104-B(10): 1118-1125, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36177640

RESUMO

AIMS: A fracture of the medial tibial plateau is a serious complication of Oxford mobile-bearing unicompartmental knee arthroplasty (OUKA). The risk of these fractures is reportedly lower when using components with a longer keel-cortex distance (KCDs). The aim of this study was to examine how slight varus placement of the tibial component might affect the KCDs, and the rate of tibial plateau fracture, in a clinical setting. METHODS: This retrospective study included 255 patients who underwent 305 OUKAs with cementless tibial components. There were 52 males and 203 females. Their mean age was 73.1 years (47 to 91), and the mean follow-up was 1.9 years (1.0 to 2.0). In 217 knees in 187 patients in the conventional group, tibial cuts were made orthogonally to the tibial axis. The varus group included 88 knees in 68 patients, and tibial cuts were made slightly varus using a new osteotomy guide. Anterior and posterior KCDs and the origins of fracture lines were assessed using 3D CT scans one week postoperatively. The KCDs and rate of fracture were compared between the two groups. RESULTS: Medial tibial fractures occurred after surgery in 15 patients (15 OUKAs) in the conventional group, but only one patient (one OUKA) had a tibial fracture after surgery in the varus group. This difference was significant (6.9% vs 1.1%; p = 0.029). The mean posterior KCD was significantly shorter in the conventional group (5.0 mm (SD 1.7)) than in the varus group (6.1 mm (SD 2.1); p = 0.002). CONCLUSION: In OUKA, the distance between the keel and posterior tibial cortex was longer in our patients with slight varus alignment of the tibial component, which seems to decrease the risk of postoperative tibial fracture.Cite this article: Bone Joint J 2022;104-B(10):1118-1125.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Fraturas da Tíbia , Idoso , Artroplastia do Joelho/efeitos adversos , Feminino , Humanos , Articulação do Joelho/cirurgia , Prótese do Joelho/efeitos adversos , Masculino , Osteoartrite do Joelho/complicações , Osteoartrite do Joelho/cirurgia , Estudos Retrospectivos , Tíbia/cirurgia , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/etiologia , Fraturas da Tíbia/cirurgia
19.
Knee ; 35: 54-60, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35220133

RESUMO

BACKGROUND: Restricted kinematically-aligned total knee arthroplasty (KA-TKA) is a reasonable modification to avoid the alignment outlier that may cause implant failure. However, despite a noted high incidence of constitutional varus in Japanese individuals, there has been no investigation into how many knees require the restriction in restricted KA-TKA (RKA-TKA) among Japanese patients. Therefore, we conducted a study using preoperative long-leg radiograms. METHODS: We studied long-leg radiographs of 228 knees in 114 consecutive patients. The numbers of knees within the safety range and their corrective osteotomy angle in the restriction algorithms advocated by Almaawi et al. (2017) and MacDessi et al. (2020) were evaluated. RESULTS: According to the algorithms used by Almaawi et al. and MacDessi et al., out of 228 knees, 46 (20%) and 39 (17%) fell within the safety range, respectively. The mean correction angles of the hip-knee-ankle angle, lateral distal femoral angle and medial proximal tibial angle were 2.8 ± 3.4°, 0.4 ± 1.4° and 2.4 ± 2.8° in the algorithm used by Almaawi et al., while they were -4.9 ± 4.7°, 1.1 ± 2.5° and -6.0 ± 3.4° in the algorithm used by MacDessi et al. Most of the knees needed to be restricted in order to perform RKA-TKA, regardless of the algorithm used. CONCLUSIONS: Based on a preoperative analysis of long-leg radiograms in a Japanese population, most knees fall out of the safety range in RKA-TKA. Surgeons must consider whether to allow component outlier or to perform corrective osteotomy that likely requires soft tissue release.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Artroplastia do Joelho/efeitos adversos , Fenômenos Biomecânicos , Humanos , Japão/epidemiologia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Perna (Membro)/cirurgia , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia
20.
J Arthroplasty ; 37(5): 942-947, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35074447

RESUMO

BACKGROUND: Bearing dislocation is a serious complication after Oxford unicompartmental knee arthroplasty. Bearing separation from the lateral wall can cause it to spin (90° horizontal rotation) and eventually dislocate because there is just a 2 mm difference in height in both the lateral and medial sides from the bottom of the bearing, compared with the anterior (5 mm) and posterior (3 mm) sides. The details of this problem have not been previously examined. METHODS: Twenty-one dislocations in 12 patients were retrospectively analyzed. Bearing separation was defined as the bearing position being sufficiently distant from the lateral wall of the tibial component to allow spinning. We analyzed the incidence of separation, the direction and the recurrence of the dislocations, and their causes and treatments. RESULTS: Five of the 12 patients had separation. Of the total of 21 dislocations, 11 occurred in cases of separation (52%). Seven of 11 anterior dislocations were found to have separation, whereas nine of 13 posterior dislocations occurred without separation (P = .0237). Three of 5 patients with separation had recurrence of dislocation, and eventually 2 underwent revision to fixed-bearing unicompartmental knee arthroplasty. CONCLUSION: Bearing separation from the lateral wall of the tibial component can cause bearing dislocation, especially in an anterior direction. To prevent separation, the wall-bearing distance should be evaluated before the keel slot preparation, with manipulation as necessary. Conversely, posterior dislocation was predominant in our nonseparation cases.


Assuntos
Artroplastia do Joelho , Luxações Articulares , Prótese do Joelho , Osteoartrite do Joelho , Artroplastia do Joelho/efeitos adversos , Humanos , Luxações Articulares/cirurgia , Articulação do Joelho/cirurgia , Prótese do Joelho/efeitos adversos , Osteoartrite do Joelho/etiologia , Osteoartrite do Joelho/cirurgia , Estudos Retrospectivos , Tíbia/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...